Search NASA⌕ Search

SEARCH · Search NASA

Results for “Digital Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Be like Oppenheimer: Donate your weapons information for the next generation of LANL researchers

You can follow the Lab’s first physicists, J. Robert Oppenheimer, Richard Feynman, Hans Bethe, and so many others through the years, plus know your information is helping future researchers — just like our first scientists did for you. How? Donate your physical or digital classified weapons records to the Lab’s National Security Research Center (NSRC), said Riz Ali, NSRC Director. The NSRC houses 80 years’ worth of one-of-kind records, which total in the millions and include nearly every medium imaginable. It is the Laboratory’s largest collection of research materials and the largest classified library of any Department of Energy lab. It all started with Oppenheimer, our first Lab director, and his Technical Library that was established during the Manhattan Project, which was the U.S. government’s top-secret effort to create the first atomic bombs to help end World War II. “Few NSRC patrons are aware that most of its vital materials come from the Lab’s own workforce,” said Chris C’de Baca, the NSRC’s Group Leader. “A significant portion of our critical material — which today’s researchers access regularly — is a direct contribution from research scientists. If people don’t contribute, then we won’t have the information we need when people come to the NSRC for research.”

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Ultra-low radioactivity Kapton and copper-Kapton laminates

Polyimide-based materials, like Kapton, are widely used in flexible cables and circuitry due to their unique electrical and mechanical characteristics. This study is aimed at investigating the radiopurity of Kapton for use in ultralow background, rare-event physics applications by measuring the 238U, 232Th, and natK levels using inductively coupled plasma mass spectrometry. Commercial-off-the-shelf Kapton varieties, mea- sured at approximately 950 and 120 pg/g 238U and 232Th (1.2×104 and 490 µBq/kg), respectively, can be a significant background source for many current and next-generation ultralow background detectors. This study has found that the dominant contamination is due to the use of dicalcium phosphate (DCP), a nonessential slip additive added during manufacturing. Alternative Kapton materials were obtained that did not contain DCP and were determined to be significantly more radiopure than the commercially- available options with 12 and 19 pg/g 238U and 232Th (150 and 77 µBq/kg), respectively. The lowest radioactivity version produced (Kapton ELJ, which contains an adhesive) was found to contain single digit pg/g levels of 238U and 232Th, two-to-three orders of magnitude cleaner than commercial-off-the- shelf options. Moreover, copper-clad polyimide laminates employing Kapton ELJ as the insulator were obtained and measured and showed to be very radiopure at 8.6 and 22 pg/g 238U and 232Th (110 and 89 µBq/kg), respectively.

Arnquist, Isaac J.↗

Expansion of the Fuel Motion Monitoring System

The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Deformation Mechanisms at Grain Boundaries in Polycrystals (Final Report)

Despite its significance in polycrystalline materials, there have been few experimental investigations of the activity of grain boundary sliding (GBS) and the relationship between GBS and slip transmission at grain boundaries. This work addressed this knowledge gap by an experimental and analytical investigation into the interactions between grain boundary sliding (GBS) and slip transmission plastic deformation mechanisms, and how these are impacted by local microstructure. Polycrystalline columnar aluminum of 99.99% purity was examined as a highly modellable system for characterizing grain boundary-local deformation mechanism interaction. High-resolution, large field-of-view strain fields and grain orientation information were captured and statistically analyzed to identify deformation activity with respect to the local microstructure, using a combination of scanning electron microscopy and digital image correlation (SEM-DIC) with electron backscatter diffraction (EBSD). Alignment between the lower-resolution electron backscatter diffraction (EBSD) data and the higher-resolution strain fields was significantly improved by clustering of strain data within an EBSD-defined boundary mantle. Although this work specifically focuses on characterizing the relationship between grain boundary sliding (GBS) and slip transmission, the developed experimental approach, multimodal data alignment process, and automated displacement discontinuity measurement process can be used to study a variety of mechanism interactions across a broad range of materials. Regarding GBS and slip transmission interaction, significant findings include that (1) grain boundaries that slide easily do not facilitate slip transmission; (2) substantial gradients in GBS magnitude could be found along the length of individual grain boundaries, and these were caused by strain discontinuities across the boundary related to deformation anisotropy between adjacent grains; (3) direct transmission and GBS were anti-compatible and facilitated by opposing boundary types (low misorientation and high energy grain boundaries respectively); (4) increased GBS activity was correlated with decreased indirect transmission behavior; (5) GBS accommodation at triple junctions was enabled by intragranular plasticity; and (6) the local intragranular plastic strain discontinuity between grains determined the magnitude of GBS gradients. The experimental strain fields were compared to that of a tangent crystal plasticity finite element (CPFE) model developed by collaborators (Mr. Ajey Venkataraman and Professor Michael Sangid, Purdue University). Implication of this work for improving CPFE models and deformation prediction are discussed. This work provides insight into the nature of these mechanisms and can be used to identify strain transfer criteria that can lead to improved GBS-sensitive crystal plasticity models.

