Search NASA⌕ Search

SEARCH · Search NASA

Results for “planted solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Data for Resourceful and Economical Designing of Fermentation Medium for Lab and Commercial Strains of Yeast from Alternative Feedstock: Transgenic Oilcane

Sugarcane plant engineered to accumulate lipids in its vegetative tissue is being developed as a new bioenergy crop. The new crop would be a source of juice, oil, and cellulosic sugars. However, limited tolerance of industrially recognized yeasts towards inhibitors generated during the processing of lignocellulosic biomass to produce fermentable sugars is a major challenge in developing scalable processes for second-generation drop-in fuel production. To this end, hydrolysates generated from engineered sugarcane—‘oilcane’ bagasse contain added phenolics and fatty acids that further restrict the growth of fermenting microorganisms and necessitate nutrient supplementation and/or detoxification of hydrolysate which makes the fermentation process expensive. Herein, we propose a resourceful and economical approach for growing lab and commercial strains of S. cerevisiae on unrefined cellulosic sugars aerobically and fermentatively. An equal ratio of hydrolysate and juice was found optimum for growth and fermentation by lab and commercial strains of Saccharomyces cerevisiae engineered for xylose fermentation. The industrial strain grew and fermented efficiently under low aeration conditions having an ethanol titer, yield, specific and volumetric productivities of 46.96 ± 0.19 g/l, 0.51 ± 0.00 g/g, 0.27 ± 0.02 g/g.h and 1.95 ± 0.01 g/l.h, respectively, while the lab strain grew better under higher aeration conditions having the ethanol titer, yield, specific and volumetric productivities of 24.93 ± 0.09, 0.27 ± 0.00 g/g, 0.17 ± 0.00 g/g.h and 1.04 ± 0.00 g/l.h, respectively. Acclimation of cultures in a blended medium significantly improved the performance of the yeast strains. The addition of transgenic oilcane juice, which is inedible and rich in amino acids, to the hydrolysate averted the need for expensive nutrient supplementation and detoxification steps of hydrolysate. The approach provides an economical solution to reduce the cost of fermentation at an industrial scale for second-generation drop-in fuel production.

Biomass Analytics↗

The Complexity and Challenges of Irradiation-Induced Phase Instability Phenomenon in Nuclear Power Plant Components

High energy irradiation by neutrons or ions of metastable austenitic 300-series steels appears to initiate formation of bcc-phases with different morphology and elemental composition compared to that of retained ferrite. Extensive formation of specific Fe-rich ferrite was observed on the grain boundaries of annealed Russian steel 12Cr18Ni10Ti, an analog of AISI 321, after irradiation in the center-core region of sodium-cooled BN-350 fast reactor (SFR) doses up to 57 dpa at ~1×10-6dpa/sec. The ferrite fraction determined from scanning electron microscopy (SEM) closely matched the magnetic fraction determined using a ferritscope confirmed by X-ray diffraction analysis and selected area diffraction patterns. Chemical composition of the secondary phases was determined by energy dispersive X-ray analysis using transmission electron microscope, showing Fe-rich ferrite domains. Fe-ion irradiation (2.3 MeV) was used to study the accumulation of ferrite and martensite phases at higher dpa rates. The very high etchability of these ferrite particles in alcohol-based solutions may signal a very high etching in hot water, leading to accelerated intergranular cracking, especially upon long-term exposure during extended plant lifetimes.

D a, Merezhko↗

Solutions Network Formulation Report. Reducing Light Pollution in U.S. Coastal Regions Using the High Sensitivity Cameras on the SAC-C and Aquarius/SAC-D Satellites

