Search NASA⌕ Search

SEARCH · Search NASA

Results for “BuildingAmerica”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

46 records · Page 3

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

Greenbelt Homes Pilot Program: Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

In fall 2010, Greenbelt Homes, Inc. (GHI) a 1,566-home cooperative of circa 1930-1940 homes in Greenbelt, Maryland, undertook a multiyear pilot energy efficiency retrofit project. GHI established this pilot project as a basis for decision making for the rollout of a decade-long community-wide upgrade program that will incorporate energy-efficiency improvements to the building envelopes and mechanical equipment. The community upgrade is fully funded by the cooperative through its membership with no outside subsidies. This project thus presents a unique opportunity to evaluate and prioritize the wide range of benefits of high-performance retrofits based on member experience with and acceptance of the retrofit measures implemented during the pilot project. Addressing the complex interactions between benefits, tradeoffs, construction methods, project management implications, realistic upfront costs, financing, and other considerations provides a case study for energy retrofit projects to include high-performance technologies based on the long-term value to the homeowner.

Array↗

EcoVillage: A Net Zero Energy Ready Community - Ithaca Crawlspace

The U.S. Department of Energy's (DOE) Building America team, Consortium for Residential Buildings (CARB), is working with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This community-scale project consists of 40 housing units-15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. The community is pursuing certifications for DOE Zero Energy Ready Home, U.S. Green Building Council Leadership in Energy and Environmental Design Gold, and ENERGY STAR for the entire project. Additionally, seven of the 25 homes, along with the four-story apartment building and community center, are being constructed to the Passive House (PH) design standard.

Array↗

DOE Challenge Home Multifamily Development - Mixed Climate

The U.S. Department of Energys Zero Energy Ready Home (ZERH) recognition program builds upon the building science requirements of ENERGY STAR Certified Homes, Version 3 and best practices tested by the Building America research and demonstration program. Multifamily units (units in buildings with five or more apartments) comprise an increasingly important segment in the U.S. new housing market. Over the past 30 years, this segment has averaged 24% of residential building permits and since the recession in 2008 averages 34% of new residential building permits. This study analyses two multifamily homes, one townhouse and one apartment. The study looks to improve the efficiency of these homes to meet ENERGY STAR standards. Apartment - 2 bedroom apartment unit Townhome - 3 bedroom townhome unit

Array↗

Control Strategies to Reduce the Energy Consumption of Central Domestic Hot Water Systems

Domestic hot water (DHW) is the second-largest energy end use in U.S. buildings; it is exceeded only by space conditioning. In this study, the U.S. Department of Energy's Building America research team Advanced Research Integrated Energy Solutions installed and tested two types of recirculation controls in a pair of buildings to evaluate their energy savings potential. Demand control, temperature modulation (TM) controls, and their simultaneous operation were compared to the baseline case of constant recirculation.

Array↗

Community-Scale Attic Retrofit and Home Energy Upgrade Data Mining - Hot Dry Climate

Retrofitting is an essential element of any comprehensive strategy for improving residential energy efficiency. The residential retrofit market is still developing, and program managers must develop innovative strategies to increase uptake and promote economies of scale. Residential retrofitting remains a challenging proposition to sell to homeowners, because awareness levels are low and financial incentives are lacking. The U.S. Department of Energy's Building America research team, Alliance for Residential Building Innovation (ARBI), implemented a project to increase residential retrofits in Davis, California. The project used a neighborhood-focused strategy for implementation and a low-cost retrofit program that focused on upgraded attic insulation and duct sealing. ARBI worked with a community partner, the not-for-profit Cool Davis Initiative, as well as selected area contractors to implement a strategy that sought to capitalize on the strong local expertise of partners and the unique aspects of the Davis, California, community. Working with community partners also allowed ARBI to collect and analyze data about effective messaging tactics for community-based retrofit programs. ARBI expected this project, called Retrofit Your Attic, to achieve higher uptake than other retrofit projects, because it emphasized a low-cost, one-measure retrofit program. However, this was not the case. The program used a strategy that focused on attics-including air sealing, duct sealing, and attic insulation-as a low-cost entry for homeowners to complete home retrofits. The price was kept below $4,000 after incentives; both contractors in the program offered the same price. The program completed only five retrofits. Interestingly, none of those homeowners used the one-measure strategy. All five homeowners were concerned about cost, comfort, and energy savings and included additional measures in their retrofits. The low-cost, one-measure strategy did not increase the uptake among homeowners, even in a well-educated, affluent community such as Davis. This project has two primary components. One is to complete attic retrofits on a community scale in the hot-dry climate on Davis, CA. Sufficient data will be collected on these projects to include them in the BAFDR. Additionally, ARBI is working with contractors to obtain building and utility data from a large set of retrofit projects in CA (hot-dry). These projects are to be uploaded into the BAFDR.

