Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 487 records · Page 27

Liquid Nitrogen (Oxygen Simulent) Thermodynamic Venting System Test Data Analysis

In designing systems for the long-term storage of cryogens in low gravity space environments, one must consider the effects of thermal stratification on excessive tank pressure that will occur due to environmental heat leakage. During low gravity operations, a Thermodynamic Venting System (TVS) concept is expected to maintain tank pressure without propellant resettling. The TVS consists of a recirculation pump, Joule-Thomson (J-T) expansion valve, and a parallel flow concentric tube heat exchanger combined with a longitudinal spray bar. Using a small amount of liquid extracted by the pump and passing it though the J-T valve, then through the heat exchanger, the bulk liquid and ullage are cooled, resulting in lower tank pressure. A series of TVS tests were conducted at the Marshall Space Flight Center using liquid nitrogen as a liquid oxygen simulant. The tests were performed at fill levels of 90%, 50%, and 25% with gaseous nitrogen and helium pressurants, and with a tank pressure control band of 7 kPa. A transient one-dimensional model of the TVS is used to analyze the data. The code is comprised of four models for the heat exchanger, the spray manifold and injector tubes, the recirculation pump, and the tank. The TVS model predicted ullage pressure and temperature and bulk liquid saturation pressure and temperature are compared with data. Details of predictions and comparisons with test data regarding pressure rise and collapse rates will be presented in the final paper.

Hedayat, A.↗

Pressure cells for in situ neutron total scattering: time and real-space resolution during deuterium absorption

In situ gas-loading sample holders for two-dimensionally arranged detectors in time-of-flight neutron total scattering experiments have been developed to investigate atomic arrangements during deuterium absorption using time and real-space resolution. A single-crystal sapphire container was developed that allows conditions of 473 K and 10 MPa hydrogen gas pressure. High-resolution transient measurements detected deuterium absorption by palladium that proceeded within a few seconds. A double-layered container with thick- and thin-walled vanadium allowed conditions of 423 K and 10 MPa hydrogen gas pressure. The deuterium occupation sites of a lanthanum–nickel–aluminium alloy are discussed in detail on the basis of real-space high-resolution data obtained from in situ neutron scattering measurements and reverse Monte Carlo structural modeling.

08 HYDROGEN↗

Cathode Electrolyte Diagnostics Based on Scanning Probe Microscopy

Various processes lead to degradation of cathodes in lithium-ion batteries. Questions remain regarding mechanisms of many of these processes. Probe microscopy methods including scanning electrochemical microscopy (SECM) are capable of directly probing processes at the cathode/electrolyte interface. SECM uses a small electrode to perform rapid electrochemical analysis of transient species generated at an active cathode/electrolyte interface. This paper discusses the background of the SECM instrument and its application to lithium-ion battery research. We also describe the application of SECM methods to the study of cathode degradation processes observed in lithium-ion batteries. Specifically, we focus on characterizing the dissolution of manganese from LiMn2O4 (LMO) based on recent debate in the literature. We describe experiments to observe and characterize the electrochemical properties of manganese complexes emerging from degrading LMO electrode materials.

cathode/electrolyte interface↗

Improving Subsurface Stress Characterization for Carbon Dioxide Storage Projects by Incorporating Machine Learning Techniques

