Search NASASearch

SEARCH · Search NASA

Results for “non-thermal plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

559 records · Page 27

Achieving 20.1% Efficiency in Organic Solar Cells Through Interconnected Fibrillar Networks via Local Molecular Stacking

ABSTRACT The performance of organic solar cells (OSCs) is governed by how molecular packing evolves into interconnected networks that facilitate exciton dissociation and charge transport. Using an all‐small‐molecule blend DR3TSBDT:Y6 as a model system, we study how local molecular stacking evolves into performance‐relevant morphology during solvent vapor annealing (SVA) and subsequent thermal annealing (TA). SVA promotes end‐to‐end stacking of amorphous acceptors to form interconnected fibrils, while TA compacts inter‐fibril spacing without disrupting favorable local order. Such molecular‐to‐morphological refinements broaden light absorption, enhance charge transport, and markedly improve device efficiency. Extending this approach to additional blend systems (D18:Y6, D18:L8‐BO, and DR3TSBDT:L8‐BO) yields similar structural evolution and performance gains, with the D18:L8‐BO system achieving up to 20.10% PCE. Our study establishes control over local stacking in amorphous acceptors into fibrillar networks as a general and effective route to realize high‐performance OSCs.

Wu, Junying

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Audible Noise Modeling of Hydrogen Release Sonic Hazards in Rail Maintenance Facilities

This study implemented validated literature models to predict audible noise due to pressurized gaseous hydrogen releases through a thermally-activated pressure relief device (TPRD) and attached vent stack. A literature survey discovered limited hydrogen-specific noise prediction models validated by experiments. However, empirical noise prediction models for air flowing through pipes and valves were identified. These empirical models were used to predict noise levels and compared against hydrogen noise data reported in two studies: one experimental study of noise from hydrogen leaking through a pipe and another which modeled hydrogen flowing through a solenoid valve during a fuel cell vehicle refueling. The valve flow model was then applied to predict noise for hydrogen releases through a TPRD. Results show that hydrogen releases through a TPRD can produce harmful noise levels varying from 134 to 150 dB. However, further model validation and additional experimental data are needed to improve prediction confidence and accuracy.

08 HYDROGEN

Intermodal microwave-to-optical transduction using silicon-on-sapphire optomechanical ring resonator

Optomechanical and electro-optomechanical systems have emerged as one of the most promising approaches for quantum microwave-to-optical transduction to interconnect distributed quantum modalities for scaling the quantum systems. These systems use suspended structures to increase mode overlap and mitigate loss to achieve high efficiency. However, the suspended design’s poor heat dissipation under strong drive limits the ultimate efficiency. Here, we demonstrate an unsuspended optomechanical ring resonator (OMR) based on the silicon-on-sapphire (SOS) platform for microwave-to-optical frequency conversion. The OMR achieves a triply resonant optical-to-optical conversion with an enhanced coupling rateG b = 3.6 gigahertz per square-root milliwatt at a peak conversion efficiency of 1.2% with 3.6-milliwatt microwave drive power and a microwave-to-optical conversion efficiency of 1.5 × 10 −5 at 10-milliwatt optical drive power. Our results show that the unsuspended SOS platform, which mitigates the thermal effect and is compatible with superconducting qubits, is a promising platform for optomechanical circuitry and quantum transduction.

Science & Technology - Other Topics

Effects of high-dose neutron irradiation at light-water reactor relevant temperature on the mechanical properties of SiC/SiC composites

For this study, the neutron dose-dependent evolutions and the underlying mechanisms of properties of SiC fiber-reinforced SiC matrix (SiC/SiC) composites at a temperature relevant to light-water reactors (∼600 K) were investigated and analyzed. Chemical vapor infiltrated (CVI) SiC/SiC composites reinforced with Hi-Nicalon Type S or Tyranno SA3 fiber were neutron-irradiated to doses up to 30 dpa. The irradiated composites retained their flexural strengths. The thermal diffusivity and dimensional changes were mostly retained from 2.0 to 30.2 dpa. Discrepancies in irradiation responses among CVI SiC/SiC composites from different sources were found. Additional microstructural analysis using Raman spectroscopy and numerical analysis on irradiation effect on residual stress were used to explain how the microstructural variables, especially of carbon interphases, affect the mechanical properties in the 30–40 dpa dose range.

