Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Performance Results for Sensor Assignment Problem as Solved on a Multi-Node Cluster

An earlier report described a procedure for optimal sensor set selection and its implementation on a computational cluster. This new and innovative capability was developed to facilitate a reduction in operations staffing levels to improve plant economics. By automating surveillance and maintenance tasks through early detection of degrading sensors and equipment, staff can be more efficiently deployed. The method uses automated reasoning and domain knowledge in the form of the conservation equations to infer from plant measurements the state of equipment health. Inclusion of domain knowledge addresses the problem that exists with pure data-driven methods that there are no rigorous guidelines for determining what constitutes an adequate sensor set. Formalizing the procedure for sensor set selection as we have done results in a more reliable and explainable diagnosis of plant equipment health. Importantly, from the standpoint of the plant owner, personnel are provided with an early and explicit diagnosis of an equipment problem. That in principle automates the process and eliminates having to send personnel into the plant to find the cause as typically occurs when a data-driven method detects an anomaly. In this report we describe first results obtained using a computational cluster to solve the sensor set selection problem as framed above. The case described addresses the problem of equipment health monitoring in the high-pressure (HP) feedwater system of a pressurized light water reactor as seen through the eyes of our collaborating utility partner. Maintenance of this system can amount to millions of dollars per year if equipment health issues go undiagnosed and lead to loss of function. On examining the potential that is inherent in the installed sensor set for diagnosing equipment health degradation, it was found that greater fault resolution capability can be achieved using a sensor set that is 20 percent fewer in number. The take-away is that compared to the installed sensor set there exists a more strategic assignment of sensors that will furnish better health monitoring capability and with fewer sensors. Where the problem defies solution by manual inspection, as is the case here, one can be found by an algorithm. The solution was obtained in four hours using 30 computational cores. The HP feedwater problem as posed above illustrates the added value of approaching the sensor selection problem as one amenable to algorithmic solution. This problem is of interest to advanced reactor designers and to utilities that are setting up remote monitoring and diagnostic centers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contextually aware roadside radiation measurement testbed

Here we demonstrate a contextually aware multimodal roadside radiation measurement detection testbed for traffic monitoring applications in nuclear nonproliferation. Many variables in traffic such as vehicle or cargo size, mass, speed, shape, and distance of closest approach can have significant impacts on the radiation measured from a vehicle-transported radiation source. These factors can lead to uncertainties in the analysis of the radiation source, especially for lower-strength radiation sources of interest. Our testbed, known as the Multimodal Measurement System (MMS) uses non-radiation sensors including magnetometers, geophones, radiofrequency receivers, cameras, and LiDAR to extract contextual information about vehicles passing by the system. These contextual data can then be fused with data from radiation measurements to increase the system’s sensitivity and accuracy in nuclear threat detection applications. This work describes the instrumentation of the MMS and its data acquisition pipeline. Furthermore, we describe the pre-analysis performed on the raw multimodal data streams for data fusion, and the high-level machine learning analyses for detection and characterization. The variety of sensors within the MMS provides a valuable testbed that can be used to identify the combinations of contextual sensors that provide the greatest improvements to radiation source detection and characterization within the restrictions for various proliferation detection applications. The MMS is also modular so that additional combinations of sensors can be explored in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

Sensor-Based Energy Modeling (sBEM) D4: Final report

Four residential demonstration homes have been built as part of the ZEBRAlliance and fully instrumented with 50+ sensors collecting 1-minute data and 190+ sensors collecting 15-minute data (over 250 sensors total) with the first year’s worth of data for two houses collected in January, 2011. This sensor data will be mined to develop predictive models of component-level and whole-building energy consumption by utilizing machine-learning techniques in a way that circumvents problems with typical white-box modeling approaches (faulty/time-consuming input building models, energy simulation assumptions, and contractor variability in as-built results). Such a system would constitute an objective, quantitative framework whereby raw sensor data is utilized to determine both a prediction, and thus a variance (i.e. within 10% of predicted 80% of the time), for energy consumption by a residential building. Furthermore, analysis will be conducted to determine the predictive accuracy for a smaller number of sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring impacts of California agri-environmental programs using field-scale satellite data