The overall objective of this project is to develop a framework for reliable characterization and prediction of the state of stress in the overburden and underburden (including the basement) in CO 2 storage reservoirs using machine learning and integrated geomechanics and geophysical methods. Specifically, we propose to develop workflow encompassing of technologies and/or methods to predict stress and pressure changes due to CO 2 injection in an active tertiary recovery site and their impacts on subtle fault activation, fractures and occurrence of microseismic events and compare responses to field observations. In this project, we anticipate using dataset from the Farnsworth field Unit (FWU) which is operated by Purdure Petroleum. A novel elastic-waveform VSP inversion technique will be used to estimate high-resolution spatial and temporal changes of elastic moduli in CO 2 storage reservoirs, which will be combined with velocity-stress relationship derived from laboratory tests to obtain subsurface pressure and stress. Clustered microseismic data will be jointly inverted for improved focal mechanisms. Least-squares reverse-time migration of microseismic waveform data will be performed to directly image fracture/fault zones. Additionally, a deep neural network machine learning technique with convolutional and recurrent layers will be used for learning the spectro-temporal structures in microseismic waveforms. The results of this geotechnical data analysis will be integrated to develop a high-resolution 3D mechanical earth model extending from the overburden sealing formations to the underburden including the basement. Mechanical properties will be derived through integration of mechanical logs, tests, available results from chemo-mechanical laboratory tests, and elastic inversion of seismic data using a combination of Bayesian and stochastic methods as well as machine learning technique. Failure features (faults/fractures) will be represented and/or modeled based on seismic and core data analysis. A transient hydrodynamic-geomechanical model will be developed through coupling with the calibrated FWU reservoir simulation model. The full physics coupled model will be used to train a reduced order proxy model using machine learning algorithm for estimating stress which will then be used with appropriate constitutive relationships and forward seismological models to simulate pressure changes and induced microseismicity. An advanced optimization framework will be developed to perform a history match to minimize error between field observations and simulated. The history matched proxy model will be verified against the full-physics equivalent. The field observations that will be used in the coupled model calibration process include pressure/stress inverted from VSP, moment magnitude from microseismic analysis, real time downhole pressure measurements, production and injection data. Parameter sensitivity and uncertainty analysis will be performed to characterize the impact of model parameter uncertainty on stress estimates. The proposed project will have significant impact on future field implementation of the proposed technology. Because the project field site is an ongoing CO 2 EOR development, the value of the new technology will be demonstrated in an operational context and evaluated as a viable risk mitigation strategy. Cost/benefit will be evaluated together with the various commercial incentives for CO 2 sequestration available to oil and gas operators. The extensive available dataset and ongoing data acquisition under the SWP Phase III work plan provides flexibility for investigation of multiple approaches and reduces technical risk.

58 GEOSCIENCES↗

Data Relay Board with Protocol for High-Speed, Free-Space Optical Communications

In a free-space optical communication system, the mitigation of transient outages through the incorporation of error-control methods is of particular concern, the outages being caused by scintillation fades and obscurants. The focus of this innovative technology is the development of a data relay system for a reliable high-data-rate free-spacebased optical-transport network. The data relay boards will establish the link, maintain synchronous connection, group the data into frames, and provide for automatic retransmission (ARQ) of lost or erred frames. A certain Quality of Service (QoS) can then be ensured, compatible with the required data rate. The protocol to be used by the data relay system is based on the draft CCSDS standard data-link protocol Proximity-1, selected by orbiters to multiple lander assets in the Mars network, for example. In addition to providing data-link protocol capabilities for the free-space optical link and buffering the data, the data relay system will interface directly with user applications over Gigabit Ethernet and/or with highspeed storage resources via Fibre Channel. The hardware implementation is built on a network-processor-based architecture. This technology combines the power of a hardware switch capable of data switching and packet routing at Gbps rates, with the flexibility of a software- driven processor that can host highly adaptive and reconfigurable protocols used, for example, in wireless local-area networks (LANs). The system will be implemented in a modular multi-board fashion. The main hardware elements of the data relay system are the new data relay board developed by Rockwell Scientific, a COTS Gigabit Ethernet board for user interface, and a COTS Fibre Channel board that connects to local storage. The boards reside in a cPCI back plane, and can be housed in a VME-type enclosure.

Wright, Malcolm↗

Control Co-Design Framework for Joint Optimization of PID Governor and Hydraulic Dynamics for a Hydropower Plant

This paper presents a control co-design (CCD) framework tailored to the hydraulic and mechanical subsystems of hydropower systems, aimed at enhancing their dynamic performance and responsiveness to grid demands. Conventional sequential design approaches often fall short in capturing the coupled interactions between plant dynamics and control objectives. The proposed CCD methodology enables simultaneous optimization of key hydro plant parameters - such as governor settings, penstock characteristics, and valve control - with the control system architecture. Results indicate that both CCD and sequential design approaches achieve comparable transient and steady-state performance, with minor discrepancies arising from differences in their optimized parameters. However, CCD demonstrates a distinct advantage by tripling the water time constant (Tw) while maintaining similar dynamic performance to the sequential approach. This increase in Tw enables optimization of penstock dimensions, as it is directly influenced by penstock design, thereby contributing to overall cost optimization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Zero Boil-Off Tank Experiment Ground Testing and Verification of Fluid and Thermal Performance

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale International Space Station (ISS) experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the work that has been done to demonstrate that the ZBOT experiment is capable of performing the functions required to produce a meaningful and accurate results, prior to its launch to the International Space Station. Main systems discussed are expected to include the thermal control system, the optical imaging system, and the tank filling system.This work is sponsored by NASAs Human Exploration Mission Directorates Physical Sciences Research program.

Fluid management↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.

Keddy, E.↗

THERMAL STRESS ANALYSIS OF A SPENT NUCLEAR FUEL CANISTER

The potential for chloride induced stress corrosion cracking (CISCC) in spent nuclear fuel dry storage canisters is a current topic of research by the US Department of Energy Spent Fuel and Waste Science and Technology program. One of the important prerequisites for CISCC is a tensile residual stress state. This study utilizes computational models to provide an initial analysis of thermal stresses in a generic spent nuclear fuel canister. A STAR-CCM+ thermal fluid model provides a temperature profile analysis of the canister based on four different ambient temperature conditions. An ANSYS APDL finite element model incorporates the temperature profiles to analyze the thermal stresses in the canister. The calculated thermal stress magnitudes are in the range of 10 MPa to 80 MPa, which could be significant for crack propagation through the canister wall. The maximum thermal stress is not a concern for the structural failure of the canister, but it is high enough that it is a significant contribution to the total stress state of the canister wall, which also includes residual stress from fabrication, internal pressure from helium cover gas, and potential transient mechanical loads, such as earthquakes. This paper describes the initial finite element thermal stress analysis that was completed in 2020, reports the initial findings, and identifies areas where model refinement is still needed to complete this work in the future.

Jensen, Ben J.↗

Simulation of Propellant Loading System Senior Design Implement in Computer Algorithm

Propellant loading from the Storage Tank to the External Tank is one of the very important and time consuming pre-launch ground operations for the launch vehicle. The propellant loading system is a complex integrated system involving many physical components such as the storage tank filled with cryogenic fluid at a very low temperature, the long pipe line connecting the storage tank with the external tank, the external tank along with the flare stack, and vent systems for releasing the excess fuel. Some of the very important parameters useful for design purpose are the prediction of pre-chill time, loading time, amount of fuel lost, the maximum pressure rise etc. The physics involved for mathematical modeling is quite complex due to the fact the process is unsteady, there is phase change as some of the fuel changes from liquid to gas state, then conjugate heat transfer in the pipe walls as well as between solid-to-fluid region. The simulation is very tedious and time consuming too. So overall, this is a complex system and the objective of the work is student's involvement and work in the parametric study and optimization of numerical modeling towards the design of such system. The students have to first become familiar and understand the physical process, the related mathematics and the numerical algorithm. The work involves exploring (i) improved algorithm to make the transient simulation computationally effective (reduced CPU time) and (ii) Parametric study to evaluate design parameters by changing the operational conditions

Bandyopadhyay, Alak↗

Tailoring Electrochemical CO 2 Reduction on Copper by Reactive Ionic Liquid and Native Hydrogen Bond Donors

