Search NASA⌕ Search

SEARCH · Search NASA

Results for “CCDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Comparison of the Proton-Induced Dark Current and Charge Transfer Efficiency Responses of N- and P-Channel CCDs

The proton-induced CTE behavior for the Lawrence Berkeley National Laboratory (LBNL) p-CCD (being developed for the Supernovae Acceleration Project (SNAP) and Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) n-CCDs were compared using 55Fe, EPER and FPR techniques. CTE performance of the p-CCD is about an order of magnitude better after a 63 MeV fluence of 2.5 x 10(sup 9)/sq cm, which is equivalent to 2.5 years in the shielded HST orbit. Notched n- and p-CCDs yielded factor of two improvement in CTE performance as compared to their un-notched versions. The introduction rate of hot pixels was greater in p-CCD as compared to n-CCD, and also greater in notched than un-notched devices.

Marshall, Cheryl↗

Chemical Thinning Process for Fabricating UV-Imaging CCDs

The thinning stage of the postfabrication process reported in the immediately preceding article is notable in its own right. Although the thinning process was described in the preceding article as part of an overall process of fabrication of a supported charge-coupled device (CCD), it is more generally applicable to both free-standing and supported devices that have been fabricated in die and wafer formats. Like the thermocompression bonding process described in the preceding article, the thinning process is compatible with CCD-fabrication processes, as well as postfabrication processes that enhance the response of CCDs to ultraviolet (UV) light, including the delta-doping process. CCDs that are thinned by this process and then delta-doped exhibit high quantum efficiencies that are stable with time and with exposure to the environment.

Jones, TOdd↗

Delta-Doped CCDs for Enhanced UV Performance

Thin, backside-illuminated CCds are modified by growing a delta-doped silicon layer on the back surface using molecular beam epitaxy. Delta-doped CCDs exhibit stable and uniform 100 percent internal quantum efficiency. The process consists of growth of an epitaxial silicon layer on a fully-processed commercial CCd die in which 30 percent of a monolayer of boron atoms are incorporated into the lattice nominally in a single atomic layer. Long term stability was tested and showed no degradation of the device quantum efficiency over sixteen months.

silicon↗

DarkNESS: Characterization of Space Multi-Chip Module Skipper-CCDs and Readout Electronics

The DarkNESS mission has the goal of deploying a 6U CubeSat fitted with an array of skipper-CCDs in Low Earth Orbit (~400 km). The new instrument will take measurements of diffuse x-rays and look for signatures of dark matter decay in the spectrum. DarkNESS will also perform a direct search for strongly interacting sub-GeV dark matter in regions of the parameter space not accessible to ground based experiments [1]. Skipper-CCDs allow for low-noise astronomical observations which can extend the discovery reach for direct dark matter search experiments. This paper will discuss the laboratory characterization of the two key components of the scientific payload: the space Multi-Chip Module (sMCM), and their readout electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

Electron-Induced Displacement Damage Effects in CCDs

We compare differences in parametric degradation for CCDs irradiated to the same displacement damage dose with 10-MeV and 50-MeV electrons. Charge transfer efficiency degradation was observed to not scale with NIEL for small signals.

Juno Mission↗

Sandbox CCDs

Seven new CCDs are presented. The devices will be used in a variety of applications ranging

Sandbox↗

Low-Energy Electron Detection with Delta-Doped CCDs

In this paper, we will briefly discuss delta-doped CCDs and their application of low-energy electron detection. We show that modification of the surface this way can greatly improve sensitivity to low energy electrons.

electron↗

Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab

Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the ~MeV mass range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The physics potential of a reactor neutrino experiment with Skipper CCDs: Measuring the weak mixing angle

We analyze in detail the physics potential of an experiment like the one recently proposed by the vIOLETA collaboration: a kilogram-scale Skipper CCD detector deployed 12 meters away from a commercial nuclear reactor core. This experiment would be able to detect coherent elastic neutrino nucleus scattering from reactor neutrinos, capitalizing on the exceptionally low ionization energy threshold of Skipper CCDs. To estimate the physics reach, we elect the measurement of the weak mixing angle as a case study. We choose a realistic benchmark experimental setup and perform variations on this benchmark to understand the role of quenching factor and its systematic uncertainties, background rate and spectral shape, total exposure, and reactor antineutrino flux uncertainty. We take full advantage of the reactor flux measurement of the Daya Bay collaboration to perform a data driven analysis which is, up to a certain extent, independent of the theoretical un- certainties on the reactor antineutrino flux. We show that, under reasonable assumptions, this experimental setup may provide a competitive measurement of the weak mixing angle at few MeV scale with neutrino-nucleus scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studying single-electron traps in newly fabricated Skipper-CCDs for the Oscura experiment using the pocket-pumping technique

Understanding and characterizing very low-energy (⁠ ∼eV) background sources is a must in rare-event searches. Oscura, an experiment aiming to probe electron recoils from sub-GeV dark matter using a 10 kg skipper-CCD detector, has recently fabricated its first two batches of sensors. In this work, we present the characterization of defects/contaminants identified in the buried-channel region of these newly fabricated skipper-CCDs. These defects/contaminants produce deferred charge from trap emission in the images next to particle tracks, which can be spatially resolved due to the sub-electron resolution achieved with these sensors. Using the trap-pumping technique, we measured the energy and cross section associated with these traps in three Oscura prototype sensors from different fabrication batches which underwent different gettering methods during fabrication. Results suggest that the type of defects/contaminants is more closely linked to the fabrication batch rather than to the gettering method used. The exposure-dependent single-electron rate (SER) of one of these sensors was measured ∼100 m underground, yielding (1.8±0.3)×10−3e−/pix/day at 131 K. The impact of the identified traps on the measured exposure-dependent SER is evaluated via a Monte Carlo simulation. Results suggest that the exposure-dependent SER of Oscura prototype sensors would be lower in lower background environments as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skipper CCDs for the search of a daily modulation of Dark Matter signal in the DMSQUARE experiment

