Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

A Vision–based Robust $\mathcal{H}$ ∞ Gain Scheduling Longitudinal and Lateral Following Controller for Autonomous Vehicles on Urban Curved Roads

Implementing advanced driver assistance systems (ADAS) in congested and intricate urban traffic scenarios poses significant challenges. To address the frequent stop–and–go motions exhibited by autonomous vehicles (AVs) navigating urban roads with changes in curvature, we propose a vision–based robust $\mathcal{H}$ ∞ adaptive cruise control system (ACC) for longitudinal control, plus a lane keeping assist system (LKAS) for lateral control. For the vision-based ACC, a weighted probability objective function for the vehicle following behavior is formulated. We incorporate $\mathcal{H}$ ∞ performance and gain scheduling techniques to mitigate the impact of uncertainty in visual sensor measurements. Furthermore, the optimal time headway is scheduled based on the velocity to ensure traffic flow efficiency and safety during the vehicle following process. For the LKAS, we introduce a road curvature estimation method that integrates lane and vehicle dynamics information to obtain the lateral and heading offsets. Next, the design criterion of the observer–based robust gain scheduling lateral motion controller is established by linear matrix inequality (LMI). Here, a series of experiments conducted within a camera–in–loop platform validate the proposed method.

33 ADVANCED PROPULSION SYSTEMS↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Ab initio molecular dynamics on quantum computers

Ab initio molecular dynamics (AIMD) is a valuable technique for studying molecules and materials at finite temperatures where the nuclei evolve on potential energy surfaces obtained from accurate electronic structure calculations. In this work, we present an approach to running AIMD simulations on noisy intermediate-scale quantum (NISQ)-era quantum computers. The electronic energies are calculated on a quantum computer using the variational quantum eigensolver (VQE) method. Algorithms for computation of analytical gradients entirely on a quantum computer require quantum fault-tolerant hardware, which is beyond NISQ-era. Therefore, we compute the energy gradients numerically using finite differences, the Hellmann-Feynman theorem, and a correlated sampling technique. This method only requires additional classical calculations of electron integrals for each degree of freedom without any additional computations on a quantum computer beyond the initial VQE run. As a proof of concept, AIMD simulations are demonstrated for the H-2 molecule on IBM quantum devices. In addition, we demonstrate the validity of the method for larger molecules using full configuration interaction wave functions. As quantum hardware and noise mitigation techniques continue to improve, the method can be utilized for studying larger molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CATMoS: Collaborative Acute Toxicity Modeling Suite

Background: Humans are exposed to tens of thousands of chemical substances that need to be assessed for their potential toxicity. Acute systemic toxicity testing serves as the basis for regulatory hazard classification, labeling, and risk management. However, it is cost- and time-prohibitive to evaluate all new and existing chemicals using traditional rodent acute toxicity tests. In silico models built using existing data facilitate rapid acute toxicity predictions without using animals. Objectives: The U.S. Interagency Coordinating Committee on the Validation of Alternative Methods Acute Toxicity Workgroup organized an international collaboration to develop in silico models for predicting acute oral toxicity based on five different endpoints: LD50 value, U.S. Environmental Protection Agency hazard categories, Globally Harmonized System for Classification and Labelling hazard categories, very toxic chemicals (LD50 =50 mg/kg), and non-toxic chemicals (LD50 >2000 mg/kg). Methods: An acute oral toxicity data inventory for 11,992 chemicals was compiled, split into training and evaluation sets, and made available to 35 participating international research groups that submitted a total of 139 predictive models. Predictions that fell within the applicability domains of the submitted models were evaluated using external validation sets. These were then combined into consensus models to leverage strengths of individual approaches. Results: The resulting consensus predictions, which leverage the collective strengths of each individual model, form the Collaborative Acute Toxicity Modeling Suite (CATMoS). CATMoS demonstrated high performance in terms of accuracy and robustness when compared to in vivo results. Discussion: CATMoS is being evaluated by regulatory agencies for its utility and applicability as a potential replacement for in vivo rat acute oral toxicity studies. CATMoS predictions for over 800,000 chemicals have been made available via the NTP’s Integrated Chemical Environment. The models are also implemented in a free, standalone open-source tool, OPERA, which allows predictions of new and untested chemicals to be made.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

ATcT — Active Thermochemical Tables Python Interface

SF-25-140 atct is a lightweight, Python client for the ATcT v1 API that enables programmatic access to high-accuracy thermochemical data and turnkey reaction-enthalpy analysis. The package implements full v1 endpoint coverage (species lookup by ATcT ID, name, formula, SMILES, InChI, CAS RN; covariance queries; health checks) with robust error handling, retries, and environment-based configuration for local/production endpoints. Beyond data retrieval, atct provides rigorously implemented reaction calculators that propagate uncertainties via either (i) a conventional independent-errors method (0 K or 298.15 K) or (ii) covariance-aware propagation using provided covariances at 298.15 K. Typed data classes ensure transparent, reproducible data structures and carry ATcT Thermochemical Network (TN) version identifiers for provenance. Dual import paths and comprehensive examples facilitate integration into research pipelines, enabling reproducible thermochemical calculations, automated validation, and downstream method development.