In the past decade, California has invested over $\$$200 million in direct grants to growers to support the adoption of agricultural practices that save water and/or improve soil health while also reducing greenhouse gas emissions. Ex-post evaluation of agri-environmental outcomes of these grant programs, however, is limited. We use satellite data to monitor changes in field-level consumptive water use and greenness (i.e. normalized difference vegetation index), a proxy for agricultural productivity, for the most frequently funded crop-types (almonds, grapes, and walnuts) in two California Department of Food and Agriculture programs. Nearly 600 fields receiving funding during the 2014–2022 period were analyzed using two causal inference methods. Fields that received grants to both upgrade irrigation systems and install irrigation water management sensors showed reduced consumptive water use and greenness by an average of 3.5% and 4.2%, respectively (significant at the 10% level). In contrast, we find that the adoption of only irrigation water management sensors, which are designed to inform irrigation scheduling and management, resulted in an average increase of 4.1% and 4.8% in consumptive water use and greenness respectively (significant at the 5% level). We find negligible effects for either consumptive water use or greenness when both pump efficiency upgrades and sensors were implemented. We further find that grants for compost addition and cover cropping led to small greenness increases of 1.7% and 2.8% respectively (significant at the 10% level) and had insignificant effects on consumptive water use. Our analysis of five agri-environmental program interventions reveals that several practice outcomes may be at odds with stated program goals of reducing water use while maintaining or improving agricultural productivity.

agriculture↗

Estimation and Fusion for Tracking Over Long-Haul Links Using Artificial Neural Networks

In a long-haul sensor network, sensors are remotely deployed over a large geographical area to perform certain tasks, such as tracking and/or monitoring of one or more dynamic targets. A remote fusion center fuses the information provided by these sensors so that a final estimate of certain target characteristics – such as the position – is expected to possess much improved quality. In this paper, we pursue learning-based approaches for estimation and fusion of target states in longhaul sensor networks. In particular, we consider learning based on various implementations of artificial neural networks (ANNs). Finally, the joint effect of (i) imperfect communication condition, namely, link-level loss and delay, and (ii) computation constraints, in the form of low-quality sensor estimates, on ANN-based estimation and fusion, is investigated by means of analytical and simulation studies.

97 MATHEMATICS AND COMPUTING↗

Indoor Occupancy Sensing via Networked Nodes (2012–2022): A Review

In the past decade, different sensing mechanisms and algorithms have been developed to detect or estimate indoor occupancy. One of the most recent advancements is using networked sensor nodes to create a more comprehensive occupancy detection system where multiple sensors can identify human presence within more expansive areas while delivering enhanced accuracy compared to a system that relies on stand-alone sensor nodes. The present work reviews the studies from 2012 to 2022 that use networked sensor nodes to detect indoor occupancy, focusing on PIR-based sensors. Methods are compared based on pivotal ADPs that play a significant role in selecting an occupancy detection system for applications such as Health and Safety or occupant comfort. These parameters include accuracy, information requirement, maximum sensor failure and minimum observation rate, and feasible detection area. We briefly describe the overview of occupancy detection criteria used by each study and introduce a metric called “sensor node deployment density” through our analysis. This metric captures the strength of network-level data filtering and fusion algorithms found in the literature. It is hinged on the fact that a robust occupancy estimation algorithm requires a minimal number of nodes to estimate occupancy. This review only focuses on the occupancy estimation models for networked sensor nodes. It thus provides a standardized insight into networked nodes’ occupancy sensing pipelines, which employ data fusion strategies, network-level machine learning algorithms, and occupancy estimation algorithms. This review thus helps determine the suitability of the reviewed methods to a standard set of application areas by analyzing their gaps.

