Search NASASearch

SEARCH · Search NASA

Results for “single atom sites”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

580 records · Page 26

Draft ASME Code Case to qualify L-PBF 316H material for Section III, Division 5 applications

This report documents the AMMT program’s development and submission of a draft ASME Code Case to qualify Laser Powder Bed Fusion (L PBF) Type 316H stainless steel for Section III, Divi-sion 5 Class A and SM high temperature nuclear applications. It summarizes the technical basis, the comprehensive high temperature mechanical test database assembled between 2023–2026, and the proposed code language and qualification framework submitted to ASME. The work was co-ordinated across multiple national laboratories and leverages prior ASME efforts to integrate additive manufacturing into the Boiler & Pressure Vessel Code. The body of the report describes the experimental database and analysis supporting the Code Case: tensile, creep, fatigue, creep fatigue, and thermal aging tests collected from multiple additive manufacturing sites, machine types, and powder lots, with material processed by a solution anneal heat treatment. The dataset — including both full size and subsized specimens and tests oriented parallel and perpendicular to build direction — shows limited tensile anisotropy, tensile properties comparable to wrought 316H, creep strength within the scatter of wrought material, but markedly reduced creep ductility above about 650 °C associated with rapid σ phase formation in L PBF microstructures. The draft Code Case itself prescribes a staged qualification model (manufacturing process qualification, component qualification, and per build witness testing), treats L PBF components as equivalent to Type 316 weld metal for design and inspection, and requires mechanical, chemical, and metallographic controls tied to ASTM/ISO 52946. Key acceptance criteria include tensile tests within a 90% prediction interval of the AMMT dataset, a creep fatigue screening test adapted from ASME Section III, Division 5, Subsection HB, HBB 2800 but with the cycle acceptance reduced to 100 for L PBF material, and double volumetric inspection of production components. The report concludes that the present data support treating L PBF 316H as analogous to conventional fusion weld metal for Division 5 design and inspection, while highlighting important caveats: the σ phase driven loss of creep ductility above ~650 °C, preliminary indications of enhanced creep fatigue sensitivity in some lots, and remaining gaps in long term aging and additional cyclic testing. Recommended next actions include completing outstanding cyclic and long duration creep/aging tests on the solution annealed condition, supporting inclusion of the 316H chemistry and heat treatment in ASTM/ISO 52946, and continuing engagement with ASME and NRC during balloting and review to enable industry adoption.

Messner, Mark C. (ORCID:0000000200404385)

Magnetism and magnetoelastic effect in the two-dimensional van der Waals multiferroic CuCrP 2 ⁢S 6

Here, we report a magnetic and neutron diffraction study on the ground state magnetism and field evolution of single-crystal van der Waals multiferroic CuCrP 2 ⁢S 6 . The ordered moments align along the 𝑏 axis in the "𝐴-type" antiferromagnetic configuration with a spin-flop transition along the same direction. Field application along 𝑎 introduces a smooth transition to a fully polarized ferromagnetic state via in-plane spin rotation. These findings resolve the ambiguity of the ground state magnetization direction in CuCrP 2 ⁢S 6 and uncover its field responses, providing a firm basis for future magnetoelectric study. A magnetoelastic coupling effect connecting the interlayer spacing and the magnetic order was further revealed, highlighting the out-of-plane strain as an effective control knob for tuning magnetism both in this system and in related van der Waals magnets.

