Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIGH EXPLOSIVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

An updated technique to obtain explosive kinetics data on microsecond timescales

There are few techniques available for chemists to obtain time-to-explosion data with known temperature inputs at the early stages of the design and synthesis of new explosives. In the 1960s, a technique was developed to rapidly heat milligram-quantities of confined explosives to ~1000 K on microsecond timescales. Wenograd loaded explosives inside stainless steel hypodermic needles, connected them to a fireset and rapidly discharged a capacitor through the steel. He obtained the temperature by measuring the needle resistance in a Wheatstone bridge arrangement and the time to explosion from a needle rupture. However, owing to the narrow-gauge needles used in the original research, the experiment was only possible with melt-castable explosives; it was never replicated, and modern diagnostics are now available with advances beyond the 1960s. Here, we report the development of the High Explosives Initiation Time (HEIT) test, which utilizes a 250 J pulsed power system to heat the needles. This work extends the Wenograd approach by using optical diagnostics, computational modeling, and advanced techniques to measure needle resistance and needle rupture. Preliminary rate information for pentaerythritol tetranitrate (PETN) will be presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SURF Model Calibration Strategy

SURF and SURFplus are high explosive reactive burn models for shock initiation and propagation of detonation waves. They are engineering models motivated by the ignition & growth concept of high spots and for SURFplus a second slow reaction for the energy release from carbon clustering. A key feature of the SURF model is that there is a partial decoupling between model parameters and detonation properties. This enables reduced sets of independent parameters to be calibrated sequentially for the initiation and propagation regimes. Here we focus on a methodology for tting the initiation parameters to Pop plot data based on 1-D simulations to compute a numerical Pop plot. In addition, the strategy for tting the remaining parameters for the propagation regime and failure diameter is discussed.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Reinforced Ammo Can Validation Test Report for Lawrence Livermore National Laboratory

A research effort was conducted to investigate the effects of an unintentional internal detonation of energetic materials on a small transportation container called the “Reinforced Ammo Can” (RAC), which is currently approved for the transport of energetic materials up to 2 grams net explosive weight (NEW) onsite at Lawrence Livermore National Laboratory (LLNL). The project used experimental testing of the containers based on simulated results conducted by a Missouri S & T explosives engineering graduate student while on an internship working in explosives safety at LLNL. The proposed experimental testing consisted of 20 central detonation tests in separate Reinforced Ammo Can containers to verify their high explosive (HE) containment capability. RAC containers are required for transporting secondary explosives on site at LLNL Site 200 in quantities between 300 mg and 2 grams of Trinitrotoluene (TNT) equivalent NEW. Currently, the LLNL Environmental Safety and Health (ES&H) Manual states that the RAC containers are permissible for on-site transportation of secondary explosives up to 2 grams NEW by approved HE handlers with the approval of an Explosives Safety Expert (ESE). Simulated results indicated that tensile failure of the closure mechanism on the container is the most likely failure mode, and showed potential occurrence at the 2 gram NEW threshold. Experimental validation tests were conducted indicating failure/rupture of the containers lid with venting of the detonation products at the 2 gram NEW test threshold with an explosive mass safety factor of 1.3. Failure consisted of impact opening the container latch mechanism resulting in potential ejection of the lid depending on the orientation of the charge within the confinement. This analysis solely is an evaluation of the response of the containment if a detonation were to occur, it does NOT consider the probability of such an event.

42 ENGINEERING↗

Chemical, Biological, and Explosive Sensors for Field Measurements

Special Technologies Laboratory (STL) is developing handheld chemical, biological, and explosive (CBE) detection systems and sensor motes for wireless networked field operations. The CBE sensors are capable of detecting and identifying multiple targeted toxic industrial chemicals (TICs) and high-explosive vapor components. The CBE devices are based on differential mobility spectrometry (DMS) coupled with fast gas chromatography (GC) or mass spectrometry. The systems all include the concepts of: 1. Direct air/particulate “smart” sampling 2. Selective, continuous real-time (~1 sec) alert monitoring using DMS 3. Highly selective, rapid dual technology separation/verification analysis The biosensor technology is based on Raman aerosol particle flow cytometry for target detection and identification. Monitoring and identifying trace level chemical vapors directly from ambient air will allow First Responders to quickly adapt situational response strategies and personal protective equipment needs to the specific response scenario being encountered. First Responders require great confidence in the measurements and ability of a given system to detect CBE below threshold levels without interferences. The concept of determining the background matrix in near real-time to allow subsequent automated field-programmable method selection and cueing of high-value assets in a wide range of environs will be presented. This provides CBE information for decisions prior to First Responders entering the response site or sending a portable mobile unit for a remote site survey of the hazards. The focus is on real-time information needed by those responsible for emergency response and national security.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refractive Imaging of Air Shock Above Microscale Defects in Pentaerythritol Tetranitrate (PETN) Films

