Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Astrometeric Science with SIM PlanetQuest

This viewgraph presentation reviews Astrometry with the Space Interferometry Mission (SIM) PlanetQuest. The topics include: 1) SIM PlanetQuest - the World's First Long- Baseline Optical Interferometer in Space; 2) National Academy of Sciences / NRC endorses SIM PlanetQuest; 3) SIM Planet Search; 4) Planetary System Architectures & Diversity; 5) SIM Search for 1~10 M(sub Earth) Planets Around Nearby Stars; 6) Deep Search of 120 nearby stars; 7) Planets around Young Stars; 8) SIM PlanetQuest Science Team; 9) Dark Halo of our Galaxy; 10) Dynamics of Galaxy Groups within 5 Mpc; 11) Probing Active Galactic Nuclei with Astrometry; 12) Snapshot Observing Mode: Astrometry for the masses; 13) SIM Technology Development is Complete; and 14) SIM Hardware, Tested for Flight.

space interferometry mission (SIM)↗

The CHARA optical array

The Center for High Angular Resolution Astronomy (CHARA) was established in the College of Arts and Sciences at Georgia State University in 1984 with the goals of designing, constructing, and then operating a facility for very high spatial resolution astronomy. The interest in such a facility grew out of the participants' decade of activity in speckle interferometry. Although speckle interferometry continues to provide important astrophysical measurements of a variety of objects, many pressing problems require resolution far beyond that which can be expected from single aperture telescopes. In early 1986, CHARA received a grant from the National Science Foundation which has permitted a detailed exploration of the feasibility of constructing a facility which will provide a hundred-fold increase in angular resolution over what is possible by speckle interferometry at the largest existing telescopes. The design concept for the CHARA Array was developed initially with the contractural collaboration of United Technologies Optical Systems, Inc., in West Palm Beach, Florida, an arrangement that expired in August 1987. In late November 1987, the Georgia Tech Research Institute joined with CHARA to continue and complete the design concept study. Very high-resolution imaging at optical wavelengths is clearly coming of age in astronomy. The CHARA Array and other related projects will be important and necessary milestones along the way toward the development of a major national facility for high-resolution imaging--a true optical counterpart to the Very Large Array. Ground-based arrays and their scientific output will lead to high resolution facilities in space and, ultimately, on the Moon.

Mcalister, Harold A.↗

Two-photon interferometry for high-resolution imaging

We discuss advantages of using non-classical states of light for two aspects of optical imaging: creating of miniature images on photosensitive substrates, which constitutes the foundation for optical lithography, and conversely, imaging of micro objects. In both cases, the classical resolution limit given by the Rayleigh criterion is approximately a half of the optical wavelength. It has been shown, however, that by using multi-photon quantum states of the light field, and multi-photon sensitive material or detector, this limit can be surpassed. In the present work, we give a rigorous quantum mechanical treatment of this problem, address some particularly widespread misconceptions and discuss the requirements arising on the way of turning the research on quantum imaging into a practical technology.

quantum technology↗

Precision Astrometry with SIM PlanetQuest: Science and Mission Update

This viewgraph presentation gives a science and mission update of precision Astrometry with the Space Interferometry Mission (SIM) PlanetQuest. The topics include: 1) SIM PlanetQuest - the World s First Long- Baseline Optical Interferometer in Space; 2) National Academy of Sciences / NRC endorses SIM PlanetQuest; 3) Astrometry with an Interferometer; 4) Overall Configuration (deployed); 5) SIM Planet Finding Capabilities; 6) Planet detection with SIM - minimum masses; 7) Searching for Terrestrial Planets with SIM; 8) Planets around Young Stars; 9) SIM PlanetQuest Science Team; 10) SIM Astrophysics; 11) SIM's Reach Extends Across our Entire Galaxy to do Precision Astrophysics; 12) Dynamics of Galaxy Groups within 5 Mpc; 13) Galactic tidal tails; 14) Dark Halo of our Galaxy; 15) Probing Active Galactic Nuclei with Astrometry; 16) Sample tile for relative astrometry; 17) Astrometric signatures of AGN; 18) Snapshot Observing Mode: Astrometry for the masses; and 19) SIM Technology Development is Complete.

space interferometry mission (SIM)↗

Phase Shift Interferometer and Growth Set Up to Step Pattern Formation During Growth From Solutions. Influence of the Oscillatory solution Flow on Stability

