Search NASA⌕ Search

SEARCH · Search NASA

Results for “2D SCANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Probing Light Atoms at Subnanometer Resolution: Realization of Scanning Transmission Electron Microscope Holography

Atomic resolution imaging of light elements in electron-transparent materials has long been a challenge. Biomolecular materials, for example, are rapidly altered by incident electrons. We demonstrate a scanning transmission electron microscopy (STEM) technique, called STEM holography, capable of efficient structural analysis of beam-sensitive nanomaterials. STEM holography measures the absolute phase and amplitude of electrons passed through a specimen via interference with a vacuum reference wave. We use an amplitude-dividing nanofabricated grating to prepare multiple beams focused at the sample. We configure the postspecimen microscope imaging system to overlap the beams, forming an interference pattern. We record and analyze the pattern at each 2D-raster-scan-position, reconstructing the complex object wave. As a demonstration, we image gold nanoparticles on an amorphous carbon substrate at 2.4 Å resolution. In conclusion STEM holography offers higher contrast of the carbon while maintaining gold atomic lattice resolution compared to high angle annular dark field STEM.

4D-STEM↗

SU-E-CAMPUS-T-05: Preliminary Results On a 2D Dosimetry System Based On the Optically Stimulated Luminescence of Al2O3

Purpose: To develop a precise 2D dose mapping technique based on the optically stimulated luminescence (OSL) from Al{sub 2}O{sub 3} films for medical applications. Methods: A 2D laser scanning reader was developed using fast F{sup +}-center (lifetime of <7 ns) and slow F-center (lifetime of 35 ms) OSL emission from newly developed Al{sub 2}O{sub 3} films (Landauer Inc.). An algorithm was developed to correct images for both material and system properties. Since greater contribution of the F??-center emission in the recorded signal increases the readout efficiency and robustness of image corrections, Al{sub 2}O{sub 3}:C,Mg film samples are being investigated in addition to Al{sub 2}O{sub 3}:C samples. Preliminary investigations include exposure of the films to a 6 MV photon beam at 10 cm depth in solid water phantom with an SSD of 100 cm, using a 10 cm × 10 cm flat field or a 4 cm × 4 cm field with a 60° wedge filter. Kodak EDR2 radiographic film and EBT2 Gafchromic film were also exposed for comparison. Results: The results indicate that the algorithm is able to correct images and calculate 2D dose. For the wedge field irradiation, the calculated dose at the center of the field was 0.9 Gy for Al{sub 2}O{sub 3}:C and 0.87 Gy for Al{sub 2}O{sub 3}:C,Mg, whereas, the delivered dose was 0.95 Gy. A good qualitative agreement of the dose profiles was obtained between the OSL films and EDR2 and EBT2 films. Laboratory tests using a beta source suggest that a large dynamic range (10{sup −2}−10{sup 2} Gy) can be achieved using this technique. Conclusion: A 2D dosimetry system and an in-house image correction algorithm were developed for 2D film dosimetry in medical applications. The system is in the preliminary stage of development, but the data demonstrates the feasibility of this approach. This work was supported by Landauer, Inc.

