Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Education for PV Modeling Professionals: Observations from the 2025 PVPMC Workshop

We surveyed professionals in the photovoltaic industry to understand interests in education and training for performance modeling of solar power systems. We found that most professionals are self-taught and rely on a variety of public sources of technical materials. Available formal education, such as courses or certification programs, either lacks detail or is focused on software user training. Responses indicate several opportunities to create public resources that would benefit professional learning for solar power system modeling: • Create a glossary of terms and common variable names. • Develop guidance on uncertainty analysis in the context of solar power systems modeling. • Assemble a catalog of available educational materials and data sources.

14 SOLAR ENERGY↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Impacts of Short-Term Solar Power Forecasts in System Operations

Solar generation is experiencing an exponential growth in power systems worldwide and, along with wind power, is posing new challenges to power system operations. Those challenges are characterized by an increase of system variability and uncertainty across many time scales: from days, down to hours, minutes, and seconds. Much of the research in the area has focused on the effect of solar forecasting across hours or days. This paper presents a methodology to capture the effect of short-term forecasting strategies and analyzes the economic and reliability implications of utilizing a simple, yet effective forecasting method for solar PV in intra-day operations.

14 SOLAR ENERGY↗

Bed-rest studies: Fluid and electrolyte responses

Confinement in the horizontal position for 2 to 3 weeks results in a chronic decrease in plasma volume, increased interstitial fluid volume, and unchanged or slightly increased extracellular fluid volume. Concentrations of blood electrolytes, glucose, and nitrogenous constituents remain within normal limits of variability when maintenance levels of isometric or isotonic exercise are performed for 1 hr/day. Hematocrit and plasma osmolality can be elevated significantly throughout bed rest (BR). Significant diuresis occurs on the first day, and increases in urine Na and Ca continue throughout BR, although voluntary fluid intake is unchanged. Urine Na and K are evaluated during the second week of BR in spite of stabilization of PV and extracellular volume. The initial diuresis probably arises from the extracellular fluid while subsequent urine loss above control levels must come from the intracellular fluid. Preservation of the extracellular volume takes precedance over maintenance of the intracellular fluid volume. The functioning of a natriuretic factor (hormone) to account for the continued increased loss of Na in the urine is suggested.

Greenleaf, J. E.↗

Bed-rest studies - Fluid and electrolyte responses

Confinement in the horizontal position for 2 to 3 weeks results in a chronic decrease in plasma volume, increased interstitial fluid volume, and unchanged or slightly increased extracellular fluid volume. Concentrations of blood electrolytes, glucose, and nitrogenous constituents remain within normal limits of variability when maintenance levels of isometric or isotonic exercise are performed for 1 hr/day. Hematocrit and plasma osmolality can be elevated significantly throughout bed rest (BR). Significant diuresis occurs on the first day, and increases in urine Na and Ca continue throughout BR, although voluntary fluid intake is unchanged. Urine Na and K are evaluated during the second week of BR in spite of stabilization of PV and extracellular volume. The initial diuresis probably arises from extracellular fluid while subsequent urine loss above control levels must come from the intracellular fluid. Preservation of the extracellular volume takes precedance over maintenance of the intracellular fluid volume. The functioning of a natriuretic factor (hormone) to account for the continued increased loss of Na in the urine is suggested. Previously announced in STAR as N83-24160

Greenleaf, J. E.↗

Equation-based languages – A new paradigm for building energy modeling, simulation and optimization

Most of the state-of-the-art building simulation programs implement models in imperative programming languages. This complicates modeling and excludes the use of certain efficient methods for simulation and optimization. In contrast, equation-based modeling languages declare relations among variables, thereby allowing the use of computer algebra to enable much simpler schematic modeling and to generate efficient code for simulation and optimization. We contrast the two approaches in this paper. We explain how such manipulations support new use cases. In the first of two examples, we couple models of the electrical grid, multiple buildings, HVAC systems and controllers to test a controller that adjusts building room temperatures and PV inverter reactive power to maintain power quality. In the second example, we contrast the computing time for solving an optimal control problem for a room-level model predictive controller with and without symbolic manipulations. As a result, exploiting the equation-based language led to 2, 200 times faster solution

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning reduces soft costs for residential solar photovoltaics

Further deployment of rooftop solar photovoltaics (PV) hinges on the reduction of soft (non-hardware) costs—now larger and more resistant to reductions than hardware costs. The largest portion of these soft costs is the expenses solar companies incur to acquire new customers. In this study, we demonstrate the value of a shift from significance-based methodologies to prediction-oriented models to better identify PV adopters and reduce soft costs. We employ machine learning to predict PV adopters and non-adopters, and compare its prediction performance with logistic regression, the dominant significance-based method in technology adoption studies. Our results show that machine learning substantially enhances adoption prediction performance: The true positive rate of predicting adopters increased from 66 to 87%, and the true negative rate of predicting non-adopters increased from 75 to 88%. We attribute the enhanced performance to complex variable interactions and nonlinear effects incorporated by machine learning. With more accurate predictions, machine learning is able to reduce customer acquisition costs by 15% ($0.07/Watt) and identify new market opportunities for solar companies to expand and diversify their customer bases. Our research methods and findings provide broader implications for the adoption of similar clean energy technologies and related policy challenges such as market growth and energy inequality.