Emad-Ud-Din, Muhammad (ORCID:0000000279515538)↗

SULI Research Report Paper

Hybrid-CMOS (hCMOS) nanosecond x-ray imagers are a powerful timeresolved HED (high-energy-density) diagnostic due to their sensitivity to visible light, x-rays, and charged particles. However, significant pseudosinusoidal background oscillations have been observed in these sensors when exposed to an early incident excitation, a phenomenon that has been experimentally linked the sensor’s bond wire inductance. We analyze the oscillations both in the time domain and spatially to account for variations on the pixel level. Both theoretical techniques and analysis of experimental data have shown that the oscillations are a global sensor phenomenon. In addition, we effectively describe the oscillations with a physics-based model, giving further insight into the processes affecting them. This technique allows the hCMOS user to subtract out the oscillations from their measurements and improve accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards intrinsic MoS{sub 2} devices for high performance arsenite sensing

Molybdenum disulphide (MoS{sub 2}) is one of the most attractive two dimensional materials other than graphene, and the exceptional properties make it a promising candidate for bio/chemical sensing. Nevertheless, intrinsic properties and sensing performances of MoS{sub 2} are easily masked by the presence of the Schottky barrier (SB) at source/drain electrodes, and its impact on MoS{sub 2} sensors remains unclear. Here, we systematically investigated the influence of the SB on MoS{sub 2} sensors, revealing the sensing mechanism of intrinsic MoS{sub 2}. By utilizing a small work function metal, Ti, to reduce the SB, excellent electrical properties of this 2D material were yielded with 2–3 times enhanced sensitivity. We experimentally demonstrated that the sensitivity of MoS{sub 2} is superior to that of graphene. Intrinsic MoS{sub 2} was able to realize rapid detection of arsenite down to 0.1 ppb without the influence of large SB, which is two-fold lower than the World Health Organization (WHO) tolerance level and better than the detection limit of recently reported arsenite sensors. Additionally, accurately discriminating target molecules is a great challenge for sensors based on 2D materials. This work demonstrates MoS{sub 2} sensors encapsulated with ionophore film which only allows certain types of molecules to selectively permeate through it. As a result, multiplex ion detection with superb selectivity was realized. Our results show prominent advantages of intrinsic MoS{sub 2} as a sensing material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber Optic Instrumentation in High Temperature Irradiation Environments

The extremely harsh conditions of advanced reactor designs pose serious challenges for nuclear fuels and materials. Traditional instrumentation (thermocouples, strain gauges, etc.) are not well suited for extended operation in such a harsh environment. This work discusses the potential for using fiber optic-based instrumentation in high temperature irradiation experiments. The primary limitation of fiber optic instrumentation in irradiation experiments is signal darkening due to attenuation in the fiber material. A computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Preliminary results obtained using this model are shown for one cycle of irradiation in the high flux isotope reactor at various temperatures. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose in order to validate the predictive model. Demonstration of the safety and reliability of new and enhanced nuclear fuels and materials is essential for improving the safety and reliability of existing nuclear power plants and for the licensing and operation of advanced nuclear reactor technologies. Experimental validation of fuel performance codes requires high fidelity measurements during instrumented irradiation experiments. Therefore, a clear need exists for sensors of unprecedented accuracy, resolution, time/space/energy spectrum dependence, reduced size, and, perhaps most importantly, performance in harsh environments. The harsh environment during accelerated irradiation testing could include temperatures from 300 deg. C up to 2600 deg. C, and radiation damage levels ranging from 1 to greater than 100 dpa. Optical fiber-based sensors are a promising candidate for instrumentation in high temperature irradiation environments. Optical fibers are small, inexpensive, chemically inert, immune to electromagnetic interference, and made of high temperature radiation-hard materials. The ability to make distributed measurements of temperature or strain using a single inexpensive optical fiber currently exists for non-extreme environments as commercially available technology. Other advanced sensing technologies such as laser ultrasound, borescopes, and laser-induced breakdown spectroscopy use fiber optic light delivery as a critical component of the sensor design. Some potential applications for optical fiber-based sensors in instrumented irradiation experiments include in-situ measurements of thermal conductivity, ultrasonic measurement of elastic constants (with fiber optic delivery of signal for generation and detection of ultrasonic wave), and distributed measurements of temperature and/or strain (i.e., swelling). The primary limitation for the use of optical technologies for harsh environment (e.g., high neutron flux reactor environments) instrumentation is the attenuation of the light signal due to the effects of temperature and/or irradiation. This work summarizes initial efforts towards developing a predictive model of temperature-dependent radiation-induced attenuation in fused silica optical fibers at high dose. If there is adequate transmission in the fibers, fiber optic-based instrumentation could provide highly accurate distributed measurements during instrumented fuel/material irradiation experiments. Preliminary results show attenuation on the order of 5- 10 dB/m in the wavelength range of 750-900 nm at temperatures of 300 deg. C and below after one HFIR cycle (24 days). At higher temperatures (600 and 900 deg. C), the attenuation is reduced below 5 dB/m in the same wavelength range. This amount of attenuation is acceptable for most fiber optic based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high flux region. Many optical components use a wavelength of 850 nm, which lies in the low attenuation window. In order to refine and ultimately validate the predictive model of optical fiber attenuation, a reactor irradiation campaign has been initiated. Rabbit irradiation capsules have been designed to irradiate optical fiber material (low and high OH fused silica, as well as single crystal sapphire) specimens in the HFIR at temperatures ranging from 100 to 1200 deg. C. (authors)

42 ENGINEERING↗

Magnetically induced enhancement of reversibly responding conductometric sensors

Small magnetic fields are found to greatly enhance the reversible room temperature conductometric responses of n and p- type porous silicon (PS) interfaces, treated with nanostructured island sites containing paramagnetic Co(II) and Fe(II). At concentrations sufficiently low so as to avoid cross talk between the nanostructured island sites, the response to NO concentrations demonstrates the significant effect which the Co(II) and Fe(II) have on the decorated extrinsic semiconductor majority charge carriers as they direct a dominant electron transduction process for reversible electron transduction and chemical sensing (Inverse Hard and Soft acid/base principle) in the absence of significant chemical bond formation. Co(II) and Fe(II) oxide sites enhance response and provide a means for small magnetic fields to interact with and enhance the sensor interface response. For p-type systems, the interaction is with small virtually constant thermal electron populations lying above the Fermi energy at 0 K. The electron removal rate increases with magnetic field strength. At the highest magnetic fields and NO analyte concentrations the available electron population is depleted, and the response to the analyte decreases at higher concentrations. At lower magnetic fields (<1000 G), the response faithfully follows concentration. For n-type systems, the magnetic field interaction increases resistance. This increase in response may be attributed to the interaction with donor levels ∼0.025 eV below the conduction band. A substantial enhancement of sensor response relative to that for the Co(II) and Fe(II) treated PS interfaces is observed, with the introduction of a small magnetic field greatly increasing an already enhanced conductometric response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

QA/QC-ed Groundwater Level Time Series in PLM-1 and PLM-6 Monitoring Wells, East River, Colorado (2016-2022)

