Search NASA⌕ Search

SEARCH · Search NASA

Results for “User interface”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

FEgen (v.1): Field Emission Distribution Generator Freeware Based on Fowler–Nordheim Equation

This work presents an open-source code, FEgen, that generates initial field emission distributions based on the time-dependent Fowler–Nordheim equation. Current in-demand and open-source beam tracking software—such as ASTRA, IMPACT-T, and GPT—do not contain native distribution generator functions suitable for field emitted electron tracking and phase space analysis. Furthermore, the intuitive graphical user interface of FEgen generates input files shown to be fully compatible with both ASTRA and GPT. Here, detailed application examples demonstrating a subset of FEgen’s capabilities are given by creating a customized emitter pattern with application to transverse beam shaping and longitudinal beam dynamic experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cross-facility science with the Superfacility Project at LBNL

As data sets from DOE user science facilities grow in both size and complexity there is an urgent need for new capabilities to transfer, analyze and manage the data underlying scientific discoveries. LBNL's Superfacility project brings together experimental and observational research instruments with computational and network facilities at the National Energy Research Scientific Computing Center (NERSC) and the Energy Sciences Network (ESnet) with the goal of enabling user science. Here, we report on recent innovations in the Superfacility project, including advanced data management, API-based automation, real-Time interactive user interfaces, and supported infrastructure for 'edge' services.

Enders, B↗

Technical Note: SPEKTR 3.0—A computational tool for x-ray spectrum modeling and analysis

Purpose: A computational toolkit (SPEKTR 3.0) has been developed to calculate x-ray spectra based on the tungsten anode spectral model using interpolating cubic splines (TASMICS) algorithm, updating previous work based on the tungsten anode spectral model using interpolating polynomials (TASMIP) spectral model. The toolkit includes a MATLAB (The Mathworks, Natick, MA) function library and improved user interface (UI) along with an optimization algorithm to match calculated beam quality with measurements. Methods: The SPEKTR code generates x-ray spectra (photons/mm{sup 2}/mAs at 100 cm from the source) using TASMICS as default (with TASMIP as an option) in 1 keV energy bins over beam energies 20–150 kV, extensible to 640 kV using the TASMICS spectra. An optimization tool was implemented to compute the added filtration (Al and W) that provides a best match between calculated and measured x-ray tube output (mGy/mAs or mR/mAs) for individual x-ray tubes that may differ from that assumed in TASMICS or TASMIP and to account for factors such as anode angle. Results: The median percent difference in photon counts for a TASMICS and TASMIP spectrum was 4.15% for tube potentials in the range 30–140 kV with the largest percentage difference arising in the low and high energy bins due to measurement errors in the empirically based TASMIP model and inaccurate polynomial fitting. The optimization tool reported a close agreement between measured and calculated spectra with a Pearson coefficient of 0.98. Conclusions: The computational toolkit, SPEKTR, has been updated to version 3.0, validated against measurements and existing models, and made available as open source code. Video tutorials for the SPEKTR function library, UI, and optimization tool are available.

60 APPLIED LIFE SCIENCES↗

SU-C-BRC-07: Parametrized GPU Accelerated Electron Monte Carlo Second Check

Purpose: I am presenting a parameterized 3D GPU accelerated electron Monte Carlo second check program. Method: I wrote the 3D grid dose calculation algorithm in CUDA and utilized an NVIDIA GeForce GTX 780 Ti to run all of the calculations. The electron path beyond the distal end of the cone is governed by four parameters: the amplitude of scattering (AMP), the mean and width of a Gaussian energy distribution (E and α), and the percentage of photons. In my code, I adjusted all parameters until the calculated PDD and profile fit the measured 10×10 open beam data within 1%/1mm. I then wrote a user interface for reading the DICOM treatment plan and images in Python. In order to verify the algorithm, I calculated 3D dose distributions on a variety of phantoms and geometries, and compared them with the Eclipse eMC calculations. I also calculated several patient specific dose distributions, including a nose and an ear. Finally, I compared my algorithm’s computation times to Eclipse’s. Results: The calculated MU for all of the investigated geometries agree with the TPS within the TG-114 action level of 5%. The MU for the nose was < 0.5 % different while the MU for the ear at 105 SSD was ∼2 %. Calculation times for a 12MeV 10×10 open beam ranged from 1 second for a 2.5 mm grid resolution with ∼15 million particles to 33 seconds on a 1 mm grid with ∼460 million particles. Eclipse calculation runtimes distributed over 10 FAS workers were 9 seconds to 15 minutes respectively. Conclusion: The GPU accelerated second check allows quick MU verification while accounting for patient specific geometry and heterogeneity.

