Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An integral quality monitoring system for real-time verification of intensity modulated radiation therapy

Purpose: To develop an independent and on-line beam monitoring system, which can validate the accuracy of segment-by-segment energy fluence delivery for each treatment field. The system is also intended to be utilized for pretreatment dosimetric quality assurance of intensity modulated radiation therapy (IMRT), on-line image-guided adaptive radiation therapy, and volumetric modulated arc therapy. Methods: The system, referred to as the integral quality monitor (IQM), utilizes an area integrating energy fluence monitoring sensor (AIMS) positioned between the final beam shaping device [i.e., multileaf collimator (MLC)] and the patient. The prototype AIMS consists of a novel spatially sensitive large area ionization chamber with a gradient along the direction of the MLC motion. The signal from the AIMS provides a simple output for each beam segment, which is compared in real time to the expected value. The prototype ionization chamber, with a physical area of 22x22 cm{sup 2}, has been constructed out of aluminum with the electrode separations varying linearly from 2 to 20 mm. A calculation method has been developed to predict AIMS signals based on an elementwise integration technique, which takes into account various predetermined factors, including the spatial response function of the chamber, MLC characteristics, beam transmission through the secondary jaws, and field size factors. The influence of the ionization chamber on the beam has been evaluated in terms of transmission, surface dose, beam profiles, and depth dose. The sensitivity of the system was tested by introducing small deviations in leaf positions. A small set of IMRT fields for prostate and head and neck plans was used to evaluate the system. The ionization chamber and the data acquisition software systems were interfaced to two different types of linear accelerators: Elekta Synergy and Varian iX. Results: For a 10x10 cm{sup 2} field, the chamber attenuates the beam intensity by 7% and 5% for 6 and 18 MV beams, respectively, without significantly changing the depth dose, surface dose, and dose profile characteristics. An MLC bank calibration error of 1 mm causes the IQM signal of a 3x3 cm{sup 2} aperture to change by 3%. A positioning error in a single 5 mm wide leaf by 3 mm in 3x3 cm{sup 2} aperture causes a signal difference of 2%. Initial results for prostate and head and neck IMRT fields show an average agreement between calculation and measurement to within 1%, with a maximum deviation for each of the smallest beam segments to within 5%. When the beam segments of a prostate IMRT field were shifted by 3 mm from their original position, along the direction of the MLC motion, the IQM signals varied, on average, by 2.5%. Conclusions: The prototype IQM system can validate the accuracy of beam delivery in real time by comparing precalculated and measured AIMS signals. The system is capable of capturing errors in MLC leaf calibration or malfunctions in the positioning of an individual leaf. The AIMS does not significantly alter the beam quality and therefore could be implemented without requiring recommissioning measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Simbol-X Low Energy Detector

For the Low Energy Detector of Simbol-X a new type of active pixel sensor based on the integrated amplifier DEPFET has been developed. This concept combines large area, scalable pixel size, low noise, and ultra-fast readout. Flight representative prototypes have been processed with a performance matching the Simbol-X specifications and demonstrating the technology readiness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Traceable nanoscale measurement at NML-SIRIM

The role of national metrology institute (NMI) has always been very crucial in national technology development. One of the key activities of the NMI is to provide traceable measurement in all parameters under the International System of Units (SI). Dimensional measurement where size and shape are two important features investigated, is one of the important area covered by NMIs. To support the national technology development, particularly in manufacturing sectors and emerging technology such nanotechnology, the National Metrology Laboratory, SIRIM Berhad (NML-SIRIM), has embarked on a project to equip Malaysia with state-of-the-art nanoscale measurement facility with the aims of providing traceability of measurement at nanoscale. This paper will look into some of the results from current activities at NML-SIRIM related to measurement at nanoscale particularly on application of atomic force microscope (AFM) and laser based sensor in dimensional measurement. Step height standards of different sizes were measured using AFM and laser-based sensors. These probes are integrated into a long-range nanoscale measuring machine traceable to the international definition of the meter thus ensuring their traceability. Consistency of results obtained by these two methods will be discussed and presented. Factors affecting their measurements as well as their related uncertainty of measurements will also be presented.

