Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resonance techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Advances in in situ/operando techniques for catalysis research: enhancing insights and discoveries

Abstract Catalysis research has witnessed remarkable progress with the advent of in situ and operando techniques. These methods enable the study of catalysts under actual operating conditions, providing unprecedented insights into catalytic mechanisms and dynamic catalyst behavior. This review discusses key in situ techniques and their applications in catalysis research. Advances in in situ electron microscopy allow direct visualization of catalysts at the atomic scale under reaction conditions. In situ spectroscopy techniques like X-ray absorption spectroscopy and nuclear magnetic resonance spectroscopy can track chemical states and reveal transient intermediates. Synchrotron-based techniques offer enhanced capabilities for in situ studies. The integration of in situ methods with machine learning and computational modeling provides a powerful approach to accelerate catalyst optimization. However, challenges remain regarding radiation damage, instrumentation limitations, and data interpretation. Overall, continued development of multi-modal in situ techniques is pivotal for addressing emerging challenges and opportunities in catalysis research and technology.

Chen, Linfeng↗

Absorption and resonance Raman spectra of Pb2, Pb3, and Pb4 in xenon matrices

Matrix isolation techniques are used to investigate the spectra of lead molecules and, in particular, to obtain resonance Raman spectra of lead vapors isolated in solid xenon matrices. The presence of Pb2 is confirmed by the visible adsorption, and Raman spectra yield a vibrational frequency for the ground state of 108 per cm and a dissociation energy of 8200 per cm. A second resonance Raman progression indicates a Pb3 species of D3h symmetry. Finally, two additional Raman features at approximately 111 per cm spacing are evidence for a third species, tentatively identified as Pb4.

Stranz, D. D.↗

Precise Frequency Measurements Using a Superconducting Cavity Stabilized Oscillator

Many physics experiments call on improved resolution to better define the experimental results, thus improving tests of theories. Modern microwave technology combined with high-Q resonators can achieve frequency readout and control with resolutions up to a part in 10(exp 18). When the physical quantity in question in the experiment can be converted to a frequency or a change in frequency, a high-stability microwave oscillator can be applied to obtain state-of-the-art precision. In this work we describe the overall physical concepts and the required experimental procedures for optimizing a high-resolution frequency measurement system that employs a high-Q superconducting microwave cavity and a low-noise frequency synthesizer. The basic approach is to resolve the resonant frequencies of a high-Q (Q > 10(exp 10)) cavity to extremely high precision (one part in 10(exp 17)- 10(exp 18)). Techniques for locking the synthesizer frequency to a resonant frequency of the superconducting cavity to form an ultra-stable oscillator are described. We have recently set up an ultra-high-vacuum high-temperature annealing system to process superconducting niobium cavities, and have been able to consistently achieve Q > 10(exp 9). We have integrated high-Q superconducting cavities with a low-noise microwave synthesizer in a phase-locked-loop to verify the frequency stability of the system. Effects that disturb the cavity resonant frequency (such as the temperature fluctuations and mechanical vibrations) and methods to mitigate those effects are also considered. Applicability of these techniques to experiments will be discussed, and our latest experimental progress in achieving high-resolution frequency measurements using the superconducting-cavity-stabilized-oscillator will be presented.