Bross, DavidHamilton [Argonne National Laboratory ↗

Scalable High-Throughput Open-Air Spray-Plasma Manufacturing of Solid-State Lithium Batteries

This final technical report presents a comprehensive analysis of a novel plasma-based in-line manufacturing process for large-area, LLZO-separator-based, solid-state lithium-ion batteries, demonstrating both technical feasibility and economic advantages over conventional vacuum deposition methods. The technical validation shows that spray-deposition with plasma curing achieves comparable electrode and separator quality to vacuum techniques while enabling continuous processing of components and industrially relevant film areas. Critical material interfaces maintain low porosity and high ionic conductivities, which confirm the process's ability to overcome the primary limitation of conventional methods - the trade-off between deposition quality and economically-viable production scale.

25 ENERGY STORAGE↗

Lifetime measurements of excited states in 15 O

The CNO cycle is the main energy source in stars more massive than our Sun, it defines the energy production and the cycle time that lead to the lifetime of massive stars, and it is an important tool for the determination of the age of globular clusters. One of the largest uncertainties in the CNO chain of reactions comes from the uncertainty in the 14 N(p,γ) 15 O reaction rate. This uncertainty arises predominantly from the uncertainty in the lifetime of the subthreshold state in 15 O at E x = 6792 keV. Previous measurements of this state's lifetime are significantly discrepant. Here, we report on a new lifetime measurement of this state, as well as the excited states in 15 O at E x = 5181 keV and E x = 6172 keV, populated via the 14 N(p,γ) 15 O reaction at proton energies of E p = 1020 keV and E p = 1570 keV. Furthermore, the lifetimes have been determined with the Doppler-Shift Attenuation Method (DSAM) with three separate, nitrogen-implanted targets with Mo, Ta, and W backing. We obtained lifetimes from the weighted average of the three measurements, allowing us to account for systematic differences between the backing materials. For the 6792 keV state, we obtained a τ = 0.6 ± 0.4 fs. To provide cross-validation of our method, we measured the known lifetimes of the states at 5181 and 6172 keV to be τ = 7.5 ± 3.0 and τ = 0.7 ± 0.5 fs, respectively, in good agreement with previous measurements.

6 ≤ A ≤ 19↗

Battery Charge Curve Prediction via Feature Extraction and Supervised Machine Learning

Real-time onboard state monitoring and estimation of a battery over its lifetime is indispensable for the safe and durable operation of battery-powered devices. In this study, a methodology to predict the entire constant-current cycling curve with limited input information that can be collected in a short period of time is developed. A total of 10 066 charge curves of LiNiO 2 -based batteries at a constant C-rate are collected. With the combination of a feature extraction step and a multiple linear regression step, the method can accurately predict an entire battery charge curve with an error of < 2% using only 10% of the charge curve as the input information. The method is further validated across other battery chemistries (LiCoO 2 -based) using open-access datasets. The prediction error of the charge curves for the LiCoO 2 -based battery is around 2% with only 5% of the charge curve as the input information, indicating the generalization of the developed methodology for predicting battery cycling curves. The developed method paves the way for fast onboard health status monitoring and estimation for batteries during practical applications.

25 ENERGY STORAGE↗

Development of a BISON validation case for the TRISO transient irradiations in NSRR using effective heat capacity methods

The current tristructural isotropic (TRISO) fuel assessment and validation database in BISON primarily covers steady- state irradiation and high-temperature furnace testing. Transient assessment cases are potentially needed to support U.S. industry efforts in designing and deploying commercial reactors using TRISO fuels. Historical transient tests in- volving TRISO fuels used highly conservative conditions compared to the typical high-temperature gas-cooled reactor accident scenarios. Despite this, modeling historical transient tests is fundamental for evaluating BISON’s predictive capabilities, adapting material properties for high-temperature and high-particle-power regimes, and developing a sys- tematic validation approach for TRISO transient applications. This work developed a 1D model of transient experiments carried out at the Nuclear Safety Research Reactor using BISON. BISON’s predictions of energy deposition, UO 2 melting onset, and molten volume fractions are compared against experimental measurements. Melting was modeled using an effective specific heat capacity model for UO 2 . We found that BISON’s predictions are in reasonable agreement with experimental data for low-energy-deposition cases, and that BISON overpredicts melting at higher energy depositions. We also discuss the potential causes of discrepancies between the simulated and measured results and propose ways to further develop the model. Although these simulations used conservative conditions compared to those expected for actual TRISO-fueled reactors, they extended the range of conditions reflected in the data in the existing BISON database for TRISO fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Too Good to Be True? Evaluation of Colonoscopy Sensitivity Assumptions Used in Policy Models