Guo, Jiasen [Oak Ridge National Laboratory (ORNL),

A quantitative imaging framework for lithium morphology: Linking deposition uniformity to cycle stability in lithium metal batteries

Characterizing the morphology of lithium (Li) is crucial for developing long-lasting lithium metal batteries. It is well established that more uniform Li deposition correlates with better cell performance. Li morphology is often characterized through qualitative analysis of scanning electron microscopy (SEM) images; however, there are no widely accepted metrics to quantitatively describe deposition uniformity. Here, we propose a framework to quantify uniformity through SEM image analysis via the index of dispersion (ID) metric, which is defined and presented in the context of Li metal batteries. We also explore experimental impacts of sampling protocols onIDmeasurements. Our results demonstrate that theIDmetric is highly sensitive to variations in deposition uniformity, including the coexistence and uniformity of multiple morphologies, uniformity within a single morphology, and particle size distribution uniformity. Furthermore, it is demonstrated that uniformity, as measured by theID, can be related to the average potential of Li||Li symmetric cells over cycling. Higher capacity cycling leads to more pronounced changes in bothIDand average cell potential. Local minima/maxima are found consistently in bothIDand average cell potential immediately before cells short-circuit, which we suggest may indicate a collapse of the microstructure prior to failure. We put forward this framework as a more robust approach to quantify Li deposition uniformity, advancing the development of Li metal batteries that are safer and longer lasting.

Science & Technology - Other Topics

Probing the role of local tunnel variations in early-stage lithiation of α-MnO₂ nanowires via in situ TEM

Understanding lithium-ion transport in tunnel-structured manganese oxides is essential for designing high-performance lithium-ion battery electrode materials. Here, we elucidate the early-stage lithiation mechanism of potassium-stabilized α-MnO 2 nanowires using in situ transmission electron microscopy (TEM) coupled with electron energy-loss spectroscopy (EELS), high-resolution TEM (HRTEM), and geometric phase analysis (GPA). Real-time TEM imaging reveals clear volume expansion at the reaction front, while EELS analysis uncovers lithium-ion diffusion far beyond this region, where no visible expansion is observed, indicating fast, defect-assisted transport. GPA and HRTEM analyses show that localized tensile and compressive strain fields, originating from pre-existing local tunnel structural variations, persist after lithiation. The tensile-strained regions enable lithium-ion insertion with minimal lattice distortion, offering additional free volume that facilitates rapid lithium-ion accommodation ahead of the structural transformation. Our results demonstrate a local tunnel variation-mediated fast diffusion pathway that precedes bulk reaction, underscoring the critical role of local strain in enabling early-stage lithium transport. Given the structural versatility of MnO 2 and its ability to accommodate diverse atomic arrangements beyond the well-known tunnel phases (β-, γ-, δ-, λ-, R-phases), our findings highlight the importance of understanding and engineering local structural environments. This work provides fundamental insights into the interplay between defects, strain, and ion dynamics, and presents defect engineering as a promising approach to enhance both rate performance and structural stability in manganese-based cathodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Detecting thermodynamic phase transition via explainable machine learning of photoemission spectroscopy

Identifying thermodynamic signatures of electronic phases, such as superconductivity, is challenging in low-dimensional materials due to strong fluctuations and low probing volume. Spectroscopic methods are often used to identify new bulk phases, but their main measurable quantity—electronic energy gaps—is no longer an effective order parameter in low-dimensional and fluctuating systems. Combining angle-resolved photoemission with a domain-adversarial neural network, we report a data-driven method to identify thermodynamic phase transitions solely based on single-particle spectra. We demonstrate 97.6% accuracy in cuprate superconductor Bi 2 Sr 2 CaCu 2 O 8+δ with strong superconducting fluctuations. This model notably compensates for the scarcity of experimental data by leveraging virtually inexhaustible simulated data. Further, its explainability reveals the crucial role of in-gap spectral weight in detecting phase fluctuations and thermodynamic transitions. Our work pinpoints the spectroscopic signatures of fluctuating orders and enables using spectroscopy for machine-learning-assisted material discovery for low-dimensional and strong coupling systems.

