Search NASA⌕ Search

SEARCH · Search NASA

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Dynamic modelling and control strategy of a temperature-driven metal hydride cooling system for buildings

A temperature-driven coupled metal hydride (MH) based thermal energy storage (TES) system can allow to shave and shift the peak energy demand in buildings. The high energy density and long-term (seasonal) energy storage capability are its major advantages over other energy storage methods. The dynamic nature of the MH operation, however, requires controlled hydrogen transfer between the coupled MHs at a rate needed to meet the building's transient load. While temperature-driven MH systems are studied in the literature, their application in buildings and control are scarcely reported. Here, this paper presents a control-based dynamic modeling of the temperature-driven coupled MH-TES system for building cooling applications. The dynamic model is developed in MATLAB(R) Simulink environment, considering the thermodynamic and kinetic behaviors of the MH systems. Based on a preliminary analysis of a property database of over 337 hydrides, we select around 1600 MH pairs suitable for building cooling applications. Each of these MH pairs is studied for their performance using the dynamic model, and among all, Zr 0.76 Ti 0.24 Ni 1.16 Mn 0.63 V 0.14 Fe 0.18 -Ti 0.85 Zr 0.15 Cr 1.2 Mn 0.8 MH pair showed fast dynamics along with high coefficient of performance (COP) of 0.71. A parametric investigation is performed on this MH pair to understand the effect of operating temperatures. Finally, three proportional-integral (PI) feedback controllers are investigated to regulate the temperature, pressure and mass exchange between the coupled MH pairs. The developed PI controller is sufficiently capable of rejecting the signal noise from the hydrogen flow and internal heat exchange processes with root mean square error of 5.78 W between reference and actual cooling load.

08 HYDROGEN↗

Heat Recovery System for Domestic Dishwashers (Final Report)

The objectives of this project were to enable commercialization of a patent-pending technology for unprecedented dishwasher energy savings and non-energy consumer benefits. Specific objectives were to (1) provide customer-requested features of more thorough drying, (2) reduce kitchen humidity load (75% target reduction in water vapor released by the dishwasher), (3) introduce the lowest energy consumption domestic dishwasher on the market with 30% less energy consumption than that of the current best in market, and (4) maintain high cleaning performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opportunity Assessment for U.S. Industry: Energy-Efficient Cooling Technologies in Mexico

Mexico's rapidly expanding room air conditioner (AC) market presents a strategic opportunity for U.S. manufacturers to strengthen North American supply chains while addressing critical energy infrastructure challenges. With demand for room AC units in residential and commercial buildings projected to drive a 26 GW increase in Mexico’s peak electrical load by 2050, high-efficiency air conditioning systems offer both substantial market opportunities and essential grid stability benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

A visco-plastic framework for interface processes in sedimentary reservoir rocks at HPHT conditions

As energy operations face the challenge of reservoirs at ever-increasing depths, modelling the response of reservoir rocks at high pressure and high temperature (HPHT) conditions is a crucial step for successfully unlocking new resources. At these conditions, rocks can experience thermal and pressure sensitivity, as well as admit internal phase changes at the pore-solid interfaces that determine their macroscopic response to external loading. It is therefore expected that constitutive laws of Geomechanics should be enriched to accommodate such effects. In this work, a multi-physics constitutive theory for sedimentary rocks is proposed within the general framework of viscoplasticity. The viscosity of the material is assumed to be a function of the temperature, pore-pressure and energy required to alter the inter-granular interfaces. This energy is expressed through the chemical potentials of the phases involved during processes like chemical dissolution/precipitation of the interfaces or mechanical debonding. The resulting flow law and corresponding stress equilibrium are coupled to the energy and mass conservation laws, constituting a closed system of equations, which is solved using the Finite Element simulator REDBACK. A series of numerical tests for performance and calibration is then successfully performed against different types of reservoir rocks, confining pressures and temperatures (from room temperature to over 800K). Here, we show that the mechanical response of sedimentary porous rocks at strains usually achieved in laboratory testing can be explained by accounting for the interface processes taking place at the cementitious material bonding the grains, a process that can also determine the brittle-to-ductile transition of sedimentary rocks.

58 GEOSCIENCES↗

Reinforcement-Learning-Based Smart Water Heater Control: An Actual Deployment

Utilizing smart control algorithms for electric water heaters (EWHs) is essential for fully harnessing the demand response (DR) potential of EWHs. For this reason, the use of reinforcement learning (RL) algorithms for EWHs has received increasing attention in recent years. However, existing RL approaches are either simulation-based or use pretrained RL agents. To this end, this paper presents the real-world deployment of a set of model-free RL approaches that aim to minimize the electricity cost of a EWH under a time-of-use electricity pricing policy using standard DR commands (e.g., shed, load up). The experiment results showed that the RL agents can help save electricity cost in the range of 11% to 14% compared to the baseline operation. This study demonstrated that RL-based EWH controllers can be deployed in real world without any prior training and can still save electricity cost.

deep learning↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing microgrid availability to reduce costs for coastal Puerto Rican communities

