Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Analysis of Tank 38H (HTF-38-16-26, 27) and Tank 43H (HTF-43-16-28, 29) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program and Corrosion Control Program. The total uranium in the Tank 38H samples ranged from 20.5 to 34.0 mg/L while the Tank 43H samples ranged from 47.6 to 50.6 mg/L. The U-235 percentage ranged from 0.62% to 0.64% over the four samples. The total uranium and percent U-235 results appear consistent with previous Tank 38H and Tank 43H uranium measurements. The Tank 38H plutonium results show a large difference between the surface and sub-surface sample concentrations and a somewhat higher concentration than previous sub-surface samples. The two Tank 43H samples show similar plutonium concentrations and are within the range of values measured on previous samples. The plutonium results may be biased high due to the presence of plutonium contamination in the blank samples from the cell sample preparations. The four samples analyzed show silicon concentrations ranging from 47.9 to 105 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development laboratories in Washington State. The U.S. Department of Energy (DOE) contracts to Battelle at Richland facilities on both the DOE Hanford Site and the Pacific Northwest National Laboratory (PNNL) Richland campus. These facilities have the potential for radionuclide air emissions. The PNNL contract with DOE also includes operations at the PNNL-Sequim campus in Sequim, where there is also the potential for radionuclide air emissions. This document is a periodic update that describes current PNNL facility emission units and sampling systems. The National Emission Standard for Hazardous Air Pollutants (NESHAP [40 Code of Federal Regulations 61, Subpart H]) requires an assessment of all emission units that have the potential for radionuclide air emissions. Emission units are registered with the State of Washington. Potential emissions from emission units are assessed annually by PNNL staff. Sampling, monitoring, and other regulatory compliance requirements are designated based on the potential to-emit dose criteria, a graded approach to facility-identified potential impact categories, and regulatory requirements. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled emission units, the building, exhaust unit, control technologies, and sample extraction details are provided. Additionally, applicable configuration drawings, figures, and photographs are included. For non-sampled emission units, emission estimation and radionuclide source details are provided. Site-wide permits for the lowest potential impact category are described. Deregistered/transitioned emission unit details are also provided as necessary for at least 5 years post-closure/transition. Currently, five emission units are sampled continuously for particulate radionuclides at PNNL managed facilities on the PNNL-Richland campus (3 of the 5) and on the Hanford Site (2 of the 5). Four of these units have sampling systems that comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1–2011 standard for sampling from stacks and ducts of nuclear facilities, and the fifth is grandfathered and compliant with the older ANSI N13.1–1969 standard. In addition, the PNNL-managed Hanford Site 325 Building EP 325-01-S stack is sampled continuously for emissions of tritium. No emissions sampling is required for the single licensed emission unit on the PNNL-Sequim campus.

54 ENVIRONMENTAL SCIENCES↗

STATISTICAL EVALUATION OF SMALL SCALE MIXING DEMONSTRATION SAMPLING AND BATCH TRANSFER PERFORMANCE - 12093

The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste Treatment and Immobilization Plant (WTP) presents a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS) has previously presented the results of mixing performance in two different sizes of small scale DSTs to support scale up estimates of full scale DST mixing performance. Currently, sufficient sampling of DSTs is one of the largest programmatic risks that could prevent timely delivery of high level waste to the WTP. WRPS has performed small scale mixing and sampling demonstrations to study the ability to sufficiently sample the tanks. The statistical evaluation of the demonstration results which lead to the conclusion that the two scales of small DST are behaving similarly and that full scale performance is predictable will be presented. This work is essential to reduce the risk of requiring a new dedicated feed sampling facility and will guide future optimization work to ensure the waste feed delivery mission will be accomplished successfully. This paper will focus on the analytical data collected from mixing, sampling, and batch transfer testing from the small scale mixing demonstration tanks and how those data are being interpreted to begin to understand the relationship between samples taken prior to transfer and samples from the subsequent batches transferred. An overview of the types of data collected and examples of typical raw data will be provided. The paper will then discuss the processing and manipulation of the data which is necessary to begin evaluating sampling and batch transfer performance. This discussion will also include the evaluation of the analytical measurement capability with regard to the simulant material used in the demonstration tests. The paper will conclude with a discussion of the analysis results illustrating the relationship between the pre-transfer samples and the batch transfers, which support the recommendation regarding the need for a dedicated feed sampling facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microfluidic-Based Sample Chips for Radioactive Solutions