We have assembled an experimental setup based on Michelson interferometry with the growing crystal surface as one of the reflective surfaces. The crystallization part of the device allows optical monitoring of a face of a crystal growing at temperature stable within 0.05 C in a flow of solution of controlled direction and speed. The reference arm of the interferometer contains a liquid crystal element that allows controlled shifts of the phase of the interferograms. We employ an image-processing algorithm, which combines five images with a pi/2 phase difference between each pair of images. The images are transferred to a computer by a camera capable of capturing 60 frames per second. The device allows data collection on surface morphology and kinetics during the face layers growth over a relatively large area (approximately 4 sq. mm) in situ and in real time during growth. The estimated depth resolution of the phase shifting interferometry is approximately 50 Angstroms. The data will be analyzed in order to reveal and monitor step bunching during the growth process. The crystal chosen as a model for study in this work is KH2PO4 (KDP). This optically non-linear material is widely used in frequency doubling applications. There have been a number of studies of the kinetics of KDP crystallization that can serve as a benchmark for our investigations. However, so far, systematic quantitative characteristics of step interaction and bunching are missing. We intend to present our first quantitative results on the onset, initial stages and development of instabilities in moving step trains on vicinal crystal surfaces at varying supersaturation, flow rate, and flow direction. Behavior of a vicinal face growing from solution flowing normal to the steps and periodically changing its direction in time was considered theoretically. It was found that this oscillating flow reduces both stabilization and destabilization effects resulted from the unidirectional solution flow directed up the step stream and down the step stream. This reduction of stabilization and destabilization comes from effective mixing which entangles the phase shifts between the spatially periodic interface perturbation and the concentration wave induced by this perturbation. Numerical results and simplified mixing criterion will be discussed.

Chernov, Alex A.↗

Rapidly tunable ultrabroadband flying focus using adaptive optics and an axiparabola

A programmable ultrabroadband flying focus was produced using adaptive optics and an axiparabola with a continuous wave superluminescent diode. A deformable mirror and spatial light modulator were used to add a programmable amount of radial group delay, and an axiparabola was used to create an extended focus by imparting spherical aberration. Three different flying focus trajectories were measured using spectral interferometry, two with uniform velocity and one with an accelerating velocity. Here, the temporal response function width of the flying focus optics alone was calculated to be 52 ± 6 fs, and the focal spot size was measured to be (1.2 ± 0.1) × larger than the diffraction-limited spot size through the extended focus.

Markland, H. S. [University of Rochester, NY (Unit↗

Fabrication and testing of scatter plates for interferometry

Scatter plate interferometry has become a reliable method of measuring surface configurations of telescope mirrors and other optical components. The scatter plate used in an instrument should be of optimum quality if the surface it is being used to measure is to be of high accuracy. Tests were performed and results show that, although many scatter plates would function, few were of the optimum quality necessary. These few were of the 180 grit group, using 35- and 30-s exposures, which are figures derived from calculations.

Pour, J. J., Sr.↗

Navigation of the Galileo mission

An overview of the navigation of the Galileo mission is given. Predicted navigation performance for the various mission phases is discussed with particular emphasis given to the tour phase. Orbit determination strategies and resulting accuracies are discussed for various data types. In particular, the results of combining a new Very Long Baseline Interferometry (VLBI) data type called Differential One-Way Range (DOR) with conventional radio and optical data types are presented. Maneuver strategy results include the effects of maneuver placement and various targeting methods on propellant consumption and delivery accuracy. Emphasis is placed on new results obtained using asymptote and split targeting.

Miller, L. J.↗

High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

Ponseggi, B. G.↗

ARISE: A Challenging 25-m Space Antenna Design

ARISE (Advanced Radio Interferometry between Space and Earth). Future scientific and communications missions are conceptualizing using very large reflector antennas in space. The antenna dimensions are targeted from lOm to 25m beyond. Frequencies coveting L-band through W-band are being considered. these challenging missions, one may refer to ARISE (Advanced Radio Interferometry between Space and Earth), which is projected to utilize a 25-m dual Gregorian optics operating from 8 GHz to 86 Gl-lz . An artist's renditions Gregorian antenna concept is shown . The objective of this mission is to create a space-based VLBI system (integrated with ground based antennas) for high resolution mapping of black holes. Successful realization of ARISE necessitates development of several technologies . The most crucial technology is that of the deployable 25-m reflector that must work at frequencies as high as 43 and 86 GHz. The current baseline selection for ARISE is an inflatable antenna, under development for several other applications in communications and remote sensing.