36 MATERIALS SCIENCE↗

Physicochemical properties of digital light processing 3D-Printed alumina and mullite ceramics

Alumina ceramics fabricated using conventional techniques such as uniaxial pressing or injection molding are popular due to their low density, excellent insulation, and mechanical properties. However, these methods often limit the fabrication of complex geometries with high dimensional accuracy due to tooling constraints and limited design freedom. To overcome these limitations, this study employed Digital Light Processing (DLP) additive manufacturing (AM), which enables the production of precise structures. In addition, the optimization of sintering parameters to enhance the densification and performance of alumina and mullite ceramics was investigated, with a specific focus on how varying sintering temperatures and hold times affect part shrinkage, geometric accuracy, and material integrity. Flexural strength of both alumina and mullite specimens was clearly influenced by the way the layers was stacked. When layers were arranged across the direction of the applied load (Z = 4; XZ), the strength was higher than when they were stacked along the same direction as the load (Z = 3; XY). Weibull analysis based on these results showed high modulus values across all samples, indicating good reliability in the flexural strength measurements. This reliability, combined with the clear influence of sintering parameters, highlights how processing conditions effect the material properties and mechanical performance of parts produced through DLP additive manufacturing. In conclusion, these findings open new avenues for ceramic AM across various applications, enhancing the potential for innovation in fields such as aerospace, biomedical engineering, and energy.

36 MATERIALS SCIENCE↗

High strain-rate compression behavior of polymeric rod and plate Kelvin lattice structures

The compressive high strain-rate behavior of polymeric Kelvin lattice structures with rod-based or plate-based unit cells was investigated through experimental techniques and finite element simulations. Polymeric lattice structures with 5x5x5 unit cell geometries were manufactured on the millimeter scale using vat polymerization additive manufacturing and tested at low (0.001/s) and high (1000/s) strain-rates. High strain-rate experiments were performed and validated for a viscoelastic split-Hopkinson (Kolsky) pressure bar system (SHPB) coupled with high-speed imaging and digital image correlation (DIC). Experimental results at both low and high strain-rates show the formation of a localized deformation band which was more prevalent in low relative density specimens and low strain-rate experiments. Strain-rate effects of lattice specimens strongly correlate with effects of the base polymer material; both bulk polymer and lattice specimen demonstrated strain-rate hardening, strain-rate stiffening, and decreased fracture strain under dynamic loading. Results show mechanical failure properties and energy absorption depended strongly on the relative density of the lattice specimen and exhibited distinct scaling between relative density and geometry type (rod, plate) and loading rate. High relative density plate-lattices demonstrated inferior mechanical properties to rod-lattices; however, there exists a critical relative density for a given mechanical property (17%- 28%) below which plate-lattices outperform rod-lattices of similar mass. As a result, high strain-rate explicit finite element simulations were performed and showed good agreement with the mechanical failure trends and deformation modes observed in the experiments.

