Search NASA⌕ Search

SEARCH · Search NASA

Results for “Breakthrough Curves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Altona Field Lab Inverse Model WRR 2020

Includes data for measured inert tracer breakthrough curves first reported in Hawkins (2020) (Water Resources Research). In addition, this submission includes the production well temperature measurements first reported in Hawkins et al. (2017a) (Water Resources Research, volume 53, pp. 1210-1230). The data included requires MATLAB to view.

15 GEOTHERMAL ENERGY↗

EGS Collab Testbed 1: Second Set Tracer Test Results

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. The first multi-well experimental site was established at the 4850 level in the Homestake Mine in Lead, South Dakota, where hydraulic fractures were created at an injection well drilled sub-horizontal from the drift. This file contains the second set of tracer data (also include the data uploaded previously, https://gdr.openei.org/submissions/1128) for the EGS Collab testbed. The tracer tests were conducted during October 2018 - November 2019. Injected tracers include DNA, C-dots (fluorescein nano particles), fluorescein, rhodamine-b, sodium chloride, lithium bromide and cesium iodine. The tracers have been detected in three flowing wells located about 7.5 to 9 meters away from the injection interval. The tracer breakthrough curves from these locations have been adjusted to account for the residence time in the injection and production tubing. The details about the tracer test can be found in Background and Methods of Tracer Tests (Mattson et al. (2019,a,b)) (also included in this package). References Mattson, E.D., Neupane, G., Plummer, M.A., Hawkins, A., Zhang, Y. and the EGS Collab Team 2019a. Preliminary Collab fracture characterization results from flow and tracer testing efforts. In Proceedings 44th Workshop on Geothermal Reservoir Engineering, edited, Stanford University, Stanford, California. Mattson, E.D., Neupane, G., Hawkins, A., Burghardt, J., Ingraham, M., Plummer, M., and the EGS Collab Team, 2019b. Fracture tracer injection response to pressure perturbations at an injection well. GRC Transactions, Vol. 43, 2019. Neupane, Ghanashyam, Earl Mattson, Adam Hawkins, Mitchell Plummer, and Yuran Zhang. EGS Collab Testbed 1: Tracer data sets. No. 1128. DOE Geothermal Data Repository; Idaho National Laboratory, 2019.

