Search NASA⌕ Search

SEARCH · Search NASA

Results for “deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Single crystal growth and structure refinements of CsM{sub x}Te{sub 2-x}O{sub 6} (M = Al, Ga, Ge, In) pyrochlores

Graphical abstract: Single crystals of CsM{sub x}Te{sub 2-x}O{sub 6} pyrochlores with M = Al, Ga, Ge, and In have been grown and structure refinements indicate deviations from ideal stoichiometry presumably related to mixed valency of tellurium. Highlights: {yields} Single crystals of CsM{sub x}Te{sub 2-x}O{sub 6} pyrochlores with M = Al, Ga, Ge, and In have been grown. {yields} Structure refinements from single crystal X-ray diffraction data confirm e structure. {yields} Deviations from ideal stoichiometry suggest mixed valency of tellurium and hence conductivity. -- Abstract: Single crystals of CsM{sub x}Te{sub 2-x}O{sub 6} pyrochlores with M = Al, Ga, Ge, and In have been grown from a TeO{sub 2} flux. Structure refinements from single crystal X-ray diffraction data are reported. These results are used to discuss deviations from ideal stoichiometry that result in electronic conductivity presumably related to mixed valency of tellurium.

36 MATERIALS SCIENCE↗

An Optimized Online Verification Imaging Procedure for External Beam Partial Breast Irradiation

The purpose of this study was to evaluate the capabilities of a kilovoltage (kV) on-board imager (OBI)-equipped linear accelerator in the setting of on-line verification imaging for external-beam partial breast irradiation. Available imaging techniques were optimized and assessed for image quality using a modified anthropomorphic phantom. Imaging dose was also assessed. Imaging techniques were assessed for physical clearance between patient and treatment machine using a volunteer. Nonorthogonal kV image pairs were identified as optimal in terms of image quality, clearance, and dose. After institutional review board approval, this approach was used for 17 patients receiving accelerated partial breast irradiation. Imaging was performed before every fraction verification with online correction of setup deviations >5 mm (total image sessions = 170). Treatment staff rated risk of collision and visibility of tumor bed surgical clips where present. Image session duration and detected setup deviations were recorded. For all cases, both image projections (n = 34) had low collision risk. Surgical clips were rated as well as visualized in all cases where they were present (n = 5). The average imaging session time was 6 min, 16 sec, and a reduction in duration was observed as staff became familiar with the technique. Setup deviations of up to 1.3 cm were detected before treatment and subsequently confirmed offline. Nonorthogonal kV image pairs allowed effective and efficient online verification for partial breast irradiation. It has yet to be tested in a multicenter study to determine whether it is dependent on skilled treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments

The recalculation of 1 fraction from a patient treatment plan on a phantom and subsequent measurements have become the norms for measurement-based verification, which combines the quality assurance recommendations that deal with the treatment planning system and the beam delivery system. This type of evaluation has prompted attention to measurement equipment and techniques. Ionization chambers are considered the gold standard because of their precision, availability, and relative ease of use. This study evaluates and compares 5 different ionization chambers: phantom combinations for verification in routine patient-specific quality assurance of RapidArc treatments. Fifteen different RapidArc plans conforming to the clinical standards were selected for the study. Verification plans were then created for each treatment plan with different chamber-phantom combinations scanned by computed tomography. This includes Medtec intensity modulated radiation therapy (IMRT) phantom with micro-ionization chamber (0.007 cm{sup 3}) and pinpoint chamber (0.015 cm{sup 3}), PTW-Octavius phantom with semiflex chamber (0.125 cm{sup 3}) and 2D array (0.125 cm{sup 3}), and indigenously made Circular wax phantom with 0.6 cm{sup 3} chamber. The measured isocenter absolute dose was compared with the treatment planning system (TPS) plan. The micro-ionization chamber shows more deviations when compared with semiflex and 0.6 cm{sup 3} with a maximum variation of -4.76%, -1.49%, and 2.23% for micro-ionization, semiflex, and farmer chambers, respectively. The positive variations indicate that the chamber with larger volume overestimates. Farmer chamber shows higher deviation when compared with 0.125 cm{sup 3}. In general the deviation was found to be <1% with the semiflex and farmer chambers. A maximum variation of 2% was observed for the 0.007 cm{sup 3} ionization chamber, except in a few cases. Pinpoint chamber underestimates the calculated isocenter dose by a maximum of 4.8%. Absolute dose measurements using the semiflex ionization chamber with intermediate volume (0.125 cm{sup 3}) shows good agreement with the TPS calculated among the detectors used in this study. Positioning is very important when using smaller volume chambers because they are more sensitive to geometrical errors within the treatment fields. It is also suggested to average the dose over the sensitive volume for larger-volume chambers. The ionization chamber-phantom combinations used in this study can be used interchangeably for routine RapidArc patient-specific quality assurance with a satisfactory accuracy for clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning

Monte Carlo (MC) simulation is currently the most accurate dose calculation algorithm in radiotherapy planning but requires relatively long processing time. Faster model-based algorithms such as the anisotropic analytical algorithm (AAA) by the Eclipse treatment planning system and multigrid superposition (MGS) by the XiO treatment planning system are 2 commonly used algorithms. This study compared AAA and MGS against MC, as the gold standard, on brain, nasopharynx, lung, and prostate cancer patients. Computed tomography of 6 patients of each cancer type was used. The same hypothetical treatment plan using the same machine and treatment prescription was computed for each case by each planning system using their respective dose calculation algorithm. The doses at reference points including (1) soft tissues only, (2) bones only, (3) air cavities only, (4) soft tissue-bone boundary (Soft/Bone), (5) soft tissue-air boundary (Soft/Air), and (6) bone-air boundary (Bone/Air), were measured and compared using the mean absolute percentage error (MAPE), which was a function of the percentage dose deviations from MC. Besides, the computation time of each treatment plan was recorded and compared. The MAPEs of MGS were significantly lower than AAA in all types of cancers (p<0.001). With regards to body density combinations, the MAPE of AAA ranged from 1.8% (soft tissue) to 4.9% (Bone/Air), whereas that of MGS from 1.6% (air cavities) to 2.9% (Soft/Bone). The MAPEs of MGS (2.6%±2.1) were significantly lower than that of AAA (3.7%±2.5) in all tissue density combinations (p<0.001). The mean computation time of AAA for all treatment plans was significantly lower than that of the MGS (p<0.001). Both AAA and MGS algorithms demonstrated dose deviations of less than 4.0% in most clinical cases and their performance was better in homogeneous tissues than at tissue boundaries. In general, MGS demonstrated relatively smaller dose deviations than AAA but required longer computation time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric-modulated arc radiotherapy for pancreatic malignancies: Dosimetric comparison with sliding-window intensity-modulated radiotherapy and 3-dimensional conformal radiotherapy