Historical nuclear fuel cycle process sampling techniques required sample volumes ranging in the tens of milliliters. The radiation levels experienced by analytical personnel and equipment, in addition to the waste volumes generated from analysis of these samples, have been significant. These sample volumes also impacted accountability inventories of required analytes during process operations. To mitigate radiation dose and other issues associated with the historically larger sample volumes, a microcapillary sample chip was chosen for further investigation. The ability to obtain microliter volume samples coupled with a remote automated means of sample loading, tracking, and transporting to the analytical instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste volumes. Sample chip testing was completed to determine the accuracy, repeatability, and issues associated with the use of microfluidic sample chips used to supply µL sample volumes of lanthanide analytes dissolved in nitric acid for introduction to an analytical instrument for elemental analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molten Salt Sampling Techniques and Analytical Approaches

Recent global interest in pyroprocessing and molten salt reactors has brought salt sampling methods and techniques back to the forefront of nuclear safeguards concerns. Issues with uranium supplies have also encouraged various countries to pursue advanced nuclear fuel cycles. Tracking nuclear material in molten salt has proven to be a challenge and updating molten salt sampling will greatly help in this endeavor. Molten salt is problematic to sample due to salt stratification, lack of homogeneity, solids, and difficulty with hot cell adaptations. Various salt sampling techniques have been used since before the 1960s including surface, spoon/spatula, and bar solidification. Since then, new types of sampling techniques have been developed to improve sampling results. These include rod/dip, pipet, suction, filtered sampling along with devices such as the Valve Core Sampler and the Multi-Level Sampler. These different approaches are being analyzed and improved upon along with developing requirements for an improved salt sampling device. Work continues to develop salt samplers that are more robust, easier to segment, collect at a specific depth, can work with filters, and can collect fines. Sampling parameters are also being narrowed in terms of stirring, settling time, filtration, depth, etc. In the future, we hope to address deficiencies for process control and nuclear material accountancy control by determining the best way to collect samples that minimizes contaminants and is representative. A compilation of salt sampling approaches, analyses techniques, and an evaluation of findings will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hourglass Sampling of Participants in the Human Reliability Program (HRP) for Drug and Alcohol (D&A) Testing

Hourglass Sampling of Participants in the Human Reliability Program (HRP) for Alcohol and Drug Testing Ivan R. Thomas Idaho National Laboratory The random sampling with replacement of Human Reliability Program (HRP) participants for alcohol and drug testing can have the disadvantage that some participants are selected multiple times while others might not be chosen during an annual testing period. To alleviate this inefficiency, an “hourglass” sampling scheme has been developed at the Idaho National Laboratory for the random selection of HRP participants. With this scheme, all HRP participants are placed in a primary population at the beginning of the calendar year, and throughout the year, sequential random samples (generally of a fixed sample size) are drawn without replacement until the population is emptied. Thus, each participant is guaranteed to be tested at least once annually; but due to the random selection, the time of the initial test is unknown. After initial testing, the participants drawn from the primary population are transferred to a secondary population for potential retesting. Each time that the primary population is sampled, the secondary population is likewise sampled, but the sampling is with replacement. Thus, while the primary population decreases at a constant rate, the secondary population increases at the same rate through the accrual and retention of previously-tested participants, hence the hourglass concept. The replacement sampling of participants from the secondary population is through an increasing sample size (a fixed percentage of those currently in the population). Thus, once in the secondary population, each participant has a constant probability of being reselected, but the number of annual reselections is less than would be realized through traditional replacement sampling from a single population. Furthermore, the objective of maintaining suspense on the part of the HRP participant is retained, that is, all participants, whether or not initially picked from the primary population or reselected from the secondary population, always anticipate a future selection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis

Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparate height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High energy X-ray characterization of the microstructure of PuGa alloy samples at macroscopic depths and non-ambient conditions

High energy (95 keV) X-rays were utilized to characterize the microstructure of eight PuGa alloy samples at room temperature and during cooling to ∼10 K. The samples had different Ga content (nominally 0-3.4 at.%), age, and history. A ninth sample, similarly characterized with neutron diffraction, was included to extend the Ga range to 7 at.%. The samples span the range from single phase α (monoclinic) to δ (face-centered cubic) PuGa, as well as a two-phase α′/δ sample. The crystallographic textures, phase fractions, lattice parameters and dislocation densities of each sample were evaluated through distinct analysis techniques. The textures of the samples were modest. In each case, the dislocation densities were relatively high, comparable to cold worked metals and metals exposed to similar radiation dose. At room temperature, the lattice parameters determined in the predominantly single-phase samples were larger than expected based on the nominal Ga concentration. The observed lattice thermal expansions of the single-phase δ samples to 10 K are self-consistent across the samples and consistent with previous measurements reported in the literature. Significantly larger thermal lattice strain is observed in the δ phase of the two-phase material due to mechanical constraint from the α′ phase, which has a three times larger thermal expansion and is much harder than the δ phase. In conclusion, the results demonstrate the unique value of high-energy X-rays for relatively routine microstructural characterization of Pu alloy samples.

