Search NASA⌕ Search

SEARCH · Search NASA

Results for “Arm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Tethered Balloon Observations of Vertically Resolved Aerosol Size Distributions during the U.S. DOE ARM CoURAGE and BNF Campaigns

This dataset contains vertically resolved aerosol particle number size distributions measured using a miniature Scanning Electrical Mobility Spectrometer (mSEMS) deployed aboard the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Tethered Balloon System (TBS) during the 2025 Coast-Urban-Rural Atmospheric Gradient Experiment (CoURAGE) and Bankhead National Forest (BNF) field campaigns. The mSEMS measured aerosol size distributions over approximately 10–300 nm during repeated TBS vertical profiles through the atmospheric boundary layer. The dataset provides measurements of particle number size distributions as a function of particle diameter, altitude, and time and supports investigation of aerosol vertical structure, elevated ultrafine and Aitken-mode particle layers, boundary-layer evolution, and residual-layer processes.

ARM↗

Nonlinear Contact Control for Space Station Dexterous Arms

In October 1996, a research and development task was initiated at JPL to develop and demonstrate nolinear contact control schemes for the dexterous robitc arms planned for the space station. This paper reports on the progress made to-date in this task.

Dexterous Arms↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station, the Crew and Thermal Systems Division at NASA JSC was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms in a simulated space environment versus testing with a full suit. The Dual Glove Box (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 10^-5 Torr with roughing and cryogenic pumps, and a wide range of shroud temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater plates. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through the development of 2 temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA) suits↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

spacesuit arms↗

Active Neutron Interrogation as a Method for Verification of the Absence of Special Nuclear Material in Arms Control Dismantlement

The next step in arms control reductions will deal with both strategic and non-strategic weapons, presenting new and hard challenges for verification. One verification approach that might be used in support of these reductions is the concept of deferred verification, which forgoes inspections at sensitive nuclear sites and relies on an inspection regime having access to the open segment of a State's nuclear sector, in "monitored transfer zones." A component of this approach is the anticipated need for an instrument suite capable of detecting well-shielded highly-enriched uranium or plutonium where it isn't supposed to be. This specific need was recently identified by the United Nations Institute for Disarmament Research in an enabling operating concept they call "contain and dispose." At the foundation of this approach is the idea that items declared as "not nuclear" are, by definition, not treaty limited and are thus "fair-game" for inspection and questioning. Active Neutron Interrogation (ANI), using beta-delayed neutron emissions as the signature for special nuclear material (SNM) detection, is a promising method to address this challenge. The method is quick, has high sensitivity and high specificity for detecting shielded SNM, is robust against changing background radiation environments, is robust against the presence of unknown shielding, and avoids the use of gamma-ray spectrometry which may introduce complications due to the potential release of sensitive information. This paper will present recent research activities exploring technical aspects of using ANI as a FAIRGAME verification method and discuss future prospects and research needs

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

CROWBAR: Natively Fuzzing Trusted Applications Using ARM CoreSight

Abstract Trusted execution environments (TEE) are deployed on many platforms to provide both confidentiality and integrity, and their extensive use offers a secure environment for privacy-sensitive operations. Despite TEE prevalence in the smartphone and tablet market, vulnerability research into TEE security is relatively rare. This is, in part, due to the strong isolation guarantees provided by its implementation. In this paper, we propose a hardware assisted fuzzing framework, CROWBAR, that bypasses TEE isolation to natively evaluate trusted applications (TAs) on mobile devices by leveraging ARM CoreSight components. CROWBAR performs feedback-driven fuzzing on commercial, closed source TAs while running in a TEE protected environment. We implement CROWBAR on 2 prototype commercial-off-the-shelf (COTS) smartphones and one development board, finding 3 unique crashes in 5 closed source TAs that are previously unreported in the TrustZone fuzzing literature.

Shan, Haoqi↗

Synthesis of poly(3,4-ethylenedioxythuophene) derivatives using three-armed conjugated cross-linker and its thermoelectric properties

Conducting polymer based thermoelectric systems are very effective at harvesting electricity from waste heat with low-temperature gradients relative to environmental temperature. However, although various studies concerning the doping effect exist, there are insufficient reports on the effect of the change in polymer chain structure on the thermoelectric properties. Here we demonstrate different poly(3,4-ethylenedioxythiophene) (PEDOT)-derivative chain structures (such as linear, two-dimensional, co-polymer), by varying the amount of three-armed conjugated cross-linker (1,3,5-tri(2-thienyl)-benzene (TTB)). Further, at a small amount of TTB addition (until 0.5 mM), the electrochemical charge transport of the PEDOT films increased without shift of the UV–Vis absorbing property. However, from higher than 0.5 mM TTB, electrochemical charge transport decreased with blue shift of the UV–Vis absorbing curve. Moreover, the power factor of the PEDOT-derivative films without TTB to a small amount of TTB (0.5 mM) was improved from (27.03 to 49.43) µWm -1 K -2 , and at higher than 0.5 mM TTB concentration, was diminished, respectively, because a small amount of TTB enhanced the π–π interaction of the polymer chains without disrupting the conjugation, while excess TTB molecules blocked conjugation of the polymer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Secure boot, trusted boot and remote attestation for ARM TrustZone-based IoT Nodes

With the extensive application of IoT techniques, IoT devices have become ubiquitous in daily lives. Meanwhile, attacks against IoT devices have emerged to compromise IoT devices by tampering with system pre-installed programs or injecting new malware. To mitigate these attacks, integrity enforcement of IoT systems has been proposed. The integrity of an IoT device system includes load-time integrity and runtime integrity. In this paper, we design an IoT system based on ARM TrustZone to enforce the system integrity. First, we establish the root of trust and propose a hybrid booting approach consisting of both secure boot and trusted boot to enforce the system load-time integrity. Second, we investigate a paging-based process integrity measurement method to measure the NW processes and conduct remote attestation based on the measurement results ensuring the NW runtime process integrity. We implement an IoT prototype system on a NXP i.MX6Q SABRE SD development board to assess its feasibility. Finally, real-world experiment results demonstrate that our prototype introduces negligible performance overhead to the original system.

97 MATHEMATICS AND COMPUTING↗