Volumetric-modulated arc radiotherapy (VMAT) is an iteration of intensity-modulated radiotherapy (IMRT), both of which deliver highly conformal dose distributions. Studies have shown the superiority of VMAT and IMRT in comparison with 3-dimensional conformal radiotherapy (3D-CRT) in planning target volume (PTV) coverage and organs-at-risk (OARs) sparing. This is the first study examining the benefits of VMAT in pancreatic cancer for doses more than 55.8 Gy. A planning study comparing 3D-CRT, IMRT, and VMAT was performed in 20 patients with pancreatic cancer. Treatments were planned for a 25-fraction delivery of 45 Gy to a large field followed by a reduced-volume 8-fraction external beam boost to 59.4 Gy in total. OARs and PTV doses, conformality index (CI) deviations from 1.0, monitor units (MUs) delivered, and isodose volumes were compared. IMRT and VMAT CI deviations from 1.0 for the large-field and the boost plans were equivalent (large field: 0.032 and 0.046, respectively; boost: 0.042 and 0.037, respectively; p > 0.05 for all comparisons). Both IMRT and VMAT CI deviations from 1.0 were statistically superior to 3D-CRT (large field: 0.217, boost: 0.177; p < 0.05 for all comparisons). VMAT showed reduction of the mean dose to the boost PTV (VMAT: 61.4 Gy, IMRT: 62.4 Gy, and 3D-CRT: 62.3 Gy; p < 0.05). The mean number of MUs per fraction was significantly lower for VMAT for both the large-field and the boost plans. VMAT delivery time was less than 3 minutes compared with 8 minutes for IMRT. Although no statistically significant dose reduction to the OARs was identified when comparing VMAT with IMRT, VMAT showed a reduction in the volumes of the 100% isodose line for the large-field plans. Dose escalation to 59.4 Gy in pancreatic cancer is dosimetrically feasible with shorter treatment times, fewer MUs delivered, and comparable CIs for VMAT when compared with IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of deformed image-based dose calculations for adaptive radiotherapy of nasopharyngeal carcinoma

The ultimate goal of adaptive radiotherapy (ART) is to deliver truly customized radiation treatments. Currently, the quality of cone-beam computed tomography (CBCT) images is still inferior to that of conventional CT images in contour delineations and dose calculations for replanning purposes. This retrospective study aims to evaluate the dosimetric accuracy of using deformed conventional CT images for dose calculations, in the hope of inferring the feasibility of ART using planning CT (PCT) images that deformed to up-to-date CBCT images for patients with nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC who had undergone 1 replan in their radiotherapy treatments were selected. The pretreatment PCT images were deformed to match the mid-treatment PCT images by deformable image registration. The same volumetric modulated arc therapy plan was then calculated on the deformed PCT images. The resulting dose distributions and dose volume histograms of the tumors and organs at risk (OARs) were compared with the original plan. Five dose levels, D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%}, were recorded for 9 NPC targets. Four dose levels, D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean}, were recorded for 15 OARs. The greatest percentage difference in observed dose for D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%} of the targets were 1.71%, 1.55%, 0.64%, 0.97%, and 1.13%, respectively. The greatest percentage difference in observed dose for D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean} of the OARs were -26.51% (left optic nerve), -17.06% (left optic nerve), 56.70% (spinal cord), and 18.97% (spinal cord), respectively. In addition, 29 of 45 (64%) dosimetric end points of the targets showed statistically significant dose differences (p p < 0.05). Dose calculations using deformed PCT images could result in significant dose uncertainties in target volumes and OARs. Larger dose deviations were found in OARs in comparison with target volumes. The spinal cord and optic nerve showed the greatest percentage dose differences and the clinical significance has yet to be determined. Deformable registration error was believed to be the problem causing the dose deviations. Owing to unknown clinical significanceof dose deviation results obtained from this study, a conventional CT scan is still required for replanning in patients with NPC who are experiencing significant anatomical changes during the course of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermophysical Properties of Alloy 617 from 25°C to 1000°C

Key thermophysical properties needed for the successful design and use of Alloy 617 in steam generator and heat exchanger applications have been measured experimentally, and results are compared with literature values and results obtained from some other commercial Ni–Cr alloys and model materials. Specifically, the thermal diffusivity, thermal expansion coefficient, and specific heat capacity have been measured for Alloy 617 over a range of temperatures, allowing calculation of thermal conductivity up to 1000 degrees C. It has been found that the thermal conductivity of Alloy 617 exhibits significant deviation from monotonic behavior in the temperature range from 600 degrees C to 850 degrees C, the temperatures of interest for most heat transfer applications. The non-linear behavior appears to result primarily from short-range order/disorder phenomena known to occur in the Ni–Cr system. Similar deviation from monotonic behavior was observed in the solid solution Ni–Cr-W Alloy 230, and lesser deviations were observed in iron based Alloy 800H and an austenitic stainless steel. Measured thermophysical property data are provided for four different heats of Alloy 617, and it is shown that property variations between the four different heats are not significant. Measurements were also obtained from Alloy 617 that was aged for up to 2000 h at 750 degrees C, and it was found that this aging treatment does not significantly influence the thermophysical properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New Measurements of the Proton Electromagnetic Form Factor Ratio at Low

