At least 487 records · Page 27

Characterization of Microwave Loss Using Multimode Superconducting Resonators

Measuring the losses arising from different materials and interfaces is crucial to improving the coherence of superconducting quantum circuits. Although this has been of interest for a long time, current studies can either only provide bounds to those losses, or require several devices for a complete characterization. In this work, we introduce a method to measure the microwave losses of materials and interfaces with a single multi-mode superconducting resonator. We demonstrate a formalism for analyzing the loss sensitivity of multi-mode systems and discuss the design strategies of multi-mode resonators for material loss studies. We present two types of multi-mode superconducting resonators for the study of bulk superconductors: the forky whispering-gallery-mode resonator (FWGMR) and the ellipsoidal cavity. We use these resonators to measure the surface dielectric, conductor, and seam losses of high-purity (5N5) aluminum and aluminum alloy (6061), as well as how they are affected by chemical etching, diamond turning, and thin-film coating. Here, we find that chemical etching and diamond turning reduce both the surface dielectric and conductive losses of high-purity aluminum, but provide no appreciable improvement to the seam. Coating the surfaces of diamond-turned aluminum alloys with e-beam evaporated or sputtered aluminum thinfilms significantly reduces all three losses under study. In addition, we study the effect of chemical etching on the surface of high-purity aluminum using transmission electron microscopy (TEM) and find that the chemical etching process creates a thinner and more uniform oxide layer, consistent with the observed improvement in the surface dielectric loss.

25 ENERGY STORAGE↗

A two-directional vibrational probe reveals different electric field orientations in solution and an enzyme active site

We report the catalytic power of an electric field depends on its magnitude and orientation with respect to the reactive chemical species. Understanding and designing new catalysts for electrostatic catalysis thus requires methods to measure the electric field orientation and magnitude at the molecular scale. We demonstrate that electric field orientations can be extracted using a two-directional vibrational probe by exploiting the vibrational Stark effect of both the C=O and C–D stretches of a deuterated aldehyde. Combining spectroscopy with molecular dynamics and electronic structure partitioning methods, we demonstrate that, despite distinct polarities, solvents act similarly in their preference for electrostatically stabilizing large bond dipoles at the expense of destabilizing small ones. In contrast, we find that for an active-site aldehyde inhibitor of liver alcohol dehydrogenase, the electric field orientation deviates markedly from that found in solvents, which provides direct evidence for the fundamental difference between the electrostatic environment of solvents and that of a preorganized enzyme active site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy scale and resolution for anti-$k_t$ jets with radius parameters $R$ = 0.2 and 0.6 measured in proton-proton collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

Jets with different radius parameters R are an important tool for probing quantum chromodynamics processes at different angular scales. Jets with small R = 0.2 are instrumental in measurements of the substructure of large-R jets resulting from collimated hadronic decays of energetic W, Z, and Higgs bosons, top quarks, and of potential new resonances. This paper presents measurements of the energy scale, resolution, and associated uncertainties of jets with radius parameters R = 0.2 and 0.6, obtained using the ATLAS detector. The results are based on 37 fb -1 of proton–proton collision data from the Large Hadron Collider at a centre-of-mass energy of $\sqrt{s}$ = 13 TeV. A new in situ method for measuring jet energy scale differences between data and Monte Carlo simulations is presented. The systematic uncertainties in the jet energy scale for central jets $(|\eta | < 1.2)$ typically vary from 1% to about 5% as a function of $|\eta |$ at very low transverse momentum, $p_T$ of around 20 GeV for both R = 0.2 and 0.6 jets. The relative energy resolution ranges from (35 ± 6)% at $p_T$ = 20 GeV to (6 ± 0.5)% at $p_T$ = 300 GeV for central R = 0.2 jets, and is found to be slightly worse for R + 0.6 jets. Finally, the effect of close-by hadronic activity on the jet energy scale is investigated and is found to be well modelled by the ATLAS Monte Carlo simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hydrogen Permeation Analysis Tool

There is a rising need for the measurement and understanding of hydrogen transport properties in materials for the energy and transportation industries. The Hydrogen Permeation Analysis Tool (HyPAT) provides a user friendly interface for batch analysis of dynamic hydrogen permeation data to calculate the transport properties permeability, solubility, and diffusivity. A built in literature database provides an easy comparison to known values. A common method for measuring these hydrogen transport properties is dynamic pressure rise permeation experiments, for example, those done in the Static Gas Absorption and Permeation (SGAP) experiment at INL. Most laboratories develop individual, in-house codes for data analysis. HyPAT provides a platform that can be adopted by other user groups for such experimental analysis and significantly reduce personnel time spent performing data analysis.

