Search NASASearch

SEARCH · Search NASA

Results for “time series data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

598 records · Page 27

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE

Carbon Utilization and Storage Partnership of the Western United States

This technical report documents research conducted under DOE Award No. DE-FE0031837 focused on evaluating the feasibility of carbon capture, utilization, and storage (CCUS) systems in the central and western United States. The project integrated geologic characterization, reservoir simulation, infrastructure modeling, and economic analysis to assess CO₂ storage potential near industrial sources and develop strategies for transport and sequestration. The work included subsurface modeling, risk assessment, monitoring and verification (MRV) planning, and evaluation of regulatory pathways such as EPA Underground Injection Control (UIC) Class VI permitting and IRS 45Q tax credit eligibility. Results demonstrate the viability of multiple storage approaches, including saline formations, enhanced coalbed methane recovery, and basalt mineralization, supported by data-driven workflows and regional analyses. The project also produced permitting templates, technology transfer activities, and stakeholder engagement efforts to support deployment readiness. These findings contribute to the development of scalable, economically viable CCUS systems and provide a repeatable framework for future carbon management projects.

20 FOSSIL-FUELED POWER PLANTS

Reduced Order Models for Liquid Hydrogen Pooling and Vaporization Supported by Experiments

In the event of a leak of liquid hydrogen, a pool can form that vaporizes, disperses, and eventually dilutes to a non-flammable mixture. In this work, we describe fast-running models for the pooling and vaporization of liquid hydrogen in a steady cross-wind. Several pooling models from the literature are compared to solve for the flow and extent of the pool. The size of the pool can serve as the source for a separate dispersion model, which builds upon the existing one-dimensional Gaussian plume model in HyRAM+. Additional terms for the effects of a cross-wind on momentum and entrainment were added so that the model could handle the effects of a cross-wind on a low-speed flow. The models are compared to experimental data on pooling extent and downwind dispersion for steady flow rates of liquid hydrogen in a steady cross-wind. In the two compared experiments, liquid flow rates of 15 and 45 g/s were spilled onto concrete in cross-winds of approximately 1.8 m/s. The rate of growth of the pool and the downwind concentration boundaries are compared to the models, showing good agreement, although additional tuning is needed. These models can contribute to the advancement of codes and standards for liquid hydrogen systems.

dispersion

Power performance and loads characterization of laboratory-scale cross-flow rotors fabricated using additive manufacturing

Tidal energy conversion is a relatively new application for additive manufacturing (AM), where the focus has been on fabricating axial-flow turbine blades. AM techniques add material precisely where it is needed, creating more complex shapes with less waste. Cross-flow rotor geometry presents an opportunity for AM to improve rotor performance by fabricating features that cannot be created economically via conventional manufacturing. The challenges associated with using AM in cross-flow design include water resistance and degradation over time while retaining a level of quality equivalent to conventionally machined parts. In this work, AM materials were tested by environmentally conditioning samples in a seawater tank for 5 months, followed by performance and phase-resolved load testing of laboratory-scale rotors in a hydraulic flume. We found that while metals like titanium and Inconel have excellent performance in marine environments, achieving the desired geometry and performance is difficult. Thermoplastics degraded in seawater but were easier to form into desired geometries and could exceed the performance of an aluminum control rotor. Warping and surface finish were significant detractors from AM rotor performance. These results suggest that the primary benefits of using AM for cross-flow rotors is to quickly fabricate and test unconventional rotor geometries.

16 TIDAL AND WAVE POWER

Electron-Deficient Phenazines: Synthesis, Structures, Redox, and Optoelectronic Properties in the Gas Phase, in Solution, and in the Solid State