This data set contains QA/QC-ed (Quality Assurance and Quality Control) water level data for the PLM1 and PLM6 wells. PLM1 and PLM6 are location identifiers used by the Watershed Function SFA project for two groundwater monitoring wells along an elevation gradient located along the lower montane life zone of a hillslope near the Pumphouse location at the East River Watershed, Colorado, USA. These wells are used to monitor subsurface water and carbon inventories and fluxes, and to determine the seasonally dependent flow of groundwater under the PLM hillslope. The downslope flow of groundwater in combination with data on groundwater chemistry (see related references) can be used to estimate rates of solute export from the hillslope to the floodplain and river. QA/QC analysis of measured groundwater levels in monitoring wells PLM-1 and PLM-6 included identification and flagging of duplicated values of timestamps, gap filling of missing timestamps and water levels, removal of abnormal/bad and outliers of measured water levels. The QA/QC analysis also tested the application of different QA/QC methods and the development of regular (5-minute, 1-hour, and 1-day) time series datasets, which can serve as a benchmark for testing other QA/QC techniques, and will be applicable for ecohydrological modeling. The package includes a Readme file, one R code file used to perform QA/QC, a series of 8 data csv files (six QA/QC-ed regular time series datasets of varying intervals (5-min, 1-hr, 1-day) and two files with QA/QC flagging of original data), and three files for the reporting format adoption of this dataset (InstallationMethods, file level metadata (flmd), and data dictionary (dd) files).QA/QC-ed data herein were derived from the original/raw data publication available at Williams et al., 2020 (DOI: 10.15485/1818367). For more information about running R code file (10.15485_1866836_QAQC_PLM1_PLM6.R) to reproduce QA/QC output files, see README (QAQC_PLM_readme.docx). This dataset replaces the previously published raw data time series, and is the final groundwater data product for the PLM wells in the East River. Complete metadata information on the PLM1 and PLM6 wells are available in a related dataset on ESS-DIVE: Varadharajan C, et al (2022). https://doi.org/10.15485/1660962. These data products are part of the Watershed Function Scientific Focus Area collection effort to further scientific understanding of biogeochemical dynamics from genome to watershed scales. 2022/09/09 Update: Converted data files using ESS-DIVE’s Hydrological Monitoring Reporting Format. With the adoption of this reporting format, the addition of three new files (v1_20220909_flmd.csv, V1_20220909_dd.csv, and InstallationMethods.csv) were added. The file-level metadata file (v1_20220909_flmd.csv) contains information specific to the files contained within the dataset. The data dictionary file (v1_20220909_dd.csv) contains definitions of column headers and other terms across the dataset. The installation methods file (InstallationMethods.csv) contains a description of methods associated with installation and deployment at PLM1 and PLM6 wells. Additionally, eight data files were re-formatted to follow the reporting format guidance (er_plm1_waterlevel_2016-2020.csv, er_plm1_waterlevel_1-hour_2016-2020.csv, er_plm1_waterlevel_daily_2016-2020.csv, QA_PLM1_Flagging.csv, er_plm6_waterlevel_2016-2020.csv, er_plm6_waterlevel_1-hour_2016-2020.csv, er_plm6_waterlevel_daily_2016-2020.csv, QA_PLM6_Flagging.csv). The major changes to the data files include the addition of header_rows above the data containing metadata about the particular well, units, and sensor description. 2023/01/18 Update: Dataset updated to include additional QA/QC-ed water level data up until 2022-10-12 for ER-PLM1 and 2022-10-13 for ER-PLM6. Reporting format specific files (v2_20230118_flmd.csv, v2_20230118_dd.csv, v2_20230118_InstallationMethods.csv) were updated to reflect the additional data. R code file (QAQC_PLM1_PLM6.R) was added to replace the previously uploaded HTML files to enable execution of the associated code. R code file (QAQC_PLM1_PLM6.R) and ReadMe file (QAQC_PLM_readme.docx) were revised to clarify where original data was retrieved from and to remove local file paths.

54 ENVIRONMENTAL SCIENCES↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hyundai Avante LPi hybrid level 1 testing report

In collaboration with the Korea Automotive Technology Institute (KATECH), the Korean market only Hyundai Avante LPi Hybrid was purchased and imported to ANL's Advanced Powertrain Research Facility for vehicle-level testing. Data was acquired during testing using non-intrusive sensors, vehicle network information, and facilities equipment (emissions and dynamometer). Standard drive cycles, performance cycles, steady-state cycles, and A/C usage cycles were conducted. The major results are shown in this report. Given the benchmark nature of this assessment, the majority of the testing was done over standard regulatory cycles and sought to obtain a general overview of how the vehicle performs. These cycles include the US FTP cycle (Urban) and Highway Fuel Economy Test cycle as well as the US06, a more aggressive supplemental regulatory cycle. To assess the impacts of more aggressive driving, the LA92 cycle and a UDDS scaled by a factor 1.2x cycles were also included in the testing plan. Data collection for this testing was kept at a fairly high level and includes emissions and fuel measurements from an exhaust emissions bench, high-voltage and accessory current/voltage from a DC power analyzer, and CAN bus data such as engine speed. The following sections will seek to explain some of the basic operating characteristics of the Avante LPi Hybrid and provide insight into unique features of its operation and design. Figure 1 shows the test vehicle in Argonne's soak room.

