Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Decoding the Atomic Structure of Ga 2 Te 5 Pulsed Laser Deposition Films for Memory Applications Using Diffraction and First-Principles Simulations

Neuromorphic computing, reconfigurable optical metamaterials that are operational over a wide spectral range, holographic and nonvolatile displays of extremely high resolution, integrated smart photonics, and many other applications need next-generation phase-change materials (PCMs) with better energy efficiency and wider temperature and spectral ranges to increase reliability compared to current flagship PCMs, such as Ge 2 Sb 2 Te 5 or doped Sb 2 Te. Gallium tellurides are favorable compounds to achieve the necessary requirements because of their higher melting and crystallization temperatures, combined with low switching power and fast switching rate. Ga 2 Te 3 and non-stoichiometric alloys appear to be atypical PCMs; they are characterized by regular tetrahedral structures and the absence of metavalent bonding. The sp 3 gallium hybridization in cubic and amorphous Ga 2 Te 3 is also different from conventional p-bonding in flagship PCMs, raising questions about its phase-change mechanism. Furthermore, gallium tellurides exhibit a number of unexpected and highly unusual phenomena, such as nanotectonic compression and viscosity anomalies just above their melting points. Using high-energy X-ray diffraction, supported by first-principles simulations, we will elucidate the atomic structure of amorphous Ga 2 Te 5 PLD films, compare it with the crystal structure of tetragonal gallium pentatelluride, and investigate the electrical, optical, and thermal properties of these two materials to assess their potential for memory applications, among others.

36 MATERIALS SCIENCE↗

Silicon Materials and Devices

To contribute to the U.S. Department of Energy's involvement with the U.S. photovoltaic (PV) industry's efforts to meet very competitive PV efficiency, cost, and reliability goals, NREL's Silicon PV program focuses on next-generation, high-efficiency silicon (Si) PV.

14 SOLAR ENERGY↗

Predicting temperature-dependent ultimate strengths of body-centered-cubic (BCC) high-entropy alloys

This paper presents a bilinear log model, for predicting temperature-dependent ultimate strength of high-entropy alloys (HEAs) based on 21 HEA compositions. We consider the break temperature, T break , introduced in the model, an important parameter for design of materials with attractive high-temperature properties, one warranting inclusion in alloy specifications. For reliable operation, the operating temperature of alloys may need to stay below T break . We introduce a technique of global optimization, one enabling concurrent optimization of model parameters over low-temperature and high-temperature regimes. Furthermore, we suggest a general framework for joint optimization of alloy properties, capable of accounting for physics-based dependencies, and show how a special case can be formulated to address the identification of HEAs offering attractive ultimate strength. We advocate for the selection of an optimization technique suitable for the problem at hand and the data available, and for properly accounting for the underlying sources of variations.

36 MATERIALS SCIENCE↗

Evaluation of microstructural changes in fresh cement paste using AC impedance spectroscopy vs. oscillation rheology and 1H NMR relaxometry

AC impedance spectroscopy (ACIS) is a promising technique for monitoring the microstructure evolution of fresh cement paste in real-time. This paper compared the change of bulk electric resistivity (ρ{sub bulk}) obtained from ACIS with the developments of storage modulus (G′) and the mean transverse relaxation times (T{sub 2}) of fresh Portland cement pastes within 5 h. It was found that the three different phases (Phase I, II, and III) on the microstructural build-up process of fresh paste can be accurately distinguished by analyzing ρ{sub bulk}, as well as G′ and T{sub 2}. The use of ρ{sub bulk} fails to characterize the microstructural changes in Phase I due to the great sensitivity on the electrical conductivity of the interstitial solution. However, it can successfully reflect the developing features of microstructure in Phases II and III, and reliably evaluate the impacts of water to cement ratio, superplasticizer, and supplementary cementitious materials on the microstructural development.