Physical vapor deposition (PVD) of high explosives can produce energetic samples with unique microstructure and morphology compared to traditional powder processing techniques, but challenges may exist in fabricating explosive films without defects. Deposition conditions and substrate material may promote microcracking and other defects in the explosive films. Here, we investigate effects of engineered microscale defects (gaps) on detonation propagation and failure for pentaerythritol tetranitrate (PETN) films using ultra-high-speed refractive imaging and hydrocode modelling. Observations of the air shock above the gap reveal significant instabilities during gap crossing and re-ignition.

36 MATERIALS SCIENCE↗

Real-time X-ray Diffraction Measurements of Shocked Polycrystalline Tin and Aluminum

A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35-ns pulse. The characteristic Kα lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic Kβ line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3-mm by 6-mm spot and 1° full-width-half-maximum (FWHM) angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5°. A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device (CCD) camera through a coherent fiberoptic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1-mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic (fcc) aluminum lattice with no phase transformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HERMES Model Modifications and Applications 2012

HERMES was developed to meet requirements for a model to describe explosive response to impacts that do not produce prompt detonation, but can include delayed detonations such as DDT and XDT. Such response is termed High Explosive Violent Response (HEVR). The HERMES model includes a constitutive description of strength as a function of pressure, strain-rate, strain, and ambient temperature; the development of damage including fragmentation and porosity; the conditions leading to ignition; the propagation of a burning reaction through the volume of damaged explosive; the burn-up of the damaged and undamaged explosive; and the development of detonation using the Computational Reaction Evolution dependent on Entropy (S) and Time (CREST) detonation model. CREST can distinguish gradual pressure increases from shock waves, and also predict the increase in shock sensitivity to detonation that results from increased porosity. This year HERMES has been implemented as a User Defined Function in ALE 3D. As a result, modifications to the model can be implemented in a timely fashion asynchronously from the ALE 3D distribution process. There are differences between the implementation of HERMES in ALE 3D and the implementation in LS DYNA. The major difference is the propagation of an ignition front from an element that has started to burn. In LS DYNA, the time at which an element begins to burn is based on the minimum line-of-sight distance between the element and any previously ignited element. In ALE 3D the time to burn is based on a level-set method that propagates the ignition front from all elements that were previously ignited. The ALE 3D implementation modifies the time of ignition when element deformation changes the distance from the element to the source. The LS DYNA implementation does not. There are also differences in the implementation of artificial viscosity, which is important for CREST since the artificial viscosity increases the element entropy in a shock. In general, however, the differences have proven minor. In collaboration with the Atomic Weapons Establishment, UK (AWE), we have characterized two additional explosives – PETN and Composition B, a mixture of 60% RDX and 40% TNT by weight. Applications of HERMES to these explosives are described below.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam Profile Measurements at the DARHT II Accelerator Exit

Measurements of the beam profile at the exit of the DARHT II accelerator have been made. The 1.65-kA, 17-MeV DARHT-II linear induction accelerator [1] is unique in that its beam pulse has a long, 1.6-ns flattop during which the kinetic energy varies by less than ±2%. Four short pulses are selected out of this long pulse in the downstream transport [2], and these are converted to bremsstrahlung for multi-pulse flash radiography of high explosive driven hydrodynamic experiments. The objective of the measurements was to demonstrate the capability to make these measurements with a long beam pulse of high intensity. Many observations can be made on the basis of these measurements. These are described herein.

43 PARTICLE ACCELERATORS↗

ESIAS Pseudocode

The Explosive Shock Image Analysis System (ESAIS) is designed to provide a semiautomated quantitative analysis of fast-frame imagery taken during the detonation of high explosive (HE) rate sticks. ESIAS does this by assisting the user in identifying the HE stick geometry on the image (i.e., sides of the undetonated HE stick, detonation front, an axial reference point to assist in the inter-comparison of images); scaling the images based on the known diameter of the undetonated HE stick; identifying the profiles of various surfaces resulting from the detonation process such as the shock wave and product gases or the outer pipe surface; calculating the detonation speed of the HE by tracking the distance it travels between two images with a known time lapse between the images; and determining the slit velocities resulting from the detonation. ESIAS will also import scope traces from oscilloscopes and assist in identifying the time of arrival of significant peaks.

