Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Interconnection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Distributed Conditions for Small-signal Stability of Power Grids and Local Control Design

Operating modern power grids with stability guarantees is markedly important. Typical methods for analyzing and certifying power grid stability are largely centralized relying on the ability of the system operator to gather network-wide information and accurately compute the system's eigenvalues. These methods are oftentimes not privacy-preserving and computationally burdensome. They are therefore, not well-suited to modern power grids where small-signal stability has to be evaluated timely, efficiently and in a privacy-preserving fashion. Herein, we introduce a distributed methodology for certifying small-signal stability of power grids and designing the local controllers. First, we analytically derive distributed conditions for network-wide stability that bus agents can inspect using local information. By leveraging these conditions, we then introduce a distributed control design algorithm (DCDA) that can guide the local control design so that stability of the interconnected system is guaranteed. The agents that adopt the proposed distributed algorithm are responsible for tuning their local controllers, producing their local control commands and ensuring that their local stability condition is met. The system operator is only responsible for verifying network-wide stability upon receiving affirmative responses from all agents and, announcing, that the overall system is stable. The proposed DCDA algorithm is numerically validated via simulations using the IEEE 39-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The value of fusion energy to a decarbonized United States electric grid

Fusion could be a part of future decarbonized electricity systems, but it will need to compete with other technologies. In particular, pulsed tokamak plants have a unique operational mode, and evaluating which characteristics make them economically competitive can help select between design pathways. Using a capacity expansion and operations model, here we determined cost thresholds for pulsed tokamaks to reach a range of penetration levels in a future decarbonized US Eastern Interconnection. The required capital cost to reach a fusion capacity of 100 GW varied from $2,700 to $7,500 kW -1 , and the equilibrium penetration increases rapidly with decreasing cost. The value per unit power capacity depends on the variable operational cost and on the cost of its competition, particularly fission, much more than on the pulse cycle parameters. These findings can therefore provide initial cost targets for fusion more generally in the United States.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recommendations for Data-in-Transit Requirements for Securing DER Communications

With the adoption of Distributed Energy Resource (DER) interoperability standards, common communication protocols are now being deployed between power system operators and DER devices. In 2018, a revision to the US interconnection and interoperability standard, Institute of Electrical and Electronics Engineers (IEEE) Std. 1547, required DER equipment to have an IEEE 2030.5, IEEE 1815, or SunSpec Modbus communication exchange interface. This change supports the future transition to secure connection and exchange of information between the DER equipment and implementing parties, such as grid operators. Adoption of standardized communication protocols and associated information models is a critical step toward interoperability between power system operators and DER, such as photovoltaic (PV) and energy storage systems. However, security requirements for these standardized communication protocols are not comprehensive, resulting in non-standard and vendor-specific implementation that may leave DER equipment susceptible to cyberattacks. This paper examines the data-in-flight security requirements for standardized DER communication protocols, per IEEE 1547-2018 revision, as it relates to device authentication, key management, and encryption. The state of the art for these security features is also explored, addressing their impact on communication and performance of low-cost single board computers, which are typical of DER devices. In conclusion, a recommendation is provided to adopt a common set of communication requirements, which are intended to achieve interoperability and implement data security over DER network pathways, while ensuring reliable, secure, and real-time information delivery.

42 ENGINEERING↗

Remote Asynchronous Message Service Gateway

The Remote Asynchronous Message Service (RAMS) gateway is a special-purpose AMS application node that enables exchange of AMS messages between nodes residing in different AMS "continua," notionally in different geographical locations. JPL s implementation of RAMS gateway functionality is integrated with the ION (Interplanetary Overlay Network) implementation of the DTN (Delay-Tolerant Networking) bundle protocol, and with JPL s implementation of AMS itself. RAMS protocol data units are encapsulated in ION bundles and are forwarded to the neighboring RAMS gateways identified in the source gateway s AMS management information base. Each RAMS gateway has interfaces in two communication environments: the AMS message space it serves, and the RAMS network - the grid or tree of mutually aware RAMS gateways - that enables AMS messages produced in one message space to be forwarded to other message spaces of the same venture. Each gateway opens persistent, private RAMS network communication channels to the RAMS gateways of other message spaces for the same venture, in other continua. The interconnected RAMS gateways use these communication channels to forward message petition assertions and cancellations among themselves. Each RAMS gateway subscribes locally to all subjects that are of interest in any of the linked message spaces. On receiving its copy of a message on any of these subjects, the RAMS gateway node uses the RAMS network to forward the message to every other RAMS gateway whose message space contains at least one node that has subscribed to messages on that subject. On receiving a message via the RAMS network from some other RAMS gateway, the RAMS gateway node forwards the message to all subscribers in its own message space.