Strayer, D. M.↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

Inelastic Light Scattering Processes

Five different inelastic light scattering processes will be denoted by, ordinary Raman scattering (ORS), resonance Raman scattering (RRS), off-resonance fluorescence (ORF), resonance fluorescence (RF), and broad fluorescence (BF). A distinction between fluorescence (including ORF and RF) and Raman scattering (including ORS and RRS) will be made in terms of the number of intermediate molecular states which contribute significantly to the scattered amplitude, and not in terms of excited state lifetimes or virtual versus real processes. The theory of these processes will be reviewed, including the effects of pressure, laser wavelength, and laser spectral distribution on the scattered intensity. The application of these processes to the remote sensing of atmospheric pollutants will be discussed briefly. It will be pointed out that the poor sensitivity of the ORS technique cannot be increased by going toward resonance without also compromising the advantages it has over the RF technique. Experimental results on inelastic light scattering from I(sub 2) vapor will be presented. As a single longitudinal mode 5145 A argon-ion laser line was tuned away from an I(sub 2) absorption line, the scattering was observed to change from RF to ORF. The basis, of the distinction is the different pressure dependence of the scattered intensity. Nearly three orders of magnitude enhancement of the scattered intensity was measured in going from ORF to RF. Forty-seven overtones were observed and their relative intensities measured. The ORF cross section of I(sub 2) compared to the ORS cross section of N2 was found to be 3 x 10(exp 6), with I(sub 2) at its room temperature vapor pressure.

Fouche, Daniel G.↗

Information-Guided Dynamic Nuclear Polarization

A spin ensemble in thermal equilibrium continuously undergoes random fluctuations analogous to those observed in Brownian motion, a process known as spin noise. Here, we investigate the dynamics of a system comprising a spin-1 paramagnetic center and a hyperfine-coupled spin-1/2 nucleus in the vicinity of a level crossing. We theoretically show that nuclear spins polarize efficiently under the combined action of thermal fluctuations and a closed-loop feedback protocol. The latter articulates periodic observations of the electronic magnetization and radio-frequency pulses connecting hybrid states with opposite nuclear spin alignment. Since nuclear polarization emerges from electronic spin fluctuations, not spin order, this microwave-free technique generically benefits from warmer, not colder, operation temperatures. Furthermore, because the spin dynamics at play near a level crossing is rather insensitive to the absolute value of the magnetic field, our work promises opportunities for high-field dynamic nuclear polarization, which is difficult to attain through present methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗

An active antenna for ELF magnetic fields

The work of Nikola Tesla, especially that directed toward world-wide electrical energy distribution via excitation of the earth-ionosphere cavity resonances, has stimulated interest in the study of these resonances. Not only are they important for their potential use in the transmission of intelligence and electrical power, they are important because they are an integral part of our natural environment. This paper describes the design of a sensitive, untuned, low noise active antenna which is uniquely suited to modern earth-ionosphere cavity resonance measurements employing fast-Fourier transform techniques for near-real-time data analysis. It capitalizes on a little known field-antenna interaction mechanism. Recently, the authors made preliminary measurements of the magnetic fields in the earth-ionosphere cavity. During the course of this study, the problem of designing an optimized ELF magnetic field sensor presented itself. The sensor would have to be small, light weight (for portable use), and capable of detecting the 5-50 Hz picoTesla-level signals generated by the natural excitations of the earth-ionosphere cavity resonances. A review of the literature revealed that past researchers had employed very large search coils, both tuned and untuned. Hill and Bostick, for example, used coils of 30,000 turns wound on high permeability cores of 1.83 m length, weighing 40 kg. Tuned coils are unsuitable for modern fast-Fourier transform data analysis techniques which require a broad spectrum input. 'Untuned' coils connected to high input impedance voltage amplifiers exhibit resonant responses at the resonant frequency determined by the coil inductance and the coil distributed winding capacitance. Also, considered as antennas, they have effective areas equal only to their geometrical areas.

Sutton, John F.↗

CARS Spectral Fitting with Multiple Resonant Species using Sparse Libraries

The dual pump CARS technique is often used in the study of turbulent flames. Fast and accurate algorithms are needed for fitting dual-pump CARS spectra for temperature and multiple chemical species. This paper describes the development of such an algorithm. The algorithm employs sparse libraries, whose size grows much more slowly with number of species than a conventional library. The method was demonstrated by fitting synthetic "experimental" spectra containing 4 resonant species (N2, O2, H2 and CO2), both with noise and without it, and by fitting experimental spectra from a H2-air flame produced by a Hencken burner. In both studies, weighted least squares fitting of signal, as opposed to least squares fitting signal or square-root signal, was shown to produce the least random error and minimize bias error in the fitted parameters.