97 MATHEMATICS AND COMPUTING↗

The L = 6.6 Oosik barium plasma injection experiment and magnetic storm of March 7, 1972

A high-explosive shaped charge vaporizing a hollow conical liner of Ba metal and producing a fast field-aligned jet of plasma was detonated at high altitude, during a quiescent phase of a magnetic storm initiated by an ssc 10 hrs prior to the experiment, in an attempt to trace out and observe the dynamics of an auroral field line in the magnetosphere. Observations offer evidence for an upward Birkeland current sheet at the poleward edge of the auroral spiral of 8 x 10 to the minus second power A/m. Unusual features of the substorm leave open the possibility that the plasma injection may have triggered it.

Wescott, E. M.↗

Molecular simulations of adsorption of RDX and TATP on IRMOF-1(Be)

The influence of different sorption sites of isoreticular metal-organic frameworks (IRMOFs) on interactions with explosive molecules is investigated. Different connector effects are taken into account by choosing IRMOF-1(Be) (IRMOF-1 with Zn replaced by Be), and two high explosive molecules: 1,3,5-trinitro-s-triazine (RDX) and triacetone triperoxide (TATP). The key interaction features (structural, electronic and energetic) of selected contaminants were analyzed by means of density functional calculations. The interaction of RDX and TATP with different IRMOF-1(Be) fragments is studied. The results show that physisorption is favored and occurs due to hydrogen bonding, which involves the C-H groups of both molecules and the carbonyl oxygen atoms of IRMOF-1(Be). Additional stabilization of RDX and TATP arises from weak electrostatic interactions. Interaction with IRMOF-1(Be) fragments leads to polarization of the target molecules. Of the molecular configurations we have studied, the Be-O-C cluster connected with six benzene linkers (1,4-benzenedicarboxylate, BDC), possesses the highest binding energy for the studied explosives (-16.4 kcal mol-1 for RDX and -12.9 kcal mol-1 for TATP). The main difference was discovered to be in the preferable adsorption site for adsorbates (RDX above the small and TATP placed above the big cage). Based on these results, IRMOF-1 can be suggested as an effective material for storage and also for separation of similar explosives. Hydration destabilizes most of the studied adsorption systems by 1-3 kcal mol-1 but it leads to the same trend in the binding strength as found for the non-hydrated complexes.

08 HYDROGEN↗

On the Search for Nuclear Resonance Fluorescence Signatures of 235U and 238U above 3 MeV

Nuclear resonance fluorescence is a physical process that provides an isotope-specific signature that could be used for the identification and characterization of materials. The technique involves the detection of prompt discrete-energy photons emitted from a sample that is exposed to MeV-energy photons. Potential applications of the technique range from detection of high explosives to characterization of special nuclear materials such as 235U. Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct a pair of measurements to search for a nuclear resonance fluorescence response of 235U above 3 MeV and of 238U above 5 MeV using an 8 g sample of highly enriched uranium and a 90 g sample of depleted uranium. No new signatures were observed. The minimum detectable integrated cross section for 235U is presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the Search for Nuclear Resonance Fluorescence Signatures of 235U and 238U above 3 MeV

Abstract–Nuclear resonance fluorescence is a physical process that provides an isotope-specific signature that could be used for the identification and characterization of materials. The technique involves the detection of prompt discrete-energy photons emitted from a sample that is exposed to photons in the MeV energy range. Potential applications of the technique range from detection of high explosives to characterization of special nuclear materials such as 235U. Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct a a pair of measurements to search for a nuclear resonance fluorescence response of 235U above 3 MeV and of 238U above 5 MeV using an 8 g sample of highly enriched uranium and a 90 g sample of depleted uranium. No new signatures were observed. The minimum detectable integrated cross section for 235U is presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Grain-Scale Simulations of Hot-Spot Initiation for Shocked TATB