15 GEOTHERMAL ENERGY↗

DECOVALEX-2023: Task F1 Final Report

DECOVALEX-2023 Task F is a comparison of models and methods for post-closure performance assessment (PA) of a deep geologic repository for radioactive waste. The general aims of Task F are to build confidence in the models, methods, and software used for PA and to stimulate additional research and development in PA methodologies. The task objectives are to motivate development of PA modelling skills and capabilities, to examine the influence of model choices on calculated repository performance, and to compare the uncertainties introduced by model choices to other sources of uncertainty. Task F involves no actual experiment or site. It is a PA modelling exercise that requires the conceptual development of hypothetical repository designs and geologic settings. Because three of the teams were interested in salt and the rest of the teams were interested in crystalline rock, Task F was split into two branches: Task F1 for crystalline rock and Task F2 for salt. This report is for Task F1, crystalline rock. Teams from seven countries (Canada, Czech Republic, Germany, Korea, Sweden, Taiwan, and United States) participated in Task F1. The teams worked together to define the features, events, and processes of the reference case repository and established a set of performance measures. In addition, they defined a set of benchmark problems designed to test and compare modelling capabilities for fracture flow and transport at different scales. The repository design and benchmark problems are documented in a Task Specification that evolved over time as the group honed the specifications. The benchmark problems verified that each team can aptly model flow and transport in fractured media in 1-, 2-, and 3-dimensions. Two general approaches were used for the 3-dimensional benchmarks: discrete fracture network (DFN) and equivalent continuous porous medium (ECPM). DFN modelling involves explicit meshing of each fracture while ECPM modelling aims to capture the effective porosity and directional permeability of each cell in a space-filling mesh as affected by intersecting fractures. In some models, a combination of the two is used, i.e., DFN for large known fractures and ECPM for the rest of the domain. Transport is solved by using either the advection-dispersion equation or particle tracking. Although some variation is observed among model breakthrough curves in the benchmark problems, there is strong agreement in breakthrough behaviour up to at least the 75 th percentile for all benchmarks. At the 90 th percentile, breakthrough results show larger differences, suggesting several models retain substantially higher fractions of tracer in regions of slower moving water. In addition to the flow and transport benchmarks, several teams completed the source term benchmark, verifying capabilities for modelling radionuclide decay and ingrowth, waste package breach, instant release fractions, fuel matrix degradation rates, and radionuclide solubility limitations. The reference case is conceptualized as a generic spent fuel repository at a depth of 450 m in fractured crystalline rock. The repository has 50 parallel backfilled drifts, each with 50 deposition holes 6 m apart. Each deposition hole contains a 4-PWR waste package and bentonite buffer. The rock domain is 5 km in length, 2 km in width, and 1 km in depth. It has 6 deterministic fractured deformation zones and a multitude of stochastic fractures. Teams generally used the ECPM approach for the entire rock or a hybrid approach in which the deterministic fracture zones are modelled with a DFN and the rest of the rock is modelled by ECPM. Of the reference case problems specified, only the results of the initial reference case problem are compared in this report. The initial problem focuses on transport from the deposition holes to the surface, i.e., it neglects waste package performance. Tracers are released at all waste package locations at time zero and tracked for their releases to the near field and ground surface. The water fluxes calculated at the ground surface entry and exit regions of the domain are similar for all models except for two that have considerably lower fluxes. For tracer transport, large differences are observed among models in the magnitude of tracer transported. Much of the difference appears to be due to how the repository is implemented and hence the different degrees of repository simplification. Models that exclude the drifts, buffer, and backfill from the domain tend to show greater release of tracers and radionuclides from the repository. The initial study presented here indicates that major differences in modelling important processes within the repository (e.g., diffusion through buffer and backfill) can produce broadly different release and transport results, especially when those processes are excluded. Even for the models that included all specified features, events, and processes, the results show significant differences and demonstrate the importance of examining multiple modelling approaches in performance assessment. The differences in results observed in this study are expected to motivate teams to either increase complexity in future versions of the reference case models or to improve methods to account for the effects of simplified features and processes. Either way, future improvements in these models are expected to produce results that more closely agree.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of Radionuclides from Waste Water at Fukushima Daiichi Nuclear Power Plant: Desalination and Adsorption Methods - 13126

Waste water containing high levels of radionuclides due to the Fukushima Daiichi Nuclear Power Plant accident, has been treated by the adsorption removal and reverse-osmosis (RO) desalination to allow water re-use for cooling the reactors. Radionuclides in the waste water are collected in the adsorbent medium and the RO concentrate (RO brine) in the water treatment system currently operated at the Fukushima Daiichi site. In this paper, we have studied the behavior of radionuclides in the presently applied RO desalination system and the removal of radionuclides in possible additional adsorption systems for the Fukushima Daiichi waste water treatment. Regarding the RO desalination system, decontamination factors (DFs) of the elements present in the waste water were obtained by lab-scale testing using an RO unit and simulated waste water with non-radioactive elements. The results of the lab-scale testing using representative elements showed that the DF for each element depended on its hydrated ionic radius: the larger the hydrated ionic radius of the element, the higher its DF is. Thus, the DF of each element in the waste water could be estimated based on its hydrated ionic radius. For the adsorption system to remove radionuclides more effectively, we studied adsorption behavior of typical elements, such as radioactive cesium and strontium, by various kinds of adsorbents using batch and column testing. We used batch testing to measure distribution coefficients (K{sub d}s) for cesium and strontium onto adsorbents under different brine concentrations that simulated waste water conditions at the Fukushima Daiichi site. For cesium adsorbents, K{sub d}s with different dependency on the brine concentration were observed based on the mechanism of cesium adsorption. As for strontium, K{sub d}s decreased as the brine concentration increased for any adsorbents which adsorbed strontium by intercalation and by ion exchange. The adsorbent titanium oxide had higher K{sub d}s and it was used for the column testing to obtain breakthrough curves under various conditions of pH and brine concentration. The breakthrough point had a dependency on pH and the brine concentration. We found that when the pH was higher or the brine concentration was lower, the longer it took to reach the breakthrough point. The inhibition of strontium adsorption by alkali earth metals would be diminished for conditions of higher pH and lower brine concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microbe Encapsulation for Selective Rare-Earth Recovery from Electronic Waste Leachates