60 APPLIED LIFE SCIENCES↗

SU-F-I-63: Relaxation Times of Lipid Resonances in NAFLD Animal Model Using Enhanced Curve Fitting

Purpose: The objective of this study is to evaluate the relaxation time of methylene resonance in comparison with other lipid resonances. Methods: The examinations were performed on a 3.0T MRI scanner using a four-channel animal coil. Eight more Sprague-Dawley rats in the same baseline weight range were housed with ad libitum access to water and a high-fat (HF) diet (60% fat, 20% protein, and 20% carbohydrate). In order to avoid large blood vessels, a voxel (0.8×0.8×0.8 cm{sup 3}) was placed in a homogeneous area of the liver parenchyma during free breathing. Lipid relaxations in NC and HF diet rats were estimated at a fixed repetition time (TR) of 6000 msec, and multi echo time (TEs) of 40–220 msec. All spectra for data measurement were processed using the Advanced Method for Accurate, Robust, and Efficient Spectral (AMARES) fitting algorithm of the Java-based Magnetic Resonance User Interface (jMRUI) package. Results: The mean T2 relaxation time of the methylene resonance in normal-chow diet was 37.1 msec (M{sub 0}, 2.9±0.5), with a standard deviation of 4.3 msec. The mean T2 relaxation time of the methylene resonance was 31.4 msec (M{sub 0}, 3.7±0.3), with a standard deviation of 1.8 msec. The T2 relaxation times of methylene protons were higher in normal-chow diet rats than in HF rats (p<0.05), and the extrapolated M{sub 0} values were higher in HF rats than in NC rats (p<0.005). The excellent linear fit with R{sup 2}>0.9971 and R{sup 2}>0.9987 indicates T2 relaxation decay curves with mono-exponential function. Conclusion: In in vivo, a sufficient spectral resolution and a sufficiently high signal-to-noise ratio (SNR) can be achieved, so that the data measured over short TE values can be extrapolated back to TE = 0 to produce better estimates of the relative weights of the spectral components. In the short term, treating the effective decay rate as exponential is an adequate approximation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-540: Comprehensive Fluence Delivery Optimization with Multileaf Collimation

Purpose: Multileaf collimator (MLC) leaf sequencing is performed via commercial black-box implementations, on which a user has limited to no access. We have developed an explicit, generic MLC sequencing model to serve as a tool for future investigations of fluence map optimization, fluence delivery optimization, and rotational collimator delivery methods. Methods: We have developed a novel, comprehensive model to effectively account for a variety of transmission and penumbra effects previously treated on an ad hoc basis in the literature. As the model is capable of quantifying a variety of effects, we utilize the asymmetric leakage intensity across each leaf to deliver fluence maps with pixel size smaller than the narrowest leaf width. Developed using linear programming and mixed integer programming formulations, the model is implemented using state of the art open-source solvers. To demonstrate the versatility of the algorithm, a graphical user interface (GUI) was developed in MATLAB capable of accepting custom leaf specifications and transmission parameters. As a preliminary proof-ofconcept, we have sequenced the leaves of a Varian 120 Leaf Millennium MLC for five prostate cancer patient fields and one head and neck field. Predetermined fluence maps have been processed by data smoothing methods to obtain pixel sizes of 2.5 cm{sup 2}. The quality of output was analyzed using computer simulations. Results: For the prostate fields, an average root mean squared error (RMSE) of 0.82 and gamma (0.5mm/0.5%) of 91.4% were observed compared to RMSE and gamma (0.5mm/0.5%) values of 7.04 and 34.0% when the leakage considerations were omitted. Similar results were observed for the head and neck case. Conclusion: A model to sequence MLC leaves to optimality has been proposed. Future work will involve extensive testing and evaluation of the method on clinical MLCs and comparison with black-box leaf sequencing algorithms currently used by commercial treatment planning systems.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-15: Feasibility Study of Fiber-Optic Cerenkov Radiation Sensors for in Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