36 MATERIALS SCIENCE↗

High-energy and low-cost membrane-free chlorine flow battery

Abstract Grid-scale energy storage is essential for reliable electricity transmission and renewable energy integration. Redox flow batteries (RFB) provide affordable and scalable solutions for stationary energy storage. However, most of the current RFB chemistries are based on expensive transition metal ions or synthetic organics. Here, we report a reversible chlorine redox flow battery starting from the electrolysis of aqueous NaCl electrolyte and the as-produced Cl 2 is extracted and stored in the carbon tetrachloride (CCl 4 ) or mineral spirit flow. The immiscibility between the CCl 4 or mineral spirit and NaCl electrolyte enables a membrane-free design with an energy efficiency of >91% at 10 mA/cm 2 and an energy density of 125.7 Wh/L. The chlorine flow battery can meet the stringent price and reliability target for stationary energy storage with the inherently low-cost active materials (~$5/kWh) and the highly reversible Cl 2 /Cl − redox reaction.

25 ENERGY STORAGE↗

The search for high-entropy fuel-cell catalysts using disorder descriptors

The transition to a hydrogen economy depends on efficient, affordable catalysts for fuel cells. Platinum—the industry standard for fuel-cell electrodes—is costly and scarce, highlighting the need for practical alternatives. High-entropy alloys offer vast compositional diversity and tunable properties that can mitigate these issues, yet their chemical complexity and configurational disorder have hindered rational discovery. Here, we introduce a data-driven framework that couples machine learning with first-principles disorder descriptors—including the entropy forming ability, disordered enthalpy-entropy descriptor, and electronic-structure similarity metrics to platinum—to predict alloy synthesizability and catalytic performance. These descriptors are applied for the first time in the context of fuel-cell catalyst discovery. The workflow rapidly screens more than 20 000 compositions and identifies several platinum-free candidates that are economically viable, readily scalable, and exhibit promising predicted activity. These results demonstrate that disorder descriptors are reliably predicted by machine learning models and can be effectively integrated into materials-discovery pipelines, accelerating innovation across complex compositional spaces.

fuel-cell catalysts↗

LatticeAnalytics: Strut-Level Visualization and Inspection of Additively Manufactured Lattice Structures

Additive manufacturing (AM) is revolutionizing the production of custom components with complex internal geometries, essential for high-performance applications in diverse fields such as medicine and defense. These AM parts optimize strength while minimizing weight by utilizing internal lattice structures consisting of large quantities of small interconnected struts. However, the complexity of these structures, combined with the challenges of using X-ray Computed Tomography (XCT) data, makes validation of part reliability difficult. This ultimately inhibits the development of novel parts for our collaborating material scientists. Here, we introduce LatticeAnalytics, a novel framework specifically designed for visual inspection of defects in these lattice structures. Our framework offers an end-to-end solution that includes the data management of XCT scans, enables remote access for geographically dispersed teams through a web-based dashboard, and incorporates novel visualizations. Our analysis is facilitated by a coarse alignment between the lattice’s nominal model, a spatial graph, and the XCT data. We employ a simple VR-based approach for fast and rough alignment, followed by an offline registration and identification of the struts. With the nodes and struts aligned and identified in the volume, our framework allows querying of subvolumes containing a single strut at multiple resolutions. This avoids computation over the entire lattice and also allow for easy parallelization of down-stream computations, such as strut-specific metrics. To depict a fast overview of the strut quality, we introduce two innovative visual encodings, crucial for our collaborators’ research in creating novel AM parts: the Contour View and the Roughness Map, which depict critical geometrical and surface features of individual struts in standardized two 2D views. We evaluated the integrated system through expert interviews. The feedback confirms the framework’s practicality and its effectiveness in enhancing current inspection workflows. It solves major bottlenecks for our collaborators, ultimately helping them create novel parts with advanced properties.