36 MATERIALS SCIENCE↗

WE-AB-BRB-08: Progress Towards a 2D OSL Dosimetry System Using Al2O3:C Films

Purpose: To develop a 2D dosimetry system based on the optically stimulated luminescence (OSL) of Al{sub 2}O{sub 3}:C films for medical applications. Methods: A 2D laser scanning OSL reader was built for readout of newly developed Al2O3:C films (Landauer Inc.). An image reconstruction algorithm was developed to correct for inherent effects introduced by reader design and detector properties. The system was tested using irradiations with photon and carbon ion beams. A calibration was obtained using a 6 MV photon beam from clinical accelerator and the dose measurement precision was tested using a range of doses and different dose distributions (flat field and wedge field). The dynamic range and performance of the system in the presence of large dose gradients was also tested using 430 MeV/u {sup 12}C single and multiple pencil beams. All irradiations were performed with Gafchromic EBT3 film for comparison. Results: Preliminary results demonstrate a near-linear OSL dose response to photon fields and the ability to measure dose in dose distributions such as flat field and wedge field. Tests using {sup 12}C pencil beam demonstrate ability to measure doses over four orders of magnitude. The dose profiles measured by the OSL film generally agreed well with that measured by the EBT3 film. The OSL image signal-to-noise ratio obtained in the current conditions require further improvement. On the other hand, EBT3 films had large uncertainties in the low dose region due to film-to-film or intra-film variation in the background. Conclusion: A 2D OSL dosimetry system was developed and initial tests have demonstrated a wide dynamic range as well as good agreement between the delivered and measured doses. The low background, wide dynamic range and wide range of linearity in dose response observed for the Al{sub 2}O{sub 3}:C OSL film can be beneficial for dosimetry in radiation therapy applications, especially for small field dosimetry. This work has been funded by Landauer Inc. Dr. Eduardo G. Yukihara also would like to thank the Alexander von Humboldt Foundation for his support at the DKFZ.

60 APPLIED LIFE SCIENCES↗

Reaching the third dimension

X-ray imaging is extensively used in medical and materials science. Traditionally, the depth dimension is obtained by turning the sample to gain different views. The famous penetrating properties of X-rays mean that projection views of the subject sample can be readily obtained in the linear absorption regime. 180 degrees of projections can then be combined using computed tomography (CT) methods to obtain a full 3D image, a technique extensively used in medical imaging. In the work now presented in Nature Materials, Stephan Hruszkewycz and colleagues have demonstrated genuine 3D imaging by a new method called 3D Bragg projection ptychography1. Our approach combines the 'side view' capability of using Bragg diffraction from a crystalline sample with the coherence capabilities of ptychography. Thus, it results in a 3D image from a 2D raster scan of a coherent beam across a sample that does not have to be rotated.

36 MATERIALS SCIENCE↗

Exploring 3D elastic-wave scattering at interfaces using high-resolution phased-array system

The elastic-wave scattering at interfaces, such as cracks, is essential for nondestructive inspections, and hence, understanding the phenomenon is crucial. However, the elastic-wave scattering at cracks is very complex in three dimensions since microscopic asperities of crack faces can be multiple scattering sources. We propose a method for exploring 3D elastic-wave scattering based on our previously developed high-resolution 3D phased-array system, the piezoelectric and laser ultrasonic system (PLUS). We describe the principle of PLUS, which combines a piezoelectric transmitter and a 2D mechanical scan of a laser Doppler vibrometer, enabling us to resolve a crack into a collection of scattring sources. Subsequently, we show how the 3D elastic-wave scattering in the vicinity of each response can be extracted. Here, we experimentally applied PLUS to a fatigue-crack specimen. We found that diverse 3D elastic-wave scattering occurred in a manner depending on the responses within the fatigue crack. This is significant because access to such information will be useful for optimizing inspection conditions, designing ultrasonic measurement systems, and characterizing cracks. More importantly, the described methodology is very general and can be applied to not only metals but also other materials such as composites, concrete, and rocks, leading to progress in many fields.

36 MATERIALS SCIENCE↗

Octahedral distortion induced magnetic anomalies in LaMn{sub 0.5}Co{sub 0.5}O{sub 3} single crystals