2D materials

Stationary Testing of a Pulse Tube Cryocooler Designed to Rotate at 6800 RPM with the Superconducting Rotor of an Electric Machine

Electrified aircraft are being developed to increase the efficiency and reduce the cost of operating subsonic transport aircraft. Achieving a substantial impact necessitates focusing on single- and twin-aisle aircraft which use propulsion systems with >20 MW ratings. For these aircraft, multi-MW superconducting electric machines are being developed due to their high specific power and high efficiency. Most of these electric machines employ superconductors on their rotor, thereby requiring cryogenic cooling of the rotating system. An attractive solution is to conductively cool the rotor using a cryocooler that rotates with the rotor. NASA has been developing a 50 K pulse tube cryocooler for its High Efficiency Megawatt Motor (HEMM) that can operate while rotating at up to 6,800 rpm. The first non-rotating tests of the fully assembled HEMM cryocooler have been completed, and initial testing has yielded a no-load temperature of 112 K. A small helium leak into the vacuum system has been identified as the major bottleneck to performance, and based on measurements with the motor turned off there is an observed vacuum-side heat leak of approximately 30 W at 115 K. Immediate next steps for testing are to locate and mitigate the apparent helium leaks into the vacuum chamber. Thus far, compressor performance and the apparent heat lift after correcting for the heat leak are on par with expectations.

Electrified Aircraft Propulsion

A Kinetic Model of the Long-Term Corrosion of Glass-Ceramic Materials

Multiphase waste forms show promise for increased waste loading and for the ability to dispose of contaminated solid and particulate waste through direct densification. However, achieving predictive capability for long-term durability of multiphase waste forms, and thus assessing their possible deployment, requires expanding the current, limited knowledge base. Here, we describe the development of a corrosion model of a two-phase waste form consisting of crystals of known volume fraction embedded in a glass matrix. This model accounts for the dissolution of both the crystalline and glass phases as well as the hydration of the glass phase through an ion exchange reaction. Because of the large difference in solubility between the two phases, the reactive surface of the crystalline phase is a function of the extent of dissolution of the glass phase in this model. Model parameterization was performed using corrosion data, such as from single-pass flow-through tests, for the individual phases. The parameterized corrosion model was evaluated against static dissolution test data for a glass-ceramic multiphase waste form. This evaluation demonstrated the model’s ability to reproduce the time-dependent release of key tracers of glass and crystalline phase dissolution. Hence, the development of a kinetic model provides a pathway for long-term durability predictions and thus the use of multiphase waste forms in nuclear cleanup missions.

Kerisit, Sebastien N.

Synthetic Tuning of Exciton–Phonon Coupling in Janus WS 2(1-x) Se 2x Monolayers Revealed by Resonant Raman Excitation Spectroscopy for Optoelectronic Applications

Janus monolayers, such as WSSe, have broken out-of-plane symmetry and an intrinsic dipole moment, impacting exciton transport, lifetime, and phonon interactions while imbuing piezoelectric, photocatalytic, and Rashba spin-splitting properties to transition metal dichalcogenides (TMDs). The new properties of this atomically thin material can be used for optoelectronic device applications. As TMDs are converted into Janus monolayers, e.g., top selenization of WS2 to WSSe, the bandgap and structure smoothly evolve, impacting not only the formation of excitons but also their complex interactions with different phonon modes. Resonant Raman excitation profiles (REPs) are uniquely well-suited to reveal both excitonic transitions and exciton–phonon coupling. Here, the resonant REPs of $A^{'}_{1}$ WS 2 and A 1 WSSe modes are measured to understand the strength of their coupling with the A, B, and C excitonic bands of a WS2 monolayer throughout its stepwise transformation into Janus WSSe by pulsed laser deposition (PLD) of energetic selenium species. In situ Raman spectroscopy during deposition is used to controllably prepare stable intermediate Janus structures, WS 2(1-x) Se 2x (0 ≤ x ≤ 0.5), for ex situ measurement of their resonant REPs. As x increases, REPs reveal not only pronounced excitonic bands that gradually shift toward lower photon energies but also strong, mode-selective exciton–phonon coupling. First-principles resonant Raman simulations independently predict this spectral behavior and are shown capable of matching the spectrally broadened, experimentally observed REP profiles in this model system, indicating their strong predictive capability for future experiments. The combination of controlled synthesis, REP characterization, and predictive theory employed here demonstrates a powerful pathway to understand and ultimately tune exciton–phonon interactions for future quantum optical devices.