Purpose: To evaluate the possibility of a fiber-optic Cerenkov radiation sensor (FCRS) for in vivo dose verification in proton therapy. Methods: The Cerenkov radiation due to the proton beam was measured using a homemade phantom, consisting of a plastic optical fiber (POF, PGSCD1001-13-E, Toray, Tokyo, Japan) connected to each channel of a multianode photomultiplier tube (MAPMT:H7546, Hamamatsu Photonics, Shizuoka, Japan). Data were acquired using a multi-anode photomultiplier tube with the NI-DAQ system (National Instruments Texas, USA). The real-time monitoring graphic user interface was programmed using Labview. The FCRS was analyzed for its dosimetrics characteristic in proton beam. To determine the accuracy of the FCRS in proton dose measurements, we compared the ionization chamber dose measurements using a water phantom. We investigated the feasibility of the FCRS for the measurement of dose distributions near the superficial region for proton plans with a varying separation between the target volume and the surface of 3 patients using a humanoid phantom. Results: The dose-response has good linearity. Dose-rate and energy dependence were found to be within 1%. Depth-dose distributions in non-modulated proton beams obtained with the FCRS was in good agreement with the depth-dose measurements from the ionization chamber. To evaluate the dosimetric accuracy of the FCRS, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the FCRS was within 3%. With in vivo dosimetry using the humanoid phantom, the calculated surface doses overestimated measurements by 4%–8% using FCRS. Conclusion: In previous study, our results indicate that the performance of the array-type FCRS was comparable to that of the currently used a multi-layer ion chamber system. In this study, we also believe that the fiber-optic Cerenkov radiation sensor has considerable potential for use with in vivo patient proton dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

MO-DE-BRA-02: SIMAC: A Simulation Tool for Teaching Linear Accelerator Physics

Purpose: The first goal of this work is to develop software that can simulate the physics of linear accelerators (linac). The second goal is to show that this simulation tool is effective in teaching linac physics to medical physicists and linac service engineers. Methods: Linacs were modeled using analytical expressions that can correctly describe the physical response of a linac to parameter changes in real time. These expressions were programmed with a graphical user interface in order to produce an environment similar to that of linac service mode. The software, “SIMAC”, has been used as a learning aid in a professional development course 3 times (2014 – 2016) as well as in a physics graduate program. Exercises were developed to supplement the didactic components of the courses consisting of activites designed to reinforce the concepts of beam loading; the effect of steering coil currents on beam symmetry; and the relationship between beam energy and flatness. Results: SIMAC was used to teach 35 professionals (medical physicists; regulators; service engineers; 1 week course) as well as 20 graduate students (1 month project). In the student evaluations, 85% of the students rated the effectiveness of SIMAC as very good or outstanding, and 70% rated the software as the most effective part of the courses. Exercise results were collected showing that 100% of the students were able to use the software correctly. In exercises involving gross changes to linac operating points (i.e. energy changes) the majority of students were able to correctly perform these beam adjustments. Conclusion: Software simulation(SIMAC), can be used to effectively teach linac physics. In short courses, students were able to correctly make gross parameter adjustments that typically require much longer training times using conventional training methods.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-03: Pre-Treatment Surface Imaging Based Collision Detection

