Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transition Edge Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Sunyaev-Zel'Dovich effect observations of the bullet cluster (1E 0657-56) with APEX-SZ

We present observations of the Sunyaev-Zel'dovich effect (SZE) in the Bullet cluster (1E 0657-56) using the APEX-SZ instrument at 150 GHz with a resolution of 1'. The main results are maps of the SZE in this massive, merging galaxy cluster. The cluster is detected with 23 sigma significance within the central 1' radius of the source position. The SZE map has a broadly similar morphology to that in existing X-ray maps of this system, and we find no evidence for significant contamination of the SZE emission by radio or IR sources. In order to make simple quantitative comparisons with cluster gas models derived from X-ray observations, we fit our data to an isothermal elliptical beta model, despite the inadequacy of such a model for this complex merging system. With an X-ray derived prior on the power-law index, beta = 1.04+0.16-0.10, we find a core radius rc = 142" +- 18", an axial ratio of 0.889 +- 0.072, and a central temperature decrement of -771 +- 71 muKCMB, including a +-5.5percent flux calibration uncertainty. Combining the APEX-SZ map with a map of projected electron surface density from Chandra X-ray observations, we determine the mass-weighted temperature of the cluster gas to be Tmg = 10.8 +- 0.9 keV, significantly lower than some previously reported X-ray spectroscopic temperatures. Under the assumption of an isothermal cluster gas distribution in hydrostatic equilibrium, we compute the gas mass fraction for prolate and oblate spheroidal geometries and find it to be consistent with previous results from X-ray and weak-lensing observations. This work is the first result from the APEX-SZ experiment and represents the first reported scientific result from observations with a large array of multiplexed superconducting transition-edge sensor bolometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and fabrication of Argonne/KICP detectors for CMB polarization.

We present the design, microfabrication and assembly of dual-polarization absorber-coupled Transition Edge Sensor (TES) bolometer detectors for cosmic microwave background B-mode polarization studies. The device consists of two separate dies incorporating suspended silicon nitride membranes within silicon frames, carefully aligned perpendicularly and fixtured face-to-face. Polarization sensitivity around 95 GHz is provided by a single dipole-like absorber element; we briefly analyze this absorber-in-waveguide configuration in closed form using the EMF method. Proximity effect Mo/Au bilayers provide control of the TES critical temperature between 400 mK and 600 mK, with a normal resistance R{sub n} {approx} 1{Omega}. DC magnetron sputtering, wet etching, and liftoff were employed for TES fabrication. Optimization of the superconducting Mo thin film utilized independent RF bias applied to the substrate during deposition in a confocal geometry. This technique allows outstanding thin film uniformity and stress to be achieved simultaneously over a 4-inch wafer surface, leading to excellent superconducting properties. Device thermal conductance in the range from 25-250pW/K was achieved using suspended silicon nitride membranes 1 micron thick. The value of the thermal conductance depends very strongly upon the surface roughness, and therefore in turn upon the treatment of the silicon nitride material during fabrication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical properties of Argonne/KICP TES bolometers for CMB polarimetry.

We present optical data on prototype polarization sensitive Argonne/KICP detectors fabricated at Argonne National Labs which are designed to be installed on the South Pole Telescope and used to measure the polarization of the Cosmic Microwave Background radiation. The detectors are Mo/Au transition edge sensors (TES) suspended on silicon nitride, with radiation coupled to the TES using a gold bar absorber. Two stacked detectors with bars in orthogonal directions will be used to measure both polarizations. We discuss measurements of the optical bandpass, time constants and cross-polarization of the detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High rate pulse processing algorithms for microcalorimeters

