Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Accurate prediction of short-range order and its effect on thermodynamic, structural, and electronic properties of disordered alloys: exemplified in archetypical Cu 3 Au

Electronic-structure methods based on density-functional theory (DFT) were used to quantify the effect of chemical short-range order (SRO) on thermodynamic, structural, and electronic properties of archetypal face-centered-cubic (fcc) Cu3Au alloy. We showed that SRO can be tuned to alter bonding and lattice dynamics (i.e., phonons) and detail how these properties are changed with SRO. Thermodynamically favorable SRO significantly improved the phase stability of fcc Cu3Au from -0.0343 eV-atom -1 to –0.0682 eV-atom -1 . We used our DFT-based linear-response theory to predict SRO and its electronic origin, and accurately estimate the observed transition temperature, ordering instability (L1 2 ), and Warren-Cowley SRO parameters, in agreement with experiments. The accurate prediction of real-space SRO gives an edge over computationally and resource intensive approaches such as monte-carlo methods or experiments, which will enable large scale molecular dynamic simulations by providing supercells with optimized SRO. Here we also analyzed phonon dispersion and estimated the vibrational entropy change (from 9kB at 300 K to 6kB at 100 K) in fcc Cu3Au. We established from SRO analysis that exclusion of chemical interactions may lead to a skewed view of true properties in chemically complex alloys. The first-principles methods described in this work are generally applicable to any arbitrary solid-solution alloys, including multi-principal-element alloys, therefore, holds promise for designing technologically useful materials.

36 MATERIALS SCIENCE↗

Automated co-adding and energy calibration of large array microcalorimeter data with zero sample knowledge

State-of-the-art microcalorimeter spectrometers now contain large detector arrays with hundreds of individual pixels. Each individual pixel outputs a unique and non-linear response with respect to deposited energy. This work describes a pattern-recognition algorithm to combine these responses into a single energy-calibrated histogram, referred to as co-adding pixels. Photo-peaks from different pixels are matched together based upon how well the match aligns the centroids and heights of neighboring peaks. This usually results in around 100 co-adding calibration points from 30 to 300 keV for a several day acquisition of plutonium items with masses between 0.5 and 10 grams. An additional algorithm energy-calibrates this co-added spectrum using the fluoresced K x-ray emissions from a tantalum absorber and inherent x-ray escape peaks from the tin absorbers. Both algorithms operate without knowledge of the source and are fully automated. This work presents results from the acquisitions of high and low burnup plutonium, 10% enriched uranium, a 153 Gd calibration source, and a 57 Co+ 166m Ho calibration source. In all measurements, resolution defined as the full-width at half-maximum (FWHM) of photo-peaks is preserved between the individual pixel and co-added spectra at around 65 eV for incident photon energies between 60 and 208 keV. The energy calibration algorithm is approximate and yields a calibration curve off by an average of around 200 eV for incident photon energies between 60 and 208 keV.

47 OTHER INSTRUMENTATION↗

Ultracentral Collisions of Small and Deformed Systems at RHIC

We study a range of collision systems involving deformed ions and compare the elliptic and triangular flow harmonics produced in a hydrodynamics scenario versus a color glass condensate (CGC) scenario. For the hydrodynamics scenario, we generate initial conditions using TRENTO and work within a linear response approximation to obtain the final flow harmonics. For the CGC scenario, we use the explicit calculation of two-gluon correlations taken in the high-p T “(semi)dilute-(semi)dilute” regime to express the flow harmonics in terms of the density profile of the collision. Here, we consider ultracentral collisions of deformed ions as a testbed for these comparisons because the difference between tip-on-tip and side-on-side collisions modifies the multiplicity dependence in both scenarios, even at zero impact parameter. We find significant qualitative differences in the multiplicity dependence obtained in the initial conditions+hydrodynamics scenario and the CGC scenario, allowing these collisions of deformed ions to be used as a powerful discriminator between models. We also find that sub-nucleonic fluctuations have a systematic effect on the elliptic and triangular flow harmonics which are most discriminating in 0–1% ultracentral symmetric collisions of small deformed ions and in 0–10% d197Au collisions. The collision systems we consider are 238 U 238 U, d 197 Au, 9 Be 197 Au, 9 Be 9 Be, 3 He 3 He, and 3 He 197 Au.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metal-embedded fiber optic sensor packaging and signal demodulation scheme towards high-frequency dynamic measurements in harsh environments

Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.