Background: Models can help guide colorectal cancer screening policy. Although models are carefully calibrated and validated, there is less scrutiny of assumptions about test performance. Methods: We examined the validity of the CRC-SPIN model and colonoscopy sensitivity assumptions. Standard sensitivity assumptions, consistent with published decision analyses, assume sensitivity equal to 0.75 for diminutive adenomas (<6 mm), 0.85 for small adenomas (6–10 mm), 0.95 for large adenomas (≥10 mm), and 0.95 for preclinical cancer. We also selected adenoma sensitivity that resulted in more accurate predictions. Targets were drawn from the Wheat Bran Fiber study. In the study, we examined how well the model predicted outcomes measured over a three-year follow-up period, including the number of adenomas detected, the size of the largest adenoma detected, and incident colorectal cancer. Results: Using standard sensitivity assumptions, the model predicted adenoma prevalence that was too low (42.5% versus 48.9% observed, with 95% confidence interval 45.3%–50.7%) and detection of too few large adenomas (5.1% versus 14.% observed, with 95% confidence interval 11.8%–17.4%). Predictions were close to targets when we set sensitivities to 0.20 for diminutive adenomas, 0.60 for small adenomas, 0.80 for 10- to 20-mm adenomas, and 0.98 for adenomas 20 mm and larger. Conclusions: Colonoscopy may be less accurate than currently assumed, especially for diminutive adenomas. Alternatively, the CRC-SPIN model may not accurately simulate onset and progression of adenomas in higher-risk populations. Impact: Misspecification of either colonoscopy sensitivity or disease progression in high-risk populations may affect the predicted effectiveness of colorectal cancer screening. When possible, decision analyses used to inform policy should address these uncertainties.

60 APPLIED LIFE SCIENCES↗

Efficient general method for numerically modeling laser pulse propagation, overlap, and lifetime effects in amplifiers

An efficient numerical time-dependent general method is developed to address incoherent pulse overlap and lifetime effects in laser amplifiers. The alternating propagation-population laser energetics method (APPLE) has been validated against a semi-discrete coupled rate equation numerical method (SDRE) and analytic formalisms in bounding cases. APPLE is based on decoupled rates applied to a time-dependent framework where both space-time-dependent populations and pulse energetics are consistently updated in each time step. A significant advantage of APPLE lies in its conceptual simplicity, ease of implementation, and relatively small computational cost. SDRE tracks the populations through coupled rates and uses the method of lines to discretize the hyperbolic partial differential transport equations allowing for use of ordinary differential equation solvers. With reasonably sized mesh, we report both energetic and power pulse shape relative differences on the order of one percent between the models over a large range of initial conditions.

47 OTHER INSTRUMENTATION↗

DeepONet-grid-UQ: A trustworthy deep operator framework for predicting the power grid’s post-fault trajectories

This paper proposes a novel data-driven method for the reliable prediction of the power grid’s post-fault trajectories, i.e., the power grid’s dynamic response after a disturbance or fault. Here, the proposed method is based on the recently proposed concept of Deep Operator Networks (DeepONets). Unlike traditional neural networks that learn to approximate functions, DeepONets are designed to approximate nonlinear operators, i.e., mappings between infinite-dimensional spaces. Under this operator framework, we design a novel and efficient DeepONet that (i) takes as inputs the trajectories collected before and during the fault and (ii) outputs the predicted post-fault trajectories. In addition, we endow our method with the much-needed ability to balance efficiency with reliable/trustworthy predictions via uncertainty quantification. To this end, we propose and compare two novel methods that enable quantifying the predictive uncertainty. First, we propose a Bayesian DeepONet (B-DeepONet) that uses stochastic gradient Hamiltonian Monte-Carlo to sample from the posterior distribution of the DeepONet trainable parameters. Then, we design a Probabilistic DeepONet (Prob-DeepONet) that uses a probabilistic training strategy to enable quantifying uncertainty at virtually no extra computational cost. Finally, we validate the proposed methods’ predictive power and uncertainty quantification capability using the New York-New England power grid model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

Analytical and Performance-Based Evaluation Alternatives to Full-Scope, High-Fidelity Testbeds