36 MATERIALS SCIENCE↗

Faulting processes in active faults - Evidences from TCDP and SAFOD drill core samples

The microstructures, mineralogy and chemistry of representative samples collected from the cores of the San Andreas Fault drill hole (SAFOD) and the Taiwan Chelungpu-Fault Drilling project (TCDP) have been studied using optical microscopy, TEM, SEM, XRD and XRF analyses. SAFOD samples provide a transect across undeformed host rock, the fault damage zone and currently active deforming zones of the San Andreas Fault. TCDP samples are retrieved from the principal slip zone (PSZ) and from the surrounding damage zone of the Chelungpu Fault. Substantial differences exist in the clay mineralogy of SAFOD and TCDP fault gouge samples. Amorphous material has been observed in SAFOD as well as TCDP samples. In line with previous publications, we propose that melt, observed in TCDP black gouge samples, was produced by seismic slip (melt origin) whereas amorphous material in SAFOD samples was formed by comminution of grains (crush origin) rather than by melting. Dauphiné twins in quartz grains of SAFOD and TCDP samples may indicate high seismic stress. The differences in the crystallographic preferred orientation of calcite between SAFOD and TCDP samples are significant. Microstructures resulting from dissolution–precipitation processes were observed in both faults but are more frequently found in SAFOD samples than in TCDP fault rocks. As already described for many other fault zones clay-gouge fabrics are quite weak in SAFOD and TCDP samples. Clay-clast aggregates (CCAs), proposed to indicate frictional heating and thermal pressurization, occur in material taken from the PSZ of the Chelungpu Fault, as well as within and outside of the SAFOD deforming zones, indicating that these microstructures were formed over a wide range of slip rates.

Janssen, C.↗

A numerical and experimental approach to compare the effect of sample thickness in small in-situ SEM and large ex-situ tensile testing in Alloy 709

ASTM standards for tensile tests define specific sample size requirements regardless of grain size of the material. However, sample size requirements for testing should be considered in conjunction with the number of grains within its reduced cross-sectional area. This is particularly important for in-situ Scanning Electron Microscope (SEM) tensile tests, as they have to be conducted on smaller samples. In this study, a comprehensive experimental and numerical evaluation of the effect of specimen thickness (and the resulting number of grains within the cross-section) were conducted using in-situ SEM tensile test (on submillimeter thick samples) and ex-situ tensile tests (on samples of 0.68–5.9 mm thickness) and the results are compared with FEM simulations outcome. All tests were conducted at room temperature and the results are correlated to the number of grains within the thickness of specimens. The tensile test results indicated that even though the 0.2% proof stress and the tensile strength do not vary for the current range of thicknesses (with number of grains in the cross-section varying from 13 to 118), a difference in necking mechanism exists. Post tensile strength, thinner samples undergo more shear failure and diagonal localized necking whereas thicker samples experience more diffuse necking indicated by decreased area of shear failure at the edges and increased area of dimpled tensile failure at the center of the sample. Further, FEM results complement the experimental findings by showing the formation of conjugated localized shear bands on the upper and lower surface in the 0.68 mm thick sample and shear bands combining to form singular shear bands in thicker samples. These results also confirm the validity of the in-situ SEM tensile tests conducted on thinner samples as long as the required minimum number of grains exist within the cross-section.

36 MATERIALS SCIENCE↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

Efficient Sampling of Complex Interdependent and Multiplex Networks

Efficient sampling of interdependent and multiplex infrastructure networks is critical for effectively applying failure and recovery algorithms in real-world settings, as well as to generate property-preserving reduced-order graph-based ensembles that address topological uncertainties. In this paper, we first explore the performance, i.e. the success in preserving graph properties, of graph sampling algorithms for interdependent and multiplex networks with synthetic and real-world graphs. We simulate sampling algorithms under different parameter settings. These settings include probabilistic graph generators, coupling patterns, and various performance metrics. Our results show that while Random Node and Random Walk sampling algorithms perform best for interdependent networks, Random Edge and Forest Fire sampling algorithms perform best for multiplex networks. Second, we propose and implement a novel similarity-based sampling algorithm for multiplex networks that samples only log(N) number of layers of an N-layer multiplex network while yielding computational savings with performance guarantees. Experimental results show that similarity sampling outperforms complete sampling of all layers while decreasing performance costs from a linear scale to a logarithmic one. Our results also indicate that similarity-based sampling outperforms complete sampling and random selection in nearly all scenarios when tested with real-world data.