Fuerst, ThomasF↗

Reducing Sample Loss in Measurement of Heat of Vaporization of Ethanol/Gasoline Blends by Differential Scanning Calorimetry/Thermogravimetric Analysis

Higher gasoline Heat of Vaporization (HOV) can enable higher compression-ratio direct injection spark ignition engines by providing evaporative cooling that effectively increases fuel knock resistance. Methods to directly measure this fuel property in complex gasoline samples are not well developed. The objective of the present study was to further improve a Differential Scanning Calorimetry/Thermogravimetric Analyzer (DSC/TGA) method to measure the total and partial HOV of gasoline. Ten market gasoline samples were chosen to have a wide range of properties to assess the method's capability across the entire volatility range with an emphasis on understanding how well the method captures the initial 10 percent (%) of sample evaporation and how much sample is left unevaporated at the end of the experiment. Modifications to the sample preparation/introduction method as well as to the instrument itself were made to reduce initial sample losses which included measurements of the HOV at 10 degrees C and 5 degrees C (in a cold chamber) as well as under (uncontrolled) ambient conditions. Experimental results from the DSC/TGA were compared to calculated total HOV results based on Detailed Hydrocarbon Analysis (DHA). Results from the two methods agreed very well with the difference being 5% or less in almost every case. In addition, the repeatability of the method was investigated by analyzing samples in triplicate at the three temperatures investigated. One valuable conclusion from the study was that the lower temperatures of 10 degrees C and 5 degrees C enabled more reproducible measurements for both total and partial HOV. This improved precision may be caused by the fact that temperature control in the cold chamber was more reliable than the ambient laboratory temperature control. Additionally, cold chamber experiments, due to ergonomic limitations, did not allow for the use of a lid on the sample pan. The reproducibility of the evaporation rate was found to be highly dependent on the pan/lid fit which can vary significantly such that elimination of the lid improved measurement precision while operation at sub-ambient temperature slowed the evaporation rate. Results detailing sample preparation and instrument modifications as well as a detailed comparison of total and partial HOV results are presented.

ADVANCED PROPULSION SYSTEMS,BIOMASS FUELS↗

Measuring sub-surface spatially varying thermal conductivity of silicon implanted with krypton

The thermal properties of semiconductors following exposure to ion irradiation are of great interest for the cooling of electronic devices; however, gradients in composition and structure due to irradiation often make the measurement difficult. Furthermore, the nature of spatial variations in thermal resistances due to spatially varying ion irradiation damage is not well understood. In this work, we develop an advancement in the analysis of time-domain thermoreflectance to account for spatially varying thermal conductivity in a material resulting from a spatial distribution of defects. We then use this method to measure the near-surface (≲1 μm) thermal conductivity of silicon wafers irradiated with Kr + ions, which has an approximate Gaussian distribution centered 260 nm into the sample. Our numerical analysis presented here allows for the spatial gradient of thermal conductivity to be extracted via what is fundamentally a volumetric measurement technique. We validate our findings via transmission electron microscopy, which is able to confirm the spatial variation of the sub-surface silicon structure, and provide additional insight into the local structure resulting from the effects of ion bombardment. Thermal measurements found the ion stopping region to have a nearly 50x reduction in thermal conductivity as compared to pristine silicon, while TEM showed the region was not fully amorphized. Our results suggest this drastic reduction in silicon thermal conductivity is primarily driven by structural defects in crystalline regions along with boundary scattering between amorphous and crystalline regions, with a negligible contribution being due to implanted krypton ions themselves.