Polarization measurements are allowing the electric to magnetic form factor ratio of the proton to be determined with unprecedented precision. Recent results indicate that there is a large deviation from unity in the proton form factor ratio around Q2similar, equals0.35 GeV2. Furthermore, the deviation from unity is attributed to a deviation of the electric form factor from standard fits and calculations. A new, partially completed, experiment will significantly improve the existing data and will determine the presence, if any, of a narrow structure in the form factor ratio. The new measurement, combined with the expected high precision cross section measurements, will allow the extraction of individual form factors with unprecedented accuracy at low Q2.

Ron, G.↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

2-D soil zymography: Accounting for the spatial variation of pH

Soil zymography is commonly used to quantify spatial distribution of hydrolytic enzyme activities on soil and plant root surfaces. It is recommended to adjust pH in zymography substrates and calibration solutions with respect to soil/root pH. However, pH values may vary greatly within a few mm of plant rhizosphere, potentially altering the distribution of pH in zymography membranes. Despite the fact that the effect of pH on the calibration of zymography membranes is generally known, its potential impact on zymography results is unaccounted for in processing zymography images and calculations of enzyme activity. In this study we assessed the effect of pH variations on the persistency of the methylumbelliferone (MUF) calibration. The studied pH values ranged from 4.5 to 7.5. The MUF calibration curves greatly deviated from that at a reference pH of 6.5, with a marked nonlinear increase of deviation with greater membrane brightness. We suggest that the problem can be partially alleviated by reducing the membrane incubation time. However, such deviations suggest the need for a more comprehensive resolution via mapping pH and using pH-specific calibrations to process zymography images. Here, we developed a MATLAB code to implement a pixel-based correction of enzyme activity for pH in processing time-lapse zymography images.

59 BASIC BIOLOGICAL SCIENCES↗

An automated micro-separation system for the chromatographic removal of uranium matrix for trace element analysis by ICP-OES

An automated, miniaturized, off-line separation technique is presented here using an Elemental Scientific Inc. microFAST MC system with UTEVA resin to extract the uranium matrix from its trace element impurities in aqueous media. The collected fractions were analyzed for ~30 trace elements using inductively coupled plasma – optical emission spectroscopy. Ten replicate samples were processed with a single column resulting in precision ranging from 3.3% to 6.2% relative standard deviation with regards to the trace element recoveries. Accuracy, with respect to trace element concentrations in the U 3 O 8 Certified Reference Material 124-1, resulted in an average of 13.9% relative deviation while accuracy to the Canadian U3O8 reference material, CUP-2, resulted in an average relative deviation of 8.6%. In conclusion, the total separation time of this automated process was reduced to ~30 min per sample while employing a 0.5 mL UTEVA chromatographic resin bed and 2.5 mg of uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deriving Material Properties from Feedback Error Signals in Scanning Tunneling Microscopy

Imperfections in measurements, e.g., deviations and broadening, are not devoid of information; rather, they can reveal valuable physical properties and processes. Scanning tunneling microscopy leverages a negative feedback loop to regulate the tunneling current. Practically, current fluctuates around its set point, and such deviations are considered insignificant and ignored. Here, in this study, we investigate the information embedded in these deviations. In the constant-current mode with an active feedback loop, we observe an unexpected persistent DC current offset from its set point when the tunneling junction is periodically perturbed. We demonstrate both experimentally and theoretically that such error signals encode local tunneling barrier heights and the square of local differential conductance as a consequence of the interplay between rectification and active feedback compensation. We provide evidence on the generalizability of this phenomenology to other negative feedback systems. This new approach has the potential to broadly impact physical sciences by allowing rapid measurements without lock-in amplifiers.

