Search NASA⌕ Search

SEARCH · Search NASA

Results for “CE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Nonsymmorphic symmetry and field-driven odd-parity pairing in Ce Rh 2 As 2

Recently, evidence has emerged for a field-induced even- to odd-parity superconducting phase transition in CeRh 2 As 2 . In this paper we argue that the P4/nmm nonsymmorphic crystal structure of CeRh 2 As 2 plays a key role in enabling this transition by ensuring large spin-orbit interactions near the Brillouin zone boundaries, which naturally leads to the required near-degeneracy of the even- and odd-parity channels. We further comment on the relevance of our theory to FeSe, which crystallizes in the same structure.

36 MATERIALS SCIENCE↗

Searching for the origin of the rare-earth peak with precision mass measurements across Ce–Eu isotopic chains

A nuclear mass survey of rare-earth isotopes has been conducted with the Canadian Penning Trap mass spectrometer using the most neutron-rich nuclei thus far extracted from the CARIBU facility. Here, we present a collection of 12 nuclear masses determined with a precision of ≤ 10 keV/c 2 for Z = 58-63 nuclei near N = 100. Independently, a detailed study exploring the role of nuclear masses in the formation of the r-process rare-earth abundance peak has been performed. Employing a Markov chain Monte Carlo (MCMC) technique, mass predictions of lanthanide isotopes have been made which uniquely reproduce the observed solar abundances near A = 164 under three distinct astrophysical outflow conditions. We demonstrate that the mass surface trends thus far mapped out by our measurements are most consistent with MCMC mass predictions given an r process that forms the rare-earth peak during an extended (n, γ) ⇌ (γ, n) equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Aerosol Synthesis of Highly Dispersed Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+} Phosphor with Intense Photoluminescence

A simple method of pyrolysis of an aerosol solution of yttrium, aluminum, and cerium nitrates with the addition of urea or citric acid, followed by brief annealing, is developed to obtain a highly dispersed aluminum–yttrium garnet powder that demonstrates intense photoluminescence in the visible light region. Characterization of the synthesized samples (photoluminescence spectra, X-ray diffraction analysis, Raman spectra) showed that intense photoluminescence is achieved only in a narrow window of process conditions, namely, the concentration of nitrate solution and the concentration of citric acid or urea. The photoluminescence intensity increases upon annealing synchronously with an increase in the crystallite size, which, along with the optimal cerium concentration (~0.5 at %), is a determining factor for obtaining high-quality samples. The synthesized powders had intense photoluminescence and high optical perfection, as evidenced by the observation of whispering gallery modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Positron beams at Ce+BAF

Positron beams would provide a new and meaningful probe for the experimental program at the Thomas Jefferson National Accelerator Facility (JLab). The JLab Positron Working Group, formed in 2018 and now with over 250 members from 75 institutions, continues to develop an experimental program with high duty-cycle positron beams including but not limited to future hadronic physics and dark matter experiments. Critical requirements involve generating positron beams with a high degree of spin polarization, sufficient intensity and a continuous-wave (CW) bunch train compatible with acceleration to 12 GeV at the Continuous Electron Beam Accelerator Facility (CEBAF). In this presentation we describe a start-to-end layout for positron beams at 12 GeV CEBAF utilizing the Low Energy Research Facility (LERF) at Jefferson Lab to build two new injectors. A GaAs dc high voltage photo-gun first generates >1 mA of polarized electrons which are then accelerated to 80-150 MeV and directed to a high-power spinning W target for polarized bremsstrahlung and positron pair creation. A second injector then collects, bunches and accelerates the positrons to 123 MeV. The positron beams are transported by a new beam line and injected into the CEBAF acceptance for acceleration to the end stations with energies up to 12 GeV. The layout is optimized to provide Users with positron spin polarization >60% and intensity greater than >100 nA, and with higher intensities when polarization is not required.

Benesch, J.↗

Capture Cavities for the CW Polarized Positron Source Ce+BAF

The initial design of the capture cavities for a continuous wave (CW) polarized positron beam for the Continuous Electron Beam Accelerator Facility (CEBAF) up-grade at Jefferson Lab is presented. A chain of standing wave multi-cell copper cavities inside a solenoid channel are selected to capture positrons in CW mode. The cavity shunt impedance is surveyed by tuning the cavity geometry while considering accommodating large phase space distribution positron beams with large beam pipe radius while ensuring a large enough passband mode separation. The RF field wall loss power and maximum wall loss power density are considered in cavity and waveguide design. A range of design parameters are given for larger system optimization when the capture cavities are considered together with thermal calculation and beam dynamics in next phase of work.

Wang, S.↗

Toward a long-lifetime polarized photoelectron gun for the Ce+BAF positron source

The addition of spin-polarized, continuous-wave (c.w.) positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) would provide a significant capability to the experimental nuclear physics program at Jefferson Lab. Based on bremsstrahlung and pair-production in a high-Z target, the positron source requires a 120 MeV spin-polarized c.w. electron beam of several milliamperes. While the beam dynamics of the high-current electron beam are tenable, sustaining this current for weeks of user operations requires an unprecedented charge lifetime from a high-polarization GaAs-based photocathode. A promising approach to exceed the kilocoulomb charge lifetime barrier is reducing the ion back-bombardment fluence at the photocathode. By increasing the laser size and managing the emittance growth with an adequate cathode/anode design, significantly enhanced charge lifetime may be achieved. Based upon a new simulation model that qualitatively explains the lifetime data previously measured at different spot sizes, we describe the practical implications on the parameter space available for a kilocoulomb-lifetime polarized photogun design.

Bruker, M.↗

Magnetic properties of Lu and Y doped Ce-Fe-B magnets

The growing demand for Nd2Fe14B magnets is exacerbating the current critical materials shortage. To reduce the amount of critical material in Nd2Fe14B magnets, chemical substitutions have been used and shown to improve the magnetic behavior, such as the Curie Temperature TC, anisotropy field Ha, and saturation magnetization MS.

Bretana, Alex↗

Toward a long-lifetime polarized photoelectron gun for the Ce+BAF positron source

The addition of spin-polarized, continuous-wave (c.w.) positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF) would provide a significant capability to the experimental nuclear physics program at Jefferson Lab. Based on bremsstrahlung and pair-production in a high-Z target, the positron source requires a 120 MeV spin-polarized c.w. electron beam of several milliamperes. While the beam dynamics of the high-current electron beam are tenable, sustaining this current for weeks of user operations requires an unprecedented charge lifetime from a high-polarization GaAs-based photocathode. A promising approach to exceed the kilocoulomb charge lifetime barrier is reducing the ion back-bombardment fluence at the photocathode. By increasing the laser size and managing the emittance growth with an adequate cathode/anode design, significantly enhanced charge lifetime may be achieved. Based upon a new simulation model that qualitatively explains the lifetime data previously measured at different spot sizes, we describe the practical implications on the parameter space available for a kilocoulomb-lifetime polarized photogun design.

Bruker, M.↗

Status of the Ce+BAF project

Jefferson Lab is proposing to add positron beams to the 12 GeV Continuous Electron Beam Accelerator Facility (CEBAF). A team of accelerator and nuclear scientists was formed in 2018 to develop the physics case as well as a concept for the generation, production and delivery of Continuous (CW) polarized positron beams to the experimental halls, up to the full 12 GeV. A layout of the proposed concept will be shown. We will report on the ongoing efforts in the positron generation and capture, target design, beam transport and expected properties of the e+ beam on the experimental targets at 12GeV. This project is supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177

Roblin, Yves↗