Light pollution has significant adverse biological effects on humans, animals, and plants and has resulted in the loss of our ability to view the stars and planets of the universe. Over half of the U.S. population resides in coastal regions where it is no longer possible to see the stars and planets in the night sky. Forty percent of the entire U.S. population is never exposed to conditions dark enough for their eyes to convert to night vision capabilities. In coastal regions, urban lights shine far out to sea where they are augmented by the output from fishing boat, cruise ship and oil platform floodlights. The proposed candidate solution suggests using HSCs (high sensitivity cameras) onboard the SAC-C and Aquarius/SAC-D satellites to quantitatively evaluate light pollution at high spatial resolution. New products modeled after pre-existing, radiance-calibrated, global nighttime lights products would be integrated into a modified Garstang model where elevation, mountain screening, Rayleigh scattering, Mie scattering by aerosols, and atmospheric extinction along light paths and curvature of the Earth would be taken into account. Because the spatial resolution of the HSCs on SAC-C and the future Aquarius/SAC-D missions is greater than that provided by the DMSP (Defense Meteorological Satellite Program) OLS (Operational Linescan System) or VIIRS (Visible/Infrared Imager/Radiometer Suite), it may be possible to obtain more precise light intensity data for analytical DSSs and the subsequent reduction in coastal light pollution.

Andrews, Jane C.↗

Relationship of attenuation in a vegetation canopy to physical parameters of the canopy

A discrete scatter model is employed to compute the radiometric response (i.e. emissivity) of a layer of vegetation over a homogeneous ground. This was done to gain insight into empirical formulas for the emissivity which have recently appeared in the literature and which indicate that the attenuation through the canopy is proportional to the water content of the vegetation and inversely proportional to wavelength raised to a power around unity. The analytical result assumes that the vegetation can be modeled by a sparse layer of discrete, randomly oriented particles (leaves, stalks, etc.). The attenuation is given by the effective wave number of the layer obtained from the solution for the mean wave using the effective field approximation. By using the Ulaby-El Rayes formula to relate the dielectric constant of the vegetation to its water content, it can be shown that the attenuation is proportional to water content. The analytical form offers insight into the dependence of the empirical parameters on other variables of the canopy, including plant geometry (i.e. shape and orientation of the leaves and stalks of which the vegetation is comprised), frequency of the measurement and even the physical temperature of the vegetation. Solutions are presented for some special cases including layers consisting of cylinders (stalks) and disks (leaves).

Karam, M. A.↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Plasma steering to avoid disruptions in ITER and tokamak power plants

Steering tokamak plasmas is commonly viewed as a way to avoid disruptions and runaway electrons. Plasma steering sounds as safe as driving to work but will be shown to more closely resemble driving at high speed through a dense fog on an icy road. The long time required to terminate an ITER discharge compared to time over which dangers can be foreseen is analogous to driving in a dense fog. Here, the difficulty of regaining plasma control if it is lost resembles driving on an icy road. Disruptions and runaways are associated with three issues—a solution to one tends to complicate the solution to the other two: loss of plasma position control, excessive heat deposition, and wall melting due to runaway electrons. All three risks must be addressed for ITER to achieve its mission and essentially eliminated before tokamak power plants can be deployed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing Desalination Operations for Energy Flexibility

Despite the value of energy optimization in desalination processes, modeling dynamic operations for monthly billing periods has remained a computational challenge. This work proposes a framework for energy flexibility optimization, which includes new modeling features for independent operation of parallel skids, start-up delays associated with chemical stabilization, the consideration of industrial energy tariff structures, and inclusion of hourly electrical carbon intensities. This is done using a modular and computationally efficient formulation that guarantees a globally optimal solution with standard optimization solvers. In this study, the approach is demonstrated in two distinct case studies: a seawater desalination plant in Santa Barbara, CA, and an indirect potable reuse facility in San Jose, CA. Trends predicted from the model are validated against operational facility measurements from a demand response shutdown event. Preliminary results show that optimizing energy flexibility can result in 18.51% monthly cost savings over energy efficiency-optimized operation. The value extracted from a facility-wide shutdown during peak electricity price hours is hampered by start-up delays in post-treatment chemical stabilization. In cases in which a facility does not have much excess capacity, using a flow equalization tank or operating over a wide recovery range may be cost-effective.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of feed variability on cesium removal with multiple actual waste samples from the Hanford site