affordable housing↗

Achieving Challenge Home in Affordable Housing in the Hot - Humid Climate

The Building America Partnership for Improved Residential Construction (BA-PIRC), one of the Building America research team leads, has partnered with two builders as they work through the Challenge Home certification process in one test home each. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity near Daytona, Florida and Manatee County Habitat for Humanity near Tampa, Florida. Both are affiliates of Habitat for Humanity International, a non-profit affordable housing organization. This research serves to identify viable technical pathways to meeting the CH criteria for other builders in the region. A further objective of this research is to identify gaps and barriers in the marketplace related to product availability, labor force capability, code issues, cost effectiveness, and business case issues that hinder or prevent broader adoption on a production scale. The builder partners participating in this cost-shared research are Southeast Volusia County Habitat for Humanity (SEVHFH) near Daytona, Florida and Manatee County Habitat for Humanity (MCHFH) near Tampa, Florida. Both are affiliates of Habitat for Humanity International (HFHI), a nonprofit affordable housing organization. Manatee Co Habitat for Humanity Challenge home - Ellenton, FL 34222 S. Sarasota Challenge Home - Sarasota, FL Southeast Volusia co Habitat for Humanity's Challenge Home - Edgewater, FL 32141 Several iterations of home, Challenge Home as built, Challenge Home without solar, and Challenge Home configured to just meet Florida Code. All houses redone in BEOpt 2.1.0.2

affordable housing↗

Retrofitting a 1960s Split-Level Cold-Climate Home

The U.S. Department of Energy Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders, a previous CARB partner and builder of the Performance House (DOE 2013) and the owners of a 1960s split-level home in Westport, Connecticut, to evaluate and implement a cost-effective solution package that met the requirements of 30% source energy savings compared to the pre-retrofit performance. This home had already been updated aesthetically (kitchen and bathrooms), so the owners wanted the energy-efficiency measures to be as non-disruptive to the interior finishes as possible.

airtightness↗

NorthernStar Zero Energy Ready Homes

This is a repository for all NorthernSTAR Zero Energy Ready certified homes. Amaris Homes Model Home - St. Paul, MN 55110 Description: Model home completed September 2013 The DOE Zero Energy Ready Home Case Study looks to study and eventually design zero net energy homes in cold weather climates. These zero net energy homes are referred to as challenge homes. For this challenge home, Amaris Homes is working with the DOE in St. Paul, Minnesota. The household located at MN 55110 acts as the Amaris Challenge Home Test. The resources include technical drawings including siding, roofing and Windows. Christian Builders Challenge Home - House Count: 1 - Otsego, MN 55374 Need pictures from builder; This home actually narrowly missed certification under DOE Net Zero Energy Ready Homes. Need building plans and project summary from builder. DESIGN AND STRUCTURE - Amaris Homes - House Count: 7 Stillwater, MN 55082; Vadnais Heights, MN 55127; Bloomington, MN 55437; Apple Valley, MN 55124; White Bear Lake, MN 55110; Mounds View, MN 55112; Midland, MI 48642; DOE Zero Energy Ready Homes

Array↗

Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate

The Building America Partnership for Improved Residential Construction, formerly the Building America Industrialized Housing Partnership, has worked with several community-scale builders within the hot-humid climate zone to improve performance of production-, or community-scale, housing. Tommy Williams Homes (Gainesville, Florida), LifeStyle Homes (Melbourne, Florida), and Habitat for Humanity (various locations, Florida) have all been continuous partners of the Building America Program. The activities of these partners, described in this report, achieved the Building America goal of 30% whole-house source energy savings using packages adopted at the community scale. For new homes, the reference case is the B10 Benchmark, aligned with 2009 building codes.

affordable housing↗