BraggNN : fast X-ray Bragg peak analysis using deep learning

X-ray diffraction based microscopy techniques such as high-energy diffraction microscopy (HEDM) rely on knowledge of the position of diffraction peaks with high precision. These positions are typically computed by fitting the observed intensities in detector data to a theoretical peak shape such as pseudo-Voigt. As experiments become more complex and detector technologies evolve, the computational cost of such peak-shape fitting becomes the biggest hurdle to the rapid analysis required for real-time feedback in experiments. To this end, we propose BraggNN, a deep-learning based method that can determine peak positions much more rapidly than conventional pseudo-Voigt peak fitting. When applied to a test dataset, peak center-of-mass positions obtained from BraggNN deviate less than 0.29 and 0.57 pixels for 75 and 95% of the peaks, respectively, from positions obtained using conventional pseudo-Voigt fitting (Euclidean distance). When applied to a real experimental dataset and using grain positions from near-field HEDM reconstruction as ground-truth, grain positions using BraggNN result in 15% smaller errors compared with those calculated using pseudo-Voigt. Recent advances in deep-learning method implementations and special-purpose model inference accelerators allow BraggNN to deliver enormous performance improvements relative to the conventional method, running, for example, more than 200 times faster on a consumer-class GPU card with out-of-the-box software.

36 MATERIALS SCIENCE↗

Massive compression for high data rate macromolecular crystallography (HDRMX): impact on diffraction data and subsequent structural analysis

New higher-count-rate, integrating, large-area X-ray detectors with framing rates as high as 17400 images per second are beginning to be available. These will soon be used for specialized macromolecular crystallography experiments but will require optimal lossy compression algorithms to enable systems to keep up with data throughput. Some information may be lost. Can we minimize this loss with acceptable impact on structural information? To explore this question, we have considered several approaches: summing short sequences of images, binning to create the effect of larger pixels, use of JPEG-2000 lossy wavelet-based compression, and use of Hcompress, which is a Haar-wavelet-based lossy compression borrowed from astronomy. We also explore the effect of the combination of summing, binning, and Hcompress or JPEG-2000. In each of these last two methods one can specify approximately how much one wants the result to be compressed from the starting file size. These provide particularly effective lossy compressions that retain essential information for structure solution from Bragg reflections.

47 OTHER INSTRUMENTATION↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

An Analysis of Input Parameters for Film-Based Flash X-Ray Radiography

Flash X-ray radiography (flash) is a commonly used diagnostic technique in dynamic experiments. An analysis of the effects of input parameters on resulting metrics of image quality can aid the experimentalist in configuring the X-ray input parameters to produce the highest quality radiograph for a given experiment. Here, a flash X-ray test bed with HS800 film and a LANEX Medium F intensifier screen was used with an L3 450 kVp pulser and Scandiflash X-ray tube for this study. Input parameters including charge voltage, source filtering, and film-pack assembly were investigated for their impact on contrast-to-noise ratio (CNR), contrast, and contrast transfer function (CTF). Using VIDAR’s NDT Pro industrial film digitizer, scanner parameters such as optical density range, pixel spacing, scan mode, and digital bit-depth were also examined for their impact on image quality metrics. The highest CNR values were found with two LANEX intensifiers and no filtering. Charge voltage had no direct impact on CNR values. LANEX screen count and filtering resulted both in direct effects on CNR and interaction effects with each other and CNR value. Uncertainty bounds for CNR comparisons and repeatability of CTF evaluations are also discussed. Finally, the film results are compared with a previous study using other detector types, specifically Carestream INDUSTREX Flex GP, Flex HR, Flex XL Blue, and HPX-DR 3543.

