Search NASA⌕ Search

SEARCH · Search NASA

Results for “image sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Note: A disposable x-ray camera based on mass produced complementary metal-oxide-semiconductor sensors and single-board computers

We have integrated mass-produced commercial complementary metal-oxide-semiconductor (CMOS) image sensors and off-the-shelf single-board computers into an x-ray camera platform optimized for acquisition of x-ray spectra and radiographs at energies of 2–6 keV. The CMOS sensor and single-board computer are complemented by custom mounting and interface hardware that can be easily acquired from rapid prototyping services. For single-pixel detection events, i.e., events where the deposited energy from one photon is substantially localized in a single pixel, we establish ∼20% quantum efficiency at 2.6 keV with ∼190 eV resolution and a 100 kHz maximum detection rate. The detector platform’s useful intrinsic energy resolution, 5-μm pixel size, ease of use, and obvious potential for parallelization make it a promising candidate for many applications at synchrotron facilities, in laser-heating plasma physics studies, and in laboratory-based x-ray spectrometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IKONOS Spatial Resolution and Image Interpretability Characterization

This paper contains research from five individual projects to characterize the spatial performance of the IKONOS commercial imaging sensor. The end result of the projects is determination of the spatial image quality of IKONOS data prodicts in terms of the National Imagery Interpretability Rating Scale (NIIRS), the system Modulation Transfer Function (MTF), the system stability over the first year, the characteristics of the Space Imaging MTF Compensation (MTFC) procedure, and the application-specific capabilities of IKONOS imagery. Both panchromatic and multispectral imagery were evaluated. Major conclusions of this work are that the system was stable im imaging performance during the first year of operation, tha its MTF meets the specification for the NASA Scientific Data Purchase program, that the initial MTFC processing appears to be transposed in the in-track and the cross-track directions, that the MTFC results in a noise amplification of 2x to 4x in addition to sharpening the imagery, and that IKONOS panchromatic imagery achieves an average NIIRS rating of 4.5.

Ryan, Robert↗

Microwave and camera sensor fusion for the shape extraction of metallic 3D space objects

The vacuum of space presents special problems for optical image sensors. Metallic objects in this environment can produce intense specular reflections and deep shadows. By combining the polarized RCS with an incomplete camera image, it has become possible to better determine the shape of some simple three-dimensional objects. The radar data are used in an iterative procedure that generates successive approximations to the target shape by minimizing the error between computed scattering cross-sections and the observed radar returns. Favorable results have been obtained for simulations and experiments reconstructing plates, ellipsoids, and arbitrary surfaces.

Shaw, Scott W.↗

Radiometric Calibration of the AWiFS Using Vicarious Calibration Techniques

A radiometric calibration assessment of the AWiFS (Advanced Wide Field Sensor) on the Indian Remote Sensing Resourcesat-1 satellite was performed by the NASA Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) at the John C. Stennis Space Center. A reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with satellite acquisitions and radiative transfer calculations, was used to estimate at-sensor radiance. The AWiFS is a 4-band, multispectral, moderate-resolution (60 m) imaging sensor that operates in the visible through short-wave infrared spectrum and is currently being considered as a Landsat-like alternative. Several study sites near the Stennis Space Center that attempted to span the dynamic range of the sensor were employed. Satellite at-sensor radiance values were compared to those estimated to determine the sensor's radiometric accuracy. The results of this evaluation provide the user community with an independent assessment of the radiometric accuracy of AWiFS image products, which are commercially available through GeoEye. These results are an extension of an independent assessment made by the University of Arizona Remote Sensing Group, the South Dakota State University Satellite Calibration Group & Image Processing Lab, and the NASA Applied Sciences Directorate at the John C. Stennis Space Center the previous year.

Pagnutti, Mary↗

Design and Performance of an Image Processing Occupancy Sensor

The design and performance of a novel image-processing occupancy sensor (IPOS) based on production-grade embedded hardware are described. The IPOS overcomes several issues related to traditional passive infrared (PIR) and ultrasonic-based motion sensors. It also provides a rich set of feedback signals that more sophisticated applications can use for occupant-optimized lighting, daylighting,temperature,and ventilation control, as well as with building security systems. The IPOS was tested as part of an integrated system consisting of a building energy management system (EMS) alongside a pair of PIR sensors produced by different manufacturers. IPOS output was fed to the EMS via the building automation and controls network (BACnet) and logged alongside the PIR outputs in an officeenvironment over several days. Tests suggest the IPOS device identifies occupancy events better than two commercial PIR sensors (94.1% accuracy compared to 73.1% on average). Also, IPOS could correctly identify stationary occupants whereas the PIR sensors could not.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Necessity to adapt land use and land cover classification systems to readily accept radar data

A hierarchial, four level, standardized system for classifying land use/land cover primarily from remote-sensor data (USGS system) is described. The USGS system was developed for nonmicrowave imaging sensors such as camera systems and line scanners. The USGS system is not compatible with the land use/land cover classifications at different levels that can be made from radar imagery, and particularly from synthetic-aperture radar (SAR) imagery. The use of radar imagery for classifying land use/land cover at different levels is discussed, and a possible revision of the USGS system to more readily accept land use/land cover classifications from radar imagery is proposed.

