Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Geothermal Heat Pump System Showcase: Short-Term Validation of Borehole Heat Exchanger Performance from Field Data to Numerical Modeling: Preprint

Since 2011, a geothermal heat pump (GHP) system has been operating to provide space heating and cooling for the Solar Radiation and Research Laboratory building at the National Laboratory of the Rockies (NLR) in Golden, Colorado. The system consists of 23 vertical boreholes, each extending to a depth of 300 ft (91 m), connected to 11 water-to-air heat pump units and four circulation pumps. Between fiscal years 2023 and 2025, additional power meters and temperature sensors were retrofitted to support detailed system performance assessment and model development. This study presents preliminary monitoring results and the development of an initial numerical model of the borehole heat exchanger field. The model incorporated site-specific geometry, ground thermal properties derived from thermal response tests, and ambient temperatures, and simulated system behavior over a representative operating day in September. Model predictions of outlet temperatures were compared against corresponding field measurements. Results showed that modeling initialized with a simplified linear subsurface temperature gradient presents systematic discrepancies in outlet temperature, whereas incorporating depth-resolved borehole temperature measurements for initialization yields substantially improved agreement with observations. The findings highlight the sensitivity of short-term predictive modeling to the representation of initial subsurface thermal conditions and underscore the value of high-resolution field measurements for model calibration and validation. These preliminary results inform ongoing efforts to extend the modeling framework to longer time horizons and to refine monitoring and modeling strategies that support the design guidance and operational optimization of GHP systems in research and commercial buildings.

15 GEOTHERMAL ENERGY↗

Wholesale Electricity Markets and Resource Adequacy with High Clean Energy Generation Targets

Wholesale electricity markets are intended to incentivize system generation investments and operations outcomes that meet evolving system needs. In this work, we evaluate the effectiveness of wholesale market structures, rules and policies in achieving system resource adequacy (RA) and clean energy targets in the presence of self-interested generation investors using the Electricity Markets and Investment Suite Agent-based Simulation (EMIS-AS) model. Results highlight that both capacity markets and operating reserve demand curves (ORDCs) can help achieve a reliable system but with different RA compliance timelines and distribution of generation technologies. Structures with capacity markets tend to favor more capital-intensive peaking technologies while reducing wind and solar build-outs due to suppressed energy and clean energy market prices, particularly in the absence of strong clean energy targets. Conversely, ORDCs improve the commitment of available generation units, but this comes at the expense of higher system costs and renewable generation curtailment. We also find that well-calibrated static capacity demand curves can yield similar reliability and total cost compared to capacity market demand curves informed dynamically by resource adequacy while also yielding stable annual capacity prices. Different approaches to formulating ORDC curves can also yield key trade-offs, namely that a more efficient treatment of storage chronology results in lower ORDC curves and prices, yielding less investment and cost but at the expense of reliability. Finally, the effectiveness of wholesale electricity markets in practically achieving very high clean energy generation targets highly depends on the cost-competitiveness of clean energy technologies that can support critical balancing needs across multiple timescales.

capacity expansion↗

EASY-SHIFT v Alpha

The software is a generic, price- and load-responsive control algorithm integrating heat pumps with thermal energy storage. The algorithm leverages simple models of the system and easily accessible data to schedule operation of heat pumps and thermal energy storage in ways that minimize the cost of operating the heating/cooling system. This tool is specifically designed to be easy to interact with, and something that industry partners are able to adopt. There are two current state of the art approaches. Industry tends to develop very simple algorithms, with predetermined schedules that are not capable of changing operation in response to changes in operating environment. For example, a control designed to avoid high-price electricity from 5-8 PM will not be able to adapt if the high-price period changes to 4-9 PM. Academia commonly develops algorithms called Model predictive control (MPC). MPC requires extensive data and highly trained staff to develop a specific type of simulation model of the building, connect the building to optimization algorithms, and leverage powerful computers. Industry, with limited time/finance budgets for any project, is resistant to adopting MPC due to the associated high complexity and cost.

Grant, Peter [Lawrence Berkeley National Laborator↗

Enabling Secure and Resilient XFC: A Software/Hardware-Security Co-Design Approach

Extremely fast charging (XFC) has the potential to reduce the charging time of battery electric vehicles (BEV) to be equivalent to the filling time of internal combustion engine vehicles (ICEV), thus eliminating one of the few advantages ICEV still poses for light- and heavy-duty vehicles. Enabling XFC will, however, require coordination and cooperation between the grid, charging stations, and the vehicles themselves, which leads to an inevitable increase in the attack surface for all systems combined. In securing the overall system, we must not only embrace traditional cybersecurity, which is chiefly concerned with communications and the operation of digital systems, but also cyber-physical systems security as the proper operation of XFC is critically dependent on systems’ abilities to know about (sense) and interact with (actuate) the physical world. The project team consists of academic and industry researchers with backgrounds in cybersecurity, cyber-physical systems security, learning in adversarial environments, transportation security, grid security and resilience, wireless power transfer, converter design, and battery management systems.