dynamic radiography↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $\mu$m pixel, fully-depleted, p-channel devices that have been thinned to ~250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., single-sample readout noise < 4.3 e- rms/pixel, the ability to achieve multi-sample readout noise $\ll$ 1 e- rms/pixel, full-well capacities ~40,000-65,000 e-, low dark current and charge transfer inefficiency (~2 x 10$^{-4}$ e-/pixel/s and 3.44 x 10$^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim$ 80% between 450 nm and 980 nm ($\gtrsim$ 90% between 600 nm and 900 nm). We optimized the readout sequence timing to achieve sub-electron noise (~0.5 e- rms/pixel) in a region of 2k x 4k pixels and photon-counting noise (~0.22 e- rms/pixel) in a region of 220 x 4k pixels, each with a readout time of $\lesssim$ 17 min. We observed two quasars (HB89 1159+123 and QSO J1621-0042) at redshift z ~ 3.5, two high-redshift galaxy clusters (CL J1001+0220 and SPT-CL J2040-4451), an emission line galaxy at z = 0.3239, a candidate member star of the Bo\"{o}tes II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observations of the quasar HB89 1159+123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvements for SIFS observations in the low-background, readout-noise-dominated regime. We outline scientific studies that will leverage the SIFS-Skipper CCD data and new detector architectures that utilize the Skipper floating gate amplifier with faster readout times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source noise suppression in attosecond transient absorption spectroscopy by edge-pixel referencing

Attosecond transient absorption spectroscopy (ATAS) is used to observe photoexcited dynamics with outstanding time resolution. The main experimental challenge of this technique is that high-harmonic generation sources show significant instabilities, resulting in sub-par sensitivity when compared to other techniques. This paper proposes edge-pixel referencing as a means to suppress this noise. Two approaches are introduced: the first is deterministic and uses a correlation analysis, while the second relies on singular value decomposition. Each method is demonstrated and quantified on a noisy measurement taken on WS 2 and results in a fivefold increase in sensitivity. The combination of the two methods ensures the fidelity of the procedure and can be implemented on live data collection but also on existing datasets. The results show that edge-referencing methods bring the sensitivity of ATAS near the detector noise floor. An implementation of the post-processing code is provided to the reader.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗

Progress on Associated-Particle Imaging Algorithms, 2022

The present work describes progress on developing imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating among critical materials or extracting three-dimensional (3D) geometrical information from single-sided or transmission measurements. The present work is divided into three approaches: 1.Iterative reconstruction of inelastic gamma-ray emissions to perform 3D time-of-flight (TOF) imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution. 2.Decomposition of registered neutron and x-ray radiographs into an assumed material list for each pixel in the image. 3.Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles. Progress for each approach is summarized for fiscal year (FY) 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Progress on Associate-Particle Imaging Algorithms, 2020

The present work describes progress on the development of imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating between critical materials or extracting three-dimensional geometrical information from single-sided or transmission measurements. The present work is divided into three approaches:(1)Iterative reconstruction of inelastic gamma-ray emissions to perform three-dimensional time-of-flight imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution.(2)Decomposition of registered neutron and x ray radiographs into an assumed material list for each pixel in the image.(3)Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles.Progress for each approach is summarized for fiscal year 2020.

97 MATHEMATICS AND COMPUTING↗

The beam test of the lead tungstate calorimeter prototype with SiPM readout at Jefferson Lab

The lead tungstate crystals (PWO4) are a well-known radiator material for precise homogeneous electromagnetic calorimetry. In nuclear physics experiments, the typical way to read out the crystals is using conventional photomultiplier tubes (PMTs). In the case of the presence of a magnetic field, such a method has some complications and requires a passive PMT shielding design. The recent development of Silicon Photomultipliers (SiPMs) with small pixel pitch sizes and relatively small noise levels opens an opportunity avenue to use such a device as an alternative to conventional PMTs. The SiPM readout method may be beneficial for future nuclear physics and collider experiments. We are presenting the beam test results of the calorimeter prototype instrumented with SiPM readout performed at Jefferson Lab. The SiPM readout performance was compared with PMT readout measured at the same experimental conditions. The prototype was successfully tested using beam of photons in the energy range between 3 GeV and 11 GeV in experimental Hall D. The detector performance was also studied using a secondary beam of positrons provided by Hall D pair spectrometer.

Berdnikov, Vladimir↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Time-walk and jitter correction in SNSPDs at high count rates

Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