Here, the Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. This lot of material was found to have superior performance in comparison to historic batches of CST. Ion exchange column and batch contact testing with supernate from Hanford tanks AP-105, AP-107 and AW-102 was performed to assess the impact of feed variability on system performance. These tests demonstrated that batch contact measurements provide a reasonable prediction of column capacities with some deviation in performance attributed to column dynamics. In addition, the variability in CST capacity for cesium in the various actual waste samples does not track with historical understanding of the competing cations, suggesting that tank waste samples contain other components that may significantly impact cesium loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of CO2 levels on nutrient content of lettuce and radish

Atmospheric carbon-dioxide enrichment is known to affect the yield of lettuce and radish grown in controlled environments, but little is known about CO2 enrichment effects on the chemical composition of lettuce and radish. These crops are useful model systems for a Controlled Ecological Life-Support System (CELSS), largely because of their relatively short production cycles. Lettuce (Lactuca sativa L.) cultivar 'Waldmann's Green' and radish (Raphanus sativus L.) cultivar 'Giant White Globe' were grown both in the field and in controlled environments, where hydroponic nutrient solution, light, and temperature were regulated, and where CO2 levels were controlled at 400, 1000, 5000, or 10,000 ppm. Plants were harvested at maturity, dried, and analyzed for proximate composition (protein, fat, ash, and carbohydrate), total nitrogen (N), nitrate N, free sugars, starch, total dietary fiber, and minerals. Total N, protein N, nonprotein N (NPN), and nitrate N generally increased for radish roots and lettuce leaves when grown under growth chamber conditions compared to field conditions. The nitrate-N level of lettuce leaves, as a percentage of total NPN, decreased with increasing levels of CO2 enrichment. The ash content of radish roots and of radish and lettuce leaves decreased with increasing levels of CO2 enrichment. The levels of certain minerals differed between field- and chamber-grown materials, including changes in the calcium (Ca) and phosphorus (P) contents of radish and lettuce leaves, resulting in reduced Ca/P ratio for chamber-grown materials. The free-sugar contents were similar between the field and chamber-grown lettuce leaves, but total dietary fiber content was much higher in the field-grown plant material. The starch content of growth-chamber lettuce increased with CO2 level.

NASA Discipline Life Support Systems↗

Considerations for a New Solution Reactor for Nuclear Criticality Safety Applications-a White Paper

This document presents considerations for a new solution reactor as noted in the United States (US) Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP) Five Year Plan. The solution reactor tasking is noted in collaboration with the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN). This document presents General Considerations (GC) and Specific Considerations (SC) that support the GCs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nano-Engineered Catalyst Supported on Ceramic Hollow Fibers for the Utilization of CO 2 in Dry Reforming to Produce Syngas

The objective of this project was to develop a novel catalytic reactor containing nano-engineered catalysts for the utilization of CO 2 (captured from coal-fired power plants and other CO 2 emitting sources) in dry methane reforming (DMR) (CO 2 + CH 4 → 2 H 2 + 2 CO) to produce synthesis gas (syngas). The technology aims to reduce CO2 emissions by developing beneficial uses for CO 2 from coal-fired power plants. It also offers an alternative to mitigate CO 2 emissions in areas where geologic storage may not be an optimal solution and/or utilization could significantly offset the costs of carbon capture and sequestration. The nano-engineered Ni-based catalyst was prepared by atomic layer deposition (ALD). The Ni particles were as small as ~2-4 nm. The nano-engineered catalyst showed CH 4 conversion >95%, H 2 /CO ratio in the range of 0.7-1.0, and CH 4 reforming rate as high as 2,500 L/h/gNi at 850 ºC and pressure of 15-25 psia. The Ni-based ALD catalyst also showed good stability in DMR reaction during a 200-h continuous operation at 850 °C. This is due to strong bonding between the nanoparticles and substrates since the Ni nanoparticles were chemically bonded to the substrate during the ALD process. The high thermal stability maintains the high dispersion of Ni nanoparticles, which can inhibit coke formation because their step edges are small enough to limit carbon nucleation and growth. Technoeconomic analysis (TEA) indicates the levelized cost of syngas (LCOS) is $172/ton with our technology, which is lower than the equivalent (molar) cost of hydrogen produced by steam methane reforming (SMR) or autothermal reforming (ATR). The major operating cost is natural gas feed and fuel, and the levelized cost is highly sensitive to the price of natural gas and relatively insensitive to the CAPEX. Revenues from syngas could have a significant impact on the net cost of electricity (COE), depending on the cost of natural gas and the selling price of syngas, estimated at $36 per MWh if the syngas were sold at $195 per ton. Following DOE NETL’s guidance, a lifecycle analysis (LCA) was conducted to compare with SMR. The functional unit for the basis of comparison was defined as 1kg carbon monoxide in the product stream. The global warming potential (GWP) of our process was found to be 40% lower than the state-of-the-art SMR process. The sensitivity analysis confirms the emissions are most sensitive to the natural gas fuel requirements to deliver heat to the process.