Continuous fiber-reinforced ceramic matrix composi

Chiral kinematic theory and converse vortical effects

Response theories in condensed matter typically describe the response of an electron fluid to external electromagnetic fields, while perturbations on neutral particles are often designed to mimic such fields. Here, we study the response of fermions to a space-time-dependent velocity field, thereby sidestepping the issue of gauge charge. First, we use a semiclassical chiral kinematic theory to obtain the local density of current and extract the orbital magnetization. The theory immediately predicts a "converse vortical effect," defined as an orbital magnetization driven by linear velocity. It receives contributions from magnetic moments on the Fermi surface and the Berry curvature of the occupied bands. Then, transcending semiclassics via a complementary Kubo formalism reveals that the uniform limit of a clean system receives only the Berry curvature contribution while other limits sense the Fermi surface magnetic moments too. We propose CoSi as a candidate material and suggest magnetometry of a sample under a thermal gradient to detect the effect. Overall, our study sheds light on the effects of a space-time-dependent velocity field on electron fluids and paves the way for exploring quantum materials using new probes and perturbations.

Chen, Kai [University of Houston]

Effect of magnetic fields on Urca rates in neutron star mergers

Isospin-equilibrating weak processes, called “Urca” processes, are of fundamental importance in astrophysical environments like (proto-)neutron stars, neutron star mergers, and supernovae. In these environments, matter can reach high temperatures of tens of MeVs and be subject to large magnetic fields. We thus investigate Urca rates at different temperatures and field strengths by performing the full temperature and magnetic-fielddependent rate integrals for different equations of state. We find that the magnetic fields play an important role at temperatures of a few MeV, especially close to or below the direct Urca threshold, which is softened by the magnetic field. At higher temperatures, the effect of the magnetic fields can be overshadowed by the thermal effects. Finally, we observe that the magnetic field influences the neutron decay rates more strongly than the electron-capture rates, leading to a shift in the flavor equilibrium.

electroweak interactions in nuclear physics

Activity-induced migration of viscous droplets on a solid substrate

Active matter exploits motion to induce changes in shape and conformation via external input. Here, in this paper, we establish theoretically that viscous liquid droplets containing magnetic nanoparticles with frozen-in magnetic moments, sitting on a solid substrate and surrounded by an ambient gas phase, can deform and migrate under the influence of a magnetic torque. The effect arises because the collective rotation of the magnetic nanoparticles at the liquid–gas interface tilts the droplet away from a symmetric configuration, breaks the reflection symmetry with respect to the centre axis, and leads to a left–right asymmetry of the contact angles. A sufficiently strong magnetic torque leads the contact angles to overcome hysteresis effects leading the droplet to migrate. We develop a general framework to explain how symmetry-breaking affects droplet migration. Thus previous results of droplet spreading and migration can be recovered as special cases. Such droplets can be employed as agents in active surfaces and can move against gravity, chemical and thermal gradients, providing a mechanism that could be utilized by both industry and medicine.

Aggarwal, A. [Northwestern Univ., Evanston, IL (Un

Low-Temperature Gold Deposition Improves CdTe Back Contacts

Improved back contacts can benefit CdTe photovoltaics (PV). In this work, Cd(Se,Te) PV absorbers are cooled during Au evaporation to thermally quench a chemical reaction occurring between gold and CdTe and the generation of a reaction product that lowers device efficiency. Reducing substrate temperature enhances PV power conversion efficiency via open-circuit voltage and fill factor increases. X-ray photoelectron spectroscopy (XPS) reveals that lower temperature also reduces chemical perturbations of the CdTe, potentially linking back contact formation to a CdTe degradation product that hinders PV performance. Comparing reaction enthalpy and substrate heating energy shows that back contact formation by sputtering elemental metals onto ZnTe may exhibit a degradation pathway analogous to that of CdTe/Au reported here. Degradation-diminishing contact formation processes are therefore of general interest for optoelectronic devices, and the reduced substrate temperature in this study is one example.

