Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Quaternary Cu 2 TSiS 4 (T = Fe, Mn) Anodes for Li-Ion Batteries

Developing high-capacity and fast-charging anode materials is critical for achieving high-performance Li-ion batteries (LIBs). Herein, polycrystalline quaternary transition metal silicon sulfides, Cu 2 TSiS 4 (T = Fe, Mn), were synthesized using a solid-state method and investigated as anode materials in LIBs. Cu 2 FeSiS 4 retains a reversible capacity of 670 mAh g –1 at 200 mA g –1 for 400 cycles, while Cu 2 MnSiS 4 suffers from a fast capacity loss in the initial 50 cycles. More importantly, Cu 2 FeSiS 4 can maintain a reversible capacity of 379 mAh g –1 after 700 cycles at a high current density of 2 A g –1 , demonstrating high cyclic stability and fast-charging capacity. To further understand the structure degradation and phase transformation, we investigated the postcycling electrodes using multiple techniques, including the scanning electron microscope with energy-dispersive X-ray spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy techniques. The results indicated that Cu 2 FeSiS 4 undergoes reversible phase transitions with Li 2 S as a major product component. To further assess the performance for practical applications, Cu 2 FeSiS 4 was coupled with LiFePO 4 to make LiFePO 4 ||Cu 2 FeSiS 4 full cells, which delivered superior electrochemical performance. These results demonstrate great promise for using quaternary transition metal silicon sulfides as anodes to achieve low-cost and sustainable LIBs.

25 ENERGY STORAGE↗

Investigation on thermo physical characteristics of ethylene glycol based Al:ZnO nanofluids

The present work describes the experimental aspects of viscosity and thermal conductivity characteristics of nanofluids. Aluminium doped zinc oxide nanostructures were synthesized by chemical precipitation method. Ultrasonic technique is used to disperse the nanostructures in ethylene glycol. Structural and morphological properties of Al doped ZnO nanostructures are characterized using X-ray diffractometer and scanning electron microscopic technique. The effect of concentration and temperature on thermo-physical properties of Al/ZnO nanofluids is also investigated. The experimental results showed there is enhancement in thermal conductivity with rise in temperature which can be utilized for coolant application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sol-gel reaction stability studied: Influence in the formation temperature and properties of ferroelectric thin films

Lead zirconium titanate (PZT) sol-gel solutions were prepared based on distilled lead acetate precursor solutions. A detailed analysis of the distillation effect on the lead precursor and the final PZT solution were carried out by Infrared and Raman techniques. It was found that the increase in the number of distillation steps experienced by the lead precursor solutions removes the constitutional water and increases the lead acetate-2-methoxyethanol interconnectivity; thus improving stability and avoiding the aging effect of the resulting PZT solutions. The thermal decomposition process of the PZT solutions was analyzed based on the thermogravimetric (TG) and differential thermogravimetric analysis (DTA) measurements. It was found that as the number of distillation steps in the lead precursor solutions increases, the decomposition rate increases and the formation temperature of pure perovskite PZT films decreases. X-ray diffraction (XRD) technique was used to study the film phase formation. A pure perovskite phase at 500 deg. C was found by the XRD analysis after the second distillation step. Scanning electron microscope technique was used to carry out the microstructural analysis. Dense microstructure was found in all analyzed films and an incipient columnar grain growth was revealed in PZT films prepared based on lead precursor solution with more than three distillation steps. The dependence of the dielectric, ferroelectric and piezoelectric properties on the number of distillation steps was revealed and a correlation between the distillation process, film microstructure properties and electrical performance was established.