33 ADVANCED PROPULSION SYSTEMS↗

Wholesale Electricity Market Design to Support Resource Adequacy

Wholesale electricity markets are intended to incentivize system generation investments and operations outcomes that meet evolving system needs. In this work, we evaluate the effectiveness of wholesale market structures, rules and policies in achieving system resource adequacy (RA) and clean energy targets in the presence of self-interested generation investors using the Electricity Markets and Investment Suite Agent-based Simulation (EMIS-AS) model. Results highlight that both capacity markets and operating reserve demand curves (ORDCs) can help achieve a reliable system but with different RA compliance timelines and distribution of generation technologies. Structures with capacity markets tend to favor more capital-intensive peaking technologies while reducing wind and solar build-outs due to suppressed energy and clean energy market prices, particularly in the absence of strong clean energy targets. Conversely, ORDCs improve the commitment of available generation units, but this comes at the expense of higher system costs and renewable generation curtailment. We also find that well-calibrated static capacity demand curves can yield similar reliability and total cost compared to capacity market demand curves informed dynamically by resource adequacy while also yielding stable annual capacity prices. Different approaches to formulating ORDC curves can also yield key trade-offs, namely that a more efficient treatment of storage chronology results in lower ORDC curves and prices, yielding less investment and cost but at the expense of reliability. Finally, the effectiveness of wholesale electricity markets in practically achieving very high clean energy generation targets highly depends on the cost-competitiveness of clean energy technologies that can support critical balancing needs across multiple timescales.

agent based modeling↗

Development of a robust damage analysis scheme at the National Ignition Facility

The onset of laser-induced damage in optical materials is a limiting factor in the design and operation of most high-energy laser systems. As such, significant effort has been dedicated to developing laser damage testing protocols and procedures to inform laser system design and operating limits. These tests typically rely on multiple laser exposures for statistical validation. Historically, small beam single fluence (N / 1) or ramped fluence (R / 1) tests have been used to quantify the “laser-induced damage threshold” of a material. However, due to various distributions in damage precursor populations, the laser fluence at which damage occurs for a given sample varies with beam size and is therefore better described as the onset of observed damage for that testing geometry. In conclusion, we document the development of irradiation, measurement, and analysis methods for damage testing resulting in damage initiation density as a function of incident fluence or ρ(ϕ) which is suitable for both small and large beam area testing and more conducive to extrapolating from one to the other.

Beam diameter↗

Graph-Learning-Assisted State and Event Tracking for Solar-Penetrated Power Grids with Heterogeneous Data Sources

Unlike transmission systems, distribution systems do not typically contain sufficient metering to enable real-time state estimation. The lack of sufficient real-time measurements prohibits accurate and timely monitoring of the state of distribution systems. As a result, control and optimal operation of distribution systems, especially those containing large numbers of renewable generation units are not possible without proper data and information about the current state of the system. The main motivation of this project is to address this shortcoming by developing an approach which provides “predicted” real-time measurements so that they can be used to execute a distribution system state estimator. Thus, the objective of the project is to make the distribution systems fully observable, such that the hosting capacity for solar generation can be accurately estimated, and unnecessary solar curtailments can be avoided. In order to accomplish this goal, the project investigated the use of a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams obtained from AMI meters, SCADA as well as PMU measurements and created synchronous measurement snapshots for the state estimator (SE); and developed a hybrid robust SE which provides not only accurate state estimates but also real-time feedback for the ML model refinement.

14 SOLAR ENERGY↗

Sensor Placement Optimization Study for the Built Environment: Operational Use Cases

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear and radiological incidents. State, local, tribal, and territorial (SLTT) government agencies that implement systems of fixed-position sensors are faced with numerous decisions regarding sensor selection, quantity, and placement. To develop guidance on implementation of radiation detection systems, we simulated the release of radioactive material in an urban environment using a combination of three models: the Weather Research Forecasting (WRF), Quick Urban and Industrial Complex (QUIC), and Monte Carlo N-Particle (MCNP) models. We then evaluated the performance of several hypothetical sensor systems. The small number of simulations we conducted are not sufficient to generate definitive design guidance for radiation sensor systems, but we did identify trends that would be of interest to emergency planners. For a scenario that releases 1000 curies of Cs-137, radiation detectors were needed at 500-meter intervals to have a high likelihood of event detection and to estimate source location and plume detection. We also noted that optimal detector altitude varied with distance to the source. We recommend additional research in this area be conducted to support developing sensor placement guidelines that expand on a range of locations, isotopes, activity levels, and different weather conditions. Original simulation strategies included a range of environments, additional radioisotopes (Am241 and AmBe), and a larger selection of sensor types. These types of expansions would support SLTT guidance on sensor system recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a realtime digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBRonly scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Verification of Grid-Forming Inverter-Based Power Plant Performance for Transmission System Reliability

This report describes some examples of the operation of two grid-forming (GFM) inverter-based photovoltaic-battery hybrid power plants connected to the electric system of the island of Kauai in Hawaii. Both plants are photovoltaic power plants with battery energy storage and are connected to the networked transmission system operated by Kauai Island Utility Cooperative (KIUC), along with several other power plants including an oil-fired plant, diesel generators, small hydroelectric plants, a biofuel plant, and several other photovoltaic plants.