Wang, Shin-Ywan↗

Control co-design under uncertainty for offshore wind farms: Optimizing grid integration, energy storage, and market participation

Offshore wind farms (OWFs) are set to significantly contribute to global decarbonization efforts. Developers often use a sequential approach to optimize design variables and market participation for grid-integrated offshore wind farms. However, this method can lead to sub-optimal system performance, and uncertainties associated with renewable resources are often overlooked in decision-making. Here, this paper proposes a control co-design approach, optimizing design and control decisions for integrating OWFs into the power grid while considering energy market and primary frequency market participation. Additionally, we introduce optimal sizing solutions for energy storage systems deployed onshore to enhance revenue for OWF developers over time. This framework addresses uncertainties related to wind resources and energy prices. We analyze five U.S. west-coast offshore wind farm locations and potential interconnection points, as identified by the Bureau of Ocean Energy Management (BOEM). Results show that optimized control co-design solutions can increase market revenue by 3.2% and provide flexibility in managing wind resource uncertainties.

Control Co-design↗

Getting to 95

Members of the Tennessee Valley Public Power Association (TVPPA) have the opportunity to interconnect up to 5% of their annual energy requirements in self generation. TVA, their wholesale supplier, is encouraging solar. This presentation introduces IEEE 1547 2018 and provides some high level information on solar cost.

DER↗

Bilevel Nodal Behind-the-meter Solar Disaggregation Under Unexpected Extreme Weather Conditions

As the power grid undergoes significant paradigm shift due to the increasing penetration of renewable generation, the ever-growing installation of behind-the-meter (BTM) solar generation in the power grid also has a significant impact on nodal loads, posing challenges on transmission operators. Furthermore, increasing frequent and severe extreme weather events intertwine with ubiquitous BTM solar generations and have amplified the challenges of accurately model nodal load profiles, especially under the lack of ground-truth information for verification. To tackle these challenges, this paper introduces a bilevel model that utilizes year-long data (e.g., proxy solar, zonal load, and individual node load profiles) to disaggregate metered profiles into actual demand and BTM solar generation at each transmission node. The proxy solar not only scales the BTM solar generation of individual nodes but also create a compensation term for enhancing performance on days with unexpected extreme weather events. The proposed algorithm is validated with real-world PJM Interconnection data during unexpected events like the recent Winter Storm Elliott. For quantitative evaluations, a novel Score error is introduced, which is based on mean percentages and load scales and offers a universal assessment method suitable for all nodes and different data formats (e.g., normalized or raw values).

behind-the-meter solar, load disaggregations, load↗

SpaceCube v2.0 Space Flight Hybrid Reconfigurable Data Processing System

This paper details the design architecture, design methodology, and the advantages of the SpaceCube v2.0 high performance data processing system for space applications. The purpose in building the SpaceCube v2.0 system is to create a superior high performance, reconfigurable, hybrid data processing system that can be used in a multitude of applications including those that require a radiation hardened and reliable solution. The SpaceCube v2.0 system leverages seven years of board design, avionics systems design, and space flight application experiences. This paper shows how SpaceCube v2.0 solves the increasing computing demands of space data processing applications that cannot be attained with a standalone processor approach.The main objective during the design stage is to find a good system balance between power, size, reliability, cost, and data processing capability. These design variables directly impact each other, and it is important to understand how to achieve a suitable balance. This paper will detail how these critical design factors were managed including the construction of an Engineering Model for an experiment on the International Space Station to test out design concepts. We will describe the designs for the processor card, power card, backplane, and a mission unique interface card. The mechanical design for the box will also be detailed since it is critical in meeting the stringent thermal and structural requirements imposed by the processing system. In addition, the mechanical design uses advanced thermal conduction techniques to solve the internal thermal challenges.The SpaceCube v2.0 processing system is based on an extended version of the 3U cPCI standard form factor where each card is 190mm x 100mm in size The typical power draw of the processor card is 8 to 10W and scales with application complexity. The SpaceCube v2.0 data processing card features two Xilinx Virtex-5 QV Field Programmable Gate Arrays (FPGA), eight memory modules, a monitor FPGA with analog monitoring, Ethernet, configurable interconnect to the Xilinx FPGAs including gigabit transceivers, and the necessary voltage regulation. The processor board uses a back-to-back design methodology for common parts that maximizes the board real estate available. This paper will show how to meet the IPC 6012B Class 3A standard with a 22-layer board that has two column grid array devices with 1.0mm pitch. All layout trades such as stack-up options, via selection, and FPGA signal breakout will be discussed with feature size results. The overall board design process will be discussed including parts selection, circuit design, proper signal termination, layout placement and route planning, signal integrity design and verification, and power integrity results. The radiation mitigation techniques will also be detailed including configuration scrubbing options, Xilinx circuit mitigation and FPGA functional monitoring, and memory protection.Finally, this paper will describe how this system is being used to solve the extreme challenges of a robotic satellite servicing mission where typical space-rated processors are not sufficient enough to meet the intensive data processing requirements. The SpaceCube v2.0 is the main payload control computer and is required to control critical subsystems such as autonomous rendezvous and docking using a suite of vision sensors and object avoidance when controlling two robotic arms.