High-temperature gas-phase reactions of 1,4-C4F8I2 with phenazine (PHNZ) afforded new thermally- and air-stable derivatives with cyclo-C4F8 substituents, viz. 1,2-PHNZ(C4F8), 2,3-PHNZ(C4F8), 1,2:6,7-PHNZ(C4F8)2, 1,2:7,8-PHNZ(C4F8)2, and 1,2:8,9-PHNZ(C4F8)2. Reactions in the presence of Cu powder resulted in reductive-defluorination/aromatization of some of the cyclo-C4F8 substituents to produce 2,3-PHNZ(C4F4), 2,3-PHNZ(C4HF3), and 1,2:6,7-PHNZ(C4F8)(C4F4), which are formally tri- or tetrafluoro derivatives of benzo[a]phenazine. Single-crystal X-ray diffraction structures of these compounds demonstrate the planarity of 2,3-PHNZ(C4F4) and 2,3-PHNZ(C4HF3) and ordered p-stacking in 1,2-PHNZ(C4HF3), 1,2-PHNZ(C4F4), 1,2-PHNZ(C4F8), and 2,3-PHNZ(C4F8). Low-temperature gas-phase photoelectron spectra of the PHNZ(C4F8)1,2 compounds show that they are strong electron acceptors, with the three PHNZ(C4F8)2 isomers having electron affinities exceeding that of C60. Cyclic voltammetry in acetonitrile show that the five PHNZ(C4F8)1,2 compounds exhibit reversible one-electron reductions with large positive shifts in their reduction potentials relative to unsubstituted PHNZ. Spectroelectrochemical absorption and EPR spectra of PHNZ(C4F8)1,2- • anion radicals and extensive DFT calculations revealed the significant role that the different substitution patterns have on determining the optoelectronic properties of the PHNZ(C4F8)1,2 derivatives and PHNZ(C4F8)1,2- • anion radicals. Time-resolved microwave conductivity measurements and photoluminescence spectra of blends of the PHNZ(C4F8)1,2 derivatives with the donor poly(3-hexylthiophene) (P3HT) were recorded to assess the possible use of the new compounds in optoelectronic devices.

Balser, Sebastian

Insights into the thermo-hydraulic properties of compacted MX80 bentonite during hydration under elevated temperature

In high-level radioactive waste geological repositories, compacted bentonite undergoes coupled thermo-hydraulic processes due to heat released from a central waste canister and groundwater imbibition from the surrounding host rock. An understanding of these processes is essential for long-term simulations of radionuclide migration and canister corrosion, which requires an understanding of temperature effects on the coupled thermo-hydraulic properties governing these processes. In this study, a tank-scale radial infiltration test was used to investigate water imbibition processes in compacted bentonite under a central heater temperature of 200 °C that simulates high thermal gradients in a repository. Interpretation of this test focuses on evaluation of the liquid water wetting front during hydration and the interpretation of the temperature-dependent transient soil water retention curve (SWRC), thermal conductivity function (TCF), and hydraulic conductivity function (HCF). The SWRC during imbibition follows a temperature-dependent wetting path. Temperature effects on the hydraulic conductivity of bentonite in saturated conditions had the greatest effect on the shape of the HCF, with minimal temperature effects at higher suctions. The transient thermal conductivity data matched well with a new TCF linked with the SWRC shape. Although the bentonite layer was restrained, local deformations during hydration may have affected the shapes of the TCF and HCF.

Engineering

Generalizable Web User Interface for Scalable and Streamlined Deployment of Building Energy Management Systems in Small and Medium-Sized Commercial Buildings

Small and medium-sized commercial buildings (SMCBs) comprise 94% of US commercial buildings yet face significant barriers to implementing building energy management systems despite advances in smart device technology. Existing solutions present critical limitations: cloud-based API solutions simplify deployment but create vendor lock-in constraints; commercial integrated software solutions ensure compatibility via standardized protocols but require substantial cost and technical expertise; open-source IoT platforms offer cost-effective vendor independence but provide insufficient standardized protocol support for commercial building automation. This research presents a generalizable web user interface framework that bridges the gap between evolving smart device capabilities and lagging software infrastructure for SMCBs. The proposed system integrates VOLTTRON open-source middleware with an automated configuration converter that transforms unified specifications written in YAML, a human-readable data-serialization format, into system-specific files, streamlining manual setup processes. The vendor-agnostic architecture supports industry-standard protocols (BACnet and Modbus) and semantic building models while providing adaptive web interfaces that dynamically adjust to various building configurations. Demonstrations through simulation-based testing and a field deployment show automatic interface adaptation across heterogeneous HVAC systems and multizone monitoring. The automated configuration converter also substantially reduces labor-intensive setup.