47 OTHER INSTRUMENTATION↗

A heat flux sensor leveraging the transverse Seebeck effect in elemental antimony

Certain configurations of anisotropic single crystal materials can generate a thermoelectric voltage orthogonal to an induced temperature gradient. This phenomenon is known as the Transverse Seebeck Effect (TSE) and can be leveraged to fabricate simple and robust heat flux sensors. Only a small number of materials have been considered as TSE-based transducers and, among these, few have been developed into sensors with ruggedization against chemical and mechanical degradation. Here, we report on the fabrication and characterization of a rugged TSE-based heat flux sensor using prismatic antimony single crystals. The heat flux sensor was tested under static and dynamic heating scenarios. The sensor has a linear responsivity of 16.8 µV/(W/cm2) to heat fluxes spanning more than two orders of magnitude and a time constant of 4.4 s. The sensor’s response to localized heating, probed with a laser scanning technique, validated that the transduction mechanism is primarily the TSE by ruling out a sizable contribution from the conventional Seebeck effect. Finite element analysis corroborated that components used in the sensor package are the primary determinants of the time constant and the decrement of the responsivity from its theoretical maximum. Design principles that may be applied to elicit a faster transient response or higher responsivity are proposed. Furthermore, the results establish single crystal antimony as a promising transducer material for heat flux measurement systems and demonstrate potential effects of ruggedization on sensor performance.

36 MATERIALS SCIENCE↗

A note on the reverse Michaelis-Menten kinetics

We theoretically derive a general equation describing the enzyme kinetics that can be further simplified to the typical Michaelis-Menten (M-M) kinetics and the reverse M-M equation (RM-M) proposed by Schimel and Weintraub (2003). We discuss the conditions under which the RM-M is valid with this theoretical derivation. These conditions are contrary to the assumptions of Schimel and Weintraub (2003) and limit the applicability of the model in field soil environments. Nonetheless, Schimel and Weintraub s RM-M model is useful and has the ability to produce a non-linear response of SOM decomposition to enzyme concentration consistent with observations. Regardless of the theoretical basis, if we assume that the M-M and the RM-M could be equivalent, our sensitivity analysis indicates that enzyme plays a more sensitive role in the M-M kinetics compared with in the RM-M kinetics.

54 ENVIRONMENTAL SCIENCES↗

Sensitive Immunoassays of Nitrated Fibrinogen in Human Biofluids

Three new sandwich immunoassays for detection of nitrated biomarker have been established with potential applications in biomedical studies and clinical practice. In this study, nitrated human fibrinogen, a potential oxidative stress biomarker for several pathologies, was chosen as the target. To improve the sensitivity and overcome the interference caused by the complexity of human biofluids, we developed three sandwich strategies using various combinations of primary antibody and secondary antibody. All three strategies demonstrated high sensitivity and selectivity towards nitrated forms of fibrinogen in buffer, but their performances were dramatically reduced when tested with human plasma and serum samples. Systematically optimizations were carried out to investigate the effects of numerous factors, including sampling, coating, blocking, and immunoreactions. Our final optimization results indicate that two of these strategies retain sufficient sensitivity and selectivity for use as assays in human physiological samples. Specifically, detection limits reached the pM level and the linear response ranges were up to nM level with a correlation coefficient > 0.99. To our best knowledge, this is the first example of using an electrochemical immunoassay for a nitrated biomarker in a physiological fluid. This novel approach provides a rapid, sensitive, selective, cost efficient and robust bioassay for detection of oxidative stress in pathology and for clinical applications. Moreover, the sandwich strategies developed in this paper can be readily used to establish effective methods targeting other nitration biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Method development for comprehensive extraction and analysis of marine toxins: Liquid-liquid extraction and tandem liquid chromatography separations coupled to electrospray tandem mass spectrometry

Toxins from biological sources are recognized as potential chemical weapon threats, with saxitoxin and ricin listed by the chemical weapons convention (CWC) as schedule one agents (CWC reference). These two toxins represent a metabolite (saxitoxin) and protein (ricin) from algal and plant sources, respectively. An array of toxins have been listed as "select agents" by the Health and Human Services (HHS) select agent program, including ricin, abrin, saxitoxin, tetrodotoxin, specific paralytic alpha conotoxin peptides, T-2 toxin, diacetoxyscirpenols, botulinum toxins, and staphylococcal enterotoxins [1]. The quantities of these toxins dictate whether they are considered select agents with federal oversight of their storage and use. While this list captures some of the naturally occurring toxins that may pose a threat to the public, there are a number of other naturally occurring toxins that may also be a concern.

biodetection↗

Astrophysical gyrokinetics: turbulence in pressure-anisotropic plasmas at ion scales and beyond