Xilinx FPGA↗

The North American Renewable Integration Study (NARIS): A U.S. Perspective

The North American electric power system is undergoing significant change, with renewable resources now contributing more generation than ever before. This transformation is poised to continue given decreasing technology costs and ambitious decarbonization goals at the federal, state, local, corporate, and consumer levels. The North American Renewable Integration Study (NARIS) aims to inform grid planners, utilities, industry, policymakers, and other stakeholders about challenges and opportunities for continental system integration of large amounts of wind, solar, and hydropower to support a low-carbon future grid. The National Renewable Energy Laboratory (NREL) conducted a detailed, continent-wide analysis with planning scenarios of transmission, generation, and demand to reach 80%–92% carbon reductions (from 2005) for the Canadian electric power system, and up to 80% reductions continent-wide. We used a suite of models to study future scenarios and gain insights, including potential impacts on costs, emissions, resource adequacy, and the specific technologies that help enable the transition to a low-carbon grid. Our analysis had a particular focus on the potential role of cooperation among the three North American countries and between regions within each country, and how transmission can support sharing of supply and demand diversity. The NARIS project began in 2016. This report describes a U.S. perspective in coordination with the U.S. Department of Energy, and a companion report describes a Canadian perspective in coordination with the Natural Resources Canada. NARIS was an extension of a previous body of work, including the Western Wind and Solar Integration Study, the Eastern Renewable Generation Integration Study, Interconnections Seam Study, and the Pan Canadian Wind Integration Study. NARIS analyzed the entire continent in detail while studying higher renewable generation than previous studies. The scenarios in NARIS were informed by the goals in the Mid-Century Strategies for the Paris Agreement in each country.

14 SOLAR ENERGY↗

The North American Renewable Integration Study (NARIS): A Canadian Perspective

The North American electric power system is undergoing significant change, with renewable resources now contributing more generation than ever before. This transformation is poised to continue given decreasing technology costs and ambitious decarbonization goals at the federal, state, local, corporate, and consumer levels. The North American Renewable Integration Study (NARIS) aims to inform grid planners, utilities, industry, policymakers, and other stakeholders about challenges and opportunities for continental system integration of large amounts of wind, solar, and hydropower to support a low-carbon future grid. The National Renewable Energy Laboratory (NREL) conducted a detailed, continent-wide analysis with planning scenarios of transmission, generation, and demand to reach 80%–92% carbon reductions (from 2005) for the Canadian electric power system, and up to 80% reductions continent-wide. We used a suite of models to study future scenarios and gain insights, including potential impacts on costs, emissions, resource adequacy, and the specific technologies that help enable the transition to a low-carbon grid. Our analysis had a particular focus on the potential role of cooperation among the three North American countries and between regions within each country, and how transmission can support sharing of supply and demand diversity. The NARIS project began in 2016. This report describes a Canadian perspective in coordination with the Natural Resources Canada, and a companion report describes a U.S. perspective in coordination with the U.S. Department of Energy. NARIS was an extension of a previous body of work, including the Western Wind and Solar Integration Study, the Eastern Renewable Generation Integration Study, Interconnections Seam Study, and the Pan Canadian Wind Integration Study. NARIS analyzed the entire continent in detail while studying higher renewable generation than previous studies. The scenarios in NARIS were informed by the goals in the Mid-Century Strategies for the Paris Agreement in each country.

14 SOLAR ENERGY↗

Integrated thin film cadmium sulfide solar cell module

The design, development, fabrication and tests of flexible integrated thin-film cadmium sulfide solar cells and modules are discussed. The development of low cost and high production rate methods for interconnecting cells into large solar arrays is described. Chromium thin films were applied extensively in the deposited cell structures as a means to: (1) achieve high adherence between the cadmium sulfide films and the vacuum-metallized copper substrates, (2) obtain an ohmic contact to the cadmium sulfide films, and (3) improve the adherence of gold films as grids or contact areas.