Single crystals of LaMn{sub 0.5}Co{sub 0.5}O{sub 3} belonging to the ferromagnetic-insulator and distorted perovskite class were grown using a four-mirror optical float zone furnace. The as-grown crystal crystallizes into an orthorhombic Pbnm structure. The spatially resolved 2D Raman scan reveals a strain-induced distribution of transition metal (TM)–oxygen (O) octahedral deformation in the as-grown crystal. A rigorous annealing process releases the strain, thereby generating homogeneous octahedral distortion. The octahedra tilt by reducing the bond angle TM-O-TM, resulting in a decline of the exchange energy in the annealed crystal. The critical behavior is investigated from the bulk magnetization. It is found that the ground state magnetic behavior assigned to the strain-free LaMn{sub 0.5}Co{sub 0.5}O{sub 3} crystal is of the 3D Heisenberg kind. Strain induces mean field-like interaction in some sites, and consequently, the critical exponents deviate from the 3D Heisenberg class in the as-grown crystal. The temperature-dependent Raman scattering study reveals strong spin-phonon coupling and the existence of two magnetic ground states in the same crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cosmological constraints on light but massive relics

Many scenarios of physics beyond the standard model predict new light, weakly coupled degrees of freedom, populated in the early universe and remaining as cosmic relics today. Due to their high abundances, these relics can significantly affect the evolution of the universe. For instance, massless relics produce a shift ΔN eff to the cosmic expectation of the effective number of active neutrinos. Massive relics, on the other hand, additionally become part of the cosmological dark matter in the later universe, though their light nature allows them to freely stream out of potential wells. This produces novel signatures in the large-scale structure (LSS) of the universe, suppressing matter fluctuations at small scales. Here, we present the first general search for such light (but massive) relics (LiMRs) with cosmic microwave background (CMB) and LSS data, scanning the 2D parameter space of their masses m X and temperatures $T^{(0)}_{X}$ today. In the conservative minimum-temperature ($T^{(0)}_{X}$ = 0.91 K) scenario, we rule out Weyl (and higher-spin) fermions -- such as the gravitino -- with m X ≥ 2.26 eV at 95% C.L., and set analogous limits of m X ≤ 11.2,1.06,1.56 eV for scalar, vector, and Dirac-fermion relics. This is the first search for LiMRs with joint CMB, weak-lensing, and full-shape galaxy data; we demonstrate that weak-lensing data is critical for breaking parameter degeneracies, while full-shape information presents a significant boost in constraining power relative to analyses with only baryon acoustic oscillation parameters. Under the combined strength of these datasets, our constraints are the tightest and most comprehensive to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Simplified Procedure for Estimating Epitaxy of La2Zr2O7-Buffered NiW RABITS Using XRD

Abstract A procedure is developed for assessing the epitaxy of La(2-x)Zr(2+x)O(7) (LZO) layers on NiW RABITS. Comparing XRD patterns (theta / 2-theta scans and 2D rocking curves) of LZO films of known thickness (ellipsometry or reflectometry measurements) with those of standard samples (100% epitaxial LZO film and an isotropic LZO pellet of known density), we estimate the epitaxial (EF), and polycrystalline (PF) fractions of LZO within the layer. The procedure was tested using MOD-LZO(100 nm)/NiW tape samples with varied from 3 to 90% (reproducibly prepared by varying the humidity of Ar-5%H2 gas during heat treatment). A qualitative agreement with RHEED and quantitative (within 10%) agreement with the EBSD results was shown. Correlation between EF and Jc in 600 nm thick YBCO layer deposited on MOD-LZO/NiW using thermal coevaporation enables us to impose the EF=80% margin on the quality of LZO layer for the particular conductor architecture.

36 MATERIALS SCIENCE↗

Short-Lived Intermediate in the N2O Generation by P450 NO Reductase Captured by Time-Resolved IR Spectroscopy and XFEL Crystallography

Diffraction images were collected using an MX300-HS CCD detector. For each cryoloop, 2D raster scan with 50 μm step in each direction was performed twice. In the second pass, the raster-scan grid was shifted 25 μm in each direction. In cheetah directory, - {puck_name}/{pin_id}_hits.h5 correspond to the first scan, and - {puck_name}/{pin_id}-2_hits.h5 correspond to the second scan.

BL3↗

Global SUSY fits

Explore the source record for details and available documents.