33 ADVANCED PROPULSION SYSTEMS↗

Development of a formaldehyde biosensor with application to synthetic methylotrophy

Formaldehyde is a prevalent environmental toxin and a key intermediate in single carbon metabolism. The ability to monitor formaldehyde concentration is, therefore, of interest for both environmental monitoring and for metabolic engineering of native and synthetic methylotrophs, but current methods suffer from low sensitivity, complex workflows, or require expensive analytical equipment. Here we develop a formaldehyde biosensor based on the FrmR repressor protein and cognate promoter of Escherichia coli . Optimization of the native repressor binding site and regulatory architecture enabled detection at levels as low as 1 µM. We then used the sensor to benchmark the in vivo activity of several NAD‐dependent methanol dehydrogenase (Mdh) variants, the rate‐limiting enzyme that catalyzes the first step of methanol assimilation. In order to use this biosensor to distinguish individuals in a mixed population of Mdh variants, we developed a strategy to prevent cross‐talk by using glutathione as a formaldehyde sink to minimize intercellular formaldehyde diffusion. Finally, we applied this biosensor to balance expression of mdh and the formaldehyde assimilation enzymes hps and phi in an engineered E. coli strain to minimize formaldehyde build‐up while also reducing the burden of heterologous expression. This biosensor offers a quick and simple method for sensitively detecting formaldehyde, and has the potential to be used as the basis for directed evolution of Mdh and dynamic formaldehyde control strategies for establishing synthetic methylotrophy.

Woolston, Benjamin M.↗

Measurement of advective soil gas flux: Results of field and laboratory experiments with CO2

We modified our multi-channel, steady-state flow-through (SSFT), soil-CO2 flux monitoring system to include an array of inexpensive pyroelectric non-dispersive infrared detectors for full-range (0-100%) coverage of CO2 concentrations without dilution, and a larger-diameter vent tube. We then conducted field testing of this system from late July through mid-September 2010 at the Zero Emissions Research and Technology (ZERT) project site located in Bozeman, MT, and subsequently, laboratory testing at the Pacific Northwest National Laboratory (PNNL) in Richland, WA using a flux bucket filled with dry sand. In the field, an array of twenty-five SSFT and three non-steady-state (NSS) flux chambers was installed in a 10x4 m area, the long boundary of which was directly above a shallow (2-m depth) horizontal injection well located 0.5 m below the water table. Two additional chambers (one SSFT and one NSS) were installed 10 m from the well for background measurements. Volumetric soil moisture sensors were installed at each SSFT chamber to measure mean levels in the top 0.15 m of soil. A total flux of 52 kg CO2 d-1 was injected into the well for 27 d and the efflux from the soil was monitored by the chambers before, during, and for 27 d after the injection. Overall, the results were consistent with those from previous years, showing a radial efflux pattern centered on a known “hot spot”, rapid responses to changes in injection rate and wind power, evidence for movement of the CO2 plume during the injection, and nominal flux levels from the SSFT chambers that were up to 6-fold higher than those measured by adjacent NSS chambers. Soil moisture levels varied during the experiment from moderate to near saturation with the highest levels occurring consistently at the hot spot. The effects of wind on measured flux were complex and decreased as soil moisture content increased. In the laboratory, flux bucket testing with the SSFT chamber showed large measured-flux enhancement due to the Venturi effect on the chamber vent, but an overall decrease in measured flux when wind also reached the sand surface. Flux-bucket tests at a high flux (comparable to that at the hot spot) also showed that the measured flux levels increase linearly with the chamber-flushing rate until the actual level is reached. At the SSFT chamber-flushing rate used in the field experiment the measured flux in the laboratory was only about a third of the actual flux. The ratio of measured to actual flux increased logarithmically as flux decreased, and reached parity at low levels typical of diffusive flux systems. Taken together, our results suggest that values for advective CO2 flux measured by SSFT and NSS chamber systems are likely to be significantly lower than the actual values due to back pressure developed in the chamber that diverts flux from entering the chamber. Chamber designs that counteract the back pressure and also avoid large Venturi effects associated with vent tubes, such as the SSFT with a narrow vent tube operated at a high chamber-flushing rate, are likely to yield flux measurements closer to the true values.