Miao, Haichao [Lawrence Livermore National Laborat↗

MODELING AND OPTIMIZATION OF A PCM-BASED OCEAN THERMAL ENERGY HARVESTER FOR POWERING UNMANNED UNDERWATER VEHICLES

As oceans cover over 70% of the planet’s surface, they represent a large reservoir of resources that remained vastly untapped. Uncrewed Underwater Vehicles (UUVs) are becoming key technology for ocean exploration. Ocean thermal gradient is a permanent and reliable energy source that can be used to power UUVs using phase change material (PCM)-based thermal engines. However, the main drawback of this technology is its low conversion efficiency. When using PCM-based thermal engines to power UUVs, there are different energy conversion stages, thermal-hydraulic, hydraulic-kinetic, kinetic-electrical, dependent of a wide variety of parameters. Thus, optimization of the overall energy conversion is still a challenge for powering the increasing energy demanding UUVs for long missions. The goal of this study is to propose a PCM-based ocean thermal energy harvesting system for powering the Solo II float. Using the ocean thermal energy reduces the cost for battery replacement and expands the float’s mission time. For this purpose, we developed a multiphysics model for a system consisting of thermal material, hydraulic, and electrical systems. This system is designed to provide the electrical power needed for the instruments aboard the underwater vehicle. The models of the hydraulic and the electric systems are implemented in MATLAB-Simulink/Simscape environment. The final model developed can provide 13.66 kJ of electrical energy, which is more than 1.5 times the energy requirement per cycle for the SOLO II float.

Ouro-Koura, Habilou↗

Anion-exchange membrane water electrolysis: insights from round-robin testing

As research and industrial interest in anion-exchange membrane water electrolysis (AEMWE) grows, there is an increasing need for reliable baselines and cross-lab validation of results. The wide variety of material sets and operating conditions under consideration for AEMWE has thus far limited efforts for standardization. In this study, round-robin testing was conducted in deionized water and KOH-based supporting electrolyte by 5 institutions from academia, national laboratories, and industry to provide baseline performance data and identify sources of cross-lab variability. Baseline membrane electrode assemblies were fabricated with commercial catalysts, membranes, and transport layers using standard techniques and tested using reagent-grade electrolytes, aiming for accessibility rather than state-of-the-art performance. From all tests, the average voltage at 1 A/cm 2 was 2.72 ± 0.17 V and 1.87 ± 0.03 V in deionized water and 0.1 M KOH, respectively. The maximum in-house and cross-lab variations at this current density were 118 mV and 476 mV in water and 60 and 88 mV in 0.1 M KOH. The KOH purity, station contamination, and temperature control were identified as possible factors affecting performance between labs, with in-house specific variation attributed to sample-to-sample differences in fabrication, cell assembly, and station contamination. This work provides a commercial baseline for the field and highlights the need for improved standardization and reproducibility in AEMWE research.

08 HYDROGEN↗

Helium recovery system at IB3A

The growing demand for sustainable cryogenic operations at Fermilab has underscored the need to improve helium management, particularly at the Industrial Building 3A (IB3A) test facility. IB3A characterizes and tests superconductors, cables, and coils for projects such as the HL-LHC AUP and Mu2e, yet currently relies on 500 L Dewars whose boil-off is vented to atmosphere, wasting a critical, non-renewable resource and increasing the cost of testing. A project is therefore under way to link IB3A to an existing purification and liquefaction station in a neighboring building through a dedicated pipeline. Captured helium will be transferred, purified, reliquefied, and returned for reuse, cutting losses and operating costs. This paper details the first two project phases: "Design and Engineering" and "Procurement and Installation." The design phase finalizes pipeline specifications, establishes flow-control requirements, and resolves integration challenges with existing cryogenic infrastructure. The procurement and installation phase covers material sourcing, pipeline construction, and deployment of control and monitoring systems to assure reliable, efficient operation. Key technical hurdles-route optimization, pressure drop mitigation, and interface compatibility-are discussed alongside implemented solutions. Implementing the pipeline and upgrading IB3A will dramatically reduce helium consumption and therefore testing cost, strengthening Fermilab's capacity to support frontier science far into the future.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗

Electro-Optic Modulation Using Metal-Free Perovskites

Electro-optic (EO) modulation is of interest to impart information onto an optical carrier. Inorganic crystals—most notably LiNbO 3 and BaTiO 3 —exhibit EO modulation and good stability, but are difficult to integrate with silicon photonic technology. Solution-processed organic EO materials are readily integrated but suffer from thermal degradation at the temperatures required in operating conditions for accelerated reliability studies. Hybrid organic–inorganic metal halide perovskites have the potential to overcome these limitations; however, these have so far relied on heavy metals such as lead and cadmium. Here, we report linear EO modulation using metal-free perovskites, which maintain the crystalline features of the inorganic EO materials and incorporate the flexible functionality of organic EO chromophores. We find that, by introducing a deficiency of cations, we reduce the symmetry in the perovskite crystal and produce thereby an increased EO response. The best-engineered perovskites reported herein showcase an EO coefficient of 14 pm V –1 at a modulation frequency of 80 kHz, an order of magnitude higher than in the nondefective materials. Furthermore, we observe split peaks in the X-ray diffraction and neutron diffraction patterns of the defective sample, indicating that the crystalline structure has been distorted and the symmetry reduced. Density functional theory (DFT) studies link this decreased symmetry to NH 4 + deficiencies. This demonstration of EO from metal-free perovskites highlights their potential in next-generation optical information transmission.