47 OTHER INSTRUMENTATION↗

Identifications and classifications of human locomotion using Rayleigh-enhanced distributed fiber acoustic sensors with deep neural networks

Abstract This paper reports on the use of machine learning to delineate data harnessed by fiber-optic distributed acoustic sensors (DAS) using fiber with enhanced Rayleigh backscattering to recognize vibration events induced by human locomotion. The DAS used in this work is based on homodyne phase-sensitive optical time-domain reflectometry (φ-OTDR). The signal-to-noise ratio (SNR) of the DAS was enhanced using femtosecond laser-induced artificial Rayleigh scattering centers in single-mode fiber cores. Both supervised and unsupervised machine-learning algorithms were explored to identify people and specific events that produce acoustic signals. Using convolutional deep neural networks, the supervised machine learning scheme achieved over 76.25% accuracy in recognizing human identities. Conversely, the unsupervised machine learning scheme achieved over 77.65% accuracy in recognizing events and human identities through acoustic signals. Through integrated efforts on both sensor device innovation and machine learning data analytics, this paper shows that the DAS technique can be an effective security technology to detect and to identify highly similar acoustic events with high spatial resolution and high accuracies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent developments in guided wave travel time tomography

The concept of predictive maintenance using permanent sensors that monitor the integrity of an installation is an interesting addition to the current method of periodic inspections. Guided wave tomography had been developed to create a map of the wall thickness using the travel times of guided waves. It can be used for both monitoring and for inspection of pipe-segments that are difficult to access, for instance at the location of pipe-supports. An important outcome of the tomography is the minimum remaining wall thickness, as this is critical in the scheduling of a replacement of the pipe-segment. In order to improve the sizing accuracy we have improved the tomography scheme. A number of major improvements have been realized allowing to extend the application envelope to pipes with a larger wall thickness and to larger distances between the transducer rings. Simulation results indicate that the sizing accuracy has improved and that is now possible to have a spacing of 8 meter between the source-ring and the receiver-ring. Additionally a reduction of the number of sensors required might be possible as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

External-field-free magnetic biosensor

In this paper, we report a magnetic nanoparticle (MNP) detection scheme without the presence of any external magnetic field. The proposed magnetic sensor uses a patterned groove structure within the sensor so that no external magnetic field is needed to magnetize the MNPs. An example is given based on a giant magnetoresistance (GMR) sensing device with a spin valve structure. For this structure, the detection of MNPs located inside the groove and near the free layer is demonstrated under no external magnetic field. Micromagnetic simulations are performed to calculate the signal to noise level of this detection scheme. A maximum signal to noise ratio (SNR) of 18.6 dB from one iron oxide magnetic nanoparticle with 8 nm radius is achieved. As proof of concept, this external-field-free GMR sensor with groove structure of 200 nm × 200 nm is fabricated using a photo and an electron beam integrated lithography process. Using this sensor, the feasibility demonstration of the detection SNR of 9.3 dB is achieved for 30 μl magnetic nanoparticles suspension (30 nm iron oxide particles, 1 mg/ml). This proposed external-field-free sensor structure is not limited to GMR devices and could be applicable to other magnetic biosensing devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wireless Sensor Network for Improving the Energy Efficiency of Data Centers

Data centers occupy less than 2% of the federally owned portfolio under the jurisdiction, custody or control of the U.S. General Services Administration (GSA), but represent nearly 5% of the agency’s overall energy budget. Assuming that energy use in GSA’s data centers tracks with industry averages, GSA can anticipate that data center energy use will grow at an annual rate of 15%, a doubling of energy use every five years.1 In fact, energy is the single largest operating expense for most data centers. Improving the energy performance of data center systems supports progress toward meeting federally mandated greenhouse gas emission-­reduction goals, while reducing operating and energy costs and allowing for greater flexibility in future expansion by eliminating the need to provide additional power and cooling. Studies sponsored by the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA) have shown that energy use can be reduced by 25% through implementation of best practices and commercially available technologies. The present study evaluated the effectiveness of a strategy to cost- effectively improve the efficiency of data center cooling, which is the single largest non-­IT load. The technology that was evaluated consists of a network of wireless sensors—including branch circuit power monitors, temperature sensors, humidity sensors, and pressure sensors, along with an integrated software product to help analyze the collected data. The technology itself does not save energy; however, its information collection and analysis features enable users to understand operating conditions and identify problem areas. In addition, data obtained by this technology can be input into assessment tools that can identify additional best practice measures. Energy savings result from the implementation of the best practices. The study was conducted to validate the premise that providing data center operators with detailed, real- time measurement of environmental parameters and power consumption enables them to establish baseline performance, discover areas of sub-optimal performance, and identify concrete opportunities for improvement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Design Parameter Optimization to Improve the Sensitivity of a Bimorph Polysilicon-Based MEMS Sensor for Helium Detection

