Search NASA⌕ Search

SEARCH · Search NASA

Results for “INDUCTIVE CHARGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Design and implementation of a Thomson parabola for fluence dependent energy-loss measurements at the Neutralized Drift Compression eXperiment

The interaction of ion beams with matter includes the investigation of the basic principles of ion stopping in heated materials. An unsolved question is the effect of different, especially higher, ion beam fluences on ion stopping in solid targets. This is relevant in applications such as in fusion sciences. To address this question, a Thomson parabola was built for the Neutralized Drift Compression eXperiment (NDCX-II) for ion energy-loss measurements at different ion beam fluences. The linear induction accelerator NDCX-II delivers 2 ns short, intense ion pulses, up to several tens of nC/pulse, or 1010-1011 ions, with a peak kinetic energy of ~1.1 MeV and a minimal spot size of 2 mm FWHM. For this particular accelerator, the energy determination with conventional beam diagnostics, for example, time of flight measurements, is imprecise due to the non-trivial longitudinal phase space of the beam. In contrast, a Thomson parabola is well suited to reliably determine the beam energy distribution. The Thomson parabola differentiates charged particles by energy and charge-to-mass ratio, through deflection of charged particles by electric and magnetic fields. During first proof-of-principle experiments, we achieved to reproduce the average initial helium beam energy as predicted by computer simulations with a deviation of only 1.4%25. Successful energy-loss measurements with 1 μm thick silicon nitride foils show the suitability of the accelerator for such experiments. The initial ion energy was determined during a primary measurement without a target, while a second measurement, incorporating the target, was used to determine the transmitted energy. The energy-loss was then determined as the difference between the two energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Cygnus Electrical Signals

The United States initiated the Subcritical Experiment (SCE) program to support a stockpile stewardship mission shortly after the 1992 moratorium on underground nuclear testing was established. Many SCE’s are conducted at the Nevada National Security Site (NNSS) in Nevada. Cygnus is a high-energy radiation generating device (RGD) located and operated at the NNSS and is a primary diagnostic for the SCE program. The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources, Cygnus 1 and Cygnus 2. From creation of the high power V-I drive to energy transport and X-ray conversion at the rod-pinch diode, the Cygnus machines utilize the following components: oil-filled Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line (CTL), three-cell vacuum induction voltage adder (IVA), and rod-pinch diode. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. Each source has the following X-ray specifications: 1 mm diameter, 4 rad at 1 m, and 50 ns radiation pulse. SCEs are both single-event and high-value; therefore, a high level of performance in reliability and reproducibility are key issues of Cygnus. Prior to executing such a SCE, there are a formidable number of shots (e.g., each of the two Cygnus RGDs charging and discharging properly into the rod-pinch diode load) that must be executed to determine reliability and reproducibility of the Cygnus RGDs. For every shot on Cygnus, voltages and currents along the machine are recorded and analyzed. In this paper we summarize attributes of the voltage and current waveforms at different locations using distribution plots. These distribution plots are used to quantify the reliability and reproducibility for Cygnus. This analysis methodology will provide a standard to trouble shoot results of individual Cygnus shots, and also to monitor long term Cygnus performance. Accordingly, this type of extensive analysis will contribute to optimized Cygnus performance on SCEs.

42 ENGINEERING↗

Quantum resistance standard accuracy close to the zero-dissipation state

We report on a comparison of four GaAs/AlGaAs-based quantum resistance standards using an original technique adapted from the well-known Wheatstone bridge. This work shows that the quantized Hall resistance at Landau level filling factor ν=2 can be reproducible with a relative uncertainty of 32×10{sup −12} in the dissipationless limit of the quantum Hall effect regime. In the presence of a very small dissipation characterized by a mean macroscopic longitudinal resistivity R{sub xx}(B) of a few μΩ, the discrepancy ΔR{sub H}(B) between quantum Hall resistors measured on the Hall plateau at magnetic induction B turns out to follow the so-called resistivity rule R{sub xx}(B)=αB×d(ΔR{sub H}(B))/dB. While the dissipation increases with the measurement current value, the coefficient α stays constant in the range investigated (40−120 μA). This result enlightens the impact of the dissipation emergence in the two-dimensional electron gas on the Hall resistance quantization, which is of major interest for the resistance metrology. The quantum Hall effect is used to realize a universal resistance standard only linked to the electron charge e and the Planck constant h and it is known to play a central role in the upcoming revised Système International of units. There are therefore fundamental and practical benefits in testing the reproducibility property of the quantum Hall effect with better and better accuracy.