36 MATERIALS SCIENCE↗

Determining Proton Transport in Pseudo Catalyst Layers Using Hydrogen Pump DC and AC Techniques

Optimizing electrode morphology with a more uniform ionomer distribution is key to reducing ohmic losses and increasing electrocatalyst utilization in polymer electrolyte fuel cells (PEFCs). Inherent ionomer conductivity, volume fraction and tortuosity determine effective ionic conductivity. We use hydrogen pump (HP) method to measure effective ionic conductivity of a pseudo catalyst layer (PCL) comprised of Vulcan XC-72 carbon black and 3M 825 EW ionomer with ionomer to carbon (I/C) ratios of 0.6, 1 and 1.4 and relative humidity (RH) range of 50 to 120%. These direct current (DC) experiments are then compared with electrochemical impedance spectroscopy (EIS). Both DC and EIS methods show good agreement, indicating that EIS can be used as an alternative to DC method in HP experiment. Ionic conductivity for PCL with I/C of 1 and 1.4 was found to be about one order of magnitude higher than I/C of 0.6 for most of the RH range. At 90% RH tortuosities for I/C = 1 and 1.4 were close to 1, whereas tortuosity for I/C = 0.6 was 3. With decrease in relative humidity tortuosities increased linearly and at 50% relative humidity a PCL with I/C = 0.6 had the highest tortuosity of 6.1.

25 ENERGY STORAGE↗

Measurement of the Hubble constant with high-energy neutrinos

Measuring distances in the Universe is one of the hardest problems in physics and astronomy. Almost every distance probe relies on photons, whose propagation across cosmic distances introduces extinction, absorption, scattering, and radiative-transfer effects. Neutrinos suffer none of these and propagate unattenuated through dust, intergalactic medium, and dense source environments alike. We introduce a new distance-ladder method for measuring the Hubble constant $H_0$ using high-energy astrophysical neutrinos from point sources as standardizable candles, and report its first observational realization. Using 12 X-ray-selected Seyfert galaxies for which IceCube reports significant per-source neutrino excesses in its 14-year public point-source release, we exploit the disk-corona correlation $L_ν= κ\, L_X^β$ between neutrino and X-ray luminosities to construct a neutrino distance ladder anchored by non-redshift distances to NGC 1068 (Cepheid + TRGB). We find $H_0 = 49^{+40}_{-30}\,\mathrm{km\,s^{-1}\,Mpc^{-1}}$ and $β= 0.67^{+0.16}_{-0.25}$ (68% credible intervals), with the corona slope disfavoring the calorimetric limit $β= 1$ at ${\sim}2σ$. The result is consistent with existing $H_0$ determinations from Planck and SH0ES within 1$σ$. While the uncertainty on $H_0$ is large, the measurement is free of electromagnetic propagation systematics and demonstrates the viability of neutrinos as a novel cosmographical probe.

Herrera, Gonzalo [MIT, MKI; Harvard U.] (ORCID:000↗

Discovery of complex oxides via automated experiments and data science

Significance Automation is accelerating the discovery of useful materials, yet testing even a small fraction of the billions of possible materials for a desired property is beyond the reach of workflows involving resource-intensive property measurements. Due to relationships among composition, structure, and properties, identifying a complex material with one interesting property makes it the proverbial needle in a haystack that merits testing for additional properties. We accelerate materials synthesis and optical characterization by employing physics-aware data science to identify materials for further investigation. With this approach, one does not need high-throughput methods for measuring every material property of interest since a single ultra-high–throughput workflow can guide material selection for other properties, which is a new paradigm for accelerated materials discovery.

36 MATERIALS SCIENCE↗

Application of the Solute-Solvent EMF Cell to Measure Activity of NiF 2 in Molten FLiNaK

Electromotive force (emf) measurements made using a combination of solute- and solvent-based electrodes were used to determine the activity of NiF 2 in molten FLiNaK eutectic at 823 K across a concentration range of x NiF2 = 5.2 × 10 –4 –1.0 × 10 –2 . The solute emf values were measured using electrodes consisting of Ni wires immersed in FLiNaK with dissolved NiF 2 contained in graphite crucibles. The measured emf values were then converted to the FLiNaK Eutectic Potassium Electrode (FEKE) potential and used to quantify the activity of dissolved NiF 2 . This quantification was based upon comparative measurements of a reference solvent electrode consisting of a K-Bi alloy immersed in pure FLiNaK contained in a boron nitride crucible and a solute electrode. Short cell lives were characteristic of the measurements due to the corrosive nature of the fluoride salts. Quantifying the activity of NiF 2 will improve the utility of Ni 2+ /Ni reference electrodes in molten fluoride salts, which are notoriously difficult electrolytes to work with because of their reactivity. In conclusion, this work demonstrates the general nature of the solute-solvent approach as a repeatable, easily employed method for measuring the activity values of electroactive species in a variety of molten salts to improve understanding of the electroactive species behavior in these systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inverse point source location with the Helmholtz equation on a bounded domain