14 SOLAR ENERGY

Energy filtering–induced ultrahigh thermoelectric power factors in Ni 3 Ge

Traditional thermoelectric materials rely on low thermal conductivity to enhance their efficiency but suffer from inherently limited power factors. Innovative pathways to optimize electronic transport are thus crucial. Here, we achieve ultrahigh power factors in Ni 3 Ge-based systems through an unconventional thermoelectric materials design principle. When overlapping flat and dispersive bands are engineered to the Fermi level, charge carriers can undergo intense interband scattering, yielding an energy filtering effect similar to what has long been predicted in certain nanostructured materials. Via a multistep DFT-based screening method developed here, we find a family of L1 2 -ordered binary compounds with ultrahigh power factors up to 11 mW m −1 K −2 near room temperature, which are driven by an intrinsic phonon-mediated energy filtering mechanism. Our comprehensive experimental and theoretical study of these intriguing materials paves the way for understanding and designing high-performance scattering-tuned metallic thermoelectrics.

Science & Technology - Other Topics

Trajectory-independent speed limits for controlled open quantum systems

Existing quantum speed limits for controlled open quantum systems depend on the specified trajectory. For example, lower bounds on quantum annealing times in the presence of dissipation depend explicitly on the chosen annealing schedule. Recently, schedule-independent speed limits have been derived for annealing in the closed quantum system setting [L. P. García-Pintos et al ., SciPost Phys. 18 , 159 (2025)]. In this work, we generalize these results to open quantum systems, deriving schedule-independent lower bounds for quantum annealing times in systems described by a Lindblad master equation. We analyze the interplay between coherent control and dissipation in single- and two-qubit examples, demonstrating that the derived lower bounds capture key scaling behavior with respect to the strength of the dissipator. Finally, we apply the bound to thermal state preparation and show that the bound matches the expected asymptotic behavior for an Ising model in the high-temperature limit.

open quantum systems & decoherence

Propane Activation on Pt Electrodes at Room Temperature: Quantification of Adsorbate Identity and Coverage

Abstract C−H bond activation is the first step in manufacturing chemical products from readily available light alkane feedstock and typically proceeds via carbon‐intensive thermal processes. The ongoing emphasis on decarbonization via electrification motivates low‐temperature electrochemical alternatives that could lead to sustainable chemicals production. Platinum (Pt) electrocatalysts have shown activity towards reacting alkanes; however, little is known about propane electrocatalytic activation and conditions suitable for enabling selective oxidation to valuable products. Herein, we utilize a combination of electrochemical mass spectrometry (ECMS) and density functional theory (DFT) calculations to elucidate the potential dependence of propane activation on Pt electrocatalysts. Results show a strong dependence of adsorption on the applied potential in room‐temperature aqueous acidic electrolyte, with a maximum coverage of propane‐derived adsorbates at 0.30 V vs RHE. Using charge deconvolution and deuterated experiments, the mechanism of adsorption was elucidated, and C 3 H 2 * was determined as the average dehydrogenated propane‐derived adsorbate species. DFT calculations further corroborate these results, showing that the formation of deeply dehydrogenated species is energetically accessible at room temperature. The combined theoretical and experimental findings yield insights for selective activation of paraffinic C−H bonds at room temperature, aqueous conditions—a critical step towards decarbonized chemical manufacturing.

