Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the Atmosphere Explorer, hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested at NASA to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Atmosphere Explorer spacecraft (AE's C, D, and E). The diaphragms will be used for positive propellant expulsion and spacecraft center of mass (c.m.) control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 10 psid during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft c.m. control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

Electromagnetic position sensor for a magnetically supported model in a wind tunnel

An investigation was undertaken to determine the feasibility of using superconducting force-producing coils for positioning a model in a wind tunnel. The cryostat containing the forcing coils surrounded the test section of the tunnel, thus favoring an electromagnetic position sensor. Another reason favoring this choice was the fact that the performance of an electromagnetic sensor is essentially unaffected by the shape of the model.

Towler, W. R.↗

Temporal variations in the dawn and dusk midlatitude trough position-modeled and measured (Ariel 3)

The temporal development of the latitudinal position of the 600 km midlatitude electron density trough at dawn and dusk during the period 25-27 May 1967, which encompassed a large magnetic storm, was measured by the RF capacitive probe on the polar orbiting Ariel 3 satellite. The substorm-related changes in the L coordinate of the trough minimum and the point of most rapid change of density gradient on the low latitude side of the trough are similar. Oscillations of the trough position at dusk are in phase with substorm activity whereas movement of the trough at dawn is only apparent with the onset of the large storm. Near dusk there is evidence of structure in the form of a tail-like extension of the plasmasphere at the peak of the storm. Detailed model calculations assuming a spatially invariant equatorial convection E field which varies in step with K sub p index reproduces much of the observed behavior, particularly at dusk, and shows that more than one plasmapause-type transition may be identifiable in the trough region.

Grebowsky, J. M.↗

Si(Li) position sensitive detector

A position sensitive detector was made using the lithium diffused layer of a lithium-drifted-silicon detector as the uniform resistive layer. An expression is derived for estimating the resistance from the thickness of the lithium layer. Expressions for the noise and ballistic deficit for single differentiation-double integration pulse shaping are presented. Room temperature data for a 1 Mev proton beam on a 45 mm long detector shows that the linearity is better than .05% and that the position resolution is 1.06 + or - .05 mm.

Gigante, J. R.↗

Pole position studied with artificial earth satellites.

Long-arc orbit computation of highest accuracy can provide pole positions. Optical Baker-Nunn and laser range observations of several satellites are combined. The accuracy of the pole position is comparable to that of the mean satellite-tracking station coordinates (plus or minus 5 m) when sufficient tracking data are available. Exploitation of the technique requires more accurate tracking data.

Gaposchkin, E. M.↗

X-ray pulse profile and celestial position of Hercules X-1.

The celestial position of the binary X-ray source Her X-1 has been measured with a precision of 30 sec and, within the uncertainties, agrees with the position of the optical variable HZ Herculis. An average light curve for the 1.24-sec periodicity has been obtained with about 10-msec resolution. The average pulse is a double-peaked structure which shows significant intensity changes in time scales down to 30 msec.

Doxsey, R.↗

Corrections of satellite positions in near-real time.

The influence of sudden increases of electron content on the accurate determination of the position of a satellite is investigated based on a spherically stratified ionospheric model. Using the total electron content information from Faraday rotation measurements, a procedure is presented whereby the corrections of satellite position due to the unpredicted electron increase can be accounted for without the need to know the spatial distribution of the additional electrons.

Poularikas, A. D.↗

Excitation of the CO fourth positive system by the dissociative recombination of CO2/+/ ions.

The fourth positive system of CO has been excited in a static afterglow experiment by the dissociative recombination of CO2(+) ions. From combined absolute optical and microwave measurements the specific recombination coefficient for exciting the CO system was found to be (2 plus 1 or minus 0.5) x 10 to the minus 8th cu cm/sec. This value represents approximately 5% of the total recombination coefficient (4.0 plus or minus 0.5) x 10 to the minus 7th cu cm/sec measured in this experiment, implying that CO2(+) dissociative recombination will contribute significantly to the excitation of the CO fourth positive system in the Martian airglow. Corroborative electron heating experiments showed that the magnitude of the specific recombination coefficient decreased as the electron temperature was increased. Evidence was also found for the presence of vibrationally excited ions in the CO2(+) plasma, a result which indicates that analogous laboratory studies on the dissociative recombination of O2(+), N2(+), and NO(+) ions may have also involved vibrationally hot plasmas.