The problem of recovering acoustic sources, more specifically monopoles, from point-wise measurements of the corresponding acoustic pressure at a limited number of frequencies is addressed. To this purpose, a family of sparse optimization problems in measure space in combination with the Helmholtz equation on a bounded domain is considered in this study. A weighted norm with unbounded weight near the observation points is incorporated into the formulation. Optimality conditions and conditions for recovery in the small noise case are discussed, which motivates concrete choices of the weight. The numerical realization is based on an accelerated conditional gradient method in measure space and a finite element discretization.

97 MATHEMATICS AND COMPUTING↗

Counting mRNA copies in intact bacterial cells by fluctuation localization imaging-based fluorescence in situ hybridization (fliFISH)

A method for measuring mRNA copies in intact bacterial cells by fluctuation localization imaging-based fluorescence in situ hybridization (fliFISH) is presented. Unlike conventional single molecule FISH, where the presence of a transcript is determined by fluorescence intensity, fliFISH relies on On-Off duty cycles of photo-switching dyes to set a predetermined threshold for distinguishing true signals from background noise. The method provides a quantitative approach for detecting and counting true mRNA copies and rejecting false signals with high accuracy.

Hu, Dehong↗

Ultrafast terahertz spectroscopy provides insight into charge transfer efficiency and dynamics in artificial photosynthesis

Terahertz (THz) spectroscopy provides a noncontact method to measure the ultrafast dynamics and photoconductivity of mobile carriers in semiconducting materials. This has proven useful in studying artificial photosynthesis devices which use semiconductor photoelectrodes. In this work, we present a brief introduction to optical-pump THz-probe (OPTP) spectroscopy, a technique that provides unique and useful insight into interfacial electron transfer (from the surface-attached dye to the conduction band of the semiconductor) in dye-sensitized photoelectrochemical cells. Compared with more familiar methods like visible transient absorption spectroscopy, OPTP spectroscopy stands out in offering both sub-picosecond time resolution as well as sensitivity to mobile carriers (electrons and holes) in the semiconductor portion of artificial photosynthesis devices. The mobile carriers are crucial to device performance as only they pass to the other half cell to complete the reaction. In order to highlight these advantages and illustrate the types of questions OPTP spectroscopy can address, we discuss three case studies. In the first, OPTP spectroscopy is used to measure the injection rates from a set of six different dyes, revealing the effect of the energetics and lifetimes of the dye excited states on interfacial electron transfer. The subsequent case studies investigate the influence of varying the moieties which bind to the surface (anchors), as well as the moieties that connect the chromophore with these anchors (linkers). OPTP spectroscopy was used to measure the interfacial electron transfer rate as these moieties were varied.

59 BASIC BIOLOGICAL SCIENCES↗

Studies of e+e- Pair Photo-Production on Proton Target at 8 GeV in the GlueX Experiment

Lepton pair production has played an important role in both nuclear and particle physics, being among the earliest calculations utilizing QED, and seen most famously in the discovery of the J= at BNL. A technique is presented for measuring the linear polarization of GeV scale photon beams through the detection of e+e? pairs photo-produced in the target. This technique is applied to the analysis of GlueX data on proton target. Simulation predicts the analyzing power for pair production to be :5725 ? 0:0025 for the GlueX data, and the analysis of experimental data gives a linear polarization of approximately 35%, in good agreement with other measurements of beam polarization. The pair production technique is complementary to other electromagnetic and hadronic measurements of beam polarization, and is generally applicable in experiments that allow for forward angle electron and positron identi?fication and tracking. To facilitate this study, a neural net was trained for e=? separation to eliminate the pion background. Further, it is demonstrated that these e+e? pairs are sensitive to the proton charge form factor, which opens up the possibility for a new method to measure the proton RMS charge radius.