Rahmat-Samii, Yahya↗

Optical Calibration Process Developed for Neural-Network-Based Optical Nondestructive Evaluation Method

A completely optical calibration process has been developed at Glenn for calibrating a neural-network-based nondestructive evaluation (NDE) method. The NDE method itself detects very small changes in the characteristic patterns or vibration mode shapes of vibrating structures as discussed in many references. The mode shapes or characteristic patterns are recorded using television or electronic holography and change when a structure experiences, for example, cracking, debonds, or variations in fastener properties. An artificial neural network can be trained to be very sensitive to changes in the mode shapes, but quantifying or calibrating that sensitivity in a consistent, meaningful, and deliverable manner has been challenging. The standard calibration approach has been difficult to implement, where the response to damage of the trained neural network is compared with the responses of vibration-measurement sensors. In particular, the vibration-measurement sensors are intrusive, insufficiently sensitive, and not numerous enough. In response to these difficulties, a completely optical alternative to the standard calibration approach was proposed and tested successfully. Specifically, the vibration mode to be monitored for structural damage was intentionally contaminated with known amounts of another mode, and the response of the trained neural network was measured as a function of the peak-to-peak amplitude of the contaminating mode. The neural network calibration technique essentially uses the vibration mode shapes of the undamaged structure as standards against which the changed mode shapes are compared. The published response of the network can be made nearly independent of the contaminating mode, if enough vibration modes are used to train the net. The sensitivity of the neural network can be adjusted for the environment in which the test is to be conducted. The response of a neural network trained with measured vibration patterns for use on a vibration isolation table in the presence of various sources of laboratory noise is shown. The output of the neural network is called the degradable classification index. The curve was generated by a simultaneous comparison of means, and it shows a peak-to-peak sensitivity of about 100 nm. The following graph uses model generated data from a compressor blade to show that much higher sensitivities are possible when the environment can be controlled better. The peak-to-peak sensitivity here is about 20 nm. The training procedure was modified for the second graph, and the data were subjected to an intensity-dependent transformation called folding. All the measurements for this approach to calibration were optical. The peak-to-peak amplitudes of the vibration modes were measured using heterodyne interferometry, and the modes themselves were recorded using television (electronic) holography.

Decker, Arthur J.↗

NASA astrophysics - Optical systems to explore the universe

Major and minor NASA astrophysical research efforts in the near-term are outlined, together with projections of direction for future projects. The Space Telescope is being readied for a 1986 launch and will feature an f/24, 2.4 m aperture, an MgF2 mirror with better than 1/60 wavelength accuracy and will be diffraction-limited in the UV. Pointing accuracy is designed to be 0.007 arcsec for 24 hr. Optical, spectrometric, and photometric equipment will be included. Around 1990, Shuttle-based missions will include an IR telescope and a subarcsec solar surface imaging device. A free-flying X-ray observatory (AXAF) is planned and will include a sensitivity that exceeds that of the HEAO-2 spacecraft by two orders of magnitude. Instruments are under development for higher resolution UV, gamma-ray, and IR studies. In-orbit interferometry is being studied and will depend on in-orbit assembly and servicing of stable structures with segmented optics.

Pellerin, C. J., Jr.↗

Performance Testing of TRL4-6 LISA Laser System

The Laser Interferometer Space Antenna (LISA) is an ESA-led future mission to measure gravitational waves from astronomical sources in space. LISA has been adopted as a formal mission by ESA in January 2024, and is expected to become a formal project at NASA within 2024. The laser system (LS), which includes four laser heads (LH) each containing a laser optical module (LOM) and laser electronics module (LEM), a frequency reference system (FRS, optical frequency reference) and four power monitor detectors (PMON), is one of the three U.S. contributions to LISA from NASA. The Lasers and Electro-Optics Branch at NASA GSFC has been developing and managing the design of the LISA LS. Currently, the TRL (technology readiness level) of the NASA LISA laser system is transitioning from 4 to 6. TRL 4/5 LISA LOM was sent to ESA in early 2023 and has undergone optical performance testing. [1] By late summer of 2024, NASA plans to deliver the TRL 6 LOM to ESA for performance evaluation. Since the delivery of the TRL4/5 LOM to ESA, we have taken steps to advance the TRL of the overall LS and have also started end-to-end system level testing involving other subsystems. They include 1) optical performance test of TRL6 LOM and TRL 5 LEM under thermal cycling, 2) end-to-end test of the laser head (LH) and the GSE (ground support equipment) FRS, driven by TRL 4 FRS electronics (FRS-E) provided by Ball Aerospace, 3) end-to-end test of the laser head (LH) with the GSE phase meter system (PMS) provided by Albert Einstein Institute, and 4) optical performance test of the LH with the PMON subsystem developed by NASA. The FRS, PMS, and PMON provide necessary frequency stability, relative phase stability between lasers, and output power stability, respectively. Since they are all vital for the sensitive laser interferometry performed in LISA, it is necessary to perform these system level testing by combining the LH and other subsystems, and to prove the optical performance at an early stage during the LS development. Our recent work has successfully demonstrated the intra-connectivity of the LS, as well as critical external interface with the PMS to meet the LISA’s performance requirements. In this talk, we will report on the latest status of the LH testing and system level test. We will also discuss the paths to bring each subsystem to TRL6+ and plans for future system level testing.