01 COAL, LIGNITE, AND PEAT↗

Grounding and fault protection of the SMUD PVI array

If large terrestrial photovoltaic (PV) power plants are to provide an economic source of generation, low-cost, reliable and easily maintainable systems must be developed. In addition, if the system is to be a central station powerplant owned and operated by an electric utility, the design must also be consistent with utility specifications and design standards. The particular solutions developed to address these issues, with regard to grounding and fault protection, for the first phase of the Sacramento Municipal Utility District's (SMUD) 100 mw(ac) PV powerplant are presented. This plant, known as PV1, is nominally rated at 1 mw(ac) and is scheduled to be in operation by the spring of 1984.

Rosen, D.↗

Elevating zero dimensional global scaling predictions to self-consistent theory-based simulations

In this work, we have developed an innovative workflow, Stability, Transport, Equilibrium, and Pedestal (STEP)-zero-dimensional (0D), within the OMFIT integrated modeling framework. Through systematic validation against the International Tokamak Physics Activity global H-mode confinement database, we demonstrated that STEP-0D, on average, predicts the energy confinement time with a mean relative error of less than 19%. Moreover, this workflow showed promising potential in predicting plasmas for proposed fusion reactors such as the affordable, robust, compact (ARC) reactor, the European demonstration power plant (EU-DEMO), and the China fusion engineering test reactor (CFETR) indicating moderate H-factors between 0.9 and 1.2. STEP-0D allows theory-based prediction of tokamak scenarios, beginning with 0D quantities. The workflow initiates with the PRO-create module, generating physically consistent plasma profiles and equilibrium using the same 0D quantities as the IPB98(y,2) confinement scaling. This sets the starting point for the STEP module, which further iterates between theory-based physics models of equilibrium, core transport, and pedestal to yield a self-consistent solution. Given these attributes, STEP-0D not only improves the accuracy of predicting plasma performance but also provides a path toward a novel fusion power plant design workflow. When integrated with engineering and costing models within an optimization, this new approach could eliminate the iterative reconciliation between plasma models of varying fidelity. This potential for a more efficient design process underpins STEP-0D's significant contribution to future fusion power plant development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

North Carolina Water Utility Builds Resilience with Distributed Energy Resources

As the frequency and duration of grid outages increase, backup power systems are becoming more important for ensuring that critical infrastructure continues to provide essential services. Most facilities rely on diesel generators, which may be ineffective during long outages owing to limited fuel supplies and high generator failure rates. Distributed energy resources such as solar, storage, and combined-heat-and-power systems, coupled with on-site biofuel production, offer an alternative source of on-site generation that can provide both cost savings and resilience (i.e., the ability to respond to catastrophic events with longer-term consequences). A mixed-integer linear program minimizes costs and maximizes resilience at a wastewater treatment plant in Wilmington, North Carolina. We find that the plant can reduce life-cycle energy costs by 3.1% through the installation of a hybrid combined-heat-and-power, photovoltaic, and storage system. When paired with existing diesel generators, this system can sustain full load for seven days while saving $664,000 over 25 years and reducing diesel fuel use by 48% compared with the diesel-only solution. This analysis informed a decision by the Cape Fear Public Utility Authority to allocate funds for the implementation of a combined-heat-and-power system at the wastewater treatment plant in fiscal year 2023. Finally, the benefits of deploying hybrid combined-heat-and-power technologies and the utilization of on-site biofuel production extend, on a national scale, to thousands of wastewater treatment facilities and other types of critical infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An optimization approach for cryogenic distillation-based protium removal systems in magnetic fusion energy fuel cycles