36 MATERIALS SCIENCE↗

Prompt quality monitoring of InSe and GaSe semiconductor crystals by the nuclear quadrupole resonance technique

To determine the quality of layer-structured semiconductor single crystals, the nuclear quadrupole resonance technique with successive scanning of the entire sample volume and assessment of the structural quality on the basis of the observed spectra is used. The proposed method is appropriate in the case of InSe, GaSe and GaAs ingots grown in evacuated cells by the Bridgman technique and can be used repeatedly in subsequent technological procedures with no operator access to the material. To provide scanning within a limited region of the sample and to ensure efficient interaction of the high-frequency field with the crystal, excitation and detection of the nuclear-spin-induction signal is implemented by the saddle-shaped transceiver coil of the nuclear quadrupole resonance spectrometer.

36 MATERIALS SCIENCE↗

Dielectric relaxation studies in Se{sub 90}Cd{sub 8}Sb{sub 2} glassy alloy

Se{sub 90}Cd{sub 8}Sb{sub 2} chalcogenide semiconducting alloy was prepared by melt quench technique. The prepared glassy alloy has been characterized by techniques such as scanning electron microscopy (SEM) and energy dispersive X-ray (EDAX).Dielectric properties of Se{sub 90}Cd{sub 8}Sb{sub 2} chalcogenide semiconductor have been studied using impedance spectroscopic technique in the frequency range 5×10{sup 2}Hz - 1×10{sup 5}Hz and in temperature range 303-318K. It is found that dielectric constant ε′ and dielectric loss factor ε″ are dependent on frequency and temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Viewing Optical Processes at the Nanoscale: Combining Scanning Tunneling Microscopy and Optical Spectroscopy

The combination of optical spectroscopy and scanning tunneling microscopy techniques has the potential to yield the unambiguous single-molecule level insight required to fully understand the complex structure–property relationship of emerging material systems. In this Perspective, we highlight the recent progress of single-molecule absorption detected by scanning tunneling microscopy (SMA-STM) to investigate light–matter interactions of supported (nano)particles, quantum dots, and molecular and thin films at the nanoscale. We further show how the SMA-STM technique has been recently extended to expand the classes of materials that can be investigated as well as recent design modifications that enable both time-resolved imaging and tomography. Finally, we hypothesize how these modifications can be further leveraged to advance our current knowledge of light–matter interactions and how the resulting nanoscale insight can be implemented for future material applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-418: Evaluation of Organs at Risk (OAR) Sparing in Left Breast Irradiation Techniques

Purpose: To compare dose to organs at risk (OAR) for left sided breast radiation therapy with comparable planning target volume (PTV) coverage in three techniques; free breathing in supine position (FB), deep inspirational breath hold in supine (DIBH) and free breathing in prone position (PP). Methods: Ten left sided breast cancer patients suitable for this study underwent a CT scan in three techniques e.g. supine, FB and DIBH and prone position (PP). One radiation oncologist contoured the PTV and OAR (cardiac components) based on RTOG guidelines. Treatment plans were optimized using field-in-field technique with AAA algorithm. Each plan was optimized to provide identical coverage to PTV such that a reasonable comparison in OAR dosimetry can be evaluated. The prescribed dose to PTV were 42.56 Gy; 2.66 Gy in 16 fractions. Results: Average lung dose parameters; Dmean, V10, V20 and V30 were 0.5 Gy, 0.6%, 0.2%, and 0.1% respectively in PP which is significantly lower than FB (5.9 Gy, 14.2%, 10.7 %, and 8.4%) and DIBH (5.8 Gy, 14.3%, 10.2%, 7.8%). Similarly average heart Dmean, V2.5, V5, V10, and V20 were much lower in PP (1.2Gy, 9.1%, 2.1%, 0.8%, and 0.4%), and in DIBH (1.2 Gy, 10.6%, 1.7%, 0.5%, and 0.1%) compared to FB (2.6 Gy, 21%, 7.2%, 4.4% and 3.3%) respectively. Similar findings were also noted in the heart component left anterior descending artery (LAD) and Left ventricle (LV) which are correlated to radiation related toxicity. Conclusion: Based on the calculated dose, FB technique provides highest heart and lung dose. Prone has lowest lung dose, and DIBH has lowest LAD dose. It is found that PP is always superior for heart, LV, LAD and lung as compared to FB. This conclusion is in contrast to some published study concluding that prone position has no benefit for heart sparing.