14 SOLAR ENERGY↗

Redesigning Photoelectrodes So They Can Work in the Light and Dark

Unassisted photoelectrochemical (PEC) reactions, such as H2 generation and CO2 reduction, are limited by the durability of the immersed photoelectrode. Small band gap semiconductors, like Si, are efficient at utilizing a large portion of the solar spectrum but are not stable in aqueous environments without protection. While great strides have been made to improve stability under constant illumination, dark stability remains relatively unexamined and presents great challenges for durable PEC systems. Cathodic protection is an established electrochemical method for preventing metal electrode degradation in harsh conditions. Similar protection strategies cannot be applied to traditional two-terminal (2T) semiconductor photoelectrodes because of their inability to pass reverse bias current in the dark. New, three-terminal (3T) photovoltaic (PV) architectures introduce additional degrees of freedom in traditional 2T PEC operations by adding an extra electrical contact for an alternative low resistance path to protect the photoelectrode and drive electrochemical reactions, even in the dark. Here, we investigate bare 3T Si PV devices operating as photocathodes in aqueous methyl viologen electrolyte. The 3T architecture provides additional capabilities to PEC systems such as cathodic protection, the ability to drive reactions with or without illumination, and in situ switching between different operational modes. We show that 3T-based Si photocathodes maintain PEC activity after several hours of light/dark cycling. This work helps advance PEC use in real-world conditions where variable illumination must be considered.

cathodic protection↗

Value Proposition of UV-Absorbers in PV Module Encapsulation

Various common crystalline silicon cell technologies were exposed to UVA radiation (1.24 Wm-2 nm-1 at 340 nm peak) on the front and back faces at 45 degrees Celsius for periods up to 3000 h, representing about 3 y of solar exposure in Phoenix, Arizona, USA. The resulting degradation of the open-circuit voltage and short-circuit current is presented. Of the various cell types examined, significant levels of degradation were seen in all cases. Less degradation was generally found after UV irradiation of cell fronts and older cell types, whereas a bifacial PERC type exposed on the rear showed about 25% degradation in short circuit current, attributable to lack of a diffused surface field. Selected cells were exposed to UV irradiation with the addition of long pass UV filters to replicate UV-absorbers in encapsulants. Modern cell designs are sensitive to UV-ID because of reduced or eliminated front and back surface field and increased dependence on high quality surface passivation. Single transformation of the independent variable (t, kW h/m^2) could be used to achieve a linear model of the data to extrapolate to 50 y. Solar Advisor Model (SAM) shows appropriate filtering of UV-irradiation can improve LCOE and net present value of plant. Some advanced cell types are seen to be UV-resistant (cell level solutions also exist). Solutions therefore exist on the cell, glass, and encapsulant level. Changes over time in each of these would also need to be considered (solarization, encapsulant browning...).

ENGINEERING,SOLAR ENERGY↗

Advancing Concentrating Solar Thermal Modeling Using System Advisor Model (SAM)

Concentrating solar thermal (CST) technologies play a critical role in enabling dispatchable power and high-temperature industrial heat applications. Accurate and flexible modeling tools are essential for evaluating system performance, guiding technology research and development, and informing investment decisions. The National Laboratory of the Rockies's System Advisor Model (SAM) is a widely used techno-economic simulation platform for CST systems, providing detailed performance and financial modeling capabilities for multiple CST system configurations. SAM integrates physics-based performance models with financial analysis to simulate the behavior of complex energy systems under realistic operating conditions. For CST technologies (including tower, parabolic trough, and linear Fresnel), SAM enables hourly simulations using site-specific weather data that ensure feasible operating conditions and convergence of mass and energy between core system components (i.e., solar field, receiver, thermal energy storage, and power cycle). These capabilities allow researchers and developers to evaluate annual energy production, capacity factors, levelized cost of energy (LCOE), and system dispatch strategies. A key advantage of SAM lies in its flexibility for parametric analysis and large-scale computational studies. Users can vary system design parameters such as heliostat field layout, receiver dimensions, thermal energy storage capacity, power block sizing, and installation cost assumptions to investigate their impact on system performance and financial metrics. When combined with automated scripting through LK, SDKTool, or Python interfaces, SAM enables high-throughput simulation workflows that support sensitivity analysis, technology benchmarking, and optimization studies. These approaches are particularly valuable for next-generation CST concepts, where design spaces are large and system interactions are complex. Another important capability of SAM is its support for dispatch optimization and thermal energy storage modeling, which are central to the value proposition of CST technologies. The ability to simulate integrated storage and flexible power generation allows researchers to explore strategies that maximize grid value, improve capacity utilization, and enhance integration with variable resources such as photovoltaic and wind generation. This poster will present an overview of SAM's thermal system modeling capabilities including concentrating solar. Additionally, we will highlight new feature developments including: 1) implementing Google's OR-Tools optimization platform for faster and more robust dispatch optimization, 2) developing a new power load following controller for modeling behind-the-meter applications, 3) enabling direct modeling of CSP-PV hybrid systems with the inclusion of battery storage, and 4) developing a multi-receiver falling particle Gen3 system model.