Renewable microgrids are sustainable, resilient solutions to mitigate and adapt to climate change. Making electric loads nearly 100% available (i.e., power remains on) during outages increases cost. Near 100% availability is required when human life or high-cost assets are involved, but availability can be reduced for less consequential loads leading to lower costs. This study analyses costs for photo-voltaic and lithium-ion battery microgrids with availability ranging from 0–99%. We develop a methodology to analyse three Puerto Rican coastal communities. Here, we consider power outage effects for hurricanes, earthquakes, and everyday outages. The results show cost versus availability from 0–99%. There is 27–31% cost reduction at 80% availability in comparison to 99% availability. A regression model of microgrid availability versus three ratios: 1) the annual generation to demand ratio, 2) storage to interruption energy ratio, and 3) peak storage to load ratio produced a coefficient of determination of 0.99949 with 70% of the data used for training and 30% for testing. The results can therefore be extended to other coastal Puerto Rican communities of varying sizes that have ratios within the ranges analysed in this study. This can empower decision makers to rapidly analyse designs that have availabilities well below 100%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design by analysis rules for ASME Section III, Division 5, Class B components

The current rules for elevated temperature ASME Section III, Division 5, Class B components, other than piping, were basically adapted from the Design-by-Rule approach for Section VIII, Division 1 vessels. A goal of the proposed new rules is to explicitly account for the design life and cyclic service while recognizing the less-rigorous requirements commensurate with lesser safety consideration. Further goals are to maximize the use of modern computational technology, for example finite element analysis in conjunction with reference stress concepts, and to avoid the need for stress classification. This paper summarizes the work done to address these issues. A summary of the design-by-analysis for primary loads, strain limit evaluation, and creep-fatigue damage assessment is presented. The proposed design-by-analysis creep-fatigue damage calculation approach uses a new elastic follow-up-based Isochronous Stress Strain Curve stress relaxation procedure. A set of sample problems are selected to validate the proposed design-by-analysis rules for creep-fatigue damage assessment. The proposed Class B rules are evaluated against the Class A elastic design rules and the experimental data obtained from a family of a simplified model test-based key-feature test results. The proposed Class B creep-fatigue damage assessment methodology yields conservative design cycles estimates compared to the experimental results.

36 MATERIALS SCIENCE↗

The Demand-Side Opportunity: The Roles of Distributed Solar and Building Energy Systems in a Decarbonized Grid

Building energy systems represent a significant and largely untapped demand-side grid resource. Buildings use about 75% of electricity in the United States, including around 80% of peak demand, meaning that changes in building energy use have significant implications for grid operations. Building energy technologies-including energy-efficient devices, flexible loads, and energy storage-can be coordinated and aggregated to perform similar functions as centralized grid assets. Recent advances in information and communication (ICT) technologies have significantly improved building energy technology automation, coordination, and aggregation capabilities. With declining costs and technological advances, building energy systems can increasingly compete with conventional grid assets such as natural gas plants. Building energy technologies enable the deployment of distributed solar photovoltaics (DPV). Energy-efficient buildings allow DPV to meet greater shares of building load while flexible loads and energy storage can reshape building load profiles to optimize the on-site use of DPV. Optimized on-site use of DPV increases the value proposition for DPV adoption and can help utilities cost-effectively integrate higher levels of DPV penetration. Together, DPV and building energy technologies could help grids achieve deep decarbonization more quickly and cost-effectively.

14 SOLAR ENERGY↗

Functional Assessment of Shell Recharge Solutions' SKY™ Platform OpenADR Capability

The project’s overall objective is to research, develop, and conduct a wide-scale demonstration of a utility smart charge management (SCM) system to develop optimal managed charging structures for grid value, evaluate the impact of EV charging on local distribution utility operations, and evaluate the utilities’ ability to control electronic vehicle (EV) charging load based on grid conditions. This report covers Argonne’s validation testing in the first period of the project, the objective of which was to determine the current managed charging functionality of the EVSE hardware, the network and the vehicle telematics software solution and understand gaps that need to be addressed prior to a large-scale demonstration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Forecasting Commercial Building Electricity Consumption, Zone Airflow and Zone Temperature: Update - Development of a Generalized Machine Learning Approach

The U.S. power grid is being transformed to make it smarter, more efficient, and cleaner. This transformation is leading to the addition of a significant of energy generated by distributed, variable, and renewable resources. Because of the variable nature of renewable generation, the short- and long-term supply and demand imbalances are less predictable, and conventional approaches to mitigating the imbalances will be less efficient or cost effective. To address this challenge and to support the mission and the vision of the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) Building Technologies Office has developed a Grid-Interactive Efficient Building Strategy. The strategy focuses on simultaneously improving building energy efficiency and supporting reliability and resilience of the electric grid more efficiently and at a lower cost. In addition, EERE and DOE’s Office of Electricity created an initiative led by DOE and supported by the national laboratories under the Grid Modernization Lab Consortium structure to enhance grid modernization. The work reported in this document is part of the first set of projects funded under the initiative to design, develop, and validate scalable transactive control technologies for the commercial buildings sector. Transactive controls requires the ability of individual end-use loads to express flexibility as a function of a transactive signal (e.g., price). Empirical grey- and black-box models have been widely used to express flexibility. Although this approach is generally easy to construct and simple to use, it does not capture non-linear behavior that some end-use loads represent. Therefore, Pacific Northwest National Laboratory (PNNL) with support from Western Washington University conducted this research to explore the use of deep machine learning (ML) techniques. The work reported in this document is limited to forecasting whole building electricity consumption, the zone airflow and the zone temperature predictions.

24 POWER TRANSMISSION AND DISTRIBUTION↗