Rare earth elements (REEs) are indispensable components of many green technologies and of increasing demand globally. However, refining REEs from raw materials using current technologies is energy intensive and enviromentally damaging. Here, we describe the development of a novel biosorption-based flow-through process for selective REE recovery from electronic wastes. An Escherichia coli strain previously engineered to display lanthanide-binding tags on the cell surface was encapsulated within a permeable polyethylene glycol diacrylate (PEGDA) hydrogel at high cell density using an emulsion process. This microbe bead adsorbent contained a homogenous distribution of cells whose surface functional groups remained accessible and effective for selective REE adsorption. The microbe beads were packed into fixed-bed columns, and breakthrough experiments demonstrated effective Nd extraction at a flow velocity of up to 3 m/h at pH 4–6. The microbe bead columns were stable for reuse, retaining 85% of the adsorption capacity after nine consecutive adsorption/desorption cycles. A bench-scale breakthrough curve with a NdFeB magnet leachate revealed a two-bed volume increase in breakthrough points for REEs compared to non-REE impurities and 97% REE purity of the adsorbed fraction upon breakthrough. These results demonstrate that the microbe beads are capable of repeatedly separating REEs from non-REE metals in a column system, paving the way for a biomass-based REE recovery system.

Biological and medical sciences↗

Hydrogen, Methane, Brine Flow Behavior, and Saturation in Sandstone Cores During H 2 and CH 4 Injection and Displacement

Large-scale underground hydrogen storage (UHS) is a critical component in the emerging hydrogen economy. Knowledge of multiphase flow behavior involving hydrogen in storage reservoir formations is crucial to characterizing hydrogen transport properties and essential for the deliverability and storage operations of UHS. There are still many gaps in fully understanding hydrogen–methane–brine multiphase phase flow that require further investigation. In this work, H 2 and CH 4 were injected through brine-saturated sandstone cores using a tri-axial core holder system fitted with flow rate meters and pressure transducers, while the effluent gas concentrations were analyzed using an online micro gas chromatograph. Brine displacement, permeability, and gas breakthrough curves were measured. We studied the flow behavior of hydrogen and methane in sandstone cores through testing brine displacement by gas injection and comparing the hydrogen displacement of methane with the methane displacement of hydrogen. We also tested the differences between horizontal and vertical flow in brine displacement. The results showed that brine displacement was more efficient in a core with higher permeability and porosity, resulting in a higher initial gas saturation. A higher gas injection rate brought about faster gas breakthrough measured by pore volume and sharper concentration curves. Hydrogen did not exhibit abnormal flow in the sandstone when the flow was horizontal and downward vertical. Gas overriding was observed in brine displacements when the flow was horizontal, with hydrogen showing this behavior more profoundly compared to methane. Downward vertical gas injection induced higher efficiency brine displacement compared to horizontal displacement and resulted in a higher initial gas saturation in the sandstone cores. These findings address critical knowledge gaps regarding gas flow patterns and displacement behaviors during hydrogen injection and recovery phases in UHS facilities using methane as the cushion gas. The insights from this research offer valuable guidance for optimizing UHS systems, ensuring operational efficiency, and advancing sustainable energy solutions in alignment with decarbonization goals.