14 SOLAR ENERGY↗

Low Cost (CAPEX and variable): Tool design for cell and module fabrication with thin, free-standing silicon wafers

This project aimed to develop technologies that can potentially enable free-standing thin (<80 μm) wafer in today’s manufacturing lines with high production yield, and thereby reduce capex barriers of silicon photovoltaics cells and modules. One of the major benefits is that thin wafer dramatically reduces the amount of polysilicon required. As a result, it can lead to reduction in the capital expenditures associated with polysilicon refining and wafer fabrication, which together are more than half of the total capital expenditure to manufacture Si PV module. We focused our efforts on developing the tools needed to enable high yield fabrication of wafer, cell, and module with thin silicon wafers. However, as the wafer thickness reduces, the major challenge is that wafer breakage increases significantly. Three technological areas were explored in this project to improve the production yield of the silicon wafer, namely detection of edge cracks via dark-field near-infrared (NIR) scattering; (2) wafer handling using controlled temperature profiles; (3) manufacturable low-stress cell interconnection for multiwire. First, the formation of wafer cracks in submillimeter length is one of the reasons that causes wafer breakages. Crack detection tools are needed to enable us to locate and track the wafer crack during manufacturing, so that we can improve the process to reduce initialization. The state-of-the-art crack detection technique cannot fulfill the need for measuring submillimeter edge cracks detrimental for thin wafers. The prototype developed in this project demonstrates the scanning of microcracks near wafer edges. With a semi-automatic laboratory setup, the submillimeter cracks were reliably detected near the edges in multi-Si wafers. The smallest detectable crack is 200 µm in length in slow scans; and submillimeter cracks are detected in high-throughput scans at the scan speed of >0.5 m/s, which is compatible with the inline detection of a manufacturing line at least 1 sec/wafer. This detection limit is a significant advancement in comparison to the benchmarked industrial tool. Second, wafer handling with the well-controlled temperature profile was thought to be the solution to reduce crack initiation and propagation during the manufacturing. However, without crack detection being widely adopted in production line, we did not find a strong industrial pull toward this technology. We did an initial literature survey and then diverted our efforts to the other tasks. Third, the innovation on low-stress multi-wire interconnection tackles a fundamental problem in the standard interconnection scheme. The standard over-under “zig-zag” interconnection induces a significant amount of stress into the soldering point on the cell whenever PV module is under stress, e.g., thermal cycling, transportation, and installation. Therefore, the interconnection process was re-designed in this project to allow for significant movement between adjacent solar cells, e.g., due to thermal expansion, without building up stresses on the solar cells or solder joints. The new interconnection method with the cross-connect wire also simplifies the tabbing and stringing process by replacing the standard over-under method with an off-cell interconnect from top to bottom. A manual tabbing and stringing tool for this new process was prototyped in the lab to demonstrate the fabrication of this new interconnection design. During the test with brass sheets as our “testing cells”, it was found that the mechanical cycling test only broke the interconnection after more than 50,000 cycles, which is equivalent to more than 130 years of the day-and-night thermal cycles. Lastly, throughout the project, we continuously analyzed the PV market with techno-economic analysis to identify the opportunity for thin Si adoption. Even though the drastic cost reduction has already happened in the past five years, our analysis results indicated that we can still save quite significantly in both manufacturing cost and factory capex, Particularly, in order to grow the PV manufacturing capacity to multi-terawatt level, reducing the thickness of silicon wafer is one of the most effective ways to quickly reduce factory capex, and sustain the high growth rate. The technologies developed in this project are readily available to provide some assistances in tackling the production yield problem.