Gutcheck, R. A.↗

En route position and time control of aircraft using Kalman filtering of radio aid data

Fixed-time-of-arrival (FTA) guidance and navigation is investigated as a possible technique capable of operation within much more stringent en route separation standards and offering significant advantages in safety, higher traffic densities, and improved scheduling reliability, both en route and in the terminal areas. This study investigated the application of FTA guidance previously used in spacecraft guidance. These FTA guidance techniques have been modified and are employed to compute the velocity corrections necessary to return an aircraft to a specified great-circle reference path in order to exercise en route time and position control throughout the entire flight. The necessary position and velocity estimates to accomplish this task are provided by Kalman filtering of data from Loran-C, VORTAC/TACAN, Doppler radar, radio or barometric altitude,and altitude rate. The guidance and navigation system was evaluated using a digital simulation of the cruise phase of supersonic and subsonic flights between San Francisco and New York City, and between New York City and London.

Mcgee, L. A.↗

An experimental evaluation of metallic diaphragms for positive fuel expulsion in the atmosphere explorer hydrazine propulsion subsystem

Four Arde conospheroid metallic diaphragms were tested to evaluate their capability for use in the orbit adjust propulsion subsystem (OAPS) of the Explorer spacecraft. The diaphragms will be used for positive propellant expulsion and spacecraft center of mass control. A leak-free cycle life capability of nine reversals was demonstrated. The diaphragms rolled smoothly from ring to ring in a predictable manner on the first reversal. Varying amounts of diaphragm cocking and ring skipping were observed on subsequent reversals. The diaphragm pressure differential did not exceed 7 N/sq cm during any reversal. Cycle life capability, reversal mode, and pressure differential were not affected by sudden reversals, environmental tests, or 18,000 partial reversals. An expulsion efficiency of approximately 97 percent was demonstrated. The results of these tests show that metallic diaphragms can be used as an effective means of positive fuel expulsion; however, to achieve spacecraft center of mass control, the diaphragm must not be reversed prior to flight.

Woodruff, W. L.↗

A high resolution study in time, position, intensity, and frequency of a radio event on 14 January 1971

High resolution position and spectrum measurements were made of a complex solar radio activity on January 14, 1971, from 1120 to 1130 UT. Positions were measured with 169 MHz Nancay E-W Radioheliograph, while dynamic spectra and polarization were observed with the 60-channel radiospectrograph of Nera. The radio event consisted of two closely similar groups of type 3 bursts and type 2-like details, and a stationary type 4 continuum, including some very clear pulsating structures. The general aspect of this activity is presented.

Caroubalos, C.↗

Two-position dc pulse voltage stabilizer

The advantages of the dc pulse voltage stabilizers over the continuous action stabilizers are described. These advantages include higher efficiency, low sensitivity to the ambient temperature and insignificant size and weight. A comparison is made between the schematics of the known two position pulse stabilizer with a Schmitt trigger and that developed by the author. A characteristic feature of the improved system is the increased stabilization coefficient and the possibility of smooth regulation of the output voltage. A practical schematic is presented for the improved two position pulse stabilizer along with its parameters.

Osadchiy, V. I.↗

Effects of an anti-G suit on the hemodynamic and renal responses to positive /+Gz/ acceleration

The effects of the currently used U.S. Air Force (CSU-12/P) anti-G suit on renal function during positive radial acceleration (+Gz) were assessed in seven normal male subjects in balance on a 200 meq sodium diet. Following suit inflation in the seated position, +2.0 Gz for 30 min resulted in a decrease in the rate of sodium excretion from 125 plus or minus 19 to 60 plus or minus 14 microeq/min, which persisted during a 25-min recovery period. Fractional excretion of sodium also decreased significantly during +Gz. The magnitude of the antinatriuresis was indistinguishable from that observed during +Gz without suit inflation. In contrast to the antinatriuresis observed during centrifugation without suit, however, the antinatriuresis with suit was mediated primarily by an enhanced tubular reabsorption of sodium.