Tritium inventory reduction for fusion power plants is central to the successful adoption of fusion energy. The advent of direct internal recycling in deuterium-tritium fusion fuel cycle design has led to significant reduction in startup tritium inventory estimates for fusion power plants but requires an isotope rebalancing and protium removal (IRPR) system to ensure acceptable isotopic fuel composition. Cryogenic distillation is a potential solution for near-term deployment in an IRPR system due to its demonstrated performance in similar operating regimes. Using protium removal in the fuel cycle as the primary performance metric, this paper presents an optimization methodology for a single-column continuous cryogenic distillation-based IRPR system for a 500 MW fus magnetic fusion device. Distillation column optimization was performed using the CryOgenic Distillation For Isotopic Separation of Hydrogen (CODFISH) code developed at Savannah River National Laboratory. The distillation column design presented maximizes direct recycling of hydrogen isotopes from the fusion chamber exhaust to the fueling system while minimizing IRPR system steady-state tritium inventory. The optimized IRPR distillation column presented achieves direct recycling of 60 % of the hydrogen isotopes in the fusion chamber exhaust with an estimated steady-state system tritium inventory <30 g. In conclusion, the optimized IRPR distillation column operation was then used to estimate the design requirements for a detritation column to treat the IRPR system effluent stream.

CryOgenic distillation↗

Digitalization Guiding Principles and Method for Nuclear Industry Work Processes

The commercial U.S. light-water reactor fleet has been operating at historical efficiency, reliability, and safety over the last decade. Nuclear power has the highest capacity factor of any other power generation technology while also serving as the largest baseload source for carbon-free energy. Despite this remarkable achievement, continued operations for many plants are threatened due to fierce electricity market competition and rising operations and maintenance costs of which continued maintenance of obsolete analog equipment is a contributor. The digital age and associated technologies are where the future lies in process control, and nuclear has yet to take full advantage of the capabilities offered therein. The Light Water Reactor Sustainability Program (LWRS) at Idaho National Laboratory (INL), sponsored by the Department of Energy, has a mission to help the light-water reactor fleet manage its foundational capabilities to continue providing safe and reliable carbon-free power. LWRS helps support that mission by providing scientific, technology-based solutions for advanced concepts of operations with a more viable business model that will allow the fleet to continue to operate at peak levels through extended plant operation. The LWRS Digitalization Project at INL seeks to leverage digital technologies to synthesize and transform work processes. We provide a state-of-the-art analysis of digitalized work processes in nuclear power and investigate ways in which researchers at INL and the nuclear industry can work together to identify what data to access, how to access it, what to do with the data, and most importantly, how to use the insights for decision-making across all levels within the business. Borne from these considerations, we present four guiding principles for digitalization: develop a coherent digitalization plan, apply human factors engineering, establish data governance, and anticipate unintended consequences. Together, these principles form a method that plants can use to effectively to digitalize nuclear industry work processes. Our guiding principles are informed by multiple knowledge sources. First, we document activities from the Work Digitalization Initiative, which was conceived as a means for nuclear organizations to help define and standardize the industry’s approach to digitalizing work. Second, we detail primary research conducted with industry professionals regarding drivers and barriers to digitalization adoption. We present survey results that demonstrate what the industry hopes to get out of digitalization and the ways that INL can continue to support the industry’s digital transformation. Third, we present a digitalization use case with industry partners NextAxiom Technology and Xcel Energy. The project objective was to transform the current condition report work process from paper to digital, incorporating digitalized principles. We report the development of the application and lessons learned. The accomplishments achieved by this research and development serve to identify critical needs for plant guidance in support of digitalization implementation and contribute to the knowledge and strategies available for utilities considering or undertaking digitalization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