Chemistry

A rigorous framework for an improved Messinger/Myers model of ice accretion under conditions of variable property and unsteady aircraft icing

We analyse the Messinger/Myers model by critically evaluating simplifying assumptions through a rigorous formulation of the rime ice accretion process. We explore the effects of both constant and variable ice density and thermal conductivity, along with the effects of sublimation from the ice surface. The effects of key factors such as droplet impact rate, ambient temperature relative to the freezing temperature and the temperature difference between the ambient air and the airfoil surface are examined. Under these varying conditions, the present rigorous formulation is used to assess the significance of unsteady effects, variable ice properties and sublimation. We observe that the Myers model performs remarkably well in certain icing situations and analyse the reasons for this strong performance. We also show that partially relaxing the model’s assumptions can lead to poorer performance. The Myers model can lead to overprediction of ice surface temperature and correspondingly underprediction of transition time under conditions of relatively weak sublimation and surface cooling. A modified Myers model is presented, which can be used to recover near-perfect results under widely varying icing conditions of relevance. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics

Hybrid Power Purchase Agreements for Flexible 24/7 Energy Delivery – A Comprehensive Review of Current Practices and Research Pathways

Power Purchase Agreements (PPAs) are becoming increasingly preferred among large energy consumers, such as data centers, to secure cost-effective energy and meet accelerating demand growth. Traditionally, variable renewable energy (VRE)-based PPAs operate on a pay-as-produced basis, balancing supply and demand for a relatively longer duration (e.g., annually). However, the focus is shifting toward matching supply and demand on an hourly basis to fully meet energy needs. This shift requires the integration of flexible energy resources, such as hydropower, thermal generation, and energy storage, to complement VRE sources like wind and solar, forming the foundation for 24/7 PPA. This work contributes by: (i) reviewing emerging market trends and current practices in PPA procurement, supported by data on PPA prices and technology portfolios; (ii) synthesizing the existing literature on modeling approaches for contract pricing, quantities, hybrid resource procurement, and risk management in 24/7 PPA design, while identifying key research gaps; and (iii) proposing an integrated 24/7 PPA design framework along with two contracting mechanisms from the perspectives of both PPA providers and consumers. The proposed framework highlights critical modeling challenges, risk-allocation issues, and future research opportunities for 24/7 PPA design.

24/7

Microstructural Engineering of Cu-Rich Nanoprecipitate formation in NiCoFeCrCu0.12 High-Entropy Alloy via Severe Plastic Deformation for Enhanced Irradiation Tolerance

This study demonstrates a defect-engineering approach for controlling Cu-rich precipitates in FeNiCrCoCu0.2 high-entropy alloys (Cu-HEAs), delivering a novel pathway for next-generation nuclear reactor materials with superior irradiation resistance. This work establishes that severe plastic deformation (SPD) processing via Shear Assisted Processing and Extrusion (ShAPE) and Friction Stir Layer Deposition (FSLD) creates dense dislocation networks and subgrain boundaries that fundamentally alter precipitation behavior under identical thermal treatments. Atom probe tomography (APT) indicates that SPD produces a metastable, atomically homogeneous solid solution that, upon moderate heat treatment (500°C/10 hour), develops remarkedly stronger Cu clustering than the as-cast counterpart. High-temperature exposure (800°C/100 h) produces near-pure Cu precipitates (~90 at% Cu) with significantly enhanced defect-sink efficacy in SPD-processed alloys: precipitate sizes of 50-60 nm and number densities of 2.7-3.8 × 10¹7 m?³, compared to 89 nm and 0.44 × 10¹7 m?³ in as-cast materials. Collectively, the findings establish defect-mediated precipitation control as a scalable, high-impact route to tailor sink density and distribution in HEAs, enabling microstructures optimized for irradiation tolerance and mechanical robustness in nuclear reactor environments.