60 APPLIED LIFE SCIENCES↗

Surface characterization of InP trenches embedded in oxide using scanning probe microscopy

Metrology for structural and electrical analyses at device level has been identified as one of the major challenges to be resolved for the sub-14 nm technology nodes. In these advanced nodes, new high mobility semiconductors, such as III–V compounds, are grown in narrow trenches on a Si substrate. Probing the nature of the defects, the defect density, and the role of processing steps on the surface of such structures are prime metrology requirements. In order to enable defect analysis on a (III–V) surface, a proper sample preparation for oxide removal is of primary importance. In this work, the effectiveness of different chemical cleanings and thermal annealing procedures is investigated on both blanket InP and oxide embedded InP trenches by means of scanning probe microscopy techniques. It is found that the most effective approach is a combination of an HCl-based chemical cleaning combined with a low-temperature thermal annealing leading to an oxide free surface with atomically flat areas. Scanning tunneling microscopy (STM) has been the preferred method for such investigations on blanket films due to its intrinsic sub-nm spatial resolution. However, its application on oxide embedded structures is non-trivial. To perform STM on the trenches of interest (generally <20 nm wide), we propose a combination of non-contact atomic force microscopy and STM using the same conductive atomic force microscopy tip Our results prove that with these procedures, it is possible to perform STM in narrow InP trenches showing stacking faults and surface reconstruction. Significant differences in terms of roughness and terrace formation are also observed between the blanket and the oxide embedded InP.

36 MATERIALS SCIENCE↗

SU-E-T-439: Fundamental Verification of Respiratory-Gated Spot Scanning Proton Beam Therapy

Purpose: The spot-scanning proton beam irradiation with respiratory gating technique provides quite well dose distribution and requires both dosimetric and geometric verification prior to clinical implementation. The purpose of this study is to evaluate the impact of gating irradiation as a fundamental verification. Methods: We evaluated field width, flatness, symmetry, and penumbra in the gated and non-gated proton beams. The respiration motion was distinguished into 3 patterns: 10, 20, and 30 mm. We compared these contents between the gated and non-gated beams. A 200 MeV proton beam from PROBEAT-III unit (Hitachi Co.Ltd) was used in this study. Respiratory gating irradiation was performed by Quasar phantom (MODUS medical devices) with a combination of dedicated respiratory gating system (ANZAI Medical Corporation). For radiochromic film dosimetry, the calibration curve was created with Gafchromic EBT3 film (Ashland) on FilmQA Pro 2014 (Ashland) as film analysis software. Results: The film was calibrated at the middle of spread out Bragg peak in passive proton beam. The field width, flatness and penumbra in non-gated proton irradiation with respiratory motion were larger than those of reference beam without respiratory motion: the maximum errors of the field width, flatness and penumbra in respiratory motion of 30 mm were 1.75% and 40.3% and 39.7%, respectively. The errors of flatness and penumbra in gating beam (motion: 30 mm, gating rate: 25%) were 0.0% and 2.91%, respectively. The results of symmetry in all proton beams with gating technique were within 0.6%. Conclusion: The field width, flatness, symmetry and penumbra were improved with the gating technique in proton beam. The spot scanning proton beam with gating technique is feasible for the motioned target.

60 APPLIED LIFE SCIENCES↗

Novel magnetic tips developed for the switching magnetization magnetic force microscopy.

Using micromagnetic calculations we search for optimal magnetic properties of novel magnetic tips to be used for a Switching Magnetization Magnetic Force Microscopy (SM-MFM), a novel technique based on two-pass scanning with reversed tip magnetization. Within the technique the sum of two scans images local atomic forces and their difference maps the local magnetic forces. The tip magnetization is switched during the scanning by a small magnetic field. The technology of novel low-coercitive magnetic tips is proposed. For best performance the tips must exhibit low magnetic moment, low switching field, and single-domain state at remanence. Such tips are equipped with Permalloy objects of a precise shape that are defined on their tilted sides. We calculate switching fields of such tips by solving the micromagnetic problem to find the optimum shape and dimensions of the Permalloy objects located on the tips. Among them, hexagon was found as the best shape for the tips.