14 SOLAR ENERGY↗

Amorphous metallic films in silicon metallization systems

Diffusion barrier research was focussed on lowering the chemical reactivity of amorphous thin films on silicon. An additional area of concern is the reaction with metal overlays such as aluminum, silver, and gold. Gold was included to allow for technology transfer to gallium arsenide PV cells. Amorphous tungsten nitride films have shown much promise. Stability to annealing temperatures of 700, 800, and 550 C were achieved for overlays of silver, gold, and aluminum, respectively. The lower results for aluminum were not surprising because there is an eutectic that can form at a lower temperature. It seems that titanium and zirconium will remove the nitrogen from a tungsten nitride amorphous film and render it unstable. Other variables of research interest were substrate bias and base pressure during sputtering.

So, F.↗

Employing Fracture Statistics to Track Cell Reliability Through Module Fabrication

In this work we demonstrate how fracture statistics may be employed to track cell reliability through module fabrication steps. We were able to detect how cell cutting equipment could reduce cell fracture strain by 25 % as well as increase its variability. A smaller reduction was found to result from the ribbon soldering operation, and all cells measured were weaker when strained in an orientation perpendicular to the gridlines. Cell fracture measurements were found to be consistent with the number of cracked cells experienced in full sized modules exposed to mechanical loading. A structural mechanics model was created to elucidate how the requisite fracture strain is developed in a cell encapsulated within a PV module and demonstrates that this strain decreases more than 50 % from its center to edge when placed within the inner loading span of four-point flexure. The associated implications on the apparent cell strength is examined with an effective volume treatment.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Mitigating Phase Unbalance for Distribution Systems with High Penetrations of Solar PV (Final Technical Report)

Distribution system operators have traditionally limited unbalance among phases by maintaining similar loadings on each phase. High penetrations of distributed solar PV continually change the net loading on each phase, resulting in time-varying phase unbalances that can damage three-phase devices such as three-phase motors, violate grid codes, and increase technical losses. This project has developed several control strategies for the reactive power outputs of solar PV inverters in order to mitigate power quality issues related to phase unbalance. These control strategies include a decentralized approach that is solely based on local measurements, distributed and grouped approaches that consider subsets of loads and PV generators, and a centralized approach that leverages measurements from a variety of locations in order to compute optimal reactive power setpoints for each inverter. Variants of the controllers handle challenges relevant to practical implementations, including noisy measurements, delayed communications, and reactive power limits. Moreover, the project developed theory that provides convergence guarantees for systems with multiple interacting controllers as well as “balanceability” certificates that ensure satisfaction of phase unbalance requirements with variable loading. The controllers were integrated with NRECA’s Open Modeling Framework (omf.coop) and evaluated using actual distribution system models obtained from several NRECA member utilities. Application of the controllers results in significant improvements to phase unbalance in these test cases with decreases from base case levels of over 3% to under 0.5%, which is within the 2% IEC phase unbalance standard.

14 SOLAR ENERGY↗

Employing Fracture Statistics to Track Cell Reliability Through Module Fabrication

In this work we demonstrate how fracture statistics may be employed to track cell reliability through module fabrication steps. We were able to detect how cell cutting equipment could reduce cell fracture strain by 25 % as well as increase its variability. A smaller reduction was found to result from the ribbon soldering operation, and all cells measured were weaker when strained in an orientation perpendicular to the gridlines. Cell fracture measurements were found to be consistent with the number of cracked cells experienced in full sized modules exposed to mechanical loading. A structural mechanics model was created to elucidate how the requisite fracture strain is developed in a cell encapsulated within a PV module and demonstrates that this strain decreases more than 50 % from its center to edge when placed within the inner loading span of four-point flexure. The associated implications on the apparent cell strength is examined with an effective volume treatment.

14 SOLAR ENERGY↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

Advanced Signal Decomposition Analysis and Anomaly Detection in Photovoltaic Systems

With the rapid expansion of large-scale photovoltaic (PV) plants, it is paramount for solar stakeholders to understand the reliability and efficiency of their plants to inform maintenance decisions, increase production, and understand the design factors that impact performance. Diagnosing underperformance in PV plants is challenging due to the relatively few monitoring points with respect to the large geographic footprint of the plant. This work introduces a cutting-edge method that transforms the analysis and management of key factors influencing PV plant performance, including performance loss rate (PLR), recoverable soiling, and major system changes. Identifying these factors is critical for deriving actionable insights. Leveraging advanced analytical techniques such as wavelet transformation, robust regression, and extreme point analysis, this approach provides a nuanced understanding of these factors. This method has been tested across two synthetic datasets and one real dataset, consistently surpassing existing benchmarks by achieving a lower median mean absolute error and reduced error variability across all comparable components.

14 SOLAR ENERGY↗