Search NASA⌕ Search

SEARCH · Search NASA

Results for “time shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

WE-A-BRC-00: The Quality Gap

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-01: Introduction to the Certificate Course

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-02: Lessons Learned: Clinical Trials and Operations

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-03: Lessons Learned: IROC Audits

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

A mass quadrupole spectrometry investigation on proton emission by nanosecond laser ablation

A nanosecond pulsed Nd:YAG laser operating at the fundamental wavelength of 1064 nm and at an intensity of about 10{sup 10} W/cm{sup 2} was employed to irradiate hydrogenated polymers in vacuum. The produced plasma was characterized in terms of thermal and Coulomb interactions evaluating the equivalent temperature and the acceleration voltage developed in the non-equilibrium plasma core. Particles emission along the normal to the target surface was investigated by measuring, with the Hiden EQP 300 mass quadrupole spectrometer, ion energy distributions and fitting experimental data with the “Coulomb-Boltzmann-shifted” function. Time-of-flight technique was employed in order to measure the proton energy and yield. A comparison between experimental results is presented and discussed, with a special regard to the protons emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Luminescence Properties of FZ Silicon Irradiated with Swift Heavy Ions

The optical properties of float-zone (FZ) silicon irradiated with swift heavy ions (SHI) are studied. In the low-temperature photoluminescence spectra, a broad peak in the range 1.3–1.5 μm is evident along with the well-known X, W, W', R, and C lines. In this case, it is found that, as the irradiation dose is increased in the range 3 × 10{sup 11}–10{sup 13} cm{sup –2}, the photoluminescence peak falls and narrows and, at the same time, its maximum shifts to longer wavelengths.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Operando Acoustic Monitoring of SEI Formation and Long-Term Cycling in NMC/SiGr Composite Pouch Cells

Stable long-term cycling and solid-electrolyte-interphase (SEI) formation are key challenges in the design of Si/graphite composites as Li-ion battery (LIB) anode materials. Typically, these long-term cycling properties are examined in flooded half-cell settings making use of a Li-metal counter electrode and a Si/graphite working electrode. This form factor has the advantage of offering an unlimited supply of Li-ions and electrolyte, thus isolating performance degradation to the passivation of the working electrode. However, half-cell studies are ineffective in revealing performance and degradation mechanisms of the Si/graphite composite in a more commercially realistic full cell setting. This paper outlines an operando acoustic technique that can offer insights on SEI formation and capacity degradation of Si/graphite composites in a full cell setting. Through a combination of electrochemical and chemical analyses, we show that increasing passivation of the silicon particles in the Si/graphite composite anode is correlated with an increase in the acoustic time-of-flight shift. We further show that temporary loss of the acoustic signal during the first cycle is associated with significant gassing of the cell. The operando acoustic technique outlined here is low-cost, simple to setup and has the potential for localized resolution, indicating usefulness in commercial-scale Si/graphite cell quality control and diagnosis.

42 ENGINEERING↗

Development of an Outdoor Temperature-Based Control Algorithm for Residential Mechanical Ventilation Control

Smart ventilation systems use controls to ventilate more during those periods that provide either an energy or IAQ advantage (or both) and less during periods that provide a dis advantage. Using detailed building simulations, this study addresses one of the simplest and lowest cost types of smart controllers —outdoor temperature- based control. If the outdoor temperature falls below a certain cut- off, the fan is simply turned off. T he main principle of smart ventilation used in this study is to shift ventilation from time periods with large indoor -outdoor temperature differences, to periods where these differences are smaller, and their energy impacts are expected to be less. Energy and IAQ performance are assessed relative to a base case of a continuously operated ventilation fan sized to comply with ASHRAE 62.2-2013 whole house ventilation requirements. In order to satisfy 62.2-2013, annual pollutant exposure must be equivalent between the temperature controlled and continuous fan cases. This requires ventilation to be greater than 62.2 requirements when the ventilation system operates. This is achieved by increasing the mechanical ventilation system air flow rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Net Metering and Market Feedback Loops: Exploring the Impact of Retail Rate Design on Distributed PV Deployment

The substantial increase in deployment of customer-sited solar photovoltaics (PV) in the United States has been driven by a combination of steeply declining costs, financing innovations, and supportive policies. Among those supportive policies is net metering, which in most states effectively allows customers to receive compensation for distributed PV generation at the full retail electricity price. The current design of retail electricity rates and the presence of net metering have elicited concerns that the possible under-recovery of fixed utility costs from PV system owners may lead to a feedback loop of increasing retail prices that accelerate PV adoption and further rate increases. However, a separate and opposing feedback loop could offset this effect: increased PV deployment may lead to a shift in the timing of peak-period electricity prices that could reduce the bill savings received under net metering where time-varying retail electricity rates are used, thereby dampening further PV adoption. In this paper, we examine the impacts of these two competing feedback dynamics on U.S. distributed PV deployment through 2050 for both residential and commercial customers, across states. Our results indicate that, at the aggregate national level, the two feedback effects nearly offset one another and therefore produce a modest net effect, although their magnitude and direction vary by customer segment and by state. We also model aggregate PV deployment trends under various rate designs and net-metering rules, accounting for feedback dynamics. Our results demonstrate that future adoption of distributed PV is highly sensitive to retail rate structures. Whereas flat, time-invariant rates with net metering lead to higher aggregate national deployment levels than the current mix of rate structures (+5% in 2050), rate structures with higher monthly fixed customer charges or PV compensation at levels lower than the full retail rate can dramatically erode aggregate customer adoption of PV (from -14% to -61%, depending on the design). Moving towards time-varying rates, on the other hand, may accelerate near- and medium-term deployment (through 2030), but is found to slow adoption in the longer term (-22% in 2050).