Shubrooks, S. J., Jr.↗

Temporal variations in the dawn and dusk midlatitude trough and plasmapause position

The temporal development of the latitudinal position of a 600-km midlatitude electron density trough at dawn and dusk during the period 25-27 May 1967, which encompassed a large magnetic storm, was measured by the RF capacitive probe on the polar orbiting Ariel 3 satellite. The substorm-related changes in the L coordinate of the trough minimum and the point of most rapid change of density gradient on the low latitude side of the trough are similar. Oscillations of the trough position at dusk are in phase with substorm activity whereas movement of the trough at dawn is only apparent with the onset of the large storm. Detailed model calculations of the plasmasphere dynamics assuming a spatially invariant equatorial convection E-field which varies in step with the K sub p index produces a plasmapause motion which parallels the observed trough behaviour.

Grebowsky, J. M.↗

Positive isolation disconnect

A positive isolation disconnect was developed for component replacement in serviced liquid and gaseous spacecraft systems. Initially a survey of feasible concepts was made to determine the optimum method for fluid isolation, sealing techniques, coupling concepts, and foolproofing techniques. The top concepts were then further evaluated, including the fabrication of a semifunctional model. After all tradeoff analyses were made, a final configuration was designed and fabricated for development testing. This resulted in a 6.35 mm (1/4 inch) line and 12.7 mm (1/2 inch) line positive isolation disconnect, each unit consisting of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique was incorporated that prevents uncoupling of disconnect halves prior to fluid isolation.

Rosener, A. A.↗

Characteristics of the NASA Lewis bumpy-torus plasma generated with positive applied potentials

Experimental observations were made during steady-state operation of a bumpy-torus plasma at input powers up to 150 kW in deuterium and helium gas and with positive potentials applied to the midplane electrodes. In this steady-state ion heating method a modified Penning discharge is operated such that the plasma is acted upon by a combination of strong electric and magnetic fields. Experimental investigation of a deuterium plasma revealed electron temperatures from 14 to 140 eV and ion kinetic temperatures from 160 to 1785 eV. At least two distinct modes of operation exist. Experimental data shows that the average ion residence time in the plasma is virtually independent of the magnetic field strength. Data was taken when all 12 anode rings were at high voltage, and in other symmetric configurations in which the toroidal plasma was generated by applying positive potentials to six anode rings, three anode rings, and a single anode ring.

Roth, J. R.↗

Flight representative positive isolation disconnect

Resolutions were developed for each problem encountered and a tradeoff analysis was performed to select a final configuration for a flight representative PID (Positive Isolation Disconnect) that is reduced in size and comparable in weight and pressure drop to the developmental PID. A 6.35 mm (1/4-inch) line size PID was fabricated and tested. The flight representative PID consists of two coupled disconnect halves, each capable of fluid isolation with essentially zero clearance between them for zero leakage upon disconnect half disengagement. An interlocking foolproofing technique prevents uncoupling of disconnect halves prior to fluid isolation. Future development efforts for the Space Shuttle subsystems that would benefit from the use of the positive isolation disconnect are also recommended. Customary units were utilized for principal measurements and calculations with conversion factors being inserted in equations to convert the results to the international system of units.

Rosener, A. A.↗

The development of a positive isolation disconnect

Conceptual design and developmental testing were conducted to determine the feasibility of a highly reliable, positive isolation disconnect (PID) for potential inflight maintenance of Shuttle environmental control/life support system subsystems. The PID design consists of two coupled valves, each capable of fluid isolation through the use of individually operated opposing poppets. An integral level clamping mechanism couples the two valves and locks the bodies together. The coupling lever is locked in position by turning the valve stems that have foolproof caps. The stem shaft has an integral cam that turns inside a yoke to open the poppet to permit fluid flow. Results of 5000 life cycle tests, hydraulic lock test, leakage tests, and pressure drop tests are included.

Rosener, A. A.↗