Drake, B.↗

Capaciflector Camera

Sensing electrodes arranged in rows and columns used to generate capacitive images. Sensors of this type installed on robot arms, and three-dimensional capacitance images that they generate used by robot-control circuits to prevent collisions with capacitively sensed objects, to image and identify these objects, and to navigate amongst them.

Vranish, John M.↗

Hyperspectral Image Classification using a Self-Organizing Map

The use of hyperspectral data to determine the abundance of constituents in a certain portion of the Earth's surface relies on the capability of imaging spectrometers to provide a large amount of information at each pixel of a certain scene. Today, hyperspectral imaging sensors are capable of generating unprecedented volumes of radiometric data. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), for example, routinely produces image cubes with 224 spectral bands. This undoubtedly opens a wide range of new possibilities, but the analysis of such a massive amount of information is not an easy task. In fact, most of the existing algorithms devoted to analyzing multispectral images are not applicable in the hyperspectral domain, because of the size and high dimensionality of the images. The application of neural networks to perform unsupervised classification of hyperspectral data has been tested by several authors and also by us in some previous work. We have also focused on analyzing the intrinsic capability of neural networks to parallelize the whole hyperspectral unmixing process. The results shown in this work indicate that neural network models are able to find clusters of closely related hyperspectral signatures, and thus can be used as a powerful tool to achieve the desired classification. The present work discusses the possibility of using a Self Organizing neural network to perform unsupervised classification of hyperspectral images. In sections 3 and 4, the topology of the proposed neural network and the training algorithm are respectively described. Section 5 provides the results we have obtained after applying the proposed methodology to real hyperspectral data, described in section 2. Different parameters in the learning stage have been modified in order to obtain a detailed description of their influence on the final results. Finally, in section 6 we provide the conclusions at which we have arrived.

Martinez, P.↗

A New Generation of Intelligent Trainable Tools for Analyzing Large Scientific Image Databases

In a variety of scientific disciplines two-dimensional digital image data is now relied on as a basic component of routine scientific investigation. The proliferation of image acquisition hardware such as multi-spectral remote-sensing platforms, medical imaging sensors, and high-resolution cameras have led to the widespread use of image data in fields such as atmospheric studies, planetary geology, ecology, agriculture, glacielogy, forestry, astronomy, diagnostic medicine, to name but a few.

machine↗

Methods for estimating photosynthetic characteristics in plant canopies and systems and apparatus related thereto

Methods of determining and characterizing photosynthesis in plant parts of one or more plants includes capturing a plurality of images of the plant parts of the one or more plants with a sensor are provided. Fluorescence of the plant parts of the one or more plants can be measured by storing a sensor image of observed fluorescence. Light absorbed by the plant parts of the one or more plants can be estimated by observing red and/or infrared reflectance of the plant parts. A characteristic of photosynthesis such as linear electron flow in plant parts of the one or more plants can be derived using the measured fluorescence of the plant parts, the reflectance and the light absorbed by the plant parts, and/or the three-dimensional model comprising the plant parts of the one or more plants. Related apparatus and systems are also provided.

54 ENVIRONMENTAL SCIENCES↗

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

Ground-reference site and on-board methods for sensor absolute calibration in the 0.4 to 2.5 micron range

The absolute radiometric calibration uncertainty requirement for several multispectral imaging sensors to be used in the Earth Observing System (EOS) program is +/- 2 percent (one sigma) with respect to the sun. Proposed in-flight absolute calibration methods are reviewed that have this uncertainty as their goal. In particular two methods are described as are recent improvements to them that concern reflectance- and radiance-based calibration using a carefully selected ground reference site. The magnitudes of the error sources are listed. A ratioing radiometer approach to monitoring the reflectance of a solar diffuser used for onboard calibration is discussed.

Slater, P. N.↗

Single sensor processing to obtain high resolution color component signals

A method for generating color video signals representative of color images of a scene includes the following steps: focusing light from the scene on an electronic image sensor via a filter having a tri-color filter pattern; producing, from outputs of the sensor, first and second relatively low resolution luminance signals; producing, from outputs of the sensor, a relatively high resolution luminance signal; producing, from a ratio of the relatively high resolution luminance signal to the first relatively low resolution luminance signal, a high band luminance component signal; producing, from outputs of the sensor, relatively low resolution color component signals; and combining each of the relatively low resolution color component signals with the high band luminance component signal to obtain relatively high resolution color component signals.