Cutler, Andrew D.↗

Search for New Bosons in Gluon-Gluon and Vector Boson Fusion Processes at the LHC and Development of Silicon Module Assembly Techniques for the CMS High Granularity Calorimeter

A search for heavy resonances decaying to a pair of vectors bosons is presented which utilizes events in which a hadronically decaying Z or W boson is identified using jet substructure techniques and large missing transverse momentum is found. Data analyzed were recorded by the Compact Muon Solenoid experiment at the CERN Large Hadron Collider in 2016, 2017, and 2018, and correspond to 137 fb$^{-1}$ . The events are categorized as having arisen from Vector Boson Fusion process or not, and are characterized by their transverse mass distribution. The standard model backgrounds are estimated based on observed yields in control regions. No excess of events above the expected SM background are observed and limits are placed on the production cross section of Radion (spin-0), Wprime (spin-1) and Bulk graviton (spin2) particles. In adiditon, the high luminosity LHC and the CMS HGCAL upgrade are also presented. The assembly techniques and various tests for the Silicon module and the cassette are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced visible-light-assisted peroxymonosulfate activation on cobalt-doped mesoporous iron oxide for orange II degradation

Sulfate radical-based advanced oxidation processes (SR-AOP) attracted a lot of attention due to their capability and adaptability in wastewater treatment. Although heterogeneous cobalt-based catalysts have been extensively studied and have emerged superior for peroxymonosulfate (PMS) activation, leaching of cobalt is still a major concern. Herein, we report a photo-assisted PMS activation approach using cobalt doped mesoporous iron oxide with exceptional activity and stability up to 7 cycles with very low cobalt leaching (0.5 ppm). The highest activity was obtained by 1 mol % cobalt doped mesoporous iron oxide. Orange II dye was completely degraded by the reactive oxygen species (ROS) generated under visible light irradiation within 1 min. ROS were evaluated using two distinct techniques (Fluorescence probes and Electron Paramagnetic Resonance (EPR). ROS quenching experiments were also used to highlight the dominant pathway. This study correlates the structural and electronic changes induced with cobalt doping to the exceptional activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing ethane phase changes in bead pack via high-field NMR spectroscopy

Phase equilibria analysis in two-phase systems requires discernment of the individual phases as well as the interfacial region. The phase behavior of fluids in constraint geometries have been studied through several techniques. High-Field Nuclear Magnetic Resonance (HF-NMR) can be used to detect fluid phases, i.e. gas, liquid, or supercritical fluid, in the bulk or under confinement. In solution-state HF-NMR, each phase exhibits a distinct chemical shift that correlates to the phase density. In turn, the emergence of multimodal in NMR spectra reveals the coexistence of multiple phases in fluid systems. Our results for ethane show that HF-NMR can enable tracking phase changes in the bulk, but also in macro-scale (10–100's μm in pore size) porous systems at various pressure and temperature conditions, even when the system us out of equilibrium. Finally, these results creates potential opportunities to investigate phase changes influenced by confinement in porous systems, though additional steps are necessary.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Protecting air/moisture-sensitive samples using perdeuterated paraffin wax for solid-state NMR experiments under magic-angle spinning

Solid-state nuclear magnetic resonance (SSNMR) spectroscopy is a powerful technique for materials characterization, yet its application to air- and moisture-sensitive materials is often hindered by the difficulty in maintaining an inert environment during magic-angle spinning (MAS). This is particularly true for fast-MAS rotors that do not generally provide tight seals. Herein, we present a generalizable approach employing perdeuterated paraffin waxes—n-icosane-d42 and c-dodecane-d24—as protective embedding media to analyze sensitive organometallic catalysts using SSNMR. We demonstrate that these waxes significantly slow oxidative degradation under MAS conditions. Weak background 1 H and 13 C NMR signals from the waxes are effectively suppressed using double-quantum filtration and cross-polarization techniques. In conclusion, these findings offer a robust method for expanding the scope of SSNMR to air-sensitive systems, with implications for the structural study of reactive materials and catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual-Salt Electrolytes to Effectively Reduce Impedance Rise of High-Nickel Lithium-Ion Batteries