36 MATERIALS SCIENCE↗

Strain mapping at nanometer resolution using advanced nano-beam electron diffraction

In this work, we report on the development of a nanometer scale strain mapping technique by means of scanning nano-beam electron diffraction. Only recently possible due to fast acquisition with a direct electron detector, this technique allows for strain mapping with a high precision of 0.1% at a lateral resolution of 1 nm for a large field of view reaching up to 1 μm. We demonstrate its application to a technologically relevant strain-engineered GaAs/GaAsP hetero-structure and show that the method can even be applied to highly defected regions with substantial changes in local crystal orientation. Strain maps derived from atomically resolved scanning transmission electron microscopy images were used to validate the accuracy, precision and resolution of this versatile technique.

36 MATERIALS SCIENCE↗

Adapting polychromatic X-ray microdiffraction techniques to high-pressure research: energy scan approach

Polychromatic single-crystal diffraction (pSXD) offers important advantages compared with monochromatic diffraction, such as ultrafast data collection and the ability to collect diffraction data without sample rotation. Despite the relevance of these advantages for applications in high-pressure experiments, pSXD has never been successfully applied for full structure determination at high pressure. Here the theory of polychromatic microdiffraction, strategies developed to adapt it to high-pressure applications, and results of pilot experiments are described. Special emphasis is placed on experiments with microcrystals and multigrain aggregates, and on the use of monochromator scans to extend the pressure range for single-crystal structure determination to the megabar region. Closely related applications to materials research problems are also discussed.

43 PARTICLE ACCELERATORS↗

Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods-including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations-and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave breast imaging. Optical distortions imposed by the imaging tank and coupling bath diminished the effectiveness of the ray tracing approach; however, calibration through image registration techniques reliably produced scans of submillimeter accuracy. Tests of the system with breast-shaped phantoms demonstrated the successful implementation of the scanner for the intended application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection and quantification of residual alpha-phase in delta-stabilized plutonium

The temperature range of the {delta}-phase field of plutonium can be expanded by alloying with Group IIIA elements. Ga is a particularly potent {delta}-stabilizer and effectively stabilizes the {delta}-phase to room temperature. Due to a strong propensity towards solute redistribution during cooling through the {var_epsilon} {yields} {delta} phase field, regions of the material often do not contain enough solute to stabilize the {delta}-phase even after extensive homogenization annealing in the {delta}-phase field . The result is a small but persistent, fraction of {alpha}-phase in the material. A technique using differential scanning calorimetry to measure the enthalpy of transformation of the plutonium {alpha} {yields} {beta} transformation is described which can detect and quantify {alpha}-phase in a {delta}-phase matrix at levels as low as {approx} 0.1 wt. %. A set of Pu-1.7 atomic % Ga alloys was examined using the technique and found to contain 0.32 {+-} 0.06 weight % {alpha}-phase. Complications arise due to interference from the pressure-induced {alpha}{prime}-phase, and a peak separation method was developed to accurately measure the heat signal from each phase. Due to the presence of Ga in the {alpha}-phase, the onset temperature of the {alpha} {yields} {beta} transformation in these specimens was found to be 140.2 C, significantly higher than that for the transformation in pure plutonium, 126.2 C.

