Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Hollow Fiber Membrane Bioreactor Systems for Wastewater Processing: Effects of Environmental Stresses Including Dormancy Cycling and Antibiotic Dosing

Membrane-aerated biofilm reactors (MABRs) have been studied for a number of years as an alternate approach for treating wastewater streams during space exploration. While the technology provides a promising pre-treatment for lowering organic carbon and nitrogen content without the need for harsh stabilization chemicals, several challenges must be addressed before adoption of the technology in future missions. One challenge is the transportation of bioreactors containing intact, active biofilms as a means for rapid start-up on the International Space Station or beyond. Similarly, there could be a need for placing these biological systems into a dormant state for extended periods when the system is not in use, along with the ability for rapid restart. Previous studies indicated that there was little influence of storage condition (4 or 25 C, with or without bulk fluid) on recovery of bioreactors with immature biofilms (48 days old), but that an extensive recovery time was required (20+ days). Bioreactors with fully established biofilms (13 months) were able to recover from a 7-month dormancy within 4 days (approximately 1 residence). Further dormancy and recovery testing is presented here that examines the role of biofilm age on recovery requirements, repeated dormancy cycle capabilities, and effects of long-duration dormancy cycles (8-9 months) on HFMB systems. Another challenge that must be addressed is the possibility of antibiotics entering the wastewater stream. Currently, for most laboratory tests of biological water processors, donors providing urine may not contribute to the study when taking antibiotics because the effects on the system are yet uncharacterized. A simulated urinary tract infection event, where an opportunistic, pathogenic organism, E. coli, was introduced to the HFMBs followed by dosing with an antibiotic, ciprofloxacin, was completed to study the effect of the antibiotic on reactor performance and to also examine the development of antibiotic-resistant communities within the system.

Bioreactor Systems↗

Preliminary On-Orbit Neutron Dose Equivalent and Energy Spectrum Results from the ISS-RAD Fast Neutron Detector (FND)

The ISS-RAD instrument was activated on ISS on February 1st, 2016. Integrated in ISS-RAD, the Fast Neutron Detector (FND) performs, for the first time on ISS, routine and precise direct neutron measurements between 0.5 and 8 MeV. Preliminary results for neutron dose equivalent and neutron flux energy distributions from online/on-board algorithms and offline ground analyses will be shown, along with comparisons to simulated data and previously measured neutron spectral data. On-orbit data quality and pre-launch analysis validation results will be discussed as well.

Semones, Edward↗

Cosmic Radiation Dose Measurements from the RaD-X Flight Campaign

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5 degrees North, 104.2 degrees West) on 25 September 2015. Over 18 hours of flight data were obtained from each of the four different science instruments at altitudes above 20 kilometers. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

Mertens, Christopher J.↗

Increased Dependence on Saccades for Ocular Tracking with Low Dose Alcohol

Previous studies have shown that certain features of oculomotor performance are impaired at or slightly below the legal limit for driving in most U.S. States (0.08% Blood Alcohol Concentration or BAC). Specifically, alcohol impairs saccadic velocity and steady-state tracking at levels between 0.04% and 0.1% BAC. Here we used a suite of standardized oculometric measures to examine the effect of ultra-low levels of alcohol (down to 0.01% BAC) on steady-state tracking. Our high-uncertainty tracking task reveals that the smooth pursuit system is highly sensitive to BAC, with impairmentextrapolating back to BAC levels at or below 0.01%. BAC generates a dose dependent increase in reliance on the saccadic system that maintains overall steady-state tracking effectiveness at least up to 0.08% BAC, albeit with a significant decrease in smoothness.

Tyson, Terence L.↗

Total Ionizing Dose Response of SDRAM, DDR2 and DDR3 Memories

Total Ionizing Dose response (ID) of SDRAM (Synchronous Dynamic Random Access Memory), DDR2 (Double Data Rate2) and DDR3 (Double Data Rate3) memories is reported in static bias, and auto refresh modes. Data analysis reveals some types of memory have significant increases in stuck bits during TID exposure when refreshed.

