Water-cooled Reactor Cavity Cooling System Flow Analysis

A research team at University of Wisconsin - Madison designed and constructed a 1/4 scaled experimental facility to study natural circulation cooling in a water based reactor cavity cooling system (WRCCS) for decay heat removal in an advanced high temperature reactor. The facility is capable of natural circulation operation scaled for simulated decay heat removal (up to 45 kW input power, which is equivalent to 1.70 MW at full scale) and pressurized up to 2 bar pressure. The WRCCS facility has been used to study natural circulation flow behavior from transients due to evaporation of the water inventory from decay heat removal. The natural circulation flow is observed to be oscillatory with the mean flow increasing as the pressure head in the system drops due to evaporation of the water inventory during two-phase operation. A first principles model was developed to understand the behavioral limits and trends. Through the use of void fraction measurements and the model, we find that the mass flow rate in the system increases due to small increases in the time-averaged void fraction over the course of a four-hour boil-off experiment. This increase in void fraction causes an increase in the buoyancy head and mass flow. The model also determines the operational limits on the mass flow rate under two-phase operation that can be verified with extended tests in the WRCCS facility. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Results from a scaled reactor cavity cooling system with water at steady state

We present a summary of steady-state experiments performed with a scaled, water-cooled Reactor Cavity Cooling System (RCCS) at the Univ. of Wisconsin - Madison. The RCCS concept is used for passive decay heat removal in the Next Generation Nuclear Plant (NGNP) design and was based on open literature of the GA-MHTGR, HTR-10 and AVR reactor. The RCCS is a 1/4 scale model of the full scale prototype system, with a 7.6 m structure housing, a 5 m tall test section, and 1,200 liter water storage tank. Radiant heaters impose a heat flux onto a three riser tube test section, representing a 5 deg. radial sector of the actual 360 deg. RCCS design. The maximum heat flux and power levels are 25 kW/m{sup 2} and 42.5 kW, and can be configured for variable, axial, or radial power profiles to simulate prototypic conditions. Experimental results yielded measurements of local surface temperatures, internal water temperatures, volumetric flow rates, and pressure drop along the test section and into the water storage tank. The majority of the tests achieved a steady state condition while remaining single-phase. A selected number of experiments were allowed to reach saturation and subsequently two-phase flow. RELAP5 simulations with the experimental data have been refined during test facility development and separate effects validation of the experimental facility. This test series represents the completion of our steady-state testing, with future experiments investigating normal and off-normal accident scenarios with two-phase flow effects. The ultimate goal of the project is to combine experimental data from UW - Madison, UI, ANL, and Texas A and M, with system model simulations to ascertain the feasibility of the RCCS as a successful long-term heat removal system during accident scenarios for the NGNP. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CFD analyses of natural circulation in the air-cooled reactor cavity cooling system

The Natural Convection Shutdown Heat Removal Test Facility (NSTF) is currently being built at Argonne National Laboratory, to evaluate the feasibility of the passive Reactor Cavity Cooling System (RCCS) for Next Generation Nuclear Plant (NGNP). CFD simulations have been applied to evaluate the NSTF and NGNP RCCS designs. However, previous simulations found that convergence was very difficult to achieve in simulating the complex natural circulation. To resolve the convergence issue and increase the confidence of the CFD simulation results, additional CFD simulations were conducted using a more detailed mesh and a different solution scheme. It is found that, with the use of coupled flow and coupled energy models, the convergence can be greatly improved. Furthermore, the effects of convection in the cavity and the effects of the uncertainty in solid surface emissivity are also investigated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Model validation using CFD-grade experimental database for NGNP Reactor Cavity Cooling Systems with water and air

This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has been developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintain similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat transfer in a fissioning uranium plasma reactor cavity

Two schemes are investigated by which a fission-heated uranium plasma located in the central cavity of a test reactor could be insulated to keep its temperature above condensation in a neutron flux of 10 to the 15th power neutrons/(sq cm)(sec) or less. The first scheme was to use a mirrored cavity wall to reflect the thermal radiation back into the plasma. The second scheme was to seed the transpirational cavity wall coolant so as to make it opaque to thermal radiation, thus insulating the hot plasma from the cold wall. The analysis showed that a mirrored cavity wall must have a reflectivity of over 95 percent or that seeded argon must be used as