36 MATERIALS SCIENCE↗

Characterization of the correlation between the interfaces and failure behaviors for particle reinforced Mg–Li composites

The interfacial microstructure of SiC{sub p} or YAl{sub 2p} reinforced Mg–14Li–3Al matrix composites was comparatively characterized by scanning electron microscopy and electron probe microanalysis. A nanoindentation combined with scanning electron microscopy technique was used to characterize the interfacial mechanical properties between the reinforcements and matrix. The interfacial strength and failure behaviors for the composites were analyzed from the load–penetration curves and corresponding images. In situ tensile tests were used to observe the fracture and deformation processes with the aid of scanning electron microscopy. The results show that both the chemical and mechanical compatibilities between the YAl{sub 2} particles and LA143 matrix are better than those between the SiC particles and LA143 matrix. The interfacial breakage load for the SiC/LA143 composite is lower than that for the YAl{sub 2}/LA143 composite because of the worse chemical and mechanical compatibilities between the ceramic particles and metal matrix. Interfacial breakage is the main failure mechanism for the SiC/LA143 composite, while the particle breakage and matrix crack are the main failure mechanism for the YAl{sub 2}/LA143 composite. These may be related to the stronger interfacial bonding between the intermetallic particles and metal matrix. - Highlights: • The compatibility for YAl{sub 2} particle with LA143 matrix is better than SiC particle. • The strength of the YAl{sub 2}/LA143 interface is higher than the SiC/LA143 interface. • The main failure behavior for the SiC/LA143 composite is interfacial breakage. • The main failure behavior for YAl{sub 2}/LA143 composite is particle and matrix breakage. • The interfacial strength plays an important role on the composite failure behavior.

36 MATERIALS SCIENCE↗

SU-E-T-266: Proton PBS Plan Design and Robustness Evaluation for Head and Neck Cancers

Purpose: To describe a newly designed proton pencil beam scanning (PBS) planning technique for radiotherapy of patients with bilateral oropharyngeal cancer, and to assess plan robustness. Methods: We treated 10 patients with proton PBS plans using 2 posterior oblique field (2F PBS) comprised of 80% single-field uniform dose (SFUD) and 20% intensity-modulated proton therapy (IMPT). All patients underwent weekly CT scans for verification. Using dosimetric indicators for both targets and organs at risk (OARs), we quantitatively compared initial plans and verification plans using student t-tests. We created a second proton PBS plan for each patient using 2 posterior oblique plus 1 anterior field comprised of 100% SFUD (3F PBS). We assessed plan robustness for both proton plan groups, as well as a photon volumetric modulated arc therapy (VMAT) plan group by comparing initial and verification plans. Results: The 2F PBS plans were not robust in target coverage. D98% for clinical target volume (CTV) degraded from 100% to 96% on average, with maximum change Δ D98% of −24%. Two patients were moved to photon VMAT treatment due to insufficient CTV coverage on verification plans. Plan robustness was especially weak in the low-anterior neck. The 3F PBS plans, however, demonstrated robust target coverage, which was comparable to the VMAT photon plan group. Doses to oral cavity were lower in the Proton PBS plans compared to photon VMAT plans due to no lower exit dose to the oral cavity. Conclusion: Proton PBS plans using 2 posterior oblique fields were not robust for CTV coverage, due to variable positioning of redundant soft tissue in the posterior neck. We designed 3-field proton PBS plans using an anterior field to avoid long heterogeneous paths in the low neck. These 3-field proton PBS plans had significantly improved plan robustness, and the robustness is comparable to VMAT photon plans.

60 APPLIED LIFE SCIENCES↗

Readout models for BaFBr 0.85 I 0.15 :Eu image plates

The linearity of the photostimulated luminescence process makes repeated image-plate scanning a viable technique to extract more dynamic range. In order to obtain a response estimate, two semi-empirical models for the readout fading of an image plate are introduced; they relate the depth distribution of activated photostimulated luminescence centers within an image plate to the recorded signal. Model parameters are estimated from image-plate scan series with BAS-MS image plates and the Typhoon FLA 7000 scanner for the hard x-ray image-plate diagnostic over a collection of experiments providing x-ray energy spectra whose approximate shape is a double exponential.

47 OTHER INSTRUMENTATION↗