Mickelsen, R. A.↗

Valuing Maintenance Strategies for Fusion Plants as Part of a Future Electricity Grid

Scheduled maintenance is likely to be lengthy and therefore consequential for the economics of fusion power plants. The maintenance strategy that maximizes the economic value of a plant depends on internal factors such as the cost and durability of the replaceable components, the frequency and duration of the maintenance blocks, and the external factors of the electricity system in which the plant operates. Here, this paper examines the value of fusion power plants with various maintenance properties in a decarbonized United States Eastern Interconnection circa 2050. Seasonal variations in electricity supply and demand mean that certain times of year, particularly spring to early summer, are best for scheduled maintenance. Seasonality has two important consequences. First, the value of a plant can be 15% higher than what one would naively expect if value were directly proportional to its availability. Second, in some cases, replacing fractions of a component in shorter maintenance blocks spread over multiple years is better than replacing it all at once during a longer outage, even through the overall availability of the plant is lower in the former scenario.

power plant, maintenance, seasonality, electricity↗

Learning-Based Load Control to Support Resilient Networked Microgrid Operations

Microgrids have proven to be an effective option for increasing the resiliency of critical end-use loads during extreme events. Building on past operational experiences, some microgrid operators are examining the potential to network microgrids to further improve resiliency. However, the frequency deviations experienced on isolated microgrids during transient events, such as switching operations, step increases in load, and loss of generation, are significantly larger than those typically seen on bulk transmission systems. The larger frequency deviations can cause a loss of inverter-connected assets, resulting in a loss of power to critical end-use loads. This paper presents a method of mitigating the impact of transient events by engaging end-use loads using Grid-Friendly Appliance TM (GFA) controllers. An online, i.e., real-time, device-level algorithm is presented, which adjusts individual GFA controller frequency set-points based on the operational characteristics of each end-use load, and on the changing grid dynamic characteristics. The presented method improves the dynamic stability of the networked microgrid operations while minimizing the interruptions to end-use loads. The presented work is validated with dynamic simulations using a modified version of the IEEE 123-node test system with three microgrids, using the GridLAB-D TM simulation environment.

Radhakrishnan, Nikitha↗

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Efficiency Modular SiC-based Power-Converter for Flexible-CHP Systems with Stability-Enhanced Grid-Support Functions

This project seeks to develop a modular, scalable MV power converter featuring stability-enhanced grid-support functions for future grid-interface applications in flexible combined heat and power (F-CHP) cogeneration plants, being fully compliant with the IEEE Standard 1547, category B—for operation in local areas with high aggregated distributed energy resource (DER) penetration, and also with the IEEE standard for the specification of microgrid controllers, namely IEEE Std 2030.7, with the goal to enable F-CHP systems for both microgrid and standalone applications. Further, the proposed converter will use a modular circuit topology, the MMC, which is scalable both in voltage and current by interconnecting power-cell building blocks, thus flexibly suiting the needs of F-CHP systems in the 1–20 MWe range. Furthermore, the use of 10 kV SiC MOSFET devices will minimize the number of power-cells needed to operate in 2–13.8 kV MV distribution systems, but more importantly, they will render feasible a power conversion efficiency > 98 %, and a power density > 10 kW/l. This is highly relevant given that these are two key performance metrics that will further increase the value of F-CHP systems by shortening the time required to recover their investment costs.

14 SOLAR ENERGY↗

FREQUENCY REGULATION WITH CONNECTED LIGHTING SYSTEMS

The management of end-use energy resources, e.g., commercial buildings, has been investigated as a promising source of services for the electric power grid. Lighting consumes about 17% electricity of U.S. commercial buildings; however, it may contribute significantly to services that improve the reliability and resilience of the grid due to its rapid speed of response. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change their power demand more quickly than most other building electricity end uses. But the potential of CLS to provide grid services has not been considerably investigated. In this paper, we describe initial research to evaluate the potential of CLS for the grid service of frequency regulation. Frequency regulation is a reliability product that corrects in a matter of seconds for short-term changes in the balance between supply and demand in the balancing area that might affect the stability of the power system. Frequency regulation signals for a medium office building are generated from the normalized test signals for the PJM Interconnection Reg-A and Reg-D regulations services. Control of the CLS locally to follow the Reg-A or Reg-D signal is used to provide contributions to the corresponding frequency regulation service. The performance of CLS for frequency regulation is evaluated using the PJM 40-Minute Performance Score Template. The performance scores obtained for all CLS categories for both Reg-A and Reg-D signals far exceed the minimum score for the qualification, a very promising result for CLS to provide frequency regulation service.

Wang, Peng↗