08 HYDROGEN↗

Robust system size reduction of discrete fracture networks: a multi-fidelity method that preserves transport characteristics

In this paper, we propose a multi-fidelity system reduction technique that uses weighted graphs paired with three-dimensional discrete fracture network (DFN) modelling for efficient simulation of subsurface flow and transport in fractured media. DFN models are used to simulate flow and transport in subsurface fractured rock with low-permeability. One method to alleviate the heavy computational overhead associated with these simulations is to reduce the size of the DFN using a graph representation of it to identify the primary flow sub-network and only simulate flow and transport thereon. The first of these methods used unweighted graphs constructed solely on DFN topology and could be used for accurate predictions of first-passage times. However, these techniques perform poorly when predicting later stages of the mass breakthrough. We utilize a weighted-graph representation of the DFN where edge weights are based on hydrological parameters in the DFN that allows us to exploit the kinematic quantities derivable a posteriori from the flow solution obtained on the graph representation of the DFN to perform system reduction and predict the later stages of the breakthrough curve with high fidelity. We also propose and demonstrate the use of an adaptive pruning algorithm with error control that produces a pruned DFN sub-network whose predicted mass breakthrough agrees with the original DFN within a user-specified tolerance. Lastly, the method allows for the level of accuracy to be a user-controlled parameter.

58 GEOSCIENCES↗

Colloid-facilitated transport of 238 Pu, 233 U and 137 Cs through fractured chalk: Laboratory experiments, modelling, and implications for nuclear waste disposal

The influence of montmorillonite colloids on the mobility of 238 Pu, 233 U and 137 Cs through a chalk fracture was investigated to assess the transport potential for radioactive waste. Radioisotopes of each element, along with the conservative tracer tritium, were injected in the presence and absence of montmorillonite colloids into a naturally fractured chalk core. In parallel, batch experiments were conducted to obtain experimental sorption coefficients (K d , mL/g) for both montmorillonite colloids and the chalk fracture material. Breakthrough curves were modelled to determine diffusivity and sorption of each radionuclide to the chalk and the colloids under advective conditions. Uranium sorbed sparingly to chalk (log K d = 0.7 ± 0.2) in batch sorption experiments. 233 U(VI) breakthrough was controlled primarily by the matrix diffusion and sorption to chalk (15 and 25% recovery with and without colloids, respectively). Cesium, in contrast, sorbed strongly to both the montmorillonite colloids and chalk (batch log K d = 3.2 ± 0.01 and 3.9 ± 0.01, respectively). The high affinity to chalk and low colloid concentrations overwhelmed any colloidal Cs transport, resulting in very low 137 Cs breakthrough (1.1–5.5% mass recovery). Batch and fracture transport results, and the associated modelling revealed that Pu migrates both as Pu (IV) sorbed to montmorillonite colloids and as dissolved Pu(V) (7% recovery). Transport experiments revealed differences in Pu(IV) and Pu(V) transport behavior that could not be quantified in simple batch experiments but are critical to effectively predict transport behavior of redox-sensitive radionuclides. Finally, a brackish groundwater solution was injected after completion of the fracture flow experiments and resulted in remobilization and recovery of 2.2% of the total sorbed radionuclides which remained in the core from previous experiments. In general, our study demonstrates consistency in sorption behavior between batch and advective fracture transport. Finally, the results suggest that colloid-facilitated radionuclide transport will enhance radionuclide migration in fractured chalk for those radionuclides with exceedingly high affinity for colloids.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REAL WASTE TESTING OF SPHERICAL RESORCINOL-FORMALDEHYDE ION EXCHANGE RESIN

