Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Split-Step Simulations to Assess the Effects of Atmospheric Boundary Layer Turbulence on the Dose Variability of N-Waves and Shaped Booms

The effects of atmospheric boundary layer turbulence on the loudness variability of a sonic boom N-wave and shaped boom are examined with split-step simulations. The shaped boom is representative of a design iteration of the NASA X-59 aircraft. Inhomogeneous atmospheric boundary layer turbulence is generated in the computational domain by a Fourier synthesis method. The N-wave and shaped boom are propagated through turbulent fields representing eight different convection levels measured at the NASA Kennedy Space Center and the NASA Armstrong Flight Research Center. Probability density functions of the formation of caustic regions along the propagation direction are computed from the N-wave results, and a parameter to collapse the caustic PDFs that accounts for both fluctuation intensities and length scales is proposed. Statistical results concerning loudness metric variability are presented, and the standard deviations of several metrics are shown to collapse across different convection levels of turbulence for small nondimensional propagation distances. The loudness metric distributions are observed to be well approximated by a normal distribution for a given range of propagation distances, and become increasingly skewed as distance increases. A model function for the dose variability is proposed, and the function parameters are found to be related to the convection level of the turbulence. The model for the dose variability distribution is compared to simulation data that were not used to find the regression parameters of the model. At several nondimensional propagation distances, agreement is observed between the model and the simulation data. These results indicate that the model may be suitable for providing quick estimates of noise dose variability in the primary carpet region across a wide range of atmospheric boundary layer conditions.

Sonic boom↗

Differential Saccade-Pursuit Coordination Under Sleep Loss and Low-Dose Alcohol

Introduction: Ocular tracking of a moving object requires tight coordination between smooth pursuit and saccadic eye movements. Normally, pursuit drives gaze velocity to closely match target velocity, with residual position offsets corrected by catch-up saccades. However, how/if common stressors affect this coordination is largely unknown. This study seeks to elucidate the effects of acute and chronic sleep loss, and low-dose alcohol, on saccade-pursuit coordination, as well as that of caffeine. Methods: We used an ocular tracking paradigm to assess three metrics of tracking (pursuit gain, saccade rate, saccade amplitude) and to compute “ground lost” (from reductions in steady-state pursuit gain) and “ground recouped” (from increases in steady-state saccade rate and/or amplitude). We emphasize that these are measures of relative changes in positional offsets, and not absolute offset from the fovea. Results: Under low-dose alcohol and acute sleep loss, ground lost was similarly large. However, under the former, it was nearly completely recouped by saccades, whereas under the latter, compensation was at best partial. Under chronic sleep restriction and acute sleep loss with a caffeine countermeasure, the pursuit deficit was dramatically smaller, yet saccadic behavior remained altered from baseline. In particular, saccadic rate remained significantly elevated, despite the fact that ground lost was minimal. Discussion: This constellation of findings demonstrates differential impacts on saccade-pursuit coordination with low-dose alcohol impacting only pursuit, likely through extrastriate cortical pathways, while acute sleep loss not only disrupts pursuit but also undermines saccadic compensation, likely through midbrain/brainstem pathways. Furthermore, while chronic sleep loss and caffeine-mitigated acute sleep loss show little residual pursuit deficit, consistent with uncompromised cortical visual processing, they nonetheless show an elevated saccade rate, suggesting residual midbrain and/or brainstem impacts.

smooth pursuit↗

PE99155 Point-Of-Load Buck Regulator Total Ionizing Dose Test Report

Teledyne’s PE99155 point-of-load buck regulator was tested to evaluate an applicationspecific question about the start-up behavior of the device. This test determined if accumulated total ionizing dose (TID) affected any start-up voltage transient characteristics. Testing was based on pass/fail criterial for the magnitude of the output voltage to ensure the safety of downstream electronics. Two sets of radiation tests were performed. The first group of PE99155s used a high dose rate (HDR) irradiation to 25 krad(Si). A second group of PE99155s used high dose rate irradiation to 30 krad(Si).