36 MATERIALS SCIENCE↗

Challenges in Modeling Electrochemical Reaction Energetics with Polarizable Continuum Models

A major challenge in the modeling of electrochemical phenomena is the accurate description of the interface between an electrolyte and a charged conductor. Polarizable continuum models (PCM) have been gaining popularity because they offer a computationally inexpensive method of modeling the electrolyte. In this Perspective, we discuss challenges from using one such model which treats the ions using a linearized Poisson–Boltzmann (LPB) distribution. From a physical perspective, this model places charge unphysically close to the surface and adsorbates, and it includes excessively steep ramping of the dielectric constant from the surface to the bulk solvent. Both of these issues can be somewhat mitigated by adjusting parameters built into the model, but in doing so, the resultant capacitance deviates from experimental values. Likewise, hybrid explicit-implicit approaches to the solvent may offer a more realistic description of hydrogen bonding and solvation to reaction intermediates, but the corresponding capacitances also deviate from experimental values. These deviations highlight the need for a careful adjustment of parameters in order to reproduce not only solvation energies but also other physical properties of solid–liquid interfaces. Continuum approaches alone also necessarily do not capture local variations in the electric field from cations at the interface, which can affect the energetics of intermediates with substantial dipoles or polarizability. Finally, since the double-layer charge can be varied continuously, LPB/PCM models provide a way to determine electrochemical barriers at constant potential. However, double-layer charging and the atomic motion associated with reaction events occur on significantly different timescales. As a result, we suggest that more detailed approaches, such as the modified Poisson–Boltzmann model and/or the addition of a Stern layer, may be able to mitigate some but not all of the challenges discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interface and Thermophysical Properties of R 32 Refrigerant

Driven by the urgent demand for efficient cooling in microelectronics and advanced thermal management systems, difluoromethane (R32/CH 2 F 2 ) has emerged as a promising candidate owing to its favorable thermophysical properties, including high heat transfer efficiency and low viscosity. While bulk properties such as density, viscosity, and thermal conductivity have been widely studied, interfacial properties, including surface tension and interfacial thickness, remain comparatively underexplored, despite their importance in phase-transition dynamics. Here, we perform molecular dynamics (MD) simulations from 180 to 300 K using an optimized transferable force field for fluoropropenes with enhanced electrostatics to assess both bulk and interfacial behavior of R32. Simulations reproduced density within ±2.1%, viscosity within 3.05%, and thermal conductivity within 7.41% of NIST reference data. Heat capacities (C p and C v ) were predicted within 5%. For interfacial properties, surface tension trends were reproduced within 13.58% deviation, and the vapor–liquid coexistence curve closely matched reference data, yielding a critical temperature of 345.7 K (1.6% deviation) and a critical density of 0.397 g/cm 3 (6.4% deviation). Importantly, the vapor–liquid interface exhibited pronounced temperature-dependent broadening across the 180–290 K range. This behavior correlates with increasing molecular kinetic energy, reduction in intermolecular cohesive interactions, and a progressive loss of preferential dipole alignment, which collectively enhance thermal fluctuation amplitudes at elevated temperatures. These validated results provide predictive molecular-level insights, particularly for interfacial properties that remain less characterized. By reducing property prediction errors in key parameters such as critical temperature, this work provides reliable inputs for heat-exchanger and system models. Such correlations can support optimized component sizing, improved performance, and reduced refrigerant charge. Beyond R32, the methodology offers a transferable framework for blended and next-generation low-GWP refrigerants, contributing to sustainable thermal management aligned with the 2027 EU F-Gas regulation and 2030 Kigali Amendment.