This report presents data on batch contact and column testing tasks for spherical resorcinol-formaldehyde (sRF) resin. The testing used a non-radioactive simulant of SRS Tank 2F dissolved salt, as well as an actual radioactive waste sample of similar composition, which are both notably high in sodium (6 M). The resin was Microbeads batch 5E-370/641 which had been made on the hundred gallon scale. Equilibrium batch contact work focused on cesium at a temperature of 25 C due to the lack of such data to better benchmark existing isotherm models. Two campaigns were performed with small-scale ion exchange columns, first with Tank 2F simulant, then with actual dissolved salt in the Shielded Cells. An extrapolation of the batch contact results with radioactive waste over-predicted the cesium loaded onto the IX sRF resin bed by approximately 11%. This difference is not unexpected considering uncertainties from measurement and extrapolation and because the ion exchange that occurs when waste flows through a resin bed probably cannot reach the same level of equilibrium as when waste and resin are joined in a long term batch contact. Resin was also characterized to better understand basic chemistry issues such as holdup of trace transition metals present in the waste feed streams. The column tests involved using two beds of sRF resin in series, with the first bed referred to as the Lead column and the second bed as the Lag column. The test matrix included two complete IX cycles for both the simulant and actual waste phases. A cycle involves cesium adsorption, until the resin in the Lead column reaches saturation, and then regenerating the sRF resin, which includes eluting the cesium. Both the simulated and the actual wastes were treated with two cycles of operation, and the resin beds that were used in the Lead and Lag columns of simulant test phase were regenerated and reused in the actual waste test phase. This task is the first to demonstrate the treatment of SRS waste with sRF resin and the tests clearly demonstrated cesium decontamination for actual waste. The results of the column tests were similar for both the simulated and the actual waste and demonstrated Cs removal with sRF from both wastes. For a flowrate of 1.4 bed volumes (BV)/hour at 25 C those results with sRF resin were: (1) Simulant and actual waste results are equivalent; (2) Cs breakthrough began between 200 and 250 BV; (3) Cs breakthrough reached 100% at around 400 BV; (4) Cs breakthrough curve from 5% to 100% is approximately linear; (5) Cs elution with 0.5 M HNO3 starts at 2 BV and ends at 6BV; (6) Most, if not all, of Cs adsorbed during treatment is released during elution; (7) At 100% breakthrough of Cs the resin bed adsorbs approximately 85% of full capacity before detection in the effluent; the remaining 15% is adsorbed at saturation; (8) Approximately 90% of resin bed changes (color and volume) are complete by 6 BV; and (9) During elution the resin shrinks to about 80% of its fully working (sodium form) BV.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of artificial topological changes on flow and transport through fractured media due to mesh resolution

Abstract We performed a set of numerical simulations to characterize the interplay of fracture network topology, upscaling, and mesh refinement on flow and transport properties in fractured porous media. We generated a set of generic three-dimensional discrete fracture networks at various densities, where the radii of the fractures were sampled from a truncated power-law distribution, and whose parameters were loosely based on field site characterizations. We also considered five network densities, which were defined using a dimensionless version of density based on percolation theory. Once the networks were generated, we upscaled them into a single continuum model using the upscaled discrete fracture matrix model presented by Sweeney et al. (2019). We considered steady, isothermal pressure-driven flow through each domain and then simulated conservative, decaying, and adsorbing tracers using a pulse injection into the domain. For each simulation, we calculated the effective permeability and solute breakthrough curves as quantities of interest to compare between network realizations. We found that selecting a mesh resolution such that the global topology of the upscaled mesh matches the fracture network is essential. If the upscaled mesh has a connected pathway of fracture (higher permeability) cells but the fracture network does not, then the estimates for effective permeability and solute breakthrough will be incorrect. False connections cannot be eliminated entirely, but they can be managed by choosing appropriate mesh resolution and refinement for a given network. Adopting octree meshing to obtain sufficient levels of refinement leads to fewer computational cells (up to a 90% reduction in overall cell count) when compared to using a uniform resolution grid and can result in a more accurate continuum representation of the true fracture network.