14 SOLAR ENERGY↗

SNL Contribution: Consequence Analysis for Moisture Remaining in Dry Storage Canisters After Drying

This report discusses several possible sources of water that could persist in SNF dry storage canisters through the drying cycle. In some cases, the water is trapped in occluded geometries in the cask such as dashpots or damaged fuel. Persistence of water or ice in such locations seems unlikely, given the high heat load of the canistered fuel; this is especially true in the case of vacuum drying, where a strong driver exists to remove water vapor from the headspace of such occluded geometries. Water retention in Boral® core material is a known problem, that has in the past resulted in the need for much extended drying times. Since the shift to slightly higher porosity "blister resistant" Boral®, water drainage appears to be less of a problem. However, high surface areas for the Boral® core material will provide a trap for significant amounts of adsorbed water, at least some of which is certain to survive the drying process. Moreover, if corrosion within the cores produces hydrous aluminum corrosion products, these may also survive.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Artificial-feedback system

System suppresses spurious sinusoidal responses of any sinusoidally driven amplifier showing time-dependent phase shift versus frequency function. System is applicable to any sinusoidally driven amplifier. Technique eliminates, or reduces, unwanted spurious vibrations during tests to determine dynamic frequency responses of mechanical systems.

Sutton, J. F.↗

Lunar topography - Global determination by radar.

Previous methods used for two-dimensional radar mapping of the moon are contrasted with new techniques that add altitude information to the radar map. Delay-Doppler stereoscopy and delay-Doppler interferometry are shown to provide surface-height variations with higher accuracy and better global fidelity than has been possible previously. Sample results are presented for altitude contours on the moon as obtained with the Haystack and Westford radar systems of the Massachusetts Institute of Technology. An appendix describes the mathematical principles of delay-Doppler interferometry in determining the position of an arbitrary reflecting region of the lunar surface from measurements of the time delay, Doppler shift, and fringe phase of radar echoes from that region.

Shapiro, I. I.↗

System measurements of a CO2 laser communications link

Measurements were made under simulated operating conditions to establish the capability of a CO2 laser transmitting heterodyne receiver link to acquire weak laser transmitter beams and maintain spatial tracking during communications. For the case of a synchronous satellite-to-earth station link, analysis and laboratory measurements indicate that the infrared heterodyne receiver subsystem is capable of performing the acquisition, acquisition confirm, and spatial tracking functions at IF signal-to-noise ratio of -17 dB. For the case of a low-altitude satellite-to-earth station link, the laser transmit signal is Doppler-shifted due to the difference in relative velocity of the two stations. The resultant Doppler frequency shift varies with time and must be spectrally acquired and tracked.

Peyton, B. J.↗

Improvements and validation of the erythropoiesis control model for bed rest simulation

The most significant improvement in the model is the explicit formulation of separate elements representing erythropoietin production and red cell production. Other modifications include bone marrow time-delays, capability to shift oxyhemoglobin affinity and an algorithm for entering experimental data as time-varying driving functions. An area of model development is suggested by applying the model to simulating onset, diagnosis and treatment of a hematologic disorder. Recommendations for further improvements in the model and suggestions for experimental application are also discussed. A detailed analysis of the hematologic response to bed rest including simulation of the recent Baylor Medical College bed rest studies is also presented.

Leonard, J. I.↗

Training state agency personnel in satellite remote sensing technology - Solutions to a special problem

To aid state/local agencies in starting effective programs to apply Landsat and other remote sensing data, NASA's Eastern Regional Remote Sensing Applications Center (ERRSAC) has developed a comprehensive training program as part of its technology transfer mission. Skills in data processing and interpretation are produced through 'hands-on' experience with computer techniques used to conduct practical applications involving state-oriented projects, conducted jointly by agencies and ERRSAC. In time, ERRSAC will shift much of these training activities to universities where future agency personnel can obtain a broader foundation in remote sensing.

Short, N. M.↗

Proton NMR studies of the electronic structure of ZrH/sub x/

The proton spin lattice relaxation times and Knight shifts were measured in f.c.c. (delta-phase) and f.c.t. (epsilon-phase) ZrH/sub x/ for 1.5 or = to x or = to 2.0. Both parameters indicate that N(E/sub F/) is very dependent upon hydrogen content with a maximum occurring at ZrH1 83. This behavior is ascribed to modifications in N(E/sub F/) through a fcc/fct distortion in ZrH/sub x/ associated with a Jahn-Teller effect.

Attalla, A.↗