Simply mixing several lithium salts in one electrolyte to obtain blended salt electrolytes has been demonstrated as a promising strategy to formulate advanced electrolytes for lithium metal batteries (LMBs) and lithium-ion batteries (LIBs). In this study, we report the use of dual-salt electrolytes containing lithium hexafluorophosphate (LiPF6) and lithium difluorophosphate (LiDFP) in ethylene carbonate/ethyl methyl carbonate (EC/EMC) mixture and tested them in layered high-nickel LIB cells. LiNi 0.94 Co 0.06 O 2 was synthesized through a coprecipitation method and was used as a representative high-nickel cathode for the U.S. DOE realizing next-generation cathode (RNGC) deep dive program. The ionic conductivity of dual-salt electrolytes can be maintained by controlling the amount of LiDFP. Techniques including 1 H Nuclear Magnetic Resonance (NMR), X-ray photoelectron spectroscopy (XPS), inductively coupled plasma-mass spectrometry (ICP-MS), and differential voltage analysis (DVA) were used to understand the improved performance. Additionally, the multifaceted benefits of using the dual-salt electrolytes include (1) reduced transesterification, (2) formation of a stable cathode electrolyte interface, and (3) mitigation of cathode degradation at high voltages, especially stabilization of oxide particles during the H 2 <-> H 3 transformation.

25 ENERGY STORAGE↗

Electron Sextets as Optically Addressable Molecular Qubits: Triplet Carbenes

There is a growing demand in quantum information science and sensing for electron spin purification and readout via a spin-optical interface. This technique, known as optically detected magnetic resonance (ODMR), has been applied to diamond-NV centers and transition-metal complexes. Metal-free counterparts of these optically addressable spin qubits promise to be cheaper, more sustainable color centers with prolonged polarization lifetimes. However, progress has been hindered by the low ODMR signals of carbon-based π-diradicals, partly due to the lack of a ground singlet-to-triplet intersystem crossing (ISC). In this work, we propose exploring organic systems that are even more electron-deficient: electron sextets. Using triplet carbenes as an example, we illustrate how the ground singlet-triplet gap can be widened beyond thermal energy with the associated singlet-to-triplet ISC made available by vibronic effects. Through careful molecular engineering, this ISC can occur at a rate similar to and with an opposite spin selectivity from the excited-state ISC well-established in π-diradicals, unlocking a new ODMR pathway with potential signal gains. Persistent triplet carbenes are a renascent field, with multiple stable molecules being isolated in the past five years. To motivate further development of its emissive properties, we illustrate our design in three realistic carbene candidates that incorporate existing strategies for carbene stabilization. Furthermore, we believe that a new realm of quantum materials can be uncovered by expanding our scope toward stable electron sextets.

Carbene compounds↗

Nanoscale imaging of Gilbert damping using signal amplitude mapping

Ferromagnetic resonance force microscopy (FMRFM) is a powerful scanned probe technique that uses sub-micrometer-scale, spatially localized standing spin wave modes (LMs) to perform local ferromagnetic resonance (FMR) measurements. In this work, we show the spatially resolved imaging of Gilbert damping in a ferromagnetic material (FM) using FMRFM. Typically damping is measured from the FMR linewidth. We demonstrate an approach to image the spatial variation of Gilbert damping utilizing the LM resonance peak height to measure the LM resonance cone angle. This approach enables determination of damping through field-swept FMRFM at a single excitation frequency. The extreme force sensitivity of similar to 2 fN at room temperature can resolve changes of Gilbert damping as small as ~2 x 10 -4 at 2GHz, corresponding to ~0.16Oe in FMR linewidth resolution. This high sensitivity, high spatial resolution, and single frequency imaging of Gilbert damping creates the opportunity to study spin interactions at the interface between an insulating FM and a small volume of nonmagnetic material such as atomically thin two-dimensional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