36 MATERIALS SCIENCE↗

The Negative Mass Instability in an Enge "Pretzel" Magnet

A novel magnet invented by Harald Enge has the useful property of achromatically deflecting charged particle beams. One can envision many applications for these for transport and guiding in high-current electron beam research. However, a high-current electron beam bent by the magnetic field in one of these magnets is subject to the negative mass instability. The negative mass instability is a problem for all accelerators that rely on magnetic fields to bend or circulate the beam. The subject of this article is the assessment of this instability in these devices for a range of electron beam parameters typical of the linear induction accelerators (LIAs) at Los Alamos. We first describe the properties of the magnet, and then calculate the negative mass instability growth rate for a high current beam having parameters of interest. Finally, we show that the beam does not spend enough time circulating through the magnet for the instability to grow significantly.

43 PARTICLE ACCELERATORS↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗

Relationship between electromagnetic and acoustic emissions during plastic deformation of gamma-irradiated LiF monocrystals

Simultaneous measurements of acoustic emissions (AE) and electromagnetic emissions (EME) during plastic deformation and destruction under uniaxial compression along <001> direction are made on LiF monocrystals after gamma irradiation by {sup 60}Co source. The irradiation doses are 1, 2, and 10 Mrad. The EME measurements in the radio-frequency range are carried out using two types of electromagnetic sensors: (i) a simple electrical stub antenna and (ii) a toroidal inductance coil. Two checking experiments on unirradiated crystals are performed as the starting point to discover the effect of gamma irradiation on acoustic and electromagnetic emissive ability of plastically deformed ionic crystals. Unirradiated LiF monocrystals demonstrate high-intensive EME at easy glide and work hardening stages, as well as at the fracture during destruction of the sample. At radiation doses more than {approx}1 Mrad, in the active loading stage the EME of LiF monocrystals vanishes, except few individual electromagnetic pulses (only at 1 and 2 Mrad doses), which are time correlated with well-defined drop-jumps on the loading diagram and therefore can be associated with macroscopic crack openings. Moderate electromagnetic activity in irradiated crystals occurs only in the final stage of deformation at the complete fracture of the sample. Thus, after gamma irradiation the formation of polarization currents due to dynamic interaction between charged vacancies and moving dislocations is suppressed, and only EME connected with the redistribution of the free charge on the crack branches is observed. Acoustic emission diagrams of low-irradiated LiF are typical for the work hardening stage in crystals containing a great amount of strong point stoppers. At larger irradiation doses the AE diagram displays quite different behavior at low- and high-loading regions with a sharp boundary between them. The low-loading region shows poor AE activity, which changes sharply into high-active burst-like emission with an increase in loading. The boundary between two regions shifts to higher loadings with radiation dose. The higher is the radiation dose the lower is the relative intensity of AE in the high-stressed region. The physical mechanisms of EME and AE in gamma-irradiated ionic crystals are discussed.

36 MATERIALS SCIENCE↗

Study on spatial distribution of plasma parameters in a magnetized inductively coupled plasma

Spatial distributions of various plasma parameters such as plasma density, electron temperature, and radical density in an inductively coupled plasma (ICP) and a magnetized inductively coupled plasma (M-ICP) were investigated and compared. Electron temperature in between the rf window and the substrate holder of M-ICP was higher than that of ICP, whereas the one just above the substrate holder of M-ICP was similar to that of ICP when a weak (<8 G) magnetic field was employed. As a result, radical densities in M-ICP were higher than those in ICP and the etch rate of oxide in M-ICP was faster than that in ICP without severe electron charging in 90 nm high aspect ratio contact hole etch.