Chung, Jihoon [ORNL] (ORCID:0000000184880815)

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Reduced-order CFD modeling of cryogenic hydrogen isotope extrusion for pellet fueling

This study presents a reduced-order model (ROM) for computational fluid dynamics (CFD) simulations of cryogenic hydrogen isotope extrusions, focusing on protium (H₂) and deuterium (D₂) piston extruders. Using a 2D axisymmetric ROM in ANSYS-Polyflow, significant computational savings were achieved (runtime reduced from 9∼24 h to 3∼5 min), with extrusion force discrepancies between the 2D ROM and 3D models being on the order of 1%. Parametric studies identified optimal cutoff shear rates in the viscosity model (0.01/s for H₂ and 0.001/s for D₂), providing recommendations for future simulations. Finally, a comprehensive comparison of ROM results with experimental data was performed across varying geometries, cryogenic materials, temperatures, extrusion lengths, and piston velocities. Predictions at low extrusion temperatures met the objective of providing quick and efficient solutions with an acceptable extrusion force error of approximately 10% or less, validating the effectiveness of the 2D ROM approach. However, at high temperatures closer to the triple point, extrusion force error grows, which necessitates developing an improved model that accounts for temperature effects, e.g. melting. Nevertheless, the findings still represent a significant improvement in efficiency of CFD modeling of cryogenic hydrogenic extrusion. The ROM framework can also be extended to tritium (T2) and screw extruders, which will ultimately provide a fast and effective tool for optimizing pellet injector design for ITER and future reactor systems.

Fan, Joy [ORNL] (ORCID:0000000229751735)

Massive red spiral galaxies in SDSS-IV MaNGA survey

ABSTRACT Massive red spiral galaxies (MRSGs) are supposed to be the possible progenitors of lenticular galaxies (S0s). We select a large sample of MRSGs ($M_*\gt 10^{10.5}\rm {\rm M}_{\odot }$) from Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) DR17 using the g − r colour versus stellar mass diagram, along with control samples of blue spirals and S0s. Our main results are as follows: (1) After comparing the Sérsic index, concentration parameter, asymmetry parameter distribution, size–mass relation, and Σ1 (stellar mass surface density within the central 1 kpc)−mass relation, we find MRSGs are similar to S0s and have more compact and symmetric structures than blue spirals. MRSGs also resemble S0s in Dn4000, metallicity, Mgb/$\rm \left\langle Fe \right\rangle$, and V/σ radial profile. (2) By using MaNGA 2D spectra data, we separate the spatial regions into inner (R < 0.8Re) and outer (0.8 < R < 1.5Re) regions, and detect residual star formation in the outer regions of MRSGs. (3) When we select a sub-sample of MRSGs with NUV − r > 5, we find that they are completely star formation quenched in both inner and outer regions. Compared to optically selected MRSGs, NUV − r selected MRSGs appear to be more concentrated and have more massive dark matter haloes. The similarities between S0s and MRSGs suggest the possible evolutionary trend between MRSGs and S0s.

Astronomy & Astrophysics

Heat Transfer Fluids as Co‐Diluents in Localized High‐Concentration Electrolytes for High‐Rate Lithium Metal Batteries With Enhanced Safety

Localized high-concentration electrolytes (LHCEs) have been identified as promising electrolyte formulations for lithium metal batteries, due to their effective interphase formation and promotion of compact Li deposition, yet their practical implementation is often limited by reduced ion transport kinetics. In this study, two industrially established fluorinated ethers are identified for the first time in battery research as effective co-diluents as they combine a broad electrochemical stability window with a low viscosity and intrinsic non-flammability. Incorporating these components, commonly used as heat transfer fluids, yields safer, less flammable electrolyte formulations with enhanced ion mobilities. In particular, the ternary co-diluent formulation shows improved ion mobility by reducing the electrolyte's viscosity while limiting excessive ion clustering. Based on the improved electrolyte transport kinetics, lower overvoltages and higher Coulombic efficiencies at current densities ≥ 1 mA cm −2 are achieved with the ternary co-diluent blend, resulting in markedly extended cycle life in an application-oriented zero-excess pouch cell compared with the baseline system. Complementary electrochemical and ex situ analysis of harvested electrodes at moderate current densities reveals no discernible differences in interphase morphology and composition, suggesting enhanced ion mobility as the primary cause of the improved high-rate performance.

electrolyte diluent

Numerical-heating effects in atmospheric pressure streamer discharges simulated with a PIC code

Artificial heating in plasma simulations is a well-known phenomenon which occurs when, among other things, the Debye length is poorly resolved by the simulation mesh. Here, in this work, the degree to which numerical-heating occurs during a simulation of a nanosecond atmospheric pressure streamer discharge is examined. The streamer is simulated using a two-dimensional finite-element, particle-in-cell code Empire, which uses direct simulation Monte Carlo for binary particle interactions. Initially, an estimate of the numerical-heating rate applied to Empire is performed using a simple plasma model. Second, a positive atmospheric pressure streamer discharge simulation is performed to study the effects of numerical heating on plasma density, electron temperature, and streamer velocity. The nominal Debye length is approximately 1 μm and the amount of numerical heating introduced in the simulation is varied by using mesh sizes ranging from 2 μm to 20 μm. A measurable numerical heating quantity is proposed that can be used to estimate the appropriate element size and quantify the numerical-heating that can be expected over the simulation time for an atmospheric pressure streamer. In conclusion while Δx/λ D violations can be an issue it is not likely to be an issue with streamer discharges that are temporally short and occur in environments where collision frequencies are high. This result validates the rationale of grid size choices for a large amount of previously published works where Δx/λ D violation was not clearly addressed. Primary finding of this work is that numerical heating is of minor concern for plasma simulations where electron–neutral collisions are numerous such that multiple collisions can occur within a single plasma period.

Nikic, Dejan [University of New Mexico, Albuquerqu

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS

Revealing the Hidden Third Dimension of Point Defects in Two-Dimensional MXenes

Point defects govern many important functional properties of two-dimensional (2D) materials. However, resolving the three-dimensional (3D) arrangement of these defects in multi-layer 2D materials remains a fundamental challenge, hindering rational defect engineering. Here, we overcome this limitation using an artificial intelligence-guided electron microscopy workflow to map the 3D topology and clustering of atomic vacancies in Ti3C2TX MXene. Our approach reconstructs the 3D coordinates of vacancies across hundreds of thousands of lattice sites, generating robust statistical insight into their distribution that can be correlated with specific synthesis pathways. This large-scale data enables us to classify a hierarchy of defect structures-from isolated vacancies to nanopores-revealing their preferred formation and interaction mechanisms, as corroborated by molecular dynamics simulations. This work provides a generalizable framework for understanding and ultimately controlling point defects across large volumes, paving the way for the rational design of defect-engineered functional 2D materials.

2D materials

Strong Kitaev Interaction in BaCo 2⁢ (AsO 4 ) 2

The inelastic neutron scattering results and their analysis unequivocally point to a dominant Kitaev interaction in the honeycomb-lattice cobaltate BaCo 2 ⁢(AsO 4 ) 2 . Our anisotropic-exchange model closely describes all available neutron scattering data in the material’s field-polarized phase. Furthermore, the density-matrix renormalization group results for our model are in close accord with the unusual double-zigzag magnetic order and the low in-plane saturation field of BaCo 2 ⁢(AsO 4 ) 2 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Photovoltage behaviour of p-Sb 2 S 3 photocathodes for hydrogen evolution: effect of n-In 2 S 3 passivation layers