One consequence the design and operational differences of advanced reactors is that integrated system validation (ISV) using full-scope, high-fidelity testbed might not be cost-justified or practical. The absence of traditional ISV may pose an issue for the conduct of safety evaluations since it may leave regulators without the information derived from this performance-based testing. The purpose of this research is to identify analytical and performance-based test and evaluation methods that are alternatives to full-scope, high-fidelity testbeds that have traditionally been used for ISV. We developed a method to test validation based on a multi-stage validation (MSV) framework. MSV is an approach to meeting validation objectives through incremental, successive validation activities beginning in the early stages of the design process and continuing through the later stages. MSV doesn't rely solely on late stage validation, rather it accommodates the use of a broad spectrum of analytical and performance-based information and a diversity of testbeds. In addition, MSV embraces the use of information from other types of evaluations and analyses.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Deterministic Multivariate Clustering Method for Drive Cycle Generation from In-Use Vehicle Data

Accurately characterizing vehicle drive cycles plays a fundamental role in assessing the performance of new vehicle technologies. Repeatable, short duration representative drive cycles facilitate more informed decision making, resulting in improved test procedures and more successful vehicle designs. With continued growth in the deployment of onboard telematics systems employing global positioning systems (GPS), large scale, low cost collection of real-world vehicle drive cycle data has become a reality. As a result of these technological advances, researchers, designers, and engineers are no longer constrained by lack of operating data when developing and optimizing technology, but rather by resources available for testing and simulation. Experimental testing is expensive and time consuming, therefore the need exists for a fast and accurate means of generating representative cycles from large volumes of real-world driving data. This paper explores the development and initial validation of a method of generating representative drive cycles from large collections of real-world vehicle data using a deterministic multivariate clustering approach. Starting with theory and diving into the methodology behind representative cycle generation, the paper aims to also present graphical and tabular results of initial validation via vehicle simulation and chassis dynamometer testing. Additional topics for further research and areas for ongoing development will also be presented.

47 OTHER INSTRUMENTATION↗

Minimizing Fraud in the Carbon Offset Market Using Blockchain Technologies

Fraud in the Environmental Benefit Credit (EBC) markets is pervasive. To make matters worse, the cost of creating EBCs is often higher than the market price. Consequently, a method to create, validate, and verify EBCs and their relevance is needed to mitigate fraud. The EBC market has focused on geologic (fossil fuel) CO 2 sequestration projects that are often over budget and behind schedule and has failed to capture the "lowest hanging fruit" EBCs - terrestrial sequestration via the agricultural industry. This project reviews a methodology to attain possibly the least costly EBCs by tracking the reduction of inputs required to grow crops. The use of bio- stimulant products, such as humate, allows a farmer to use less nitrogen without adversely affecting crop yield. Using less nitrogen qualifies for EBCs by reducing nitrous oxide emissions and nitrate runoff from a farmer's field. A blockchain that tracks the bio-stimulant material from source to application provides a link between a tangible (bio-stimulant commodity) and the associated intangible (EBCs) assets. Covert insertion of taggants in the bio-stimulant products creates a unique barcode that allows a product to be digitally tracked from beginning to end. This process (blockchain technology) is so robust, logical, and transparent that it will enhance the value of the associated EBCs by mitigating fraud. It provides a real time method for monetizing the benefits of the material. Substantial amounts of energy are required to produce, transport, and distribute agricultural inputs including fertilizer and water. Intelligent optimization of the use of agricultural inputs can drive meaningful cost savings. Tagging and verification of product application provides a valuable understanding of the dynamics in the water/food energy nexus, a major food security and sustainability issue. As technology in agriculture evolves so to must methods to verify the Enterprise Resource Planning (ERP) potential of innovative solutions. The technology reviewed provides the ability to combine blockchain and taggants ("taggant blockchains") as the engine by which to (1) mitigate fraudulent carbon credits; (2) improve food chain security, and (3) monitor and manage sustainability. The verification of product quality and application is a requirement to validate benefits. Recent upgrades to humic and fulvic quality protocols known as ISO CD 19822 TC134 offers an analytical procedure. This work has been assisted by the Humic Products Trade Association and International Humic Substance Society. In addition, providing proof of application of these products and verification of the correct application of prescriptive humic and bio-stimulant products is required. Individual sources of humate have unique and verifiable characteristics. Additionally, methods for prescription of site- specific agricultural inputs in agricultural fields are available. (See US Patents 734867B2, US 90658633B2.) Finally, a method to assure application rate is required through the use of taggants. Sensors using organic solid to liquid phase change nanoparticles of various types and melting temperatures added to the naturally occurring materials provide a barcode. Over 100 types of nanoparticles exist ensuring numerous possible barcodes to reduce industry fraud. Taggant materials can be collected from soil samples of plant material to validate a blockchain of humic, fulvic and other soil amendment products. Other non-organic materials are also available as taggants; however, the organic tags are biodegradable and safe in the environment allowing for use during differing application timeliness.

54 ENVIRONMENTAL SCIENCES↗