36 MATERIALS SCIENCE↗

Plasma Sputter-type Ion Source with Wire Electrodes for Low-energy Gallium Ion Extraction

Low-energy ions of gallium (Ga) and argon (Ar) were extracted from a plasma sputter-type ion source system that utilized a tungsten (W) wire extractor geometry. The 90% transparent W wire extractor configuration had shown that the system was capable of producing an ion beam with the energy as low as 10 eV in a dc filament discharge and 50 eV in a radio frequency (rf) excited system. In the present investigation, Ar plasma was sustained in an ion source chamber through an inductively coupled 13.56 MHz rf power source. Negatively biased liquid Ga target suspended on a W reservoir was sputtered and postionized prior to extraction. Mass spectral analyses revealed a strong dependence of the Ga{sup +} current on the induced target bias.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observations of a mode transition in a hydrogen hollow cathode discharge using phase resolved optical emission spectroscopy

Two distinct operational modes are observed in a radio frequency (rf) low pressure hydrogen hollow cathode discharge. The mode transition is characterised by a change in total light emission and differing expansion structures. An intensified CCD camera is used to make phase resolved images of Balmer α emission from the discharge. The low emission mode is consistent with a typical γ discharge, and appears to be driven by secondary electrons ejected from the cathode surface. The bright mode displays characteristics common to an inductive discharge, including increased optical emission, power factor, and temperature of the H{sub 2} gas. The bright mode precipitates the formation of a stationary shock in the expansion, observed as a dark region adjacent to the source-chamber interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two mechanisms for dissipation of excess light in monomeric and trimeric light-harvesting complexes

Oxygenic photoautotrophs require mechanisms for rapidly matching the level of chlorophyll excited states from light harvesting with the rate of electron transport from water to carbon dioxide. These photoprotective reactions prevent formation of reactive excited states and photoinhibition. The fastest response to excess illumination is the so-called non-photochemical quenching which, in higher plants, requires the luminal pH sensor PsbS and other yet unidentified components of the photosystem II antenna. Both trimeric light-harvesting complex II (LHCII) and monomeric LHC proteins have been indicated as site(s) of the heat-dissipative reactions. Different mechanisms have been proposed: Energy transfer to a lutein quencher in trimers, formation of a zeaxanthin radical cation in monomers. Here, we report on the construction of a mutant lacking all monomeric LHC proteins but retaining LHCII trimers. Its non-photochemical quenching induction rate was substantially slower with respect to the wild type. A carotenoid radical cation signal was detected in the wild type, although it was lost in the mutant. Here, we conclude that non-photochemical quenching is catalysed by two independent mechanisms, with the fastest activated response catalysed within monomeric LHC proteins depending on both zeaxanthin and lutein and on the formation of a radical cation. Trimeric LHCII was responsible for the slowly activated quenching component whereas inclusion in supercomplexes was not required. Finally, this latter activity does not depend on lutein nor on charge transfer events, whereas zeaxanthin was essential.

Antenna complex↗

Microwave Annealing of Ion Implanted 4H-SiC

Ultra-fast high-temperature microwave annealing at temperatures as high as 2050 deg. C for 30 s has been performed on phosphorus ion-implanted 4H-SiC for phosphorus doping concentrations in the range 5x10{sup 19} cm{sup -3}-8x10{sup 20} cm{sup -3}. For comparison, inductive heating furnace anneals were performed at 1800 deg. C-1950 deg. C for 5 min. Electrical resistivity of the P{sup +}-implanted samples decreased with increasing annealing temperature reaching a minimum value of 6.8x10{sup -4} {Omega}cm for 2050 deg. C/30 s microwave annealing and a slightly higher value for 1950 deg. C/5 min inductive heating furnace annealing. X-ray rocking curve measurements showed that the microwave annealing not only removed the lattice damage introduced by the ion-implantation process, but also the defects present in the original virgin sample as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental investigation on plasma parameter profiles on a wafer level with reactor gap lengths in an inductively coupled plasma

The gap length effect on plasma parameters is investigated in a planar type inductively coupled plasma at various conditions. The spatial profiles of ion densities and the electron temperatures on the wafer level are measured with a 2D probe array based on the floating harmonic method. At low pressures, the spatial profiles of the plasma parameters rarely changed by various gap lengths, which indicates that nonlocal kinetics are dominant at low pressures. However, at relatively high pressures, the spatial profiles of the plasma parameter changed dramatically. These plasma distribution profile characteristics should be considered for plasma reactor design and processing setup, and can be explained by the diffusion of charged particles and the local kinetics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Survey of Thermocouple Anomalies: Mechanisms, Interpretation, and Mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

Thermocouple Anomalies↗

Shock tube and shock wave research; Proceedings of the Eleventh International Symposium, University of Washington, Seattle, Wash., July 11-14, 1977

Papers are presented on the applications of shock-wave technology to the study of hydrodynamics, the use of the pressure-wave machine for charging diesel engines, and measurements of the heat-transfer rate in gas-turbine components. Consideration is given to shock propagation along 90-degree bends, the explosive dissemination of liquids, and rotational and vibrational relaxation behind weak shock waves in water vapor. Shock phenomena associated with expansion flows are described and stratospheric-related research using the shock tube is outlined. Attention is given to shock-wave ignition of magnesium powders, Mach reflection and boundary layers, and transition in the shock-induced unsteady boundary layer on a flat plate. Shock-tube measurements of induction and post-induction rates for low-Btu gas mixtures are presented and shock-initiated ignition in COS-N2O-Ar mixtures is described. Cluster growth rates in supersaturated lead vapor are presented and a study of laser-induced plasma motion in a solenoidal magnetic field is reviewed.

Ahlborn, B.↗

NASA Tech Briefs, November 2006

Topics include: Simulator for Testing Spacecraft Separation Devices; Apparatus for Hot Impact Testing of Material Specimens; Instrument for Aircraft-Icing and Cloud-Physics Measurements; Advances in Measurement of Skin Friction in Airflow; Improved Apparatus for Testing Monoball Bearings; High-Speed Laser Scanner Maps a Surface in Three Dimensions; Electro-Optical Imaging Fourier-Transform Spectrometer; Infrared Instrument for Detecting Hydrogen Fires; Modified Coaxial Probe Feeds for Layered Antennas; Detecting Negative Obstacles by Use of Radar; Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators; PixelLearn; New Software for Predicting Charging of Spacecraft; Conversion Between Osculating and Mean Orbital Elements; Generating a 2D Representation of a Complex Data Structure; Making Activated Carbon by Wet Pressurized Pyrolysis; Composite Solid Electrolyte Containing Li+- Conducting Fibers; Electrically Conductive Anodized Aluminum Surfaces; Rapid-Chill Cryogenic Coaxial Direct-Acting Solenoid Valve; Variable-Tension-Cord Suspension/Vibration- Isolation System; Techniques for Connecting Superconducting Thin Films; Versatile Friction Stir Welding/Friction Plug Welding System; Thermal Spore Exposure Vessels; Enumerating Spore-Forming Bacteria Airborne with Particles; Miniature Oxidizer Ionizer for a Fuel Cell; Miniature Ion-Array Spectrometer; Promoted-Combustion Chamber with Induction Heating Coil; Miniature Ion-Mobility Spectrometer; Mixed-Salt/Ester Electrolytes for Low-Temperature Li+ Cells; Miniature Free-Space Electrostatic Ion Thrusters; Miniature Bipolar Electrostatic Ion Thruster; Holographic Plossl Retroreflectors; Miniature Electrostatic Ion Thruster With Magnet; Using Apex To Construct CPM-GOMS Models; Sequence Detection for PPM Optical Communication With ISI; Algorithm for Rapid Searching Among Star-Catalog Entries; Expectation-Based Control of Noise and Chaos; Radio Heating of Lunar Soil to Release Gases; Using Electrostriction to Manipulate Ullage in Microgravity; Equations for Scoring Rules When Data Are Missing; Insulating Material for Next-Generation Spacecraft; and Pseudorandom Switching for Adding Radar to the AFF Sensor.