TID↗

Total Ionizing Dose Test Report Microchip JANTXV2N6284 NPN Darlington Power Si Transistor

This study was undertaken to determine the effects of total ionizing dose (TID) on the JANTXV2N6284 NPN Darlington power bipolar junction transistor (BJT). The device was parametrically characterized prior to, at each incremental dose step, and after irradiation. Testing was at a low-dose rate using the NASA GSFC Radiation Effects Facility (REF).

Kaitlyn L Ryder↗

Comparison of residual dose rates from MARS and DORIAN simulations with experimental data from the SINBAD database

This benchmarking study aims to compare residual dose rate predictions from the MARS and DORIAN codes with experimental measurements taken from samples irradiated at CERN's CERF facility. The research evaluates the residual dose rates of these samples over varied cooling intervals. Additionally, it delves into the influence of parameter choices, such as specific physics processes and energy thresholds, on the production and transport of particles and their effects on simulation outcomes. While both MARS and DORIAN largely align with experimental findings, discrepancies were observed in the copper sample. This prompted an in-depth examination of the elevated dose rates from MARS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

US EPA Superfund Remediation Program Update: Revisions to Risk and Dose Assessment Models - 20368

The U.S. Environmental Protection Agency (EPA) Superfund remedial program is finishing up a significant number of revisions to its guidance for the risk assessment process at radioactively contaminated Superfund sites. The six Preliminary Remediation Goal (PRG) and Dose Compliance Concentration (DCC) internet-based calculators for radiation risk and dose assessment at Superfund sites are being reformatted to match the chemical calculators and improve the user experience, revised to add a new peak risk and dose output option, and to add some adjustment options for external exposure. A new Radon Vapor Intrusion Screening Level (RVISL) calculator is expected to be finished in 2020, will be similar to the Vapor Intrusion Screening Level (VISL) for chemical calculator that was finished in 2018. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of RESRAD and GoldSim Models for Assessing Radiological Dose for a RCRA Landfill - 20418

US Ecology Idaho (USEI) operates a Resource Conservation and Recovery Act (RCRA) Subtitle C, Hazardous Waste Treatment, Storage, and Disposal (TSD) Facility on a 640-acre property in Owyhee County, Idaho. USEI accepts a wide variety of RCRA-exempt low activity radioactive wastes, including naturally occurring radioactive material (NORM) and technologically enhanced NORM (TENORM) (USEI 2009). The performance of the landfill with regard to radiological operating permit requirements was previously assessed using a model constructed with the residual radioactivity (RESRAD) computer program, developed by Argonne National Laboratory for the U.S. Department of Energy (DOE). RESRAD supports the evaluation of several environmental transport pathways related to a radionuclide-contaminated soil source term, but it was not conceived as a model for the evaluation of landfill radiological performance. A more comprehensive and realistic model is desired in order to better support submissions to both the State of Idaho's Department of Environmental Quality as well as the U.S. Nuclear Regulatory Commission. A Performance Assessment (PA) computer model was developed using GoldSim software for the USEI RCRA Subtitle C landfill. The RESRAD computer model was specifically developed for calculating soil cleanup criteria and radiological dose and cancer risk from residual radioactive material in soil. To evaluate site-specific conditions, users may select from among a number of available environmental transport and exposure pathways and modify 'default' parameter values. In GoldSim, a user must construct the model 'from scratch.' However, this modeling is facilitated by a number of specialized elements available in GoldSim to support a radiological mass transport model. These include elements for defining radiological decay and ingrowth, container failure and radiological release, advective and diffusive transport, and other processes. Advantages afforded by the use of RESRAD for modeling radiological dose for a RCRA Subtitle C landfill include ease of use and reasonable flexibility in specifying site-specific conditions. GoldSim allows for considerably more flexibility and site-specificity than RESRAD, including evaluation of potentially relevant environmental transport processes not supported in RESRAD. The probabilistic modeling capabilities of GoldSim also far exceed those of RESRAD. The pros and cons of RESRAD and GoldSim for this modeling problem are explored with a focus on identifying approaches and critical factors in identifying the appropriate platform. The capabilities of RESRAD and GoldSim for mathematically modeling the disposal system will be contrasted and compared. For example, the existing RESRAD radiological safety assessment evaluated potentially complete exposure pathways related to infiltration to groundwater and upwards diffusion of radon. Additional transport pathways identified in the USEI Idaho facility Conceptual Site Model include deposition of radon decay products in cover material, root uptake of radionuclides in disposed wastes by native plants, and mixing of cover material by burrowing animals. Results of the two models and how the different transport and dose pathways affect results will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spinal Cord Dose Tolerance to Stereotactic Body Radiation Therapy