Here, we present a theoretical framework for describing electromagnetic kinetic turbulence in a multi-species, magnetized, pressure-anisotropic plasma. The turbulent fluctuations are assumed to be small compared to the mean field, to be spatially anisotropic with respect to it and to have frequencies small compared to the ion cyclotron frequency. At scales above the ion-Larmor radius, the theory reduces to the pressure-anisotropic generalization of kinetic reduced magnetohydrodynamics (KRMHD) formulated. At scales at and below the ion-Larmor radius, three main objectives are achieved. First, we analyse the linear response of the pressure-anisotropic gyrokinetic system, and show it to be a generalization of previously explored limits. The effects of pressure anisotropy on the stability and collisionless damping of Alfvénic and compressive fluctuations are highlighted, with attention paid to the spectral location and width of the frequency jump that occurs as Alfvén waves transition into kinetic Alfvén waves. Secondly, we derive and discuss a very general gyrokinetic free-energy conservation law, which captures both the KRMHD free-energy conservation at long wavelengths and dual cascades of kinetic Alfvén waves and ion entropy at sub-ion-Larmor scales. We show that non-Maxwellian features in the distribution function change the amount of phase mixing and the efficiency of magnetic stresses, and thus influence the partitioning of free energy amongst the cascade channels. Thirdly, a simple model is used to show that pressure anisotropy, even within the bounds imposed on it by firehose and mirror instabilities, can cause order-of-magnitude variations in the ion-to-electron heating ratio due to the dissipation of Alfvénic turbulence. Our theory provides a foundation for determining how pressure anisotropy affects turbulent fluctuation spectra, the differential heating of particle species and the ratio of parallel and perpendicular phase mixing in space and astrophysical plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Luminescence-Based Spectroelectrochemical Sensor for [Tc(dmpe)3]2+/+ (dmpe = 1,2-bis(dimethylphosphino)ethane) within a Charge-Selective Polymer Film

A spectroelectrochemical sensor consisting of an indium tin oxide (ITO) optically transparent electrode (OTE) coated with a thin film of sulfonated polystyrene-blockpoly(ethylene-ran-butylene)-block-polystyrene (SSEBS) was developed for [Tc(dmpe)3]+.. [Tc(dmpe)3]+ preconcentrated by ion-exchange into the SSEBS film after 20 min exposure to aqueous [Tc(dmpe)3]+ solution, resulting in a 14-fold increase in cathodic peak current compared to a bare OTE. Colorless [Tc(dmpe)3]+ was reversibly oxidized to colored [Tc(dmpe)3]2+ by cyclic voltammetry. Detection of [Tc(dmpe)3]2+ was accomplished by electrochemically cycling the complex between non-emissive [Tc(dmpe)3]+ and emissive [Tc(dmpe)3]2+ and monitoring the modulated emission (λexc = 532 nm; λem = 660 nm). The sensor gave a linear response over the range of 0.16 to 340.0 µM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic Electrochemical Sensing Platform for Biomonitoring of Exposure to Organophosphorus Pesticides and Nerve Agents Based on Simultaneous Measurement of Total Enzyme Amount and Enzyme Activity

We report a new approach for electrochemical quantification of enzymatic inhibition and phosphorylation for biomonitoring of exposure to organophosphorus (OP) pesticides and nerve agents based on a magnetic beads (MBs) immunosensing platform. The principle of this approach is based on the combination of MBs immuno-capture based enzyme activity assay and competitive immunoassay of total amount of enzyme for simultaneous detection of enzyme inhibition and phosphorylation in biological fluids. Butyrylcholinesterase (BChE) was chosen as a model enzyme. In competitive immunoassay, the target total BChE in a sample (mixture of OP-inhibited BChE and active BChE) competes with the BChE modified on the MBs to bind to the limited anti-BChE antibody labeled with quantum dots (QDs-anti-BChE), and followed by electrochemical stripping analysis of the bound QDs conjugate on the MBs. This assay shows a linear response over the total BChE concentration range of 0.1~20 nM. Simultaneously, real time BChE activity was measured on an electrochemical carbon nanotube-based sensor coupled with microflow injection system after immuno-capture by MBs-anti-BChE conjugate. Therefore, the formed phosphorylated adduct (OP-BChE) can be estimated by the difference values of the total amount BChE (including active and OP-inhibited) and active BChE from established calibration curves. This approach not only eliminates the difficulty in screening of low-dose OP exposure (less than 20% inhibition of BChE) because of individual variation of BChE values, but also avoids the drawback of the scarce availability of OP-BChE antibody. It is sensitive enough to detect 0.5 nM OP-BChE, which is less than 2% BChE inhibition. This method offers a new method for rapid, accurate, selective and inexpensive quantification of phosphorylated adducts and enzyme inhibition for biomonitoring of OP and nerve agent exposures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magnetic Electrochemical Immunoassays with Quantum Dot Labels for Detection of Phosphorylated Acetylcholinesterase in Plasma