Source record↗

Energetic electron avalanches and mode transitions in planar inductively coupled radio-frequency driven plasmas operated in oxygen

Space and phase resolved optical emission spectroscopic measurements reveal that in certain parameter regimes, inductively coupled radio-frequency driven plasmas exhibit three distinct operation modes. At low powers, the plasma operates as an alpha-mode capacitively coupled plasma driven through the dynamics of the plasma boundary sheath potential in front of the antenna. At high powers, the plasma operates in inductive mode sustained through induced electric fields due to the time varying currents and associated magnetic fields from the antenna. At intermediate powers, close to the often observed capacitive to inductive (E-H) transition regime, energetic electron avalanches are identified to play a significant role in plasma sustainment, similar to gamma-mode capacitively coupled plasmas. These energetic electrons traverse the whole plasma gap, potentially influencing plasma surface interactions as exploited in technological applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of the ion toroidal rotation source due to momentum transfer from Lower Hybrid waves in Alcator C-Mod

Significant ion toroidal rotation (50km/s) has been measured by X-Ray spectroscopy for impurities in Alcator C-Mod during lower hybrid (LH) RF power injection. We investigate the relation between the computed toroidal momentum input from LH waves and the measured INITIAL change of ion toroidal rotation when the LH power is turned on. The relation may depend on the plasma current and magnetic configuration. Because of the fast build up time of the electron quasilinear plateau (<1 millisecond), the electron distribution function rapidly reaches steady state in which the electrons transfer momentum to the ions. The LH wave momentum input is computed from the self consistent steady state electron distribution function and a bounce-averaged quasilinear diffusion coefficient that are obtained by iterating a full wave code (TORLH) with a Fokker Plank code (CQL3D)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct Measurement of Backstreaming Ions from the Axis 2 Septum Dump and RF Generation

The DARHT-II accelerator produces a 2-kA, 17-MeV beam in a 1600-ns pulse. After exiting the accelerator, the pulse is sliced into four short pulses by a kicker and quadrupole septum and then transported for several meters to a high Z material target for conversion to x-rays for radiography. The un-kicked beam is diverted to a graphite dump. The interaction of this beam with the dump produces ions that propagate back to the target beamline and affect the beam properties. Coupling of the electron beam and ions to the beam dump vacuum chamber can also produce significant amounts of radiofrequency fields (RF) that disrupt the beam transport to the target. This requires a change in the nominal tune in order to minimize the heating of the carbon beam dump and suppress desorption of ions. Initially, ions are generated through stimulated desorption and ionization of the monolayers of water vapor stuck to the beam dump surface. These ions propagate upstream at high speeds and act as an electrostatic focusing lens by reducing the beam space charge. As the beam size on the dump decreases, the dump is sufficiently heated so that a surface plasma is formed and much greater quantities of ions are generated through temperature limited thermionic emission. The interaction of these ions with the beam creates RF which causes significant disruption of the beam. The results of a 3D PIC simulation show that ions can propagate back to the target beam line in about 500 ns. A beam position monitor (BPM) located just upstream of the septum was modified to include four capacitive pickups in addition to four of the usual inductive pickups. The inductive and capacitive pickups provide a measure of the beam current. The capacitive pickups are very sensitive to low velocity ions. As ions from the beam dump pass through the BPM the inductive and capacitive pickup will record two different measures of the beam current. Initial results from this BPM will be discussed along with other measurements which indicate the presence of backstreaming ions.

43 PARTICLE ACCELERATORS↗