Helium is integral in several industries, including nuclear waste management and semiconductors. Thus, developing a sensing method for detecting helium is essential to ensure the proper operation of such facilities. Several approaches can be used for helium detection, including based on the high thermal conductivity of helium, which is several times higher than air. This work utilizes the high thermal conductivity of helium to design and analyze a bimorph MEMS sensor for helium sensing applications. COMSOL Multiphysics software (version 6.2) is used to carry out this investigation. The sensor is constructed from poly-silicon and SiO 2 materials with a trenched cantilever beam configuration. The sensor is electrically heated, and its morphed displacement depends on the surrounding gas’s composition, which decreases in the presence of helium. Several factors were investigated to probe their effect on the sensor’s sensitivity to helium, including the thickness of the poly-silicon layer, the configuration of the trench, and the thickness and location of SiO 2 layer. The simulations showed that the best performance, up to 2 ppm helium detection level, can be achieved with thinner beams and medium trench lengths.

47 OTHER INSTRUMENTATION↗

GUC CSU X-Band Precipitation Extracted Radar Columns and In-Situ Sensors (RadCLss)

For the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign, a scanning X-Band dual-polarimetric radar provided by Colorado State University (CSU) was deployed to estimate precipitation within the Upper Colorado River Basin. In order to evaluate precipitation estimates from the CSU X-Band Radar (XPRECIPRADAR), radar columns are extracted above field sites of interest to the SAIL campaign. These radar columns are then matched to in-situ sensors at these locations.

54 ENVIRONMENTAL SCIENCES↗

Engineering Scale Testing of Robotic Inspection Tools for Double Shell Tanks at Hanford - 18349

Waste found in the annulus of the AY-102 double-shell tank (DST) at Hanford has prompted the need for the development of inspection tools that are able to access confined spaces around and underneath the tanks. During the last year, Florida International University (FIU) has been developing inspection tools that are capable of accessing the tank floors through the air supply line, the air refractory channels and the drain lines. This effort has led to the development of a pneumatic pipe crawler and a miniature rover. In this paper, updates to the inspection tool designs and the full scale testing of both systems are presented. The tools provide visual feedback for the operator, carrying with them onboard cameras and light sources. The images are streamed back live via a tether, which also provides power to the devices. To increase the sensing capabilities of both tools, temperature, humidity and radiation sensor modules are being integrated onto the developed systems, and can be interchanged depending on the inspection objectives. The miniature rover measures 7 cm in length and 3.8 cm in width, and travels upside down on the bottom of the tank to avoid debris accumulated in the channels. The video is also being processed real-time to provide control of the unit semi-autonomously. The pipe crawler measures approximately 76 cm in length and 6.4 cm in diameter, and travels using pneumatic actuators that emulate the peristaltic movement contractions typical of worm type robots. A full-scale sectional mock-up of the DST foundation, refractory system and annulus is currently being developed as a test-bed for the testing of the inspection tools. The intention of the test-bed is to demonstrate the viability of using both inspection tools in configurations similar to the actual tank. The test-bed includes a 2.43 m wide section of both tank liners, refractory channels and concrete foundation with drain slots. The test-bed is designed to be modular so that various plate thicknesses can be easily utilized and different refractory configurations can be incorporated. Currently, the refractory channels are of the tree type structure with turns that are approximately 30 degrees. Both inspection tools were demonstrated in the mock-up facility. The miniature rover ran successfully through the drain slots from the annulus to central plenum and had no issues making the 90-degree turns. The peristaltic crawler was able to navigate through the 7.62 cm air supply line from the annulus to the central plenum. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring

Wearable devices for health monitoring and fitness management have foreseen a rapidly expanding market, especially those for noninvasive and continuous measurements with real-time display that provide practical convenience and eliminated safety/infection risks. In this research, a self-powered and fully integrated smartwatch that consists of flexible photovoltaic cells and rechargeable batteries in the forms of a “watch strap”, electrochemical glucose sensors, customized circuits, and display units integrated into a “dial” platform is successfully fabricated for real-time and continuous monitoring of sweat glucose levels. The functionality of the smartwatch, including sweat glucose sensing, signal processing, and display, can be supported with the harvested/converted solar energy without external charging devices. The Zn-MnO 2 batteries serve as intermediate energy storage units and the utilization of aqueous electrolytes eliminated safety concerns for batteries, which is critical for wearable devices. Such a wearable system in a smartwatch fashion realizes integration of energy modules with self-powered capability, electrochemical sensors for noninvasive glucose monitoring, and in situ and real-time signal processing/display in a single platform for the first time. The as-fabricated fully integrated and self-powered smartwatch also provides a promising protocol for statistical study and clinical investigation to reveal correlations between sweat compositions and human body dynamics.

47 OTHER INSTRUMENTATION↗

Chemiresistors for the Real‐Time Wireless Detection of Anions

Abstract Reported is an electrical transduction platform for real‐time wireless anion sensing using single‐walled carbon nanotubes (SWCNTs) noncovalently functionalized with squaramide‐based anion binding selectors. Systematically studied are anion‐binding properties and efficiency of the electrical transduction of the functionalized SWCNT composites using the squaramide‐based selectors with two similar electron‐withdrawing groups, 3,5‐bis(trifluoromethyl)benzyl ( 1 ) and 3,5‐bis(trifluoromethyl)phenyl ( 2 ), which induce hydrogen‐bonding interaction with anions and deprotonation of a squaramide N–H proton upon addition of acetate (AcO − ), respectively. Charge transduction occurs with AcO − as a result of charge transfer from the deprotonated selector 2 , whereas less sensitive transduction is observed with selector 1 via hydrogen‐bonding interaction. These results provide guidelines to efficiently transduce the chemical interaction between selectors and anions to create resistive transduction with functionalized SWCNTs. Electron‐withdrawing groups adjacent to the squaramide as well as proximate cationic pyridyl groups, enhance the anion binding affinity and also lower the selector's p K a . The chemiresistive sensor arrays are readily integrated with a wireless sensing module and demonstrated real‐time sensing of multiple anions with a smartphone readout.

Choi, Seon‐Jin↗

Reinforced Electrode Architecture for a Flexible Battery with Paperlike Characteristics

Compliant energy storage has not kept pace with flexible electronics. Herein we demonstrate a technique to reinforce arbitrary battery electrodes by supporting them with mechanically tough, low-cost fibrous membranes, which also serve as the separator. The membranes were laminated to form a full cell, and this stacked membrane reinforcement bears the loads during flexing. This technique was used to make a high energy density, nontoxic Zn-MnO2 battery with printed current collectors. The Zn and MnO2 electrodes were prepared by using a solution-based embedding process. The cell had a nominal potential of 1.5 V and an effective capacity of approximately 3 mA h cm(-2). We investigated the effect of bending and fatigue on the electrochemical performance and mechanical integrity of the battery. The battery was able to maintain its capacity even after 1000 flex cycles to a bend radius of 2.54 cm. The battery showed an improvement in discharge capacity (ca. 10%) if the MnO2 electrode was flexed to tension as a result of the improvement of particle-to-particle contact. In a demonstration, the flexible battery was used to power a light-emitting diode display integrated with a strain sensor and microcontroller.

Gaikwad, AM↗

Diagnostic and Prognostic Tools for Residual Life Estimation in Aging Nuclear Power Plant Components

A central issue in life extension for the current fleet of light water nuclear power reactors (LWR) is the early detection and monitoring of significant materials degradation. To meet this need, nondestructive methods that are suitable for continuous monitoring over extended time periods (months to years) are needed. A related issue is the ability to estimate remaining useful life (RUL) of components and systems based on condition assessment or degradation information. Monitoring for early detection of materials degradation requires novel sensors and enhanced data integration techniques. A range of acoustic and electromagnetic measurement methods may be suitable, including acoustic microscopy, eddy current and magnetic Barkhausen emission. Prognostic methods that predict rate of degradation and remaining life based on phenomena that can be described by linear elastic fracture mechanics have been reported by several researchers. However, the challenge of predicting remaining life starting from earlier phases of degradation is largely unsolved. This paper discusses an assessment of selected diagnostic techniques, and the application of Bayesian prognostic algorithms to detection of early degradation and rate of degradation/life prediction. Such measurement and modeling methods are expected to form the basis for a new range of advanced diagnostic and prognostic approaches for assessing and monitoring life extension of ageing light water reactors.

diagnostics↗

Electric field step in air gap streamer discharges

Electric field (E-field) in air gap streamer discharges under positive lightning impulse was measured by specifically developed integrated electro-optic sensors. An E-field step phenomenon was observed. The E-field firstly agreed with the Laplace field, then suddenly increased with a rise time of {mu}s. The occurrence probability of this phenomenon increased as the applied voltage increased. The discharge current waveforms and photos taken by a fast camera prove the E-field step was caused by the space net charge. From the E-step rise time and the corona area range, the average electron drift speed under the experiment situation was estimated about 0.2 x 10{sup 6} - 0.6x 10{sup 6} m/s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