High-explosive (HE) material consists of large-sized grains with micron-sized embedded impurities and pores. Under various mechanical/thermal insults, these pores collapse generating high-temperature regions leading to ignition. A computational study has been performed to investigate the mechanisms of pore collapse and hot spot initiation in TATB crystals, employing the thermohydrodynamics arbitrary-Lagrange-Eulerian code ALE3D. This initial study includes non-reactive dynamics to isolate the thermal and hydrodynamical effects. Two-dimensional high-resolution large-scale meso-scale simulations have been undertaken. We study an axisymmetric configuration for pore radii ranging from 0.5 to 2{micro}m, with initial shock pressures in the range from 3 to 11 GPa. A Mie-Gruneisen Equation of State (EOS) model is used for TATB, and includes a constant yield strength and shear modulus; while the air in the pore invokes a Livermore Equation of State (LEOS) model. The parameter space is systematically studied by considering various shock strengths, pore diameters and material properties. We find that thermal diffusion from the collapsed pores has an important effect in generating high-temperature hot spots in the TATB.

33 ADVANCED PROPULSION SYSTEMS↗

Comprehensive Data Analysis and Analytic Method Development for PBX9501 Material (FY2019 Annual Report of Aging and Lifetimes Program)

In the polymer bonded explosive (PBX) 9501, a binder consisting of 2.5 wt% nitroplasticizer (NP) and 2.5 wt% Estane R 5703 (Estane) is combined with 94.9 wt% of the high-explosive HMX and 0.1 wt% stabilizer. Because of its flexibility and tensile strength, this binder lowers the sensitivity and improves the manufacturability of PBX 9501. However, like many plasticizers comprised of low molecular weight components, NP has a tendency to diffuse out of the PBX 9501 matrix and can decompose at moderate temperatures into reactive byproducts, such as NO, NO 2 , H 2 O, and HNO x . Through oxidation and hydrolysis, these molecules can further degrade NP and Estane, ultimately degrading the properties of PBX 9501. While gaseous molecules can readily diffuse out of the PBX 9501 charges, the intermediates with lower volatility are more likely trapped in the condensed phase inside the charges and, in a closed system, will co-exist with Estane for an extended period of time creating an ongoing reactive environment. Understanding the rates of formation for these volatiles and intermediates during the NP degradation is therefore a critical prerequisite for understanding the long-term stability of polymeric binders used in munition systems. To work toward this ultimate goal, in the past year, we have conducted comprehensive studies on the physical properties of NP and finished three-year long aging experiment to understand the aging behavior of NP under thermal treatment. Important results are summarized in this annual report. Although NP is widely used in the DOE complex, their physical properties are rather scattered and inconsistent in the open literature. For example, there are at least two widely different values, 14.5°C and -15°C, for the melting point of NP. Although it is known that NP is a eutectic 50:50 mixture of BDNPA and BDNPF, their eutectic phase diagram is not well documented. Furthermore, the effect of temperature on the miscibility between water and eutectic BDNPA/F mixture is rarely reported. To fill these knowledge gaps, a large set of BDNPA/F mixtures with BDNPA concentration ranging from 0 to 100 wt% was analyzed using DSC techniques. In addition to determining the eutectic melt point as -25°C, a phase diagram of the BDNPA/F system was constructed from -30°C to 45°C. With this phase diagram, the phase transition temperatures and composition can be readily found for the BDNPA/F mixtures with various mass ratios.