Spinal cord tolerance data for stereotactic body radiation therapy (SBRT) were extracted from published reports, reviewed, and modelled. For de novo SBRT delivered in 1 to 5 fractions, the following spinal cord point maximum doses (D{sub max}) are estimated to be associated with a 1% to 5% risk of radiation myelopathy (RM): 12.4 to 14.0 Gy in 1 fraction, 17.0 Gy in 2 fractions, 20.3 Gy in 3 fractions, 23.0 Gy in 4 fractions, and 25.3 Gy in 5 fractions. For reirradiation SBRT delivered in 1 to 5 fractions, reported factors associated with a lower risk of RM include cumulative thecal sac equivalent dose in 2 Gy fractions with an alpha/beta of 2 (EQD2{sub 2}) D{sub max} ≤70 Gy; SBRT thecal sac EQD2{sub 2} D{sub max} ≤25 Gy, thecal sac SBRT EQD2{sub 2} D{sub max} to cumulative EQD2{sub 2} D{sub max} ratio ≤0.5, and a minimum time interval to reirradiation of ≥5 months. Larger studies containing complete institutional cohorts with dosimetric data of patients treated with spine SBRT, with and without RM, are required to refine RM risk estimates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Response Relationship in Stereotactic Body Radiation Therapy for Hepatocellular Carcinoma: A Pooled Analysis of an Asian Liver Radiation Therapy Group Study

Despite the worldwide implementation of stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC), there is a lack of consensus guideline on prescription dose. Herein, this multinational study aimed to investigate the effects of the prescribed radiation dose on oncologic outcomes of SBRT for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PUFFIn – A user friendly fast interface for calculating and visualizing the dose distribution in materials

This article describes a new graphical user interface that uses the PENELOPE Monte Carlo code to calculate dose distributions in materials. It is named PUFFIn, for the Penelope User-Friendly Fast Interface and was developed as an educational and scoping analysis tool for non-experts in radiation modeling. PUFFIn enables the user to visualize and compare the dose distributions in objects (e.g., sterilized healthcare products) irradiated with cobalt-60 gamma-rays, electron beam (E-beam) or X-rays. From such comparisons, the user can determine the most efficient product and/or packaging designs for any given radiation field – whether for conceptual or existing products and packaging. PUFFIn is distributed in a complete, self-contained package of software, including the PENELOPE radiation transport code, a standard graphics package, and a set of simple exercises. The package is available to any user at no cost and requires a minimal amount of training compared to other similar software. PUFFIn's capabilities are described, as well as validation measurements performed at Texas A&M University E-beam facility and the Aerial E-beam Facility in France.

97 MATHEMATICS AND COMPUTING↗

Total Ionizing Dose Test Report for the UC1823A Pulse Width Modulator

The purpose of this study is to examine the total ionizing dose susceptibility for the UC1823A pulse width modulator manufactured by Texas Instruments, Inc. The part is suspected to be vulnerable to enhanced low dose rate sensitivity (ELDRS).

enhanced low dose rate sensitivity (ELDRS↗

Avalanche ASV016204 (Pre-Production Samples) 40nm MRAM Total Ionizing Dose Test Report

The purpose of this test was to characterize the Avalanche Technology ASV016204’s total dose response. In the test, the device was exposed to high dose rate (HDR) irradiations using gamma radiation. Device functionality (in terms of memory cell upsets and read/write ability) as well as power supply currents during various modes of operations were recorded.