LISA↗

Read-only optical storage medium

Photosensitive recording medium consists of thin-film silicone resin deposited on photoconductive substrate. Medium is useful for holographic interferometry studies.

Gange, R. A.↗

A Photonic Clockwork for Deployed Timing and Radar

We present an environmentally robust photonic RF/microwave clockwork with low size, weight, and power (SWaP) for next-generation, field-deployable timing and radar applications. Compared to microwave references, optical local oscillators offer superior fractional frequency stability and phase-noise performance. When transferred with high fidelity into the RF/microwave domain, this “optical advantage” promises unparalleled performance across both private-industry and government (e.g., defense and space-agency) applications including very-long-baseline interferometry (VLBI), alternative positioning, navigation, and timing (PNT), multi-static synthetic aperture radar (MSAR), and geodetic sensing. However, this potential has yet to be fully realized outside the metrology lab primarily due to the high-SWaP and excessive environmental susceptibility of both the optical reference itself as well as the optical frequency comb (OFC) required to transfer the optical stability into the RF/microwave domain. Here, we present two demonstrations of a low-SWaP, environmentally robust photonic clockwork used to make a high-fidelity optical-microwave link with the stability and phase-noise performance relevant to the applications described above. Additionally, operational-testing results of the OFC subsystem under application-relevant environmental conditions will be presented to show pathway to field deployment of this critical subsystem.

Guangning Yang↗

Determination of an Infrared Reference Frame

The mission of the European Space Agency's Hipparcos satellite was to provide high precision astrometric and photometric data for over 100,000 stars and somewhat lower precision data on over a million additional stars. These observations were made in the optical band (340 - 850 nm) and resulted in median precisions of better than 1 milli-arcsec (mas) in position and parallax and I mas/yr in proper motion. The Hipparcos frame is inertial within an estimated uncertainty of +/- 0.25 mas/yr. The other important wavelength band for astrometry has been the radio band. A reference frame has been defined based on absolute Very Long Baseline Interferometry (VLBI) positions of several hundreds of radio sources. There have been a number of projects to refine the link between the optical and radio reference frames. In recent years there has been increasing interest in the astrometry of infrared sources. For example, stars with circumstellar shells can be observed in both the optical and radio (e.g. SiO maser emission). The infrared emission from such sources is dominated by thermal dust emission. The spatial distribution of radiation in the three bands is expected to be quite different. In 1982 we proposed a number of infrared-selected sources (S(sub 10 micron) greater than or approx. equal to 100 J(sub y)) for inclusion in the Hipparcos Input Catalog. Most of those sources were observed, and in Sutton (1997) we report the optical astrometric results (position, proper motion, and parallax) for 87 such sources. These sources were selected to have reasonable agreement between infrared and optical positions, and so may be used as primary standards for future infrared astrometry. They are well distributed across the sky, but exhibit some bias towards the galactic plane and the northern hemisphere. We have also obtained a set of 1480 secondary standards (unpublished) A comparison between optical positions and 86 GHz SiO maser positions for 10 sources indicates coincidence at the 0.15 arcsec level, consistent with current uncertainties in the SiO positions. Improved measurements of the SiO maser positions are needed. VLBI data show that SiO maser spots can be distributed in broken rings of radii 10 - 30 mas, presumably centered on the stellar position. However the SiO flux may be distributed asymmetrically, in which case the flux-weighted center of the SiO emission can be different from the stellar position. We have also published a related paper on phase fluctuations in millimeter interferometry (Sutton and Hueckstaedt 1996). Radiometric monitoring of emission from atmospheric water vapor may be a method for correcting for such fluctuations. This is relevant to positional determinations at centimeter and millimeter wavelengths. The integration of visible, infrared, and radio astrometry is one of our principal goals.

Sutton, Edmund C.↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