36 MATERIALS SCIENCE↗

NMIS with Imaging and Gamma Ray Spectrometry for Pu, HEU, HE and Other Materials

The Nuclear Material Identification System (NMIS) has been under development at ORNL and the National Nuclear Security Administration (NNSA) Y-12 National Security Complex since 1984. In the mid-1990s, what is now the US Department of Energy (DOE) Office of Nuclear Verification (ONV) realized that it was a useful technology for future arms control treaty applications and supported further development of the system. In 2004, fast-neutron imaging was incorporated into the system. In 2007, the ONV decided to develop a fieldable version of the system, designated as FNMIS, for potential use in future treaties. The FNMIS is being developed to be compatible with the eventual incorporation of gamma-ray spectrometry and an information barrier. This report addresses how and what attributes could be determined by the FNMIS system with gamma-ray spectrometry. The NMIS is a time-dependent coincidence system that incorporates tomographic imaging (including mapping of the fission sites) and gamma-ray spectrometry. It utilizes a small, lightweight (30 lb), portable deuterium-tritium (DT) neutron (14.1 MeV) generator (4 x 10 7 neutrons/second) for active interrogation and can also perform passive interrogation. A high-purity germanium (HPGe) gamma-ray detector with multichannel analysis can be utilized in conjunction with the source for active interrogation or passively. The system uses proton recoil scintillators: 32 small 2.5 x 2.5 x 10.2-cm-thick plastic scintillators for imaging and at least two 2 x 2 arrays of 27 x 27 x 10-cm-thick plastic scintillators that detect induced fission radiation. The DT generator contains an alpha detector that time and directionally tags a fan beam of some of the neutrons emitted and subdivides it into pixels. A fast (1 GHz) time correlation processor measures the time-dependent coincidence among all detectors in the system. A computer-controlled scanner moves the small detectors and the source appropriately for scanning a target object for imaging. The system is based on detection of transmitted 14.1 MeV neutrons, fission neutrons, and gamma rays from spontaneous, inherent source fission of the target, fission neutrons and gamma rays induced by the external DT source, gamma rays from natural emissions of uranium and plutonium, and induced gamma-ray emission by the interaction of the 14.1 MeV neutrons from the DT source. The NMIS can and has been used with a time-tagged californium spontaneous fission source. It has also been used with pulsed interrogation sources such as LINACs, DT, and deuterium-deuterium (DD) sources. This system is uniquely suited for detection of shielded highly enriched uranium (HEU), plutonium, and other special nuclear materials and detection of high explosives (HE) and chemical agents. The NMIS will be adapted to utilize a trusted processor that incorporates information barrier and authentication techniques using open software and then be useful in some international applications for materials whose characteristics may be classified. The proposed information barrier version of the NMIS system would consist of detectors and cables, the red (classified side) computer system, which processes the data, and the black (unclassified side) computer, which handles the computer interface. The system could use the 'IB wrapper' concept proposed by Los Alamos National Laboratory and the software integrity (digital signatures) system proposed by Sandia. Since it is based entirely on commercially available components, the entire system, including NMIS data acquisition boards, can be built with commercial off-the-shelf components. This system is being developed into a fieldable system (FNMIS) for potential arms control treaties by the ONV. The system will be modularly constructed with the RF shielded modules connected to the processor by appropriate control and signal cable in metal conduit. The FNMIS is presently being designed for eventual incorporation of gamma-ray spectrometry and an information barrier to protect classified information. The system hardware and software can be configured to obtain the following: plutonium presence, plutonium mass, Pu-240/239 ratio, plutonium geometry, plutonium metal vs non-metallic (absence of metal), time (age) since processing for plutonium (or last purification), uranium presence, uranium mass, uranium enrichment, uranium geometry, uranium metal vs non-metallic compound (absence of metal), beryllium presence and mass, tritium and deuterium gas bottle presence, HE, and chemical weapons. A matrix of the quantities determined, the method of determination, whether active (external neutron source) or passive, and the measurement equipment involved is given in the Tables 1-4. Some of these attributes can be obtained by multiple data analysis methods. The gamma-ray spectrometry methods for HEU, plutonium, and HE have been developed by other laboratories, are well known, and will be incorporated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A range muon tomography performance study for the detection of explosives

Soft cosmic ray tomography has been shown to successfully discriminate materials with various density levels due to their ability to deeply penetrate matter, allowing sensitivity to atomic number, radiation length and density. Because the multiple muon scattering signal from high Z-materials is very strong, the technology is well suited to the detection of the illicit transportation of special and radiological nuclear materials. In addition, a recent detection technique based on measuring the lower energy particles that do not traverse the material (range radiography), allows to discriminate low and medium Z-materials. This is shown in [4] using Monte Carlo simulations. More recently, using a mini muon tracker developed at Los Alamos National Laboratory, we performed various experiments to try out the radiation length technology. This paper presents the results from real experiments and evaluates the likelihood that soft cosmic ray tomography may be applied to detect high-explosives.

36 MATERIALS SCIENCE↗

The Advanced Helical Generator

A high explosive pulsed power (HEPP) generator called the Advanced Helical Generator (AHG) has been designed, built, and successfully tested. The AHG incorporates design principles of voltage and current management to obtain a high current and energy gain. Its design was facilitated by the use of modern modeling tools as well as high precision manufacture. The result was a first-shot success. The AHG delivered 16 Mega-Amperes of current and 11 Mega-Joules of energy to a quasi-static 80 nH inductive load. A current gain of 154 times was obtained with a peak exponential rise time of 20 {micro}s. We will describe in detail the design and testing of the AHG.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