Janus monolayers

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A parametric study of slow dynamic nonlinear elasticity with comparisons to models

Several phenomenological models that aspire to quantitative description of anomalous nonlinear mesoscopic elasticity are reviewed and compared with laboratory measurements. This class of nonlinearity, best known perhaps for slow dynamics and aging, is seen widely in imperfectly consolidated granular solids but is not well understood. Typical slow dynamic tests show that a modest conditioning oscillatory "pump" strain depresses material stiffness, which then recovers like the logarithm of time after conditioning ceases. Several phenomenological models based on physical arguments have been proposed that predict the material stiffness response to arbitrary pump strain histories during conditioning and recovery. Approximate closed form and numerical solutions to the models are presented that predict the quantitative influence of three key pump parameters: the pump's strain amplitude, the pump's strain rate, and the pump’s duration. Laboratory measurements on Berea sandstone, concrete and a confined single aluminum bead find that slow dynamic responses are linear in pump strain and independent of pump frequency. Measurements also show that, after pump-off, stiffness recovers over times far longer than the pump duration. These observations and others are compared to model predictions. One of the considered models, based on a picture of fast brittle damage and slow healing, successfully matches all these behaviors.

36 MATERIALS SCIENCE

Impact of Technology and Mission Variations on Aircraft Designed for Advanced Air Mobiity

NASA is conducting investigations in Advanced Air Mobility (AAM) aircraft and operations, including the development of Urban Air Mobility (UAM) aircraft designs that can be used to focus and guide research activities in support of AAM. This report is an investigation of the impact of technology and mission variations on several of the NASA AAM concept aircraft: quadrotor, quiet single main rotor, side-by-side, and tiltrotor configurations, with turboshaft and electric propulsion variants for each. First, the mission and aircraft models of the baseline designs were reassessed and updated, including rotor geometry optimization, update of the rotor performance models, and disk loading optimization. For these eight designs, technology and mission excursions were performed. Relative to the calibration cases that can be considered examples of good design practice, the impact of the weight technology factors is significant. For the electric aircraft, there is a very large impact of battery specific energy (Wh/kg), and correspondingly a very large impact of mission range. The vision of Advanced Air Mobility is driven by missions that will enable new transportation capabilities. Hence it is appropriate to compare Concept Vehicles of different lift and propulsive architectures, all designed to accomplish the same UAM mission. It is also useful however to consider specific missions that can take advantage of the strengths of individual aircraft configurations. So alternate designs were also developed for the concept vehicles: for turboshaft aircraft, longer unrefueled range, including faster cruise speed for the tiltrotor; for electric aircraft, shorter range and more realistic battery weight.

Technology

Emergent surface resonance from charge density wave symmetry breaking in TiSe 2

Surface confined electronic states provide a fertile ground for discovering emergent phenomena that have no counterpart in the bulk, offering new routes to manipulate correlations, symmetry breaking, and dimensionality at the atomic scale. Here, in this study, we show that charge density wave (CDW) symmetry breaking can yield surface states in 1⁢T−TiSe 2 . Micro–angle-resolved photoemission spectroscopy (µ-ARPES) resolves a sharp, two-dimensional surface resonant state (SRS) that emerges within the CDW reconstructed low energy spectrum. The SRS exhibits notable temperature dependence and its spectral weight collapses around ∼ 160 K, while CDW transition temperature 𝑇 CDW is commonly reported as ≈ 202 K. Slab DFT + 𝑈 calculations reproduce a surface localized resonance when CDW folding brings valence and conduction states into near degeneracy, suggesting a correlation tuned, surface selective origin. These results point to a form of correlation-tuned surface resonance in a layered CDW compound and suggest a framework for engineering low-dimensional quantum states in van der Waals materials via symmetry breaking and electronic structure tuning.