The 1.76 eV band gap of antimony(iii) sulphide (Sb 2 S 3 ) makes this semiconductor material a promising light absorber for photoelectrochemical water splitting, but scalable fabrication approaches to efficient devices are still lacking. Here we show that compact Sb 2 S 3 films on FTO can be obtained by electrochemical growth from aqueous colloidal sulphur and antimony trichloride solutions, followed by mild annealing. These films can be converted into hydrogen evolution photocathodes after coating with In 2 S 3 passivation layers and the addition of Pt proton reduction co-catalysts. For the first time, vibrating Kelvin probe surface photovoltage (VKP-SPV) spectroscopy is used to observe the carrier dynamics in such photoelectrodes. While the bare Sb 2 S 3 films suffer from high surface recombination rates and poor electron extraction, the In 2 S 3 overlayer is found to raise the photovoltage and cathodic photocurrent density, due to passivation of surface defects and formation of a p–n heterojunction. In thick In 2 S 3 films, these benefits are offset by shading and slow electron transfer. Also, we find that O 2 strongly affects the band bending in the Sb 2 S 3 –air and In 2 S 3 –air junctions and their photovoltage. The optimised devices evolve H 2 at 77.5% Faradaic efficiency and with 0.084% applied bias photon-to-current efficiency (ABPE) at 0.12 V vs. RHE. The low ABPE value is attributed to Sb 2 S 3 sub-bandgap defects visible in SPV spectra, the random orientation of Sb 2 S 3 crystallites in the films, which inhibits charge transport, the absence of crystal facets of Sb 2 S 3 , and a detrimental Schottky junction at the FTO|Sb 2 S 3 interface.

de Araújo, Moisés A. [University of California, Da

Thermal property characterization of phase change materials in building applications: A systematic review of fundamentals, recent progress, and future directions

Phase change materials (PCMs) can reduce building peak loads and enable demand-responsive thermal energy storage (TES), but their deployment depends on reliable measurement and interpretation of thermal properties across laboratory, intermediate, and application scales. Here, this review systematically examines characterization methods, testing protocols, and recent advances for neat PCMs and PCM composites, emphasizing thermal conductivity, enthalpy-related properties (phase change temperature, latent heat, specific heat), and cycling stability. For thermal conductivity, we compare steady-state and transient techniques and note limitations when phase transition and contact resistance affect measurements. For enthalpy–temperature characterization, we discuss differential scanning calorimetry together with intermediate- and bulk-scale methods, including T-history, heat flow meter testing, and three-layer calorimetry (3LC), to generate application-relevant enthalpy–temperature profiles. Cycling stability is organized into four experimental families: thermoelectric–air, fully thermoelectric, water-bath, and in situ chamber approaches, with attention to separating reversible supercooling from true degradation such as phase segregation. We highlight emerging noncontact diagnostics, including infrared thermography and embedded sensing, for spatially resolved validation and multiscale interpretation. Finally, we review the growing use of AI and machine learning for property prediction, inverse characterization from experimental signals, and real-time state estimation in building-integrated TES. Key needs include harmonized protocols, interlaboratory benchmarking, uncertainty reporting, and metadata-rich datasets to accelerate reproducible PCM qualification for grid-flexible buildings.

AI

Oxidation Chemistry of Bicarbonate and Peroxybicarbonate: Implications for Carbonate Management in Energy Storage

Carbonate formation presents a major challenge to energy storage applications based on low-temperature CO 2 electrolysis and recyclable metal–air batteries. While direct electrochemical oxidation of (bi)carbonate represents a straightforward route for carbonate management, knowledge of the feasibility and mechanisms of direct oxidation is presently lacking. Herein, we report the isolation and characterization of the bis(triphenylphosphine)iminium salts of bicarbonate and peroxybicarbonate, thus enabling the examination of their oxidation chemistry. Infrared spectroelectrochemistry combined with time-resolved infrared spectroscopy reveals that the photoinduced oxidation of HCO 3 – by an Ir(III) photoreagent results in the generation of the short-lived bicarbonate radical in less than 50 ns. The highly acidic bicarbonate radical undergoes proton transfer with HCO 3 – to furnish the carbonate radical anion and H 2 CO 3 , leading to the eventual release of CO 2 and H 2 O, thus accounting for the appearance of H 2 O and CO 2 in both electrochemical and photochemical oxidation experiments. Here, the back reaction of the carbonate radical subsequently oxidizes the Ir(II) photoreagent, leading to carbonate. In the absence of this back reaction, dimerization of the carbonate radical provides entry into peroxybicarbonate, which we show undergoes facile oxidation to O 2 and CO 2 . Together, the results reported identify tangible pathways for the design of catalysts for the management of carbonate in energy storage applications.

25 ENERGY STORAGE