A new magnetic electrochemical immunoassay has been developed as a tool for biomonitoring exposures to organophosphate (OP) compounds, e.g., insecticides and chemical nerve agents, by directly detecting organophosphorylated acetylcholinesterase (OP-AChE). This immunoassay uniquely incorporates highly efficient magnetic separation with ultrasensitive square wave voltammetry (SWV) analysis with quantum dots (QDs) as labels. A pair of antibodies was used to achieve the specific recognition of OP-AChE that was prepared with paraoxon as an OP model agent. Antiphosphoserine polyclonal antibodies were anchored on amorphous magnetic particles preferably chosen to capture OP-AChE from the sample matrixes by binding their phosphoserine moieties that were exposed through unfolding the protein adducts. This was validated by electrochemical examinations and enzyme-linked immunosorbent assays. Furthermore, antihuman AChE monoclonal antibodies were labeled with cadmium-source QDs to selectively recognize the captured OP-AChE, as characterized by transmission electron microscopy. The subsequent electrochemical SWV analysis of the cadmium component released by acid from the coupled QDs was conducted on disposable screen-printed electrodes. Experimental results indicated that the SWV-based immunoassays could yield a linear response over a broad concentration range of 0.3-300 ng/mL OP-AChE in human plasma with a detection limit of 0.15 ng/mL. Such a novel electrochemical immunoassay holds great promise as a simple, selective, sensitive, and field-deployable tool for the effective biomonitoring and diagnosis of potential exposures to nerve agents and pesticides.

59 BASIC BIOLOGICAL SCIENCES↗

Smartphone-based Dual-channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-phenoxybenzoic acid

Currently, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC-MS and LC-MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultra-high fluorescent brightness were synthesized and used as signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCDs conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in sample. The red fluorescence on the test line then was recorded by a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 ng/mL to 100 ng/mL and from 0.1 ng/mL to 100 ng/mL, the limits of detection were calculated to be ~0.35 ng/mL for cypermethrin and ~0.04 ng/mL for 3-PBA, respectively. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.

Zhao, Yuting↗

Quantifying Carbon-14 for Biology Using Cavity Ring-Down Spectroscopy

A cavity ring-down spectroscopy (CRDS) instrument was developed using mature, robust hardware for the measurement of carbon-14 in biological studies. The system was characterized using carbon-14 elevated glucose samples and returned a linear response up to 387 times contemporary carbon-14 concentrations. Carbon-14 free and contemporary carbon-14 samples with varying carbon-13 concentrations were used to assess the method detection limit of approximately one-third contemporary carbon-14 levels. Sources of inaccuracies are presented and discussed, and the capability to measure carbon-14 in biological samples is demonstrated by comparing pharmacokinetics from carbon-14 dosed guinea pigs analyzed by both CRDS and accelerator mass spectrometry. Here, the CRDS approach presented affords easy access to powerful carbon-14 tracer techniques that can characterize complex biochemical systems.

07 ISOTOPE AND RADIATION SOURCES↗

Screened Range-Separated Hybrid Functional with Polarizable Continuum Model Overcomes Challenges in Describing Triplet Excitations in the Condensed Phase Using TDDFT

Long range-corrected (LRC) or range-separated hybrid (RSH) functionals where the long-range (LR) limit of electronic interactions is set to the exact exchange have been shown to correct the tendency of traditional density functional theory (DFT) to underestimate the frontier orbital gap. Consequently, the use of such functionals in calculating electronic excited states using linear response based time-dependent DFT (TDDFT) has been successful in correcting the tendency for underestimating the energies of charge transfer states by DFT-based calculations. More recently formulations of functionals that attenuate the LR limit to address condensed-phase effects to polarize the electronic density have been reported. In particular screened RSH (SRSH) combined with polarizable continuum model (PCM) was benchmarked successfully in reproducing the fundamental gap and charge transfer state energies of molecular systems in the condensed phase. Here we use SRSH-PCM to address triplet excited states, and show its success in obtaining correspondence of the low-lying triplet states to the singlet–triplet gap in a similar way that the fundamental orbital gap corresponds to electron removal and addition energies. Importantly, the accuracy of the SRSH-PCM in calculating triplet excitations stands on the polarization consistent framework in addressing the scalar dielectric constant and without affecting the optimal tuning by triplet energies. Finally, the prospect of even further improving the SRSH-PCM accuracy in calculating triplet states can be achieved by optimal tuning on the basis of the spin multiplicity gap.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First Principles Nonadiabatic Excited-State Molecular Dynamics in NWChem