36 MATERIALS SCIENCE

Multiscale aperture synthesis imager

Synthetic aperture imaging has enabled breakthrough observations from radar to astronomy. However, optical implementation remains challenging due to stringent wavefield synchronization requirements among multiple receivers. Here we present the multiscale aperture synthesis imager (MASI), which utilizes parallelism to break complex optical challenges into tractable sub-problems. MASI employs a distributed array of coded sensors that operate independently yet coherently to surpass the diffraction limit of single receiver. It combines the propagated wavefields from individual sensors through a computational phase synchronization scheme, eliminating the need for overlapping measurement regions to establish phase coherence. Light diffraction in MASI naturally expands the imaging field, generating phase-contrast visualizations that are substantially larger than sensor dimensions. Without using lenses, MASI resolves sub-micron features at ultralong working distances and reconstructs 3D shapes over centimeter-scale fields. MASI transforms the intractable optical synchronization problem into a computational one, enabling practical deployment of scalable synthetic aperture systems at optical wavelengths.

electrical and electronic engineering

Stabilization Of The CN 3 5− Anion In Recoverable High‐pressure Ln 3 O 2 (CN 3 ) (Ln=La, Eu, Gd, Tb, Ho, Yb) Oxoguanidinates

Abstract A series of isostructural Ln 3 O 2 (CN 3 ) (Ln=La, Eu, Gd, Tb, Ho, Yb) oxoguanidinates was synthesized under high‐pressure (25–54 GPa) high‐temperature (2000–3000 K) conditions in laser‐heated diamond anvil cells. The crystal structure of this novel class of compounds was determined via synchrotron single‐crystal X‐ray diffraction (SCXRD) as well as corroborated by X‐ray absorption near edge structure (XANES) measurements and density functional theory (DFT) calculations. The Ln 3 O 2 (CN 3 ) solids are composed of the hitherto unknown CN 3 5− guanidinate anion—deprotonated guanidine. Changes in unit cell volumes and compressibility of Ln 3 O 2 (CN 3 ) (Ln=La, Eu, Gd, Tb, Ho, Yb) compounds are found to be dictated by the lanthanide contraction phenomenon. Decompression experiments show that Ln 3 O 2 (CN 3 ) compounds are recoverable to ambient conditions. The stabilization of the CN 3 5− guanidinate anion at ambient conditions provides new opportunities in inorganic and organic synthetic chemistry.

Chemistry

Airports as Energy Nodes Activity Summary

Advanced aircraft concepts that use non-traditional aviation energy storage methods such as batteries or cryogenic hydrogen are in development and expected to enter regular service at airports worldwide within the next decade. The energy needs for these aircraft may quickly overwhelm the existing energy infrastructure at airports, particularly at smaller and more remote facilities. Without energy upgrades, these airports will not be able to host these advanced vehicles, but without the advanced vehicle traffic, these airports will not have the rationale or funding to build up their energy infrastructure. The Airports as Energy Nodes (ÆNodes) activity, a collaboration between the National Aeronautics and Space Administration (NASA) and the National Renewable Energy Laboratory (NREL), was executed to understand and model the energy needs that advanced aircraft concepts may levy on these smaller airports, determine cost-effective approaches to enhance the airport energy infrastructure, and demonstrate the enhanced resilience of these energy infrastructure upgrades to the airport and surrounding community via “digital twin” simulation at relevant energy and dynamic time scales. The ÆNodes team also investigated future reference aircraft designs and materials to enable cryogenic hydrogen storage for aircraft. The ÆNodes team conducted analysis at two U.S. airport partner sites — Winchester Regional Airport in Winchester, Virginia, and Tweed/New Haven Airport in New Haven, Connecticut. The goal of this partnership was to develop data and reference infrastructure designs that could accommodate advanced aircraft in the future at these airports while also enhancing the resiliency of the energy supply to the surrounding airport community, which could be used to capture funding to enable the infrastructure upgrades. Over the course of the study, a method was developed to estimate air traffic requiring advanced energy services over the course of a year using a mix of historical data and companion studies on advanced aircraft transportation networks. The study has concluded at NASA but continues at NREL, who will develop a final report discussing the energy infrastructure upgrades and digital twin results. Preliminary results indicate that unrestricted adoption of advanced battery-electric aircraft may double traffic at these airports and increase peak daily power usage by an order of magnitude, while increase electricity energy needs by a factor of two to four. The infrastructure upgrades necessary to accommodate these increased energy needs could be used to provide enhanced energy services to the airport community to offset the cost and increase the utility of the upgrades, which will be described in the NREL final report.