Fluids↗

Fluorescence Correlation Spectroscopy and Nonlinear Stochastic Reaction-Diffusion

The currently existing theory of fluorescence correlation spectroscopy (FCS) is based on the linear fluctuation theory originally developed by Einstein, Onsager, Lax, and others as a phenomenological approach to equilibrium fluctuations in bulk solutions. For mesoscopic reaction-diffusion systems with nonlinear chemical reactions among a small number of molecules, a situation often encountered in single-cell biochemistry, it is expected that FCS time correlation functions of a reaction-diffusion system can deviate from the classic results of Elson and Magde [Biopolymers (1974) 13:1-27]. We first discuss this nonlinear effect for reaction systems without diffusion. For nonlinear stochastic reaction-diffusion systems there are no closed solutions; therefore, stochastic Monte-Carlo simulations are carried out. We show that the deviation is small for a simple bimolecular reaction; the most significant deviations occur when the number of molecules is small and of the same order. Extending Delbrück-Gillespie’s theory for stochastic nonlinear reactions with rapidly stirring to reaction-diffusion systems provides a mesoscopic model for chemical and biochemical reactions at nanometric and mesoscopic level such as a single biological cell.

Del Razo, Mauricio↗

Varying Contributions of Drivers to the Relationship Between Canopy Photosynthesis and Far‐Red Sun‐Induced Fluorescence for Two Maize Sites at Different Temporal Scales

Abstract Sun‐induced fluorescence (SIF) has been found to be strongly correlated with gross primary production (GPP) in a quasi‐linear pattern at the scales beyond leaves. However, the causes of the GPP:SIF relationship deviating from a linear pattern remain unclear. In the current study conducted at two maize sites in Nebraska in 2017 summer growing season, we investigated the relationship between GPP and SIF at 760 nm (F 760 ) at two temporal scales and quantified the contributions of incoming photosynthetically active radiation (PAR in ), fraction of absorbed PAR (fPAR), light use efficiency (LUE), and F 760 yield (F 760,y , defined as F 760 /(PAR in ×fPAR)) to GPP and F 760 variabilities to further understand the linearity and deviations in the GPP:F 760 relationship. We found the following: (1) For individual growth stages when canopy structure and chlorophyll content were stable, GPP and F 760 were strongly controlled by PAR in , while LUE and F 760,y had much lower contributions to the GPP:F 760 relationship; during this period, LUE and F 760,y had either a slightly negative or no clear relationship, which explained some deviations in the GPP:SIF relationship. (2) At the seasonal scale, the contribution of LUE to GPP variability as well as the contribution of F 760,y to F 760 variability increased and was comparable to the contribution of PAR in ; the LUE:F 760,y relationship showed a strong linear relationship, which strengthened the linear GPP:F 760 relationship. Both maize sites showed similar patterns. A framework was applied to estimate LUE at individual stages and as a result, significantly improved the GPP estimation, thus enhancing the SIF potential for inferring photosynthesis.

Miao, Guofang↗

Dynamics of the human gut microbiome in inflammatory bowel disease

Inflammatory bowel disease (IBD) is characterized by flares of inflammation with periodic need for increased medication and sometimes even surgery. IBD etiology is partly attributed to a deregulated immune response to gut microbiome dysbiosis. Cross-sectional studies have revealed microbial signatures for different IBD diseases, including ulcerative colitis (UC), colonic Crohn’s Disease (CCD), and ileal CD (ICD). Although IBD is dynamic, microbiome studies have primarily focused on single timepoints or few individuals. Here we dissect the long-term dynamic behavior of the gut microbiome in IBD and differentiate this from normal variation. Microbiomes of IBD subjects fluctuate more than healthy individuals, based on deviation from a newly-defined healthy plane (HP). ICD subjects deviated most from the HP, especially subjects with surgical resection. Intriguingly, the microbiomes of some IBD subjects periodically visited the HP then deviated away from it. Inflammation was not directly correlated with distance to the healthy plane, but there was some correlation between observed dramatic fluctuations in the gut microbiome and intensified medication due to a flare of the disease. These results help guide therapies that will re-direct the gut microbiome towards a healthy state and maintain remission in IBD.

gut, human↗