Computational simulation of non-adiabatic molecular dynamics is an indispensable tool for understanding complex photoinduced processes such as internal conversion, energy transfer, charge separation, and spatial localization of excitons, to name a few. Here, we report an implementation of the fewest-switches surface hopping algorithm in the NWChem computational chemistry program. Here the surface hopping method is combined with linear-response time-dependent density functional theory calculations of adiabatic excited state potential energy surfaces. To treat quantum transitions between arbitrary electronic Born{Oppenheimer states, we have implemented both numerical and analytical differentiation schemes for derivative non-adiabatic couplings. A numerical approach for the time-derivative non-adiabatic couplings together with an analytical method for calculating non-adiabatic coupling vectors is an efficient combination for surface hopping approaches. Additionally, electronic decoherence schemes and a state reassigned unavoided crossings algorithm are also implemented to improve the accuracy of the simulated dynamics and to handle trivial unavoided crossings. We apply our code to study the ultrafast decay of photoexcited benzene, including a detailed analysis of the potential energy surface, population decay time scales, and vibrational coordinates coupled to the excitation dynamics. The development presented in this work is a baseline for future implementations of more sophisticated frameworks for simulating of non-adiabatic molecular dynamics in NWChem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Ab Initio Multiple Cloning Method for Non-Adiabatic Excited-State Molecular Dynamics in NWChem

The recently developed ab-initio multiple cloning (AIMC) approach based on the multicongurational Ehrenfest (MCE) method provides a powerful and accurate way of describing the excited-state dynamics of molecular systems. The AIMC method is a controlled approximation to non-adiabatic dynamics with a particular strength in the proper description of decoherence effects due to branching of vibrational wavepackets at a level crossing. In this work, we report a new implementation of the AIMC algorithm in the open source NWChem computational chemistry program. The framework combines linear-response time-dependent density functional theory with Ehrenfest mean-eld theory to determine the equations of motion for classical trajectories. The multi-dimensional wave function is decomposed into a superposition of Gaussian coherent states guided by Ehrenfest trajectories (i.e., MCE approach), which can clone with fully quantum mechanical amplitudes and phases. By using an efficient time-derivative based non-adiabatic coupling approach within the AIMC method, all observable are calculated on-the-y in the non-adiabatic molecular dynamics process. As a representative example, we apply our implementation to study the ultrafast photoinduced electronic and vibrational energy transfer in a pyridine molecule. The effects of the cloning procedure on electronic and vibrational coherence, relaxation and unidirectional energy transfer are discussed. This new AIMC implementation provides a high-level non-adiabatic molecular dynamics framework for simulating photoexcited dynamics in complex molecular systems and experimentally relevant ultrafast spectroscopic probes, such as nonlinear coherent optical and X-ray signals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extracting Inelastic Scattering Cross Sections for Finite and Aperiodic Materials from Electronic Dynamics Simulations

Explicit time-dependent electronic structure theory methods are increasingly prevalent in the areas of condensed matter physics and quantum chemistry, with the broad-band optical absorptivity of molecular and small condensed-phase systems nowadays routinely studied with such approaches. Here, in this paper, it is demonstrated that electronic dynamics simulations can similarly be employed to study cross sections for the scattering-induced electronic excitations probed in nonresonant inelastic X-ray scattering and momentum-resolved electron energy loss spectroscopies. A method is put forth for evaluating the electronic dynamic structure factor, which involves the application of a momentum boost-type perturbation and transformation of the resulting reciprocal space density fluctuations into the frequency domain. Good agreement is first demonstrated between the dynamic structure factor extracted from these electronic dynamics simulations and the corresponding transition matrix elements from linear response theory. The method is then applied to some extended (quasi)one-dimensional systems, for which the wave vector becomes a good quantum number in the thermodynamic limit. Finally, the dispersion of many-body excitations in a series of hydrogen-terminated graphene flakes (and twisted bilayers thereof) is investigated to highlight the utility of the presented approach for capturing morphology-dependent effects in the inelastic scattering cross sections of nanostructured and/or noncrystalline materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