Schick, Andrew↗

Platform for Single-Cell Dual RNA Sequencing of Host-Pathogen Interactions

The aim of this project was to advance single-cell RNA-Seq methods toward the establishment of a platform that may be used to simultaneously interrogate the gene expression profiles of mammalian host cells and bacterial pathogens. Existing genetic sequencing methods that measure bulk groups of cells do not account for the heterogeneity of cell-microbe interactions that occur within a complex environment, have limited efficiency, and cannot simultaneously interrogate bacterial sequences. In order to overcome these challenges, separate biochemistry workflows were developed based on a No-So-Random hexamer priming strategy or libraries of targeted molecular probes. Computational tools were developed to facilitate these methods, and feasibility was demonstrated for single-cell RNA-Seq for both bacterial and mammalian transcriptomes. This work supports cross-agency national priorities on addressing the threat of biological pathogens and understanding the role of the microbiome in modulating immunity and susceptibility to infection.

59 BASIC BIOLOGICAL SCIENCES↗

Aerosol jet printed 3 omega sensors for thermal conductivity measurement

The 3 omega (3ω) method is a trusted technique for measuring thermal conductivity—a fundamental material property of critical importance in a broad range of applications. However, traditional 3ω sensor processing requires some form of physical vapor deposition, such as metal evaporation or sputtering. These 3ω sensor deposition techniques limit the materials and sample sizes applicable to the 3ω method. This work demonstrates an aerosol jet printing method to directly print silver 3ω sensors that yield accurate temperature-dependent measurement up to 300 °C on materials with thermal conductivity ranging from 1 to 150 W/m K. The interrelationship between printed sensor geometry, sensor thermal stability, and applicability to the 3ω method is examined. Thermal conductivity measurement with 3ω sensors conventionally sintered at 300 °C agrees to independent laser flash measurement within 4% from room temperature to 150 °C. An unconventional rapid high-temperature sintering method is shown to produce sensors that agree within 3% of the laser flash measurements from room temperature to 300 °C. The rapid sintering profiles also reduced the sensor–substrate thermal boundary resistance of the printed sensors by as much as 88%. The direct printing of 3ω sensors creates opportunities for measurement of thermal transport properties in applications previously inapplicable to the 3ω method.

47 OTHER INSTRUMENTATION↗

Hierarchical Modeling to Enhance Spectrophotometry Measurements—Overcoming Dynamic Range Limitations for Remote Monitoring of Neptunium

A robust hierarchical model has been demonstrated for monitoring a wide range of neptunium concentrations (0.75–890 mM) and varying temperatures (10–80 °C) using chemometrics and feature selection. The visible–near infrared electronic absorption spectrum (400–1700 nm) of monocharged neptunyl dioxocation (Np(V) = NpO2+) includes many bands, which have molar absorption coefficients that differ by nearly 2 orders of magnitude. The shape, position, and intensity of these bands differ with chemical interactions and changing temperature. These challenges make traditional quantification by univariate methods unfeasible. Measuring Np(V) concentration over several orders of magnitude would typically necessitate cells with varying path length, optical switches, and/or multiple spectrophotometers. Alternatively, the differences in the molar extinction coefficients for multiple absorption bands can be used to quantify Np(V) concentration over 3 orders of magnitude with a single optical path length (1 mm) and a hierarchical multivariate model. In this work, principal component analysis was used to distinguish the concentration regime of the sample, directing it to the relevant partial least squares regression submodels. Each submodel was optimized with unique feature selection filters that were selected by a genetic algorithm to enhance predictions. Through this approach, the percent root mean square error of prediction values were ≤1.05% for Np(V) concentrations and ≤4% for temperatures. This approach may be applied to other nuclear fuel cycle and environmental applications requiring real-time spectroscopic measurements over a wide range of conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Life cycle of a cyanobacterial carboxysome

Carboxysomes, prototypical bacterial microcompartments (BMCs) found in cyanobacteria, are large (~1 GDa) and essential protein complexes that enhance CO 2 fixation. While carboxysome biogenesis has been elucidated, the activity dynamics, lifetime, and degradation of these structures have not been investigated, owing to the inability of tracking individual BMCs over time in vivo. In this work, we have developed a fluorescence-imaging platform to simultaneously measure carboxysome number, position, and activity over time in a growing cyanobacterial population, allowing individual carboxysomes to be clustered on the basis of activity and spatial dynamics. We have demonstrated both BMC degradation, characterized by abrupt activity loss followed by polar recruitment of the deactivated complex, and a subclass of ultraproductive carboxysomes. Together, our results reveal the BMC life cycle after biogenesis and describe the first method for measuring activity of single BMCs in vivo.