Purpose: Modern radiotherapy increasingly employs large immobilization devices, gantry attachments, and couch rotations for treatments. All of which raise the risk of collisions between the patient and the gantry / couch. Collision detection is often achieved by manually checking each couch position in the treatment room and sometimes results in extraneous imaging if collisions are detected after image based setup has begun. In the interest of improving efficiency and avoiding extra imaging, we explore the use of a surface imaging based collision detection model. Methods: Surfaces acquired from AlignRT (VisionRT, London, UK) were transferred in wavefront format to a custom Matlab (Mathworks, Natick, MA) software package (CCHECK). Computed tomography (CT) scans acquired at the same time were sent to CCHECK in DICOM format. In CCHECK, binary maps of the surfaces were created and overlaid on the CT images based on the fixed relationship of the AlignRT and CT coordinate systems. Isocenters were added through a graphical user interface (GUI). CCHECK then compares the inputted surfaces to a model of the linear accelerator (linac) to check for collisions at defined gantry and couch positions. Note, CCHECK may be used with or without a CT. Results: The nominal surface image field of view is 650 mm × 900 mm, with variance based on patient position and size. The accuracy of collision detections is primarily based on the linac model and the surface mapping process. The current linac model and mapping process yield detection accuracies on the order of 5 mm, assuming no change in patient posture between surface acquisition and treatment. Conclusions: CCHECK provides a non-ionizing method to check for collisions without the patient in the treatment room. Collision detection accuracy may be improved with more robust linac modeling. Additional gantry attachments (e.g. conical collimators) can be easily added to the model.

60 APPLIED LIFE SCIENCES↗

TU-D-201-06: HDR Plan Prechecks Using Eclipse Scripting API

Purpose: Automate brachytherapy treatment plan quality check using Eclipse v13.6 scripting API based on pre-configured rules to minimize human error and maximize efficiency. Methods: The HDR Precheck system is developed based on a rules-driven approach using Eclipse scripting API. This system checks for critical plan parameters like channel length, first source position, source step size and channel mapping. The planned treatment time is verified independently based on analytical methods. For interstitial or SAVI APBI treatment plans, a Patterson-Parker system calculation is performed to verify the planned treatment time. For endobronchial treatments, an analytical formula from TG-59 is used. Acceptable tolerances were defined based on clinical experiences in our department. The system was designed to show PASS/FAIL status levels. Additional information, if necessary, is indicated appropriately in a separate comments field in the user interface. Results: The HDR Precheck system has been developed and tested to verify the treatment plan parameters that are routinely checked by the clinical physicist. The report also serves as a reminder or checklist for the planner to perform any additional critical checks such as applicator digitization or scenarios where the channel mapping was intentionally changed. It is expected to reduce the current manual plan check time from 15 minutes to <1 minute. Conclusion: Automating brachytherapy plan prechecks significantly reduces treatment plan precheck time and reduces human errors. When fully developed, this system will be able to perform TG-43 based second check of the treatment planning system’s dose calculation using random points in the target and critical structures. A histogram will be generated along with tabulated mean and standard deviation values for each structure. A knowledge database will also be developed for Brachyvision plans which will then be used for knowledge-based plan quality checks to further reduce treatment planning errors and increase confidence in the planned treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

A tracking system to calculate patient skin dose in real-time during neurointerventional procedures using a biplane x-ray imaging system