2D SCANS↗

Basal Plane Hydrogen Evolution Activity from Mixed Metal Nitride MXenes Measured by Scanning Electrochemical Microscopy

2D early transition metal carbide and nitride MXenes have intriguing properties for electrochemical energy storage and electrocatalysis. These properties can be manipulated by modifying the basal plane chemistry. Here, mixed transition metal nitride MXenes, M-Ti 4 N 3 T x (M = V, Cr, Mo, or Mn; T x = O and/or OH), are developed by modifying pristine exfoliated Ti 4 N 3 T x MXene with V, Cr, Mo, and Mn salts using a simple solution-based method. The resulting mixed transition metal nitride MXenes contain 6–51% metal loading (cf. Ti) that exhibit rich electrochemistry including highly tunable hydrogen evolution reaction (HER) electrocatalytic activity in a 0.5 m H 2 SO 4 electrolyte as follows: V-Ti 4 N 3 T x > Cr-Ti 4 N 3 T x > Mo-Ti 4 N 3 T x > Mn-Ti 4 N 3 T x > pristine Ti 4 N 3 T x with overpotentials as low as 330 mV at -10 mA cm -2 with a charge-transfer resistance of 70 O. Scanning electrochemical microscopy (SECM) reveals the electrochemical activity of individual MXene flakes. The SECM data corroborate the bulk HER activity trend for M-Ti 4 N 3 T x as well as provide the first experimental evidence that HER results from catalysis on the MXene basal plane. These electrocatalytic results demonstrate a new pathway to tune the electrochemical properties of MXenes for water splitting and related electrochemical applications.

2D materials↗

Polychromatic X-ray Micro- and Nanodiffraction for Spatially-Resolved Structural Studies

The availability of intense, focused synchrotron X-ray microbeams has enabled new techniques for materials investigations with sub-micron spatial resolution. The scanning microbeam setup we have developed at the XOR-UNI beamline at the Advanced Photon Source (APS) is versatile in that it provides 1D, 2D or 3D scans (including depth resolution), and can alternate between polychromatic- and monochromatic-beam modes. Focusing in both modes uses elliptical Kirkpatrick-Baez (K-B) reflecting mirrors. Beam diameters of {approx} 500 nm FWHM are now routine, and 90 nm focus has been demonstrated. In white-beam mode, a CCD detector records a complete Laue diffraction pattern, which is analyzed with an automated indexing program. These X-ray diffraction patterns provide real-space maps of the local lattice structure, crystal orientation, grain morphology, and strain tensor. Spatially-resolved X-ray microdiffraction studies are now providing previously unavailable measurements of local microstructures. These measurements, in turn, yield new insights in several classic fields of materials science. This paper will illustrate the application of polychromatic scanning X-ray microscopy with examples from 1D, 2D and 3D materials systems. In 1D systems, we have mapped the structure and orientation of an individual ZnO nanorod along with the associated Ge catalyst particle used to control the nanocrystal growth. In 2D systems, X-ray microdiffraction studies have revealed the mechanisms for local crystallographic tilting in epitaxial oxide films grown on textured Ni substrates for superconducting applications. In 3D systems, X-ray microscopy investigations have included in-situ studies of microstructural evolution during thermal grain growth in polycrystalline aluminum. In general, these spatially-resolved measurements provide important new insights and are valuable as input for theoretical and computer modeling studies of a wide range of material processes.