Electrochemical CO 2 reduction (CO 2 RR) on copper (Cu) shows promise for higher-value products beyond CO. However, challenges such as the limited CO 2 solubility, high overpotentials, and the competing hydrogen evolution reaction (HER) in aqueous electrolytes hinder the practical realization. We propose a functionalized ionic liquid (IL) which generates ion-CO 2 adducts and a hydrogen bond donor (HBD) upon CO 2 absorption to modulate CO 2 RR on Cu in a non-aqueous electrolyte. As revealed by transient voltammetry, electrochemical impedance spectroscopy (EIS), and in situ surface-enhanced Raman spectroscopy (SERS) complemented with image charge augmented quantum-mechanical/molecular mechanics (IC-QM/MM) computations, a unique microenvironment is constructed. In this microenvironment, the catalytic activity is primarily governed by the IL and HBD concentrations; former controlling the double layer thickness and the latter modulating the local proton availability. This translates to ample CO 2 availability, reduced overpotential, and suppressed HER where C 4 products are obtained. This study deepens the understanding of electrolyte effects in CO 2 RR and the role of IL ions towards electrocatalytic microenvironment design.

25 ENERGY STORAGE↗

A Short-lived Three-Belt Structure for sub-MeV Electrons in the Van Allen Belts: Time Scale and Energy Dependence

In this study we focus on the radiation belt dynamics driven by the geomagnetic storms during September 2017. Besides the long-lasting three-belt structures of ultrarelativistic electrons (>2 MeV, existing for tens of days), which has been studied intensively during the Van Allen Probe era, it is found that magnetospheric electrons of hundreds of keVs can also have three-belt structures at similar L extent during storm time. Measurements of 500–800 keV electrons from MagEIS instrument onboard Van Allen Probes show double-peaked (L = 3.5 and 4.5, respectively) flux-versus-L-shell profile in the outer belt, which lasted for 2–3 days. During the time interval of such transient three-belt structure, the energy-versus-L spectrogram shows novel distributions differing from both “S-shaped” and “V-shaped” spectrograms reported previously. Such peculiar distribution also illustrates the energy-dependent occurrence of the three-belt profile. Furthermore, the gradual formation of “reversed energy spectrum” at L ~ 3.5 also indicates that hiss scattering inside the plasmapause contributed to the fast decay of sub-MeV remnant belt.

79 ASTRONOMY AND ASTROPHYSICS↗

KOH vs Deionized Water Operation in Anion Exchange Membrane Electrolyzers

Anion exchange membrane water electrolyzers (AEMELs) have recently received significant attention due to their potential advantages over proton exchange membrane electrolyzers (PEMELs). However, some AEMELs feed an aqueous salt solution to the cell where PEMELs typically feed deionized (DI) water. DI water is preferred to keep the system and maintenance costs low. Because of this, many AEMEL researchers report performance both in the salt solution (typically KOH) and DI water. However, the methodology for switching between KOH and DI water is often poorly defined, and it is unclear what impact the residual salt has on cell performance after switching from salt to DI water. Having a fully deionized environment is important because the presence of salts in the water feed increase the effective electrochemical surface area of the catalyst in the three-dimensional electrode and residual salt remaining after switching to DI water feed can have a misleading transient effect on cell performance. This paper focuses on understanding the transition from KOH to DI water testing in AEMELs. It is shown that when switching from salt to DI water feed, a large volume of DI water must be fed over several hours to achieve true DI-water performance. It is also shown that starting AEMELs from the beginning with DI water feed (without any KOH ever being fed to the cell) results in better cell durability. Lastly, a cell is demonstrated having operated exclusively on DI water at 1.0 A cm −2 for 500 h at an operating voltage of ca. 2 V and a low degradation rate.