It has been demonstrated that microcalorimeter spectrometers based on superconducting transition-edge-sensor can readily achieve sub-100 eV energy resolution near 100 keV. However, the active volume of a single microcalorimeter has to be small to maintain good energy resolution, and pulse decay times are normally in the order of milliseconds due to slow thermal relaxation. Consequently, spectrometers are typically built with an array of microcalorimeters to increase detection efficiency and count rate. Large arrays, however, require as much pulse processing as possible to be performed at the front end of the readout electronics to avoid transferring large amounts of waveform data to a host computer for processing. In this paper, they present digital filtering algorithms for processing microcalorimeter pulses in real time at high count rates. The goal for these algorithms, which are being implemented in the readout electronics that they are also currently developing, is to achieve sufficiently good energy resolution for most applications while being (a) simple enough to be implemented in the readout electronics and (b) capable of processing overlapping pulses and thus achieving much higher output count rates than the rates that existing algorithms are currently achieving. Details of these algorithms are presented, and their performance was compared to that of the 'optimal filter' that is the dominant pulse processing algorithm in the cryogenic-detector community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic microcalorimeter system for ultra-high resolution alpha-particle spectrometry

Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with {approx}15 uK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis, This paper will discuss design and operation of our microcalorimeter alpha spectrometer, and will show recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Maturation of Edge Sensor Technology and Potential Application in Large Space Telescopes with Segmented Primary Mirrors

This paper explores the history and results of the last two year's efforts to transition inductive edge sensor technology from Technology Readiness Level 2 to Technology Readiness Level 6. Both technical and programmatic challenges were overcome in the design, fabrication, test, and installation of over a thousand sensors making up the Segment Alignment Maintenance System (SAMs) for the 91 segment, 9.2-meter. Hobby Eberly Telescope (HET). The integration of these sensors with the control system will be discussed along with serendipitous leverage they provided for both initialization alignment and operational maintenance. The experience gained important insights into the fundamental motion mechanics of large segmented mirrors, the relative importance of the variance sources of misalignment errors, the efficient conduct of a program to mature the technology to the higher levels. Unanticipated factors required the team to develop new implementation strategies for the edge sensor information which enabled major segmented mirror controller design simplifications. The resulting increase in the science efficiency of HET will be shown. Finally, the on-going effort to complete the maturation of inductive edge sensor by delivering space qualified versions for future IR (infrared radiation) space telescopes.

Montgomery, Edward E., IV↗

Kinetic Inductance Detectors for Dark Matter Searches

Decades of astrophysical observations suggest that 23% of the mass energy of the universe is dark. Meanwhile, particle physics theories favor the existence of a stable and weakly interacting particle, which has yet to be detected. These realities combine to formulate a very well motivated particle dark matter candidate, which was produced in the early universe and still lingers in abundance today. The expectation of a small weak interaction cross-section enables the instrumentation of experiments designed to discover the nature of the dark matter which continues to be an overarching question of cosmology. A detector for this dark matter candidate senses energy from occasional collisions between the dark matter and atomic nuclei; the more nuclei in the detector, the greater its sensitivity to dark matter. The detectors of the Cryogenic Dark Matter Search (CDMS) measure phonons and charge emanating from recoiling germanium nuclei. Its phonon sensors, though exquisitely sensitive, are relatively complicated to fabricate and deploy. Responding to the scientific imperative to increase dark matter sensitivity, we look for a simpler phonon sensor technology. Kinetic inductance based phonon sensors (KIPS) are superconducting thin film microwave frequency resonant circuits. Phonon energy impinging on the film alters its surface impedance, which alters the characteristics of the resonance. KIPS can be made with relatively large, millimeter sized features which makes them easier to fabricate and reduces variations between detectors. This instrumentation focused thesis shows that KIPS can be used as a simple and sensitive phonon sensor for the CDMS detector. KIPS design aspects, competitiveness to the current transition edge phonon sensors, readout considerations and suggestions on how to instrument them in future dark matter experiments will be presented. The broader applicability of KIPS in nuclear non-proliferation and other physics investigations is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconducting detectors for rare event searches in experimental astroparticle physics

Superconducting detectors have become an important tool in experimental astroparticle physics, which seeks to provide a fundamental understanding of the Universe. In particular, such detectors have demonstrated excellent potential in two challenging research areas involving rare event search experiments, namely, the direct detection of dark matter (DM) and the search for neutrinoless double beta decay. Here, we review the superconducting detectors that have been and are planned to be used in these two categories of experiments. We first provide brief histories of the two research areas and outline their significance and challenges in astroparticle physics. Then, we present an extensive overview of various types of superconducting detectors with a focus on sensor technologies and detector physics, which are based on calorimetric measurements and heat flow in the detector components. Finally, we introduce leading experiments and discuss their future prospects for the detection of DM and the search for neutrinoless double beta decay employing superconducting detectors.

transition edge sensors↗

Improved plutonium and americium photon branching ratios from microcalorimeter gamma spectroscopy

Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution - (60–70 eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium ( 238 Pu, 239 Pu, 241 Pu) and 241 Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. Lastly, we show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2–3 for four branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g silicon athermal phonon detector with a baseline energy resolution of 4.92 +/- 0.01 eV. This exclusion analysis sets the most stringent dark matter-nucleon cross-section limits for masses from 87--140 MeV/c^2 , with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientic potential of athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

Alkhatib, I↗

Characterization of Aliased Noise in the Advanced ACTPol Receiver

Advanced ACTPol is the second-generation polarization-sensitive upgrade to the 6m aperture Atacama Cosmology Telescope (ACT), which increased detector count and frequency coverage compared to the previous ACTPol receiver. Advanced ACTPol utilizes a new two-stage time-division multiplexing readout architecture based on superconducting quantum interference devices to achieve a multiplexing factor as high as 64 (rows), fielding a 2012 detector camera at 150/220 GHz and two 90/150 GHz cameras containing 1716 detectors each. In a time-domain system, aliasing introduces noise to the readout. Here in this work we present a figure of merit to measure this noise contribution and present measurements of the aliased noise fraction of the Advanced ACTPol receiver as deployed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BICEP Array: 150 GHz Detector Module Development

The Background Imaging of Cosmic Extragalactic Polarization (BICEP)/Keck (BK) collaboration is currently leading the quest for the highest-sensitivity measurements of the polarized cosmic microwave background (CMB) anisotropies on a degree scale with a series of cryogenic telescopes, of which BICEP Array (BA) is the latest Stage-3 upgrade with a total of ~ 32,000 detectors. The instrument comprises 4 receivers spanning 30–270 GHz, with the low-frequency 30/40 GHz deployed to the South Pole Station in late 2019. The full complement of receivers is forecast to set the most stringent constraints on the tensor-to-scalar ratio r. Building on these advances, the overarching small-aperture telescope concept is already being used as the reference for further Stage-4 experiment design. This paper describes the development of the BICEP Array 150 GHz detector module and its fabrication requirements, with highlights on the high-density time division multiplexing (TDM) design of the cryogenic circuit boards. The low-impedance wiring required between the detectors and the frst stage of superconducting quantum interference device amplifers is crucial to maintaining a stable bias current on the detectors. Here, a novel multilayer FR4 Printed Circuit Board with superconducting traces, capable of reading out up to 648 detectors, is detailed along with its validation tests. An ultra-high-density TDM detector module concept we developed for a CMB-S4-like experiment that allows up to 1920 detectors to be read out is also presented. TDM has been chosen as the detector readout technology for the Cosmic Microwave Background Stage-4 (CMB-S4) experiment based on its proven low-noise performance, predictable costs, and overall maturity of the architecture. The heritage for TDM is rooted in mm- and sub-mm-wave experiments dating back 20 years and has since evolved to support a multiplexing factor of 64x in Stage-3 experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Results and Limits of Time-Division Multiplexing for the BICEP Array High-Frequency Receivers

Time-division multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high-frequency receivers, observing at 150 GHz and 220/270 GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard multichannel electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates time-division multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and cross talk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Finally, future experiments like CMB-S4 plan to use TES bolometers with time-division/SQUID-based readout for an even larger number of detectors.

47 OTHER INSTRUMENTATION↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

For this work, we have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