43 PARTICLE ACCELERATORS↗

Light-Dependent Impedance Spectra and Transient Photoconductivity in a Ruddlesden–Popper 2D Lead–Halide Perovskite Revealed by Electrical Scanned Probe Microscopy and Accompanying Theory

Electric force microscopy was used to record the light-dependent impedance spectrum and the probe transient photoconductivity of a film of butylammonium lead iodide, BA 2 PbI 4 , a 2D Ruddlesden–Popper perovskite semiconductor. The impedance spectrum of BA 2 PbI 4 showed modest changes as the illumination intensity was varied up to 1400 mW cm –2 , in contrast with the comparatively dramatic changes seen for 3D lead–halide perovskites under similar conditions. BA 2 PbI 4 ’s light-induced conductivity had a rise time and decay time of ~100 μs, 10 4 slower than expected from direct electron–hole recombination yet 10 5 faster than the conductivity-recovery times recently observed in 3D lead–halide perovskites and attributed to the relaxation of photogenerated vacancies. What sample properties are probed by electric force microscope measurements remains an open question. A Lagrangian-mechanics treatment of the electric force microscope experiment was recently introduced by Dwyer, Harrell, and Marohn which enabled the calculation of steady-state electric force microscope signals in terms of a complex sample impedance. Here this impedance treatment of the tip–sample interaction is extended, through the introduction of a time-dependent transfer function, to include time-resolved electrical scanned probe measurements. Here, it is shown that the signal in a phase-kick electric force microscope experiment, and therefore also the signal in a time-resolved electrostatic force microscope experiment, can be written explicitly in terms of the sample’s time-dependent resistance (i.e., conductivity).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Sensor Suite

The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. When looking for a sensor that would provide XYZ point cloud data for mapping the decision was between a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The selection between Lidars is detailed. The Hokuyo UTM-30LX-EW shown provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg.. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. The rotating planar scan from the 2D Lidar can be stitched into a 3D scan as shown in the graphic below. Along with XYZ data, the Lidar provides return intensity data in color which can be used to distinguish between different materials within the tunnel. To provide visual feedback a camera system needed to be identified. The common solution for this is a high resolution camera with a small FOV mounted on a pan-tilt system. But, given the critical nature of the visual feedback we looked into solutions without the need for moving parts. Two panospheric cameras give a FOV large enough to get a full 360 deg. view.. Camera color data (RGB) can also be combined with the 3D mapping data from the Lidar and overlaid on the map to give the user the ability to see inside the entire length of the tunnel as if they were inside. Situational awareness is required for the crawler in the tunnel in order for it to be able to register the 3D scans to create a final map. For this we procured a Microstrain 3DM-GX5-25 Inertial Measurement Unit (IMU). To perform the Lidar rotation we have two servos driving the pan and tilt. The servo controls and most data processing will be performed via an onboard computer. The sensor components are to be packaged together using 3D printed mounts into a standalone unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Autonomous fabrication of tailored defect structures in 2D materials using machine learning-enabled scanning transmission electron microscopy

Materials with tailored quantum properties can be engineered from atomic-scale assembly techniques, but existing methods often lack the agility and accuracy to precisely and intelligently control the manufacturing process. Here, we demonstrate a fully autonomous approach for fabricating atomic-level defects using electron beams in scanning transmission electron microscopy (STEM) that combines advanced machine learning and automated beam control. As a proof of concept, we achieved controlled fabrication of MoS-nanowire (MoS-NW) edge structures by iterative and targeted exposure of MoS 2 monolayer to a focused electron beam to selectively eject sulfur atoms, utilizing high-angle annular dark-field (HAADF) imaging for feedback-controlled monitoring of structural evolution of defects. A machine learning framework combining a random forest model and a convolutional neural network (CNN) was developed to decode the HAADF image and accurately identify atomic positions and species. This atomic-level information was then integrated into an autonomous decision-making platform, which applied predefined fabrication strategies to instruct beam control about atomic sites to be ejected. The selected sites were subsequently exposed to a localized electron beam using an FPGA-controlled scan routine with precise control over beam positioning and duration. While the MoS-NW edge structures produced exhibit promising mechanical and electronic properties, the proposed methods to build the autonomous fabrication framework is material-agnostic and can be extended to other 2D materials for the creation of diverse defect structures and heterostructures beyond Mo S2 .