58 GEOSCIENCES↗

Collab Fracture Characterization: Preliminary Results from the Modeling and Flow Testing of Experiment 1

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. At the first experimental site, a hydraulic fracture will be created in metamorphic rock at the 4850 level in the former Homestake Mine. The experimental concept is for fracturing to be initiated at an injection well and continue until it intersects a production well approximately 10 meters away. Initial step-pressure flow testing of the fracture are to be performed to describe pressure-aperture-flow relationships. The flow field between the injector and producer boreholes will be characterized using a series of forced gradient dipole tracer tests. A number of fracture characterization models have been used to assist in the design of the tracer tests. The tracer test program will use conservative, sorbing, and particulate tracers, as well as sampling for radon gas to describe the fracture surface area (i.e., potential heat transfer area), flow pathway distribution, and volume. Tracer concentration at the production well (i.e. break through curves) will be measured using a series of inline sensors, liquid sampling devices, filtering of the effluent, and the measuring of gas concentrations in the effluent. Tracer monitoring data will be compared against results from a collection of numerical simulators developed at U.S. national laboratories and universities for the purpose of validating these flow and transport models. Ultimately these same models will be used to predict the heat transfer characteristics of the fracture and will be compared to a thermal characterization field test where cold water will be injected at the injection well and the temperature will be measured at the production well. This paper discusses the early tracer transport model predictions and parameters sensitivity that affect the tracer breakthrough curves at the production well.

Enhanced Geothermal Systems, EGS Collab, Sanford U↗

Collab Fracture Characterization: Preliminary Results from the Modeling and Flow Testing of Experiment 1

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. At the first experimental site, a hydraulic fracture will be created in metamorphic rock at the 4850 level in the former Homestake Mine. The experimental concept is for fracturing to be initiated at an injection well and continue until it intersects a production well approximately 10 meters away. Initial step-pressure flow testing of the fracture are to be performed to describe pressure-aperture-flow relationships. The flow field between the injector and producer boreholes will be characterized using a series of forced gradient dipole tracer tests. A number of fracture characterization models have been used to assist in the design of the tracer tests. The tracer test program will use conservative, sorbing, and particulate tracers, as well as sampling for radon gas to describe the fracture surface area (i.e., potential heat transfer area), flow pathway distribution, and volume. Tracer concentration at the production well (i.e. break through curves) will be measured using a series of inline sensors, liquid sampling devices, filtering of the effluent, and the measuring of gas concentrations in the effluent. Tracer monitoring data will be compared against results from a collection of numerical simulators developed at U.S. national laboratories and universities for the purpose of validating these flow and transport models. Ultimately these same models will be used to predict the heat transfer characteristics of the fracture and will be compared to a thermal characterization field test where cold water will be injected at the injection well and the temperature will be measured at the production well. This paper discusses the early tracer transport model predictions and parameters sensitivity that affect the tracer breakthrough curves at the production well.