14 SOLAR ENERGY↗

Assembling an Effective Team for Renewable Generation and Storage Projects

On-site renewable generation and storage systems have piqued the interest of facility owners to substantially reduce their energy costs and environmental footprint. Assembling an effective team before the project begins can streamline the implementation of these systems and ensure that the design, installation, and operation of the system are well aligned with the needs of the facility owner. To inform this process, this resource will provide three specific guidelines: Guideline 1: Identify common skillsets in renewable energy and storage projects; Guideline 2: Decide who will fill these skillsets, internally and externally; and Guideline 3: Recognize additional project considerations to ensure cost-effectiveness, increased resiliency, and contribution to both electrification and decarbonization goals.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Real-Time Simulation of Solid Oxide Electrolyzers (SOEC) for Dynamic Operability Improvement and Cyber-Physical System Development

As more intermittent-renewable generations are being added to the power grid, solid oxide electrolysis cells (SOEC) must enhance their rapid load transition capabilities to load follow and support grid resilience. At NETL, we developed real-time SOEC models to research SOEC transients during load step changes. The gained insights can be useful for dynamic operability improvement. These real-time SOEC models also established the basis for cyber-physical SOEC hybrid energy systems. (Virtual presentation to the 2025 MILLENNIUM CLEAN and SUSTAINABLE POWER workshop, University of Genoa, Italy)

20 FOSSIL-FUELED POWER PLANTS↗

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months.

array↗

New helium recapture and reliquefier system for Dynamic Nuclear Polarization at UNH.

A new helium recapture and reliquefaction system, consisting of a gas bag, recapture manifold, cooling chiller, cryogenic purifier and, a gas storage cylinder banks, has been installed in the dynamic nuclear polarized target lab at the University of New Hampshire. This new system has the capability to improve the efficiency of our capacity to do target polarization runs by recycling our cryogenic helium which would otherwise be lost during polarization operations. Our helium liquefier is rated upto 40 L/Day under normal full-capacity operations, and is rated for a capacity of 500 liquid liters of helium. I explain the initial installation process followed by a discussion of the challenges with installation, including issues of impurities which appeared during the initial operation of the system. Then I discuss how we overcame these difficulties. Finally, I discuss the function of the system during normal operation and the present situation of the helium recapture and reliquefaction processing in the UNH Lab.

Lama, Chhetra [Univ. of New Hampshire, Durham, NH ↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months. Index Terms - photovoltaic module, floating PV systems, string, array, temperature, mismatch, utility scale.

ENGINEERING,SOLAR ENERGY↗

From natural language to control signals: a conceptual framework for semantic channel finding in complex experimental infrastructure

Modern experimental platforms such as particle accelerators, fusion devices, telescopes, and industrial process control systems expose tens to hundreds of thousands of control and diagnostic channels, accumulated over decades of hardware evolution. Operators and AI systems alike depend on informal expert knowledge, inconsistent naming conventions, and scattered documentation to locate the signals required for monitoring, troubleshooting, and automated control, creating a persistent bottleneck for reliability, scalability, and emerging language-model-driven interfaces. We formalize semantic channel finding, the task of mapping natural-language intent to concrete control-system signals, as a general problem in complex experimental infrastructure, and introduce a four-paradigm conceptual framework to guide architecture selection based on facility-specific data regimes. The paradigms span (i) direct in-context lookup over small, curated channel dictionaries, (ii) constrained hierarchical navigation through structured trees, (iii) interactive agent exploration using iterative reasoning and tool-based database queries, and (iv) ontology-grounded semantic search that decouples channel meaning from facility-specific naming conventions. We demonstrate the practical feasibility of each paradigm through proof-of-concept implementations at four operational facilities spanning two orders of magnitude in scale: from compact free-electron lasers to large synchrotron light sources, operating under diverse control-system architectures ranging from clean hierarchical naming schemes to legacy environments with decades of heterogeneous conventions. Where evaluated against expert-curated operational queries, these instantiations achieve 90%–97% accuracy, validating the framework’s applicability across real-world deployment scenarios. To accelerate adoption across the broader scientific and industrial control-system community, we release open-source, plug-and-play implementations of all three interactive paradigms-direct lookup, hierarchical navigation, and middle-layer exploration-within the Osprey framework, together with tools for channel database generation, interactive testing, and minimal-configuration deployment. This work establishes semantic channel finding as a foundational capability for human-centric and agentic AI interfaces at large-scale facilities, providing both a systematic framework for architecture design and practical resources to enable adoption without building custom infrastructure from scratch.

channel finding↗