Total Ionizing Dose (TID)↗

Updated Noise Dose Range of NASA’s X-59 Aircraft Estimated from Propagation Simulations

A follow-on study to Doebler and Loubeau, “The noise dose range of the X-59 estimated from propagation simulations,” JASA 150(4), A208 (2021); doi:10.1121/10.0008134 is described. In the previous work, propagation simulations of NASA’s X-59 sonic thump were conducted using two near-field pressure solutions from NASA’s Cart3D computational fluid dynamics (CFD) code. The near-fields were propagated through realistic atmospheric profiles from the Climate Forecast System Version 2 database across the USA, and Perceived Level statistics of the thumps were presented. The current work repeats the previous analyses, instead using near-field CFD solutions from NASA’s Fully Unstructured Navier-Stokes (FUN3D) code for the same aircraft conditions (Mach 1.4 at 53,200 feet and Mach 1.3 at 43,000 feet), which achieve the minimum and maximum cruise loudness. NASA and contractors in the X-59 development and community noise testing project mutually agreed upon using FUN3D for generating near-field pressures. Sonic thump loudness statistics using the FUN3D near-fields are similar to those of Cart3D. The min loudness condition is about 1 dB (PL) greater when using the FUN3D solution, and the max loudness condition results are nearly identical. Understanding the X-59’s dose range for various flight and atmospheric conditions is important for planning X-59 community noise surveys.

X-59↗

Temperature and dose effects on dislocation loops in self-ion irradiated high-purity iron

Body-centered cubic (BCC) Fe-based alloys are promising candidate materials for advanced nuclear reactors. However, a detailed understanding of irradiation induced dislocation loop microstructure development remains unresolved. It is a widespread belief that 〈001〉 loops become increasingly favorable over ½〈111〉 loops as irradiation temperature rises above ∼300 C. Unfortunately, the temperature effects on 〈001〉 loop have been primarily examined in in-situ irradiation on TEM thin foils but poorly explored on bulk Fe due to exceedingly limited experimental studies on bulk specimens, raising concerns about the potential influence of TEM thin foil artifacts on observed results. Here, in this study, we conducted experiments on ultra-high purity BCC Fe specimens irradiated with 6.7–8 MeV Fe ions over a wide temperature range on bulk samples. We investigated the effects of temperature (T irr = 250–500 °C), dose rate (10⁻⁵ to 10⁻³ dpa/s), and dose (0.35 to 3.5 dpa) on the formation and evolution of 〈001〉 and ½〈111〉 loops as well as cavity (void) formation. Post-irradiation Burgers vector analysis via g•b method on dislocation segments and loops revealed that 〈001〉 loop fraction does not show a monotonic positive correlation with irradiation temperature. Combined with previous and current theoretical as well as experimental findings, we explore the temperature effects on all existing models of 〈001〉 loop formation. We conclude that the prevailing reports regarding the dominance of 〈001〉 loops in Fe at elevated temperatures are mainly attributable to the loss of glissile ½〈111〉 clusters in TEM thin foil experiments.

36 MATERIALS SCIENCE↗

Phase 1 Study of Low-Dose Fractionated Whole Abdominal Radiation Therapy in Combination With Weekly Paclitaxel for Platinum-Resistant Ovarian Cancer (GCGS-01)

Low-dose fractionated whole abdominal radiation therapy (LDFWART) has synergistic activity with paclitaxel in preclinical models. The aim of this phase 1 trial was to determine the recommended phase 2 dose and preliminary activity of weekly paclitaxel (wP) concurrent with LDFWART in patients with platinum-resistant ovarian cancer (PROC).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Phase 2 Study of Radiation Therapy Dose and Volume De-escalation for Elective Neck Treatment of Oropharyngeal and Laryngeal Cancer

The required elective nodal dose and volumes for head and neck intensity modulated radiation therapy have largely been extrapolated from conventional radiation therapy fields. In this prospective, dual-center, phase 2 study, we investigated the efficacy and tolerability of reduced elective nodal volume and dose in oropharyngeal and laryngeal squamous cell carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