Airports

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft

Nuclear Safety [Vol. 16, No. 1, January-February 1975]

Nuclear Safety covers significant developments in the field of nuclear safety. The scope is limited to topics relevant to the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, safety considerations in regard to the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 1 AEC Working Paper on Population Density Around Nuclear Power-Plant Sites Adapted by J. Ft. Buchanan, 8 Water-Reactor Safety-Research Information Meeting by Wm. B. Cottrell, D. O. Hobson, and G. D. Whitman; ACCIDENT ANALYSIS: 29 Burnout in Boiling Heat Transfer. Part I: Pool-Boiling Systems by A. E. Bergles; PLANT SAFETY FEATURES: 43 Radionuclide Behavior During Normal Operation of Liquid-Metal-Cooled Fast Breeder Reactors. Part 1: Production by C. A. Erdman and A. B. Reynolds; CONSEQUENCES OF EFFLUENT RELEASE: 60 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 1: AEC-Owned Facilities by M. B. Biles and F. E. Coffman, 71 The Control, Monitoring, and Reporting of Radioactivity in Effluents. Part 2: AEC-Licensed Facilities by L. B. Higginbotham and J. T. Collins; OPERATING EXPERIENCES: 76 Incident at the Lucens Reactor by J. M. Miller, 79 IAEA Symposium on Experience from Operating and Fueling of Nuclear Power Reactors by William A. Pryor, 87 Recent Occurrences at Nuclear Reactors and Their Causes Compiled by William R. Casto, 98 Summary of Operating U. S. Power Reactors as of Nov. 1. 1974, 101 Selected Safety-Related Occurrences Reported in September and October 1974 Compiled by William R. Casto; CURRENT EVENTS: 104 General Administrative Activities Compiled by Wm. B. Cottrell, 110 Action on Power-Reactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 119 Action on Nonreactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 121 Proposed Rule Changes as of Oct. 31, 1974; MISCELLANY: 97 ASTM—Euratom Symposium on Radiation Dosimetry: Developments and Standardization (Announcement), 118 Workshops on In-Pile Filter Testing (Announcement), 119 IAEA Symposium on Radiological Impacts from Releases from Nuclear Facilities into Aquatic Environments (Announcement).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Eddy Covariance Theory: A Review

Eddy covariance (EC), the gold standard for measuring ecosystem scale gas and heat exchanges, has transformed our understanding of the breathing of the biosphere, and thus global change biology. Despite numerous methodological improvements and insights gained from the technique, the community faces persistent challenges that have been present since the first EC measurements. Here, we review the theoretical developments underpinning EC. We present theoretical developments in four important areas that have relevance to EC measurements of the net ecosystem exchanges (NEE) of gases and heat from a single tower: (i) measuring the total vertical flux density, (ii) flux attenuation, (iii) coordinate rotations, and (iv) energy balance closure. Persistent problems with EC measurements, such as the inability to close the energy budget, led us to identify two priorities for revisiting the theory underlying: (i) sensible heat flux calculations, and (ii) constraining the mean vertical wind velocity. We present a framework for improved calculation of sensible heat flux derived from first principles of fluid mechanics and thermodynamics that considers coupled heat and mass transfer so that conservation of both is obeyed. These refinements are motivated by the need for unbiased measurements of energy and mass transfer between the land surface and atmosphere for ecosystem research and to validate satellite observations and land surface models.

ecosystem fluxes