carbon dioxide↗

Cold adaptation of the mononuclear molybdoenzyme periplasmic nitrate reductase from the Antarctic bacterium Shewanella gelidimarina

Highlights: Black-Right-Pointing-Pointer Cold-adapted phenotype of NapA from the Antarctic bacterium Shewanella gelidimarina. Black-Right-Pointing-Pointer Protein homology model of NapA from S. gelidimarina and mesophilic homologue. Black-Right-Pointing-Pointer Six amino acid residues identified as lead candidates governing NapA cold adaptation. Black-Right-Pointing-Pointer Molecular-level understanding of designing cool-temperature in situ oxyanion sensors. -- Abstract: The reduction of nitrate to nitrite is catalysed in bacteria by periplasmic nitrate reductase (Nap) which describes a system of variable protein subunits encoded by the nap operon. Nitrate reduction occurs in the NapA subunit, which contains a bis-molybdopterin guanine dinucleotide (Mo-MGD) cofactor and one [4Fe-4S] iron-sulfur cluster. The activity of periplasmic nitrate reductase (Nap) isolated as native protein from the cold-adapted (psychrophilic) Antarctic bacterium Shewanella gelidimarina (Nap{sub Sgel}) and middle-temperature adapted (mesophilic) Shewanella putrefaciens (Nap{sub Sput}) was examined at varied temperature. Irreversible deactivation of Nap{sub Sgel} and Nap{sub Sput} occurred at 54.5 and 65 Degree-Sign C, respectively. When Nap{sub Sgel} was preincubated at 21-70 Degree-Sign C for 30 min, the room-temperature nitrate reductase activity was maximal and invariant between 21 and 54 Degree-Sign C, which suggested that Nap{sub Sgel} was poised for optimal catalysis at modest temperatures and, unlike Nap{sub Sput}, did not benefit from thermally-induced refolding. At 20 Degree-Sign C, Nap{sub Sgel} reduced selenate at 16% of the rate of nitrate reduction. Nap{sub Sput} did not reduce selenate. Sequence alignment showed 46 amino acid residue substitutions in Nap{sub Sgel} that were conserved in NapA from mesophilic Shewanella, Rhodobacter and Escherichia species and could be associated with the Nap{sub Sgel} cold-adapted phenotype. Protein homology modeling of Nap{sub Sgel} using a mesophilic template with 66% amino acid identity showed the majority of substitutions occurred at the protein surface distal to the Mo-MGD cofactor. Two mesophilic {r_reversible} psychrophilic substitutions (Asn {r_reversible} His, Val {r_reversible} Trp) occurred in a region close to the surface of the NapA substrate funnel resulting in potential interdomain {pi}-{pi} and/or cation-{pi} interactions. Three mesophilic {r_reversible} psychrophilic substitutions occurred within 4.5 A of the Mo-MGD cofactor (Phe {r_reversible} Met, Ala {r_reversible} Ser, Ser {r_reversible} Thr) resulting in local regions that varied in hydrophobicity and hydrogen bonding networks. These results contribute to the understanding of thermal protein adaptation in a redox-active mononuclear molybdenum enzyme and have implications in optimizing the design of low-temperature environmental biosensors.

60 APPLIED LIFE SCIENCES↗