The Dark Matter Daily Modulation experiment (DMSQUARE) seeks for dark matter interactions with a Skipper CCD. It is currently running at surface level in Bariloche, Argentina, and will be moved to a shallow underground site at Sierra Grande, Argentina in November 2021. The low threshold achieved by Skipper CCDs allows to search for electron recoil events with an ionization energy down to 1.2 eV. In order to extract a potential dark matter signal from noise at the single electron level, we propose to search for a diurnal modulation of events, resulting from the potential interaction of the dark matter wind with the particles in the Earth. Depending on the model, mass and cross-section, this modulation can be maximum at 40deg of latitude in the Southern Hemisphere, where DMSQUARE is operated. In this article we present the experiment, report preliminary results with a prototype Skipper CCD taking data at surface level and comment on future prospects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Activity Tritium Detection in CCDs Using Deep Learning Techniques

Here, this study explores the use of charge-coupled devices (CCDs) for detecting low-energy beta particles from tritium decay - a critical signal for nuclear safety, nuclear nonproliferation, and environmental monitoring. We employ a dual approach utilizing both measured CCD data and detailed Geant4 simulations. Our analysis compares classical techniques with advanced deep learning methods, including convolutional neural networks (CNNs), autoencoders trained exclusively on tritium data, and preliminary studies on boosted decision trees (BDTs). The CNN, trained on mixed signal/background datasets, demonstrates superior classification performance, while the autoencoder shows the potential of unsupervised, background-agnostic strategies when background characteristics are poorly defined. These results highlight the excellent sensitivity achievable thanks to the background rejection made possible by information-rich CCD data, paving the way for improved portable tritium monitoring.

Autoencoder↗

Characterization of skipper CCDs for cosmological applications

We characterize the response of a novel 250 µm thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable, single-electron resolution with readout noise &sigma; 0.18 e - rms/pix from 400 non-destructive measurements of the charge in each pixel. We verify that the gain derived from photon transfer curve measurements agrees with the gain calculated from the quantized charge of individual electrons to within < 1%. We also perform relative quantum efficiency measurements and demonstrate high relative quantum efficiency at optical/near- infrared wavelengths, as is expected for a thick, fully depleted detector. Finally, we demonstrate the ability to perform multiple non-destructive measurements and achieve sub-electron readout noise over configurable sub- regions of the detector. This work is the first step toward demonstrating the utility of Skipper CCDs for future astronomical and cosmological applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PID Temperature Controller Autotuning for Skipper-CCDs

Proportional-integral-derivative (PID) temperature control of Skipper-CCDs is important for dark matter direct-detection experiments, e.g., SENSEI@MINOS. The project goal is to create an autotuned PID controller in Python to replace expensive Lake Shore temperature controllers.

Jones, Evan↗

Oscura: Dark Matter search with 10 kg of skipper-CCDs

The electron-counting capability of the skipper-CCDs has enabled world leading searches for low mass DM-electron scattering in experiments with less than 100 g active mass (SENSEI and DAMIC-M). Oscura is the ongoing effort to develop a 10 kg skipper-CCD experiment for dark matter search. In this talk, I will discuss the current status and plans for the Oscura experiment, including the performance of the prototype sensors and the plans for early science.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Astronomical Spectroscopy with Skipper CCDs: First Results from a Skipper CCD Focal Plane Prototype at SIFS

We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel, fully-depleted, $p$-channel devices that have been thinned to $\sim$250 $\mu$m, backside processed, and treated with an anti-reflective coating. These Skipper CCDs were configured for astronomical spectroscopy, i.e., a single-sample readout noise $< 4.3$\,e$^-$\,rms/pixel, the ability to achieve multi-sample readout noise $\ll 1\,$e$^-$\,rms/pix, full-well capacities $\sim$40,000--65,000 e$^-$, low dark current and charge transfer inefficiency ($\sim 2$ $\times$ $10^{-4}$ e$^-$/pixel/s and 3.44 $\times$ $10^{-7}$, respectively), and an absolute quantum efficiency of $\gtrsim 80\%$ between 450\,nm and 980\,nm ($\gtrsim 90\%$ between 600\,nm and 900\,nm). We optimize the readout sequence timing to achieve sub-electron noise ($\sim 0.5$\,e$^-$\,rms/pix) and photon-counting ($\sim 0.22$\,e$^-$\,rms/pix) readout noise over an area of 2k $\times$ 4k and 110 $\times$ 4k pixels, respectively in a readout time of $\lesssim 17$min. We observed two Lyman-$\alpha$ emitting quasars (HB89\,1159$+$123 and QSO\,J1621$–$0042) at redshift $z \sim 3.5$, two moderate redshift galaxy clusters (CL\,J1001$+$0220 and SPT-CL\,J2040$-$4451), an emission line galaxy at $z = 0.3239$, a candidate member star of the Bo\"{o}tes~II ultra-faint dwarf galaxy, and five CALSPEC spectrophotometric standard stars (HD074000, HD60753, HD106252, HD101452, HD200654). We present charge-quantized, photon-counting observation of the quasar HB89\,1159$+$123 and show the detector sensitivity increase for faint spectral features. We demonstrate signal-to-noise performance improvement for SIFS for observations in the low-background, readout-noise-dominated regime. We outline preliminary scientific studies that will leverage the SIFS-Skipper CCD data to derive new cosmological measurements in the context of dark matter and galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