Amrbar, Mehran↗

Compendium of Single Event Transient (SET) and Total Ionizing Dose (TID) Test Results for Commonly Used Voltage Comparators

This data compendium reports single event transient (SET) and total ionizing dose (TID) test results for commonly used commercial-off-the-shelf (COTS) and radiation hardened voltage comparators targeted for possible use in space-based missions. Interesting trends in the variability of the radiation performance of these devices due to differences in lot date codes, manufacturers, circuit design, and test conditions are analyzed herein.

Bozovich, Amanda↗

Mice Exposed to Combined Chronic Low-Dose Irradiation and Modeled Microgravity Develop Long-Term Neurological Sequelae

Spaceflight poses many challenges for humans. Ground-based analogs typically focus on single parameters of spaceflight and their associated acute effects. This study assesses the long-term transcriptional effects following single and combination spaceflight analog conditions using the mouse model, simulated microgravity via hindlimb unloading (HLU) and/or low-dose irradiation (LDR) for 21-days, followed by 4 months of readaptation. Changes in gene expression and epigenetic modifications in whole brain samples during readaptation were analyzed by DESeq2 and reduced representation bisulfite sequencing (RRBS). The results showed minimal gene expression alterations at 4-months within single treatment conditions of HLU and LDR. Following combined HLU+LDR, gene ontology and methylation analyses showed multiple altered pathways involved in neurogenesis and neuroplasticity, regulation of neuropeptides and cellular signaling. In brief, neurological readaptation following combined chronic LDR and HLU is a dynamic process that impacts brain structure and function and may lead to late onset neurological sequelae

Overbey, Eliah G.↗

Behavioral consequences of low dose radiation and sex differences in MCAT mouse model

Our study used 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation and were euthanized 12 weeks after. In this study, we used an MCAT mouse model for mitochondrial ROS quenching, which overexpress human catalase. MCAT mice were shown to live longer and age better. Hence, in this study we determined whether quenching ROS in the mitochondria will mitigate the adverse effects of ionizing radiation exposure on spaceflight-relevant tissues. As part of the analysis, we have completed 5 different behavioral tests which focus on memory, physical stance, stress, anxiety, and other mission relevant behaviors. In the Neuro-score battery, performed after both 1and 8 weeks post IR we saw that all female groups had significantly higher scores compared to males. When comparing the baseline vs 8 weeks of radiation, we saw that all the male groups (including the sham) had lower neuro-score, pointing out to aging effect in addition to IR. In the female groups only the female IR group had lower neuro-score and the MCAT group was protected from this effect. In the Nestlet building test we saw similarly that only females were affected by radiation, having lower scores and this effect was mitigated in the MCAT animals as well. In the Catwalk test we saw that females were faster, had higher swing speed and stride length in all four paws. Males had higher stand, step cycle and max contact area. Aging is associated with slowing of gait speed, swing speed and shortening of stride length which we see in males, this is consistent with physical appearance where males look markedly older. In the Light-Dark Box test we saw that females were more frequently present in the light side and altered zones more frequently, pointing out to a more exploratory and less anxious pattern of behavior. Similarly, to what was detected in the Nest building and Neuro-score test, in the Barnes maze test, during the acquisition phase (learning) we saw that IR affected more the females who did not do better in the maze after 4 days. On the other hand, during the probe phase of the test (spatial memory) the females visited the target hole and the box quadrant more often, but also had more errors vs males, which points out to possible serial escape vs spatial escape strategy. Overall, we see that older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was mitigated in the MCAT model pointing out to the importance of ROS in these stressors. In the near future we will focus on corelating these behavioral tests with molecular findings such as for example brain IHC, plasma and hippocampal cytokines in order to find specific biomarkers for behavioral deficits.

radiation↗

Total Dose Testing of a CMOS Charged Particle Spectrometer

A first-generation CMOS Charged Particle Spectrometer chip [1] was designed at JPL for flight on the STRV-2 spacecraft. These devices will collect electron and proton spectra in low Earth orbit as part of an experiment to demonstrate Active Pixel Sensor (APS) technology in space. This paper presents the results of total dose testing on these chips and, where possible, attempts to extend the results to other Active Pixel Sensors.

CMOS↗

SRAM-based FPGA: high dose test methods using evaluation boards

We present low-cost and effective methods and results for high levels of Total Ionizing Dose testing performed on the Xilinx Kintex UltraScale (20nm) Field-Programmable Gate Array evaluation board using 60Co and 2 MeV electron sources.

Thorbourn, Dennis↗