08 HYDROGEN↗

Organic Direct-Bonded-Copper-Based Rapid Prototyping for Silicon Carbide Power Module Packaging

Silicon carbide (SiC) power devices are playing ever- growing roles in high-power-density power electronics converters by offering benefits such as high voltage rating, fast transients, and high thermal performance. Organic direct-bonded copper (ODBC)-based packaging, due to its ductility and ease of han- dling, allows the possibility of a more flexible layout design that may better tap the potential of SiC benefits. In this work, an ODBC-based prototyping routine is developed that accelerates the iterations of packaging layout design with low cost. The properties of ODBC and its handling are briefly introduced, and tools and fabrication steps are explained. Following this routine, a 1.2-kV SiC half-bridge power module is designed and fabricated with the focus on sub-nanohenry ultra-low loop inductance. Simulation and experimental validation are also conducted.

25 ENERGY STORAGE↗

Predicting Cement-Sheath Integrity with Consideration of Initial State of Stress and Thermoporoelastic Effects

In conventional wellbore-integrity analysis, the cement sheath’s initial state of stress and transient thermoporoelastic effects are often neglected. However, the initial state of stress is prerequisite information for accurately predicting the safe operating conditions that prevent a cemented well from being damaged. In addition, transient thermoporoelastic effects can have a profound effect on when damage will occur. Here in this paper, we propose a model that includes these effects to predict the safe operating pressures and temperatures that will prevent cement-sheath failure. For the initial state of stress, we proposed an empirical model using measurements. Subsequent stress changes are evaluated by a fully coupled transient thermoporoelastic model to analyze the mechanical behavior of the cement sheath. We predict the safe operating envelope (SOE) for shear, tensile, and debonding cement-sheath failures caused by pressure and temperature perturbations after the cement sets. Our model predicts that pore pressure is a key factor for cement failure, especially for rapid temperature changes. If the formation is low permeability, the transient pore pressures are amplified, causing the risk of damage to increase. Compared with conventional thermoelastic models, the thermoporoelastic model predicts a smaller SOE when heating the internal casing fluid and a larger envelope when cooling the internal casing fluid. Finally, the heating rate was considered with respect to field applications. The heating rate was also considered, and slower heating/cooling rates can prevent damage to the cement sheath. Finally, the thermoporoelastic model was applied to explain several laboratory and field experiments and achieved good matches.

02 PETROLEUM↗

In Situ Visualization of the Pinning Effect of Planar Defects on Li Ion Insertion

Longevity of Li ion batteries strongly depends on the interaction of transporting Li ions in electrode crystals with defects. However, detailed interactions between the Li ion flux and structural defects in the host crystal remain obscure due to the transient nature of such interactions. Here, by in situ transmission electron microscopy and density function theory calculations, we reveal how the diffusion pathways and transport kinetics of a Li ion can be affected by planar defects in a tungsten trioxide lattice. We uncover that changes in charge distribution and lattice spacing along the planar defects disrupt the continuity of ion conduction channels and dramatically increase the energy barrier of Li diffusion, thus, arresting Li ions at the defect sites and twisting the lithiation front. In conclusion, the atomic-scale understanding holds critical implications for rational interface design in solid-state batteries and solid oxide fuel cells.

25 ENERGY STORAGE↗

An Electrochemically Activated Nanofilm for Sustainable Mg Anode with Fast Charge Transfer Kinetics

Highly reversible Mg plating/stripping is key for rechargeable Mg batteries and has typically been successfully demonstrated using transient electrochemical techniques such as cyclic voltammetry measurements. Furthermore, little effort has been invested in studying the stability of the electrode/electrolyte interface over an extended time. We report here the development of an in situ generated surface film for Mg anodes based on electrodeposited bismuth (E_Bi). This film improves the interfacial stability of Mg in contact with the electrolyte, particularly over an extended time, and possesses fast charge-transfer kinetics (<30 Ω∙cm 2 ) and low non-time-sensitive interfacial film resistance (ca. 5 Ω∙cm 2 ) for active Mg species.

25 ENERGY STORAGE↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