Glenn, William E.↗

Ultrafast image-based dynamic light scattering for nanoparticle sizing

An ultrafast sizing method for nanoparticles is proposed, called as UIDLS (Ultrafast Image-based Dynamic Light Scattering). This method makes use of the intensity fluctuation of scattered light from nanoparticles in Brownian motion, which is similar to the conventional DLS method. The difference in the experimental system is that the scattered light by nanoparticles is received by an image sensor instead of a photomultiplier tube. A novel data processing algorithm is proposed to directly get correlation coefficient between two images at a certain time interval (from microseconds to milliseconds) by employing a two-dimensional image correlation algorithm. This coefficient has been proved to be a monotonic function of the particle diameter. Samples of standard latex particles (79/100/352/482/948 nm) were measured for validation of the proposed method. The measurement accuracy of higher than 90% was found with standard deviations less than 3%. A sample of nanosilver particle with nominal size of 20 ± 2 nm and a sample of polymethyl methacrylate emulsion with unknown size were also tested using UIDLS method. The measured results were 23.2 ± 3.0 nm and 246.1 ± 6.3 nm, respectively, which is substantially consistent with the transmission electron microscope results. Since the time for acquisition of two successive images has been reduced to less than 1 ms and the data processing time in about 10 ms, the total measuring time can be dramatically reduced from hundreds seconds to tens of milliseconds, which provides the potential for real-time and in situ nanoparticle sizing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clementine Sensor Processing System

The design of the DSPSE Satellite Controller (DSC) is baselined as a single-string satellite controller. The DSC performs two main functions: health and maintenance of the spacecraft; and image capture, storage, and playback. The DSC contains two processors: a radiation-hardened Mil-Std-1750, and a commercial R3000. The Mil-Std-1750 processor performs all housekeeping operations, while the R3000 is mainly used to perform the image processing functions associated with the navigation functions, as well as performing various experiments. The DSC also contains a data handling unit (DHU) used to interface to various spacecraft imaging sensors and to capture, compress, and store selected images onto the solid-state data recorder. The development of the DSC evolved from several key requirements; the DSPSE satellite was to do the following: (1) have a radiation-hardened spacecraft control system and be immune to single-event upsets (SEU's); (2) use an R3000-based processor to run the star tracker software that was developed by SDIO (due to schedule and cost constraints, there was no time to port the software to a radiation-hardened processor); and (3) fly a commercial processor to verify its suitability for use in a space environment. In order to enhance the DSC reliability, the system was designed with multiple processing paths. These multiple processing paths provide for greater tolerance to various component failures. The DSC was designed so that all housekeeping processing functions are performed by either the Mil-Std-1750 processor or the R3000 processor. The image capture and storage is performed either by the DHU or the R3000 processor.

Feldstein, A. A.↗

TRMM and its Connection to the Global Water Cycle

The importance of quantitative knowledge of tropical rainfall, its associated latent heating and variability is summarized in the context of the global hydrologic cycle. Much of the tropics is covered by oceans. What land exists, is covered largely by rainforests that are only thinly populated. The only way to adequately measure the global tropical rainfall for climate and general circulation models is from space. The Tropical Rainfall Measuring Mission (TRMM) orbit is inclined 35 degrees leading to good sampling in the tropics and a rapid precession to study the diurnal cycle of precipitation. The precipitation instrument complement consists of the first rain radar to be flown in space (PR), a multi-channel passive microwave sensor (TMI) and a five-channel VIS/IR (VIRS) sensor. The precipitation radar operates at a frequency of 13.6 GHz. The swath width is 220 km, with a horizontal resolution of 4 km and the vertical resolution of 250 m. The minimum detectable signal from the precipitation radar has been measured at - 17 dBZ. The TMI instrument is designed similar to the SSM/I with two important changes. The 22.235 GHz water vapor absorption channel of the SSM/I was moved to 21.3 GHz in order to avoid saturation in the tropics and 10.7 GHz V&H polarized channels were added to expand the dynamic range of rainfall estimates. The resolution of the TMI varies from 4.6 km at 85 GHz to 36 km at 10.7 GHz. The visible and infrared sensor (VIRS) measures radiation at 0.63, 1.6, 3.75, 10.8 and 12.0 microns. The spatial resolution of all five VIRS channels is 2 km at nadir. In addition to the three primary rainfall instruments, TRMM will also carry a Lightning Imaging Sensor (LIS) and a Clouds and the Earth's Radiant Energy System (CERES) instrument. This presentation will focus primarily on the advances in our understanding of tropical rain systems needed to interpret the TRMM data. Global averages, as well as case studies from TRMM radar (PR), the TRMM Microwave Imager (TMI) and Visible and Infrared Sensor (VIRS) will be presented. Comparisons and contrasts among the different sensors will be drawn. Results will also be compared to previous rainfall climatologies generated from the SSM/I instrument. In particular this paper will focus on the synergy between the TRMM radar and passive microwave radiometer and what we have learned from its synergy.

Kummerow, Christian↗