Purpose: Neurovascular interventional procedures using biplane fluoroscopic imaging systems can lead to increased risk of radiation-induced skin injuries. The authors developed a biplane dose tracking system (Biplane-DTS) to calculate the cumulative skin dose distribution from the frontal and lateral x-ray tubes and display it in real-time as a color-coded map on a 3D graphic of the patient for immediate feedback to the physician. The agreement of the calculated values with the dose measured on phantoms was evaluated. Methods: The Biplane-DTS consists of multiple components including 3D graphic models of the imaging system and patient, an interactive graphical user interface, a data acquisition module to collect geometry and exposure parameters, the computer graphics processing unit, and functions for determining which parts of the patient graphic skin surface are within the beam and for calculating dose. The dose is calculated to individual points on the patient graphic using premeasured calibration files of entrance skin dose per mAs including backscatter; corrections are applied for field area, distance from the focal spot and patient table and pad attenuation when appropriate. The agreement of the calculated patient skin dose and its spatial distribution with measured values was evaluated in 2D and 3D for simulated procedure conditions using a PMMA block phantom and an SK-150 head phantom, respectively. Dose values calculated by the Biplane-DTS were compared to the measurements made on the phantom surface with radiochromic film and a calibrated ionization chamber, which was also used to calibrate the DTS. The agreement with measurements was specifically evaluated with variation in kVp, gantry angle, and field size. Results: The dose tracking system that was developed is able to acquire data from the two x-ray gantries on a biplane imaging system and calculate the skin dose for each exposure pulse to those vertices of a patient graphic that are determined to be in the beam. The calculations are done in real-time with a typical graphic update time of 30 ms and an average vertex separation of 3 mm. With appropriate corrections applied, the Biplane-DTS was able to determine the entrance dose within 6% and the spatial distribution of the dose within 4% compared to the measurements with the ionization chamber and film for the SK150 head phantom. The cumulative dose for overlapping fields from both gantries showed similar agreement. Conclusions: The Biplane-DTS can provide a good estimate of the peak skin dose and cumulative skin dose distribution during biplane neurointerventional procedures. Real-time display of this information should help the physician manage patient dose to reduce the risk of radiation-induced skin injuries.

60 APPLIED LIFE SCIENCES↗

Technical Note: SCUDA: A software platform for cumulative dose assessment

Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.

60 APPLIED LIFE SCIENCES↗

Modification and analysis of context-specific genome-scale metabolic models: methane-utilizing microbial chassis as a case study

ABSTRACT Context-specific genome-scale model (CS-GSM) reconstruction is becoming an efficient strategy for integrating and cross-comparing experimental multi-scale data to explore the relationship between cellular genotypes, facilitating fundamental or applied research discoveries. However, the application of CS modeling for non-conventional microbes is still challenging. Here, we present a graphical user interface that integrates COBRApy, EscherPy, and RIPTiDe, Python-based tools within the BioUML platform, and streamlines the reconstruction and interrogation of the CS genome-scale metabolic frameworks via Jupyter Notebook. The approach was tested using -omics data collected for Methylotuvimicrobium alcaliphilum 20Z R , a prominent microbial chassis for methane capturing and valorization. We optimized the previously reconstructed whole genome-scale metabolic network by adjusting the flux distribution using gene expression data. The outputs of the automatically reconstructed CS metabolic network were comparable to manually optimized i IA409 models for Ca-growth conditions. However, the CS model questions the reversibility of the phosphoketolase pathway and suggests higher flux via primary oxidation pathways. The model also highlighted unresolved carbon partitioning between assimilatory and catabolic pathways at the formaldehyde-formate node. Only a very few genes and only one enzyme with a predicted function in C1 metabolism, a homolog of the formaldehyde oxidation enzyme ( fae1-2 ), showed a significant change in expression in La-growth conditions. The CS-GSM predictions agreed with the experimental measurements under the assumption that the Fae1-2 is a part of the tetrahydrofolate-linked pathway. The cellular roles of the tungsten (W)-dependent formate dehydrogenase ( fdhAB ) and fae homologs ( fae1-2 and fae3 ) were investigated via mutagenesis. The phenotype of the f dhAB mutant followed the model prediction. Furthermore, a more significant reduction of the biomass yield was observed during growth in La-supplemented media, confirming a higher flux through formate. M. alcaliphilum 20Z R mutants lacking fae1-2 did not display any significant defects in methane or methanol-dependent growth. However, contrary to fae1, the fae1-2 homolog failed to restore the formaldehyde-activating enzyme function in complementation tests. Overall, the presented data suggest that the developed computational workflow supports the reconstruction and validation of CS-GSM networks of non-model microbes. IMPORTANCE The interrogation of various types of data is a routine strategy to explore the relationship between genotype and phenotype. An efficient approach for integrating and cross-comparing experimental multi-scale data in the context of whole-genome-based metabolic network reconstruction becomes a powerful tool that facilitates fundamental and applied research discoveries. The present study describes the reconstruction of a context-specific (CS) model for the methane-utilizing bacterium, Methylotuvimicrobium alcaliphilum 20Z R . M. alcaliphilum 20Z R is becoming an attractive microbial platform for the production of biofuels, chemicals, pharmaceuticals, and bio-sorbents for capturing atmospheric methane. We demonstrate that this pipeline can help reconstruct metabolic models that are similar to manually curated networks. Furthermore, the model is able to highlight previously overlooked pathways, thus advancing fundamental knowledge of non-model microbial systems or promoting their development toward biotechnological or environmental implementations.