Meher, Subhashish

Contrasting structural reversibility and magnetic correlations in isostructural honeycomb magnets CrCl3 and 𝛼−RuCl3

We report a comparative neutron single crystal diffraction study of the structural and magnetic properties of layered halides CrCl3 and 𝛼−RuCl3. They host a honeycomb arrangement of transition metal ions with distinct electronic configurations and undergo a first-order structural transition between high-temperature 𝐶⁢2/𝑚 and low-temperature 𝑅⁢‾‾‾3. Both compounds show a step-like change in the 𝑐-lattice parameter across the structure transition. In contrast, the in-plane lattice response is quite different: 𝛼−RuCl3 exhibits an abrupt hysteretic change across the transition accompanied by progressive crystalline degradation upon thermal cycling, whereas CrCl3 shows a smooth in-plane lattice evolution and remains structurally robust. Magnetically, CrCl3 orders into an A-type antiferromagnetic structure at 𝑇𝑁=14 K and exhibits pronounced diffuse magnetic scattering extending up to about 40 K. 𝛼−RuCl3 shows no observable magnetic diffuse scattering above its zigzag antiferromagnetic ordering temperature 𝑇𝑁=7.6 K. These results suggest that the contrasting structural responses arise from an interplay between interlayer sliding energetics, stacking-strain coupling, and elastic accommodation of the stacking transition. The distinct chemical bonding and electronic configurations of the two compounds provide a microscopic basis for their different lattice responses to the structure transition and magnetic correlations.

Morgan, Zachary [ORNL] (ORCID:0000000243625911)

Glauber’s Salt Composites for HVAC Applications: A Study on the Use of the T-History Method with a Modified Data Evaluation Methodology

Phase change materials (PCMs) can be utilized in buildings for peak load shifting in air conditioning systems, and the use of salt hydrate-based PCMs can reduce the cost of thermal energy storage devices. Glauber’s salt is an economical salt hydrate PCM with a melting point of around 32 °C. However, the desired melting range typically falls between 18 and 22 °C for building air conditioning applications. Although many researchers have characterized Glauber’s salt and its composites with modified melting points, enthalpy–temperature curves for composites of Glauber’s salt and NaCl are unavailable. In this study, we report the melting and solidification enthalpy–temperature curves for two different composites of Glauber’s salt and NaCl with a melting point of 21 °C obtained by the T-history method. Both composites contain NaCl to suppress the melting point, borax to reduce supercooling, and sodium polyacrylate as a thickener to enhance cyclic stability. The first composite with 12 wt.% NaCl demonstrated 139 kJ·kg−1 of latent heat of fusion, and the second composite with 9 wt.% NaCl demonstrated 171 kJ·kg−1. Both the composites have high volumetric energy densities compared to their organic counterparts with similar melting points.

Chemistry

TRACE Input Modernization

This work presents a Tom’s Obvious Minimal Language (TOML)-based representation of input for the US Nuclear Regulatory Commission’s TRAC/RELAP Advanced Computational Engine (TRACE) thermal hydraulics code. Implemented using the Workbench Analysis Sequence Processor (WASP), the approach maps traditional TRACE input structures to a hierarchical format composed of named parameters, typed values, and native data collections. The resulting representation preserves TRACE’s existing modeling capabilities while providing a modern, structured interface for model development and management. WASP further extends TOML through a file import directive that supports modular model composition and reusable input organization. In addition, WASP provides extended array data entry convenience with various data repeat and interpolation capabilities. Examples of the new TOML syntax are provided for major TRACE input categories, including hydraulic components, heat structures, control systems, and trip logic. The TOML representation establishes a foundation for improved validation, tooling, automation, and model maintainability while remaining compatible with existing TRACE workflows. To facilitate migration to the TOML-based input format, the TRACE executable now supports conversion of native TRACE input into an intermediate JSON representation. A Python utility subsequently transforms the JSON data into an equivalent TOML model. Lastly, the TRACE executable now supports execution using TOML-formatted input.

Lefebvre, Robert A. [Oak Ridge National Laboratory