Subasi, Omer↗

Producing a BOSS CMASS sample with DES imaging

We present a sample of galaxies with the Dark Energy Survey (DES) photometry that replicates the properties of the BOSS CMASS sample. The CMASS galaxy sample has been well characterized by the Sloan Digital Sky Survey (SDSS) collaboration and was used to obtain the most powerful redshift-space galaxy clustering measurements to date. A joint analysis of redshift-space distortions (such as those probed by CMASS from SDSS) and a galaxy-galaxy lensing measurement for an equivalent sample from DES can provide powerful cosmological constraints. Unfortunately, the DES and SDSS-BOSS footprints have only minimal overlap, primarily on the celestial equator near the SDSS Stripe 82 region. Using this overlap, we build a robust Bayesian model to select CMASS-like galaxies in the remainder of the DES footprint. The newly defined DES-CMASS (DMASS) sample consists of 117,293 effective galaxies covering $1,244 {\rm deg}^2$. Through various validation tests, we show that the DMASS sample selected by this model matches well with the BOSS CMASS sample, specifically in the South Galactic cap (SGC) region that includes Stripe 82. Combining measurements of the angular correlation function and the clustering-z distribution of DMASS, we constrain the difference in mean galaxy bias and mean redshift between the BOSS CMASS and DMASS samples to be $\Delta b = 0.010^{+0.045}_{-0.052}$ and $\Delta z = \left( 3.46^{+5.48}_{-5.55} \right) \times 10^{-3}$ for the SGC portion of CMASS, and $\Delta b = 0.044^{+0.044}_{-0.043} $ and $\Delta z= ( 3.51^{+4.93}_{-5.91}) \times 10^{-3}$ for the full CMASS sample. These values indicate that the mean bias of galaxies and mean redshift in the DMASS sample is consistent with both CMASS samples within $1\sigma$.

79 ASTRONOMY AND ASTROPHYSICS↗

Tuning the spin dynamics and magnetic phase transitions of the Cantor alloy via composition and sample processing protocols: A muon spin relaxation study

CrMnFeCoNi, also called the Cantor alloy, is a well-known high-entropy alloy whose magnetic properties have recently become a focus of attention. Here, we present a detailed muon spin relaxation study of the influence of chemical composition and sample processing protocols on the magnetic phase transitions and spin dynamics of several different Cantor alloy samples. Specific samples studied include a pristine equiatomic sample, samples with deficient and excess Mn content, and equiatomic samples magnetized in a field of 9 T or plastically deformed in pressures up to 0.5 GPa. The results confirm the sensitive dependence of the transition temperature on composition and demonstrate that post-synthesis pressure treatments cause the transition to become significantly less homogeneous throughout the sample volume. In addition, we observe critical spin dynamics in the vicinity of the transition in all samples, reminiscent of canonical spin glasses and magnetic materials with ideal continuous phase transitions. Application of an external magnetic field suppresses the critical dynamics in the Mn-deficient sample, while the equiatomic and Mn-rich samples show more robust critical dynamics. The spin-flip thermal activation energy in the paramagnetic phase increases with Mn content, ranging from 3.1⁢(3) × 10 -21 J for 0% Mn to 1.2⁢(2) × 10 -20 J for 30% Mn content. These results shed light on critical magnetic behavior in environments of extreme chemical disorder and demonstrate the tunability of spin dynamics in the Cantor alloy via chemical composition and sample processing.

36 MATERIALS SCIENCE↗

Composite Sampling of a Bacillus anthracis Surrogate with Cellulose Sponge Surface Samplers from a Nonporous Surface

A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm 2 (four separate 929 cm 2 areas), larger than the 645 cm 2 prescribed by the standard Centers for Disease Control (CDC) and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p = 0.261). Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p = 0.720) for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001). The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.