36 MATERIALS SCIENCE↗

Optimizing the accuracy of viscoelastic characterization with AFM force–distance experiments in the time and frequency domains

Atomic Force Microscopy (AFM) force-distance (FD) experiments have emerged as an attractive alternative to traditional micro-rheology measurement techniques owing to their versatility of use in materials of a wide range of mechanical properties. Here, we show that the range of time dependent behaviour which can reliably be resolved from the typical method of FD inversion (fitting constitutive FD relations to FD data) is inherently restricted by the experimental parameters: sampling frequency, experiment length, and strain rate. Specifically, we demonstrate that violating these restrictions can result in errors in the values of the parameters of the complex modulus. In the case of complex materials, such as cells, whose behaviour is not specifically understood a priori, the physical sensibility of these parameters cannot be assessed and may lead to falsely attributing a physical phenomenon to an artifact of the violation of these restrictions. We use arguments from information theory to understand the nature of these inconsistencies as well as devise limits on the range of mechanical parameters which can be reliably obtained from FD experiments. The results further demonstrate that the nature of these restrictions depends on the domain (time or frequency) used in the inversion process, with the time domain being far more restrictive than the frequency domain. Lastly, we demonstrate how to use these restrictions to better design FD experiments to target specific timescales of a material's behaviour through our analysis of a polydimethylsiloxane (PDMS) polymer sample.

information theory↗

Topological analysis of X-ray CT data for the recognition and trending of subtle changes in microstructure under material aging

X-ray computed tomography (CT) is an established non-destructive tool for 3D imaging of multiphasic composites. Numerous applications of X-ray CT in medical diagnosis and materials characterization have been reported, many involving field-specific innovations in the imaging technology itself. Yet, quantitative summarization to link image features to properties of interest has been rare. Here we address this issue by employing state-of-the-art technics in scalar field topology for the summarization of X-ray CT images of an example biphasic system. By varying processing-parameters we create different microstructures, evolve them through accelerated thermal aging, CT-image them pre- and post-aged, and demonstrate the ability of our image summarization method to systematically track process- and age-related changes, which can often be very subtle. A novel aspect of the algorithm involves recognition over multiple resolution levels, which provides deeper insight into the pattern relationship between grain-like features and their neighbors. The method is general, adaptable to diverse image reconstruction methods and materials systems, and particularly useful in applications where practical constraints on the sample-size limits the reliable use of more complex models, e.g., convolutional neural networks.

36 MATERIALS SCIENCE↗

CO 2 –Based Dual–Tone Resists for Electron Beam Lithography

The increasing global environmental and energy crisis has urgently motivated the advancement of sustainable materials. Significant effort has been focused on developing new materials to replace the fossil-based resists in the semiconductor industry based on greener sources such as ice, dry ice, small organic molecules, and proteins. Such resist materials, however, have yet to meet the stringent requirements of high sensitivity, high resolution, reliable repeatability, and good compatibility with the current protocols. To this end, CO 2 -based polycarbonates (CO 2 -PCs) obtained from the copolymerization of CO 2 and epoxides are demonstrated as sustainable dual-tone (positive & negative tone) resists for electron beam lithography. By adjusting the chemical structure, developing agent, and molecular weight, the CO 2 -PCs present high sensitivities to electron beam (1.3/120 μC cm -2 ), narrow critical dimensions (29/58 nm), and moderate line edge roughness (4.6/26.7 nm) for negative and positive resists, respectively. Here, a deep understanding of the exposure mechanism of CO 2 -PC resists is provided on the basis of the Fourier transform infrared, Raman, and electron ionization mass spectroscopy. 2D photonic crystal devices are fabricated using the negative and positive CO 2 -PC resists, respectively, and both devices show distinct colors derived from their well-defined nanostructures, indicating the great practical potential of CO 2 -derived electron beam resists.

nanofabrication↗