15 GEOTHERMAL ENERGY↗

Off-Gas Adsorption Model Capabilities and Recommendations

Off-gas treatment is required to reduce emissions from aqueous fuel reprocessing. Evaluating the products of innovative gas adsorption research requires increased computational simulation capability to more effectively transition from fundamental research to operational design. Early modeling efforts produced the Off-Gas SeParation and REcoverY (OSPREY) model that, while efficient in terms of computation time, was of limited value for complex systems. However, the computational and programming lessons learned in development of the initial model were used to develop Discontinuous Galerkin OSPREY (DGOSPREY), a more effective model. Initial comparisons between OSPREY and DGOSPREY show that, while OSPREY does reasonably well to capture the initial breakthrough time, it displays far too much numerical dispersion to accurately capture the real shape of the breakthrough curves. DGOSPREY is a much better tool as it utilizes a more stable set of numerical methods. In addition, DGOSPREY has shown the capability to capture complex, multispecies adsorption behavior, while OSPREY currently only works for a single adsorbing species. This capability makes DGOSPREY ultimately a more practical tool for real world simulations involving many different gas species. While DGOSPREY has initially performed very well, there is still need for improvement. The current state of DGOSPREY does not include any micro-scale adsorption kinetics and therefore assumes instantaneous adsorption. This is a major source of error in predicting water vapor breakthrough because the kinetics of that adsorption mechanism is particularly slow. However, this deficiency can be remedied by building kinetic kernels into DGOSPREY. Another source of error in DGOSPREY stems from data gaps in single species, such as Kr and Xe, isotherms. Since isotherm data for each gas is currently available at a single temperature, the model is unable to predict adsorption at temperatures outside of the set of data currently available. Thus, in order to improve the predictive capabilities of the model, there is a need for more single-species adsorption isotherms at different temperatures, in addition to extending the model to include adsorption kinetics. This report provides background information about the modeling process and a path forward for further model improvement in terms of accuracy and user interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collab Fracture Characterization: Preliminary Results from the Modeling and Flow Testing of Experiment 1

The EGS Collab project is developing ~10-20 m-scale field sites where fracture stimulation and flow models can be validated against controlled, small-scale, in-situ experiments. At the first experimental site, a hydraulic fracture will be created in metamorphic rock at the 4850 level in the former Homestake Mine. The experimental concept is for fracturing to be initiated at an injection well and continue until it intersects a production well approximately 10 meters away. Initial step-pressure flow testing of the fracture are to be performed to describe pressure-aperture-flow relationships. The flow field between the injector and producer boreholes will be characterized using a series of forced gradient dipole tracer tests. A number of fracture characterization models have been used to assist in the design of the tracer tests. The tracer test program will use conservative, sorbing, and particulate tracers, as well as sampling for radon gas to describe the fracture surface area (i.e., potential heat transfer area), flow pathway distribution, and volume. Tracer concentration at the production well (i.e. break through curves) will be measured using a series of inline sensors, liquid sampling devices, filtering of the effluent, and the measuring of gas concentrations in the effluent. Tracer monitoring data will be compared against results from a collection of numerical simulators developed at U.S. national laboratories and universities for the purpose of validating these flow and transport models. Ultimately these same models will be used to predict the heat transfer characteristics of the fracture and will be compared to a thermal characterization field test where cold water will be injected at the injection well and the temperature will be measured at the production well. This paper discusses the early tracer transport model predictions and parameters sensitivity that affect the tracer breakthrough curves at the production well.

15 GEOTHERMAL ENERGY↗

Transport of colloidal particles in microscopic porous medium analogs with surface charge heterogeneity: experiments and fundamental role of single-bead deposition

Understanding colloid transport in subsurface environments is challenging due to complex interactions between colloids, ground water, and porous media over several length scales. Here, we study the transport of colloidal particles through bead-assembled microfluidic porous media analogs (PMAs) with surface charge heterogeneity. The pore-scale dynamics of colloidal particle deposition were measured, as well as the breakthrough curves (BTC) and retention profiles (RP) of deposited colloidal particles at the scale of the entire PMA. From pore-scale experiments, the maximum surface coverage (?max = 0.51) was measured directly, from which the surface blocking function and deposition coefficient (kpore = 3.56 s-1) were obtained. Using these pore-scale parameters, the transport of colloidal particles was modeled using a one-dimensional advection-dispersion equation under the assumption of irreversible adsorption between oppositely charged beads and colloids, showing good agreement with experimental data. This work presents a new approach to fabricate chemically heterogeneous porous media in a microfluidic device that enables direct measurements of pore-scale colloidal deposition. The approach allows a quantitative prediction of colloidal breakthrough and retention via coupling of direct measurements and an advection-dispersion-deposition model.

Guo, Yang↗