36 MATERIALS SCIENCE↗

In-Cell Deployment and First Use of Digital Image Correlation for In-Situ Strain Analysis of Irradiated Nuclear Fuel Rods During LOCA Transient

Digital image correlation (DIC) is a noncontact, optical method increasingly used across industries and research environments for acquiring multidimensional strain data. At Oak Ridge National Laboratory’s (ORNL’s) Severe Accident Test Station (SATS), DIC has been extensively applied to study the thermomechanical response of nuclear fuel claddings, yielding fundamental insights into material behavior. However, these efforts have focused exclusively on unirradiated materials and relied on the SATS out-of-cell infrastructure. Efforts over the past two years have been made to extend these capabilities to ORNL’s Irradiated Fuels Examination Laboratory SATS system within the hot-cells to enable testing of irradiated fuel cladding materials. Integrating DIC into the hot-cell SATS infrastructure presents unique challenges, including enabling remote operation of optical equipment and adapting auxiliary hot-cell systems for DIC implementation. This report discusses design, stand-up testing, and application of DIC to an irradiated nuclear fuel cladding segment. A DIC testing rig was successfully built and validated out-of-cell through extensive surrogate tests and calibrations. The rig and specialized DIC furnace were installed in the hot-cell, and a DIC test was successfully conducted. Results from that test correspond to expectations for Zr-based alloys and showed similar uncertainties compared to out-of-cell tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗

Neutron Capture and Transmission Measurements of 54 Fe at the RPI LINAC

54 Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54 Fe sample in the keV energy region. 54 Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54 Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C 6 D 6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54 Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54 Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54 Fe up to roughly 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Thermal Tomography Imaging System for In-Service Nondestructive Evaluation of Additively Manufactured Components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. We investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin. MIT research reactor (MITR) has been identified as a representative environment to perform investigation of feasibility of in-service NDE during shutdown. Preliminary study of radiation level in the MITR viewport, with geometric parameters potentially compatible with compact TT system, has been conducted.

36 MATERIALS SCIENCE↗

Pushing the limits of NAND technology scaling with ferroelectrics

Artificial intelligence (AI) continues to drive transformative advancements across various industries. The data-intensive nature of AI training (and inferencing) has resulted in the generation of unprecedented volumes of data with machine-generated content surpassing human-generated data by more than 100-fold in 2025. Efficiently managing this data influx necessitates advanced digital storage technologies. However, traditional NAND flash memory, which is critical for supporting data flows in AI systems—alongside high-bandwidth memory, for AI training—faces fundamental scaling limitations as it approaches the 1000-layer milestone, encompassing more than 40 trillion transistors. This article delves into the potential of hafnia-based ferroelectric materials as a breakthrough solution to these challenges. Recent advancements indicate that the intrinsic limitations of ferroelectric field-effect transistors (FEFETs) can be mitigated through material and device-level engineering. These advancements enable FEFETs to meet the stringent density, reliability, and scalability requirements of future three-dimensional NAND technology. The role of ferroelectrics in addressing NAND scaling challenges and expanding storage capabilities presents a promising avenue for meeting the storage demands of the AI-driven era.

3D NAND↗

Persistence Control of Engineered Functions in Complex Soil Microbiomes (PerCon SFA), Secure Biosystems Design Project Data Catalog at PNNL DataHub

The Persistence Control of Engineered Functions in Complex Soil Microbiomes Project (PerCon SFA) at Pacific Northwest National Laboratory (PNNL) is a Genomic Sciences Program Biosystems Design, Science Focus Area research project consortium. Collaborating across highly integrated institutions, PerCon SFA scientists are exploring how environmental niches can be sculpted using the mechanisms of genome reduction and metabolic addiction to drive secure rhizosphere community design for robust biomass cropping in challenging environments. The PerCon SFA DataHub project repository contains publication-relevant digital dataset and metadata DOI packages, enabling exploration and download of integrated experimental dataset catalogs publicly available to a global scientific community. and metadata repository allow for exploring and downloading integrated experimental biodesign omics dataset catalogs, including experimental protocols and/or workflows, raw and/or processed data, as required by the repository, and other relevant supporting materials and/or metadata required for research reproducibility and reporting.

59 BASIC BIOLOGICAL SCIENCES↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