Engineering↗

SU-D-BRE-04: Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam

Purpose: To evaluate the absolute dose accuracy of the PTW Octavius 729 XDR 2D ion chamber array at a high dose rate pencil beam scanning proton therapy facility. Methods: A set of 18 plans were created in our treatment planning system, each of which comprising a unique combination of field sizes (FS), length of spread out of Bragg peaks (SOBP) and depths. The parameters used were: FS of 5×5cm{sup 2}, 10×10cm{sup 2} and 15×15cm{sup 2}; flat SOBP of 5cm and 10cm; and isocenter depths of 10cm, 15cm and 20cm, which coincides with the center of the SOBP. The 2D array detector was positioned at the machine isocenter and the appropriate amount of solid water was used to match the planned depths of 10, 15 and 20 cm water equivalent depth. Subsequently, we measured the absolute dose at isocenter using a CC04 ion chamber in a 1D water tank. Both 2D array and CC04 were previously cross calibrated. We also collected the MU rates used by our proton machine from the log files. Results: The relative differences between the CC04 and the 2D array can be summarized into two groups, one with 5 cm SOBP and another with 10 cm SOBP. Plotting these datasets against FS shows that the 2D array response for high dose rate fields (FS of 5×5cm{sup 2} and 5cm SOBP) can be up to 2% lower. Similarly, plotting them against isocenter depths reveals the detector's response can be up to 2% lower for higher energy beams (about 200MeV nominal). The MU rate found in the machine log files for 5cm SOBP's were as high as twice the MU rate for the 10cm SOBP. Conclusion: The 2D array dose response showed a dose rate effect in scanning pencil beam delivery, which needs to be corrected to achieve a better dose accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

X-ray μ-Laue diffraction analysis of Cu through-silicon vias: A two-dimensional and three-dimensional study

Here, white X-ray μ-beam Laue diffraction is developed and applied to investigate elastic strain distributions in three-dimensional (3D) materials, more specifically, for the study of strain in Cu 10 μm diameter–80 μm deep through-silicon vias (TSVs). Two different approaches have been applied: (i) two-dimensional μ-Laue scanning and (ii) μ-beam Laue tomography. 2D μ-Laue scans provided the maps of the deviatoric strain tensor integrated along the via length over an array of TSVs in a 100 μm thick sample prepared by Focused Ion Beam. The μ-beam Laue tomography analysis enabled to obtain the 3D grain and elemental distribution of both Cu and Si. The position, size (about 3 μm), shape, and orientation of Cu grains were obtained. Radial profiles of the equivalent deviatoric strain around the TSVs have been derived through both approaches. The results from both methods are compared and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Pore structure refinement of cement paste incorporating nanosilica: Study with dual beam scanning electron microscopy/focused ion beam (SEM/FIB)

Highlights: • The modifying effects of nanosilica on pore structure of cement-based composites are investigated. • Dual beam SEM/FIB is implemented to create the 3D pore structure model and calculate porosity and pore size distribution. • The porosity and pore diameter are found to decrease with the inclusion of nanosilica. - Abstract: Pozzolanic materials, micro- and nano-, have been found to improve the durability properties of cement-based materials by refining their pore structure. As a relatively newer material, the modifying effects of nanosilica on pore structure are still inconclusive in the literature. In this study, this was characterized by implementing dual beam SEM/FIB, which can generate 3D models of porous materials for quantitative analysis. The sample is milled by focused ion beam layer-by-layer, and each surface layer is 2D imaged via scanning electron microscopy. Three types of pores – large capillary pore, medium capillary pore and gel pore – can be observed. A 3D pore structure model is then reconstructed from 1000 of these 2D images, from which porosity and pore size distribution can be calculated. Cement pastes incorporating nanosilica and silica fume were compared. The porosity and pore diameter were found to decrease with the inclusion of nanosilica. Furthermore, reduction in capillary pores and subsequent increase in gel pores were also observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