59 BASIC BIOLOGICAL SCIENCES↗

Analyses and Comparison of Bulk and Coil Surface Samples from the DWPF Slurry Mix Evaporator

Sludge samples from the DWPF Slurry Mix Evaporator (SME) heating coil frame and coil surface were characterized to identify differences that might help identify heat transfer fouling materials. The SME steam coils have seen increased fouling leading to lower boil-up rates. Samples of the sludge were taken from the coil frame somewhat distant from the coil (bulk tank material) and from the coil surface (coil surface sample). The results of the analysis indicate the composition of the two SME samples are very similar with the exception that the coil surface sample shows ~5-10X higher mercury concentration than the bulk tank sample. Elemental analyses and x-ray diffraction results did not indicate notable differences between the two samples. The ICP-MS and Cs-137 data indicate no significant differences in the radionuclide composition of the two SME samples. Semi-volatile organic analysis revealed numerous organic molecules, these likely result from antifoaming additives. The compositions of the two SME samples also match well with the analyzed composition of the SME batch with the exception of significantly higher silicon, lithium, and boron content in the batch sample indicating the coil samples are deficient in frit relative to the SME batch composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Variation in Uranium Isotopic Ratios 238 U/ 235 U and 234 U/ 238 U and 236 U/ 238 U in Water Samples Collected from Private Wells in the Española Basin, Santa Fe, New Mexico

This report presents uranium concentration and variation in uranium isotopic ratios 238 U/ 235 U and 234 U/ 238 U and 236 U/ 238 U in water samples collected from private wells in the Española basin in New Mexico. The document focuses specifically on analyzing variations in the uranium isotopic composition of the different water samples. The data presented in this report were obtained from water samples collected during the fall of 2012. A list of the different sampling locations as identified by their GPS coordinates is presented in Table 1 and represented on a map shown in Figure 1. Water temperature, conductivity, pH, and redox conditions (ORP) were also measured at the time of sampling and are also presented in Table 1. The pH of the samples ranged between 7.10 and 8.49, the temperature between 11.30 and 16.58 ˚C, and the ORP between -182 and 202 mV. The conductivity of the samples was between 454 µS·cm -1 and 1066 µS·cm -1 . The concentration of uranium in the samples varied widely and ranged between 11.5 and 776 µg/L. Uranium isotopic ratios conducted by Thermal Ionization Mass Spectrometry (TIMS) showed natural 238 U/ 235 U within analytical uncertainty. The water samples showed some variations in the isotopic ratios of 234 U/ 238 U, varying from atom ratios of 54.9×10 -6 to 226×10 -6 (activity ratios of 1.00 to 4.11), and indicating enrichment of 234 U in many of the water samples. These isotopic ratios are within the range observed in natural water. Such enrichments in 234 U in natural waters are common and typically attributed to natural processes. There was no detectable 236 U in any of the samples analyzed.

07 ISOTOPE AND RADIATION SOURCES↗

Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites

This plan incorporates U.S. Department of Energy (DOE) Office of Legacy Management (LM) standard operating procedures (SOPs) into environmental monitoring activities and will be implemented at all sites managed by LM. This document provides detailed procedures for the field sampling teams so that samples are collected in a consistent and technically defensible manner. Site-specific plans (e.g., long-term surveillance and maintenance plans, environmental monitoring plans) document background information and establish the basis for sampling and monitoring activities. Information will be included in site-specific tabbed sections to this plan, which identify sample locations, sample frequencies, types of samples, field measurements, and associated analytes for each site. Additionally, within each tabbed section, program directives will be included, when developed, to establish additional site-specific requirements to modify or clarify requirements in this plan as they apply to the corresponding site. A flowchart detailing project tasks required to accomplish routine sampling is displayed in Figure 1. LM environmental procedures are contained in the Environmental Procedures Catalog (LMS/PRO/S04325), which incorporates American Society for Testing and Materials (ASTM), DOE, and U.S. Environmental Protection Agency (EPA) guidance. Specific procedures used for groundwater and surface water monitoring are included in Appendix A. If other environmental media are monitored, SOPs used for air, soil/sediment, and biota monitoring can be found in the site-specific tabbed sections in Appendix D or in site-specific documents. The procedures in the Environmental Procedures Catalog are intended as general guidance and require additional detail from planning documents in order to be complete; the following sections fulfill that function and specify additional procedural requirements to form SOPs. Routine revision of this Sampling and Analysis Plan will be conducted annually at the beginning of each fiscal year when attachments in Appendix D, including program directives and sampling location/analytical tables, will be reviewed by project personnel and updated. The sampling location/analytical tables in Appendix D, however, may have interim updates according to project direction that are not reflected in this plan. Deviations from location/analytical tables in Appendix D prior to sampling will be documented in project correspondence (e.g., startup letters). If significant changes to other aspects of this plan are required before the annual update, then the plan will be revised as needed.

54 ENVIRONMENTAL SCIENCES↗