Kulyashov, M. A.↗

Fluctuating Hydrodynamics Methods for Dynamic Coarse-Grained Implicit-Solvent Simulations in LAMMPS

We present a software package integrated with the molecular dynamics software LAMMPS for fluctuating hydrodynamics simulations of fluid-structure interactions subject to thermal fluctuations. The package is motivated to provide dynamic thermostats to extend implicit-solvent coarse-grained (IS-CG) models by incorporating kinetic contributions from the solvent to facilitate their use in a wider range of applications. To capture the thermal and hydrodynamic contributions of the solvent to dynamics, we introduce momentum conserving thermostats and computational methods based on fluctuating hydrodynamics and the stochastic Eulerian Lagrangian method (SELM). SELM couples the coarse-grained microstructure degrees of freedom to continuum stochastic fields to capture both the relaxation of hydrodynamic modes and thermal fluctuations. Features of the SELM software include (i) numerical time-step integrators for SELM fluctuating hydrodynamics in inertial and quasi-steady regimes, (ii) Lees--Edwards-style methods for imposing shear, (iii) a Java-based graphical user interface (GUI) for setting up models and simulations, (iv) standardized XML formats for parametrization and data output, and (v) standardized formats VTK for continuum fields and microstructures. The SELM software package facilitates for pre-established models in LAMMPS easy adoption of the SELM fluctuating hydrodynamics thermostats. We offer here an overview of the SELM software package, computational methods, and applications.

97 MATHEMATICS AND COMPUTING↗

GrammarViz 3.0: Interactive Discovery of Variable-Length Time Series Patterns

The problems of recurrent and anomalous pattern discovery in time series, e.g., motifs and discords, respectively, have received a lot of attention from researchers in the past decade. However, since the pattern search space is usually intractable, most existing detection algorithms require that the patterns have discriminative characteristics and have its length known in advance and provided as input, which is an unreasonable requirement for many real-world problems. In addition, patterns of similar structure, but of different lengths may co-exist in a time series. In order to address these issues, we have developed algorithms for variable-length time series pattern discovery that are based on symbolic discretization and grammar inference—two techniques whose combination enables the structured reduction of the search space and discovery of the candidate patterns in linear time. In this work, we present GrammarViz 3.0—a software package that provides implementations of proposed algorithms and graphical user interface for interactive variable-length time series pattern discovery. The current version of the software provides an alternative grammar inference algorithm that improves the time series motif discovery workflow, and introduces an experimental procedure for automated discretization parameter selection that builds upon the minimum cardinality maximum cover principle and aids the time series recurrent and anomalous pattern discovery.

97 MATHEMATICS AND COMPUTING↗

PETSc DMNetwork: A Library for Scalable Network PDE-Based Multiphysics Simulations

We present DMNetwork, a high-level package included in the PETSc library for the simulation of multiphysics phenomena over large-scale networked systems. The library aims at applications that have networked structures such as those in electrical, gas, and water distribution systems. DMNetwork provides data and topology management, parallelization for multiphysics systems over a network, and hierarchical and composable solvers to exploit the problem structure. DMNetwork eases the simulation development cycle by providing the necessary infrastructure through simple abstractions to define and query the network components. This article presents the design of DMNetwork, illustrates its user interface, and demonstrates its ability to solve multiphysics systems, such as an electric circuit, a network of power grid and water subnetworks, and transient hydraulic systems over large networks with more than 2 billion variables on extreme-scale computers using up to 30,000 processors.

extreme-scale computing↗