Search NASASearch

SEARCH · Search NASA

Results for “U-GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

476 records · Page 27

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg

Observational evidence for Criegee intermediate oligomerization reactions relevant to aerosol formation in the troposphere

Criegee intermediates are reactive intermediates that are implicated in transforming the composition of Earth’s troposphere and in the formation of secondary organic aerosol, impacting Earth’s radiation balance, air quality and human health. Yet, direct identification of their signatures in the field remains elusive. Here, from particulate and gas-phase mass-spectrometric measurements in the Amazon rainforest, we identify sequences of masses consistent with the expected signatures of oligomerization of the CH 2 OO Criegee intermediate, a process implicated in ozonolysis-driven aerosol formation. In this study, we assess the potential contributions of oligomerization through laboratory ozonolysis experiments, direct kinetic studies of Criegee intermediate reactions, and high-level theoretical calculations. Global atmospheric models built on these kinetics results indicate that Criegee intermediate chemistry may play a larger role in altering the composition of Earth’s troposphere than is captured in current atmospheric models, especially in areas of high humidity. However, the models still capture only a relatively small fraction of the observed signatures, suggesting considerable underestimates of Criegee intermediate concentrations and reactivity and/or the dominance of other, presently uncharacterized, oxidation mechanisms. Resolving the remaining uncertainties in emission inventories and the effects of atmospheric water vapour on key chemical reactions will be required to definitively assess the role of Criegee intermediate oligomerization reactions.

58 GEOSCIENCES

Physics basis for the reference flat-top plasma scenario in the ST–E1 fusion power plant

As part of the U.S. Department of Energy’s Milestone-Based Fusion Energy Development Program, Tokamak Energy has completed the pre-concept design of the ST–E1 fusion power plant. ST–E1 is envisaged to operate in two phases: a pilot plant phase, targeting sustained net power production of 300 - 500 MWe for a duration >1 hr, followed by a commercial power plant phase targeting steady-state operations and a normalised overnight capital cost of ⩽12 000 $\$$/kWe. The design process adopted was highly iterative, integrating all major plant systems and progressing in a phased fidelity approach. At the pre-conceptual stage, the emphasis has been on exploring the design space, identifying the main system-level trade-offs, and making the key decisions that define the overall plant concept, rather than optimising a single operating point. This paper, part of a focused collection detailing the ST–E1 pre-concept design, addresses the development of a series of reference flat-top plasma operating points for the pilot plant phase. A modelling workflow was established to develop and assess candidate plasma design points and explore key dependencies. The workflow includes integrated core plasma modelling, magnetohydrodynamic (MHD) stability assessment, equilibrium generation, scrape-off-layer and exhaust modelling, heating & current drive design and optimisation, and turbulent transport modelling. Using this framework, the impact of several key parameters on the flat-top operating space was investigated, including the density limit, core radiation fraction and divertor power loading, level of external heating and curent drive power and assumed pedestal characteristics. The MHD stability, controllability and micro-stability characteristics of these plasmas were also analysed. These investigations informed the definition of a set of fully non-inductive, flat-top reference operating points that satisfy the high-level ST–E1 mission, including a low and high density case, a case that is stable to resistive wall modes and a case with reduced divertor power loading.

ST–E1

Advances in Design Capabilities for Planetary Missions from the NASA Entry Systems Modeling and Instrumentation Portfolio

The Entry Systems Modeling project (ESM) is supported by both the NASA Space Technology and the Science Mission Directorates and focuses on developing simulation tools and validated models for characterizing the performance of entry systems tailored to planetary destinations across the Solar System. ESM is organized into six technical capability areas that together address all relevant factors related to spacecraft entry, as well as some aspects of descent: Thermal Protection System (TPS) Materials; Aerothermodynamics; Entry & Descent Vehicle Dynamics; Guidance, Navigation, and Control; Vehicle Systems Analysis; and Advanced Tools and Numerical Methods. Development within the capability areas is undertaken explicitly with a focus on transition and infusion to science missions, human exploration missions, and commercial space activities. The present talk details developments that specifically impact science missions, including simulation tool capabilities that aid in mission design and model development to understand entry system performance at a given destination. Examples of the successful infusion and transition of such project outcomes to science missions also are provided. Several simulation tool development efforts within ESM have resulted in new design capabilities for missions. One such outcome is improved toolsets for mission trajectory and concept of operations design. Specifically, an initiative to couple a leading tool for entry, ascent/descent, and orbital trajectory optimization (Program to Optimize Simulated Trajectories II or POST2) to those used within the Agency for interplanetary trajectory optimization (Copernicus and Monte) has made substantial progress, with the outcomes to date promising to allow efficient trajectory optimization across mission phases. Additionally, toolchains for the evaluation of vehicle performance during entry and descent have been developed that allow assessment of multi-dimensional aeroheating on detailed vehicle geometries, characterization of deployment and inflation of parachutes, and assessment of vehicle dynamic stability during descent. These capabilities are achieved by coupling diverse sets of physics together – material response, computational fluid dynamics, radiation, and vehicle dynamics – to suitably describe complex entry and descent phenomena. Several model development and validation efforts for specific destinations and entry regimes also are underway within the ESM project. For instance, new experimental capabilities to validate radiation models at low densities/high altitudes recently have been established with project support, specifically the Low-Density Shock Tube (LDST) at the NASA Ames Research Center Electric Arc Shock Tube (EAST) facility. The LDST is being leveraged to develop improved models of shock layer kinetics and radiation in Titan atmospheres, while future studies will be conducted in the LDST and the existing high velocity shock tube to provide validation data for radiation models of Venus, Ice Giants, and Mars atmospheres. Models describing the aerothermal and thermo-structural performance of Thermal Protection System (TPS) materials has been another focus, with multiscale modeling activities on-going for the two leading TPS materials applicable to a range of entry conditions and science missions: the Phenolic-Impregnated Carbon Ablator (PICA) and woven materials like 3D Mid-Density Carbon Phenolic (3MDCP). A continual effort is made to infuse and transition outcomes from ESM simulation tool and model development activities into relevant science missions. Significant progress has been made on this front, with missions such as Dragonfly, DAVINCI, and Mars Missions benefitting from project outcomes. The groundwork also is being laid to provide insights into forward looking missions to Gas/Ice Giants as well as for potential sample returns.

Justin Haskins

The Dark Energy Survey supernova program: a reanalysis of cosmology results and evidence for evolving dark energy with an updated Type Ia supernova calibration

We present improved cosmological constraints from a re-analysis of the Dark Energy Survey (DES) 5-year sample of Type Ia supernovae (DES-SN5YR). This re-analysis includes an improved photometric cross-calibration, recent white dwarf observations to cross-calibrate between DES and low-redshift surveys, retraining the salt3 light-curve model and fixing a numerical approximation in the host-galaxy colour law. Our fully recalibrated sample, which we call DES-Dovekie, comprises ~1600 likely Type Ia SNe from DES and ~200 low-redshift SNe from other surveys. With DES-Dovekie, we obtain Ω m = 0.330 ± 0.015 in flat Lambda-cold dark matter (⁠ΛCDM) which changes Ω m by –0.022 compared to DES-SN5YR. Combining DES-Dovekie with cosmic microwave background data from Planck, Atacama Cosmology Telescope, and South Pole Telescope and the DESI DR2 measurements in a flat CDM cosmology, we find ω 0 = –0.803 ± 0.054 and ω a = –0.72 ± 0.21⁠. Our results hold a significance of 3.2σ, reduced from 4.2σ for DES-SN5YR, to reject the null hypothesis that the data are compatible with the cosmological constant. This significance is equivalent to a Bayesian model preference odds of approximately 5:1 in favour of the flat ω 0 ω a CDM model. Using generally accepted thresholds for model preference, our updated data exhibits only a weak preference for evolving dark energy.

dark energy

Photophoretic Propulsion Enabling Mesosphere Exploration NIAC Phase I Final Report

This Phase I report presents a comprehensive study on photophoretic flyers—innovative, ultralight, solar-powered vehicles that harness photophoretic forces generated via Knudsen pumping to achieve sustained flight in the mesosphere (50–80 km altitude). By integrating advanced materials such as nanocardboard— characterized by its extremely low areal density (~1 g/m²) and high bending stiffness—with ultrathin light-absorbing coatings, the project converts incident solar radiation directly into a directed thrust. Extensive experimental investigations, coupled with high-fidelity computational fluid dynamics (CFD) simulations using ANSYS Fluent, validate the concept across various three-dimensional geometries, including spherical, conical, and rocket-shaped configurations. These simulations bridge the gap between free-molecular and continuum flow regimes, demonstrating that optimized designs can generate lift forces sufficient to support kilogram-scale payloads even in low-pressure environments. At the heart of this innovation is the use of Knudsen pumping, where temperature gradients across porous surfaces induce directional gas flow, creating a modest overpressure that provides lift. The report introduces an analytical framework that interpolates between the well-known low-Reynolds number drag regime and the high-Reynolds number momentum theory. This model accurately predicts lift based on design parameters such as microchannel dimensions, porous wall geometry, areal density, and nozzle exit area. For instance, simulations indicate that 10-meter-scale structures with carefully engineered porous walls can achieve the necessary pressure differential to support scientifically significant payloads (~1 kg). The study also explores a hybrid propulsion approach that combines solar buoyancy with photophoretic lift. Initially, solar heating creates a buoyant force that elevates the flyer to mesospheric altitudes. Once in the optimal pressure range, the photophoretic mechanism—powered by Knudsen pumping—takes over as the primary source of lift, ensuring stable, long-duration flight. This dual-mode operation not only facilitates the deployment of photophoretic flyers but also broadens the potential applications for mesospheric exploration. In addition to propulsion, the report investigates the integration of photophoretic thrusters for trajectory control of existing research balloons in the upper stratosphere. By dynamically adjusting the nozzle orientation and controlling the flow-through velocity, these thrusters provide precise maneuverability, enabling the flyers to counteract atmospheric disturbances and adjust their flight paths in real time. For example, a photophoretic thruster approximately 7.5 by 7.5 meters in size could be unfolded below a payload gondola of a 60 million-cubic-foot zero-pressure balloon. Such a thruster can provide horizontal speed control of approximately 1 m/s using only sunlight and no moving parts (except those needed to track the Sun and control the jet direction). Importantly, photophoretic thrusters operate more efficiently at higher altitudes, which is complementary to known trajectory control techniques, such as propellers and tethered wings, which are more effective at lower altitudes. Finally, the report identifies three scientific research thrusts where mesospheric aircraft technology can have a profound impact: atmospheric tides, characterization of gravity waves, and investigation of mesospheric instabilities. Overall, the findings of this Phase I project represent a significant advancement in photophoretic propulsion technology. By demonstrating that large-scale, ultralight structures can be powered solely by solar radiation—via carefully engineered Knudsen pumping—this work lays a robust foundation for scalable, near-space flight architectures. Future refinements in material fabrication, structural optimization, and integrated trajectory control are expected to further enhance performance, paving the way for operational demonstrations that could revolutionize atmospheric science, remote sensing, and communication networks.

Knudsen Pump

Experimental observation and integrated modelling of proton-beryllium fusion in He and D plasmas at JET

Validated integrated modelling of JET ITER-like wall experiments in which fusion performance is driven by reactions between fast ions and intrinsically present metal wall impurities is presented. A steady-state L-mode plasma with dominant proton-beryllium fusion and neutron yields of up to ≈ 6·10 13 s -1 is developed in He and D, via radiofrequency heating of a H minority. The fusion drive is unambiguously confirmed by the neutral particle analyser, fast ion loss detector, and γ-ray diagnostics. Experiments are analysed via an integrated modelling framework, developed to model the two-stage proton beryllium-fusion chain and produce high-fidelity fusion product source terms. The modelling chain comprises TRANSP and JETTO for plasma core modelling, LOCUST for full orbit product tracking and collisional slowing-down, DRESS to resolve two- and three-body fusion kinematics, and MCNP for neutron transport calculations. Modelling shows that the primary 9 Be(p,n) 9 B reaction is the dominant neutron emitter at naturally present concentrations of beryllium in these experiments. The yield contribution of secondary reactions between fusion products and beryllium, 9 Be(d,n) 10 B and 9 Be(α,n) 12 C, is found to be negligible. The proton-deuteron knock-on effect in D plasmas is modelled, which is calculated to contribute ≈ 25% to the total neutron yield. For both He and D discharges the total computed neutron rates match fission chamber (FC) measurements within the combined experimental and computational uncertainty, with an average discrepancy of ≈ ± 20%. Realistic proton-beryllium neutron sources are propagated through JET’s MCNP neutron transport model which shows that 235 U FCs’ response is sensitive to p–Be source changes, with up to ≈ 10% variation compared to a D–D neutron source. We show that the high-energy tail of the fast proton minority can be studied with multi-foil neutron activation. The framework is also applied to the study of interactions between fast protons and boron impurities, of relevance to ITER. We calculate that in JET conditions a significant alpha source with DT-like energies could be generated through 11 B(p, α)2α fusion, and detected via γ-emission in secondary interactions between fast alphas and boron. The work represents an important step towards validating predictive integrated modelling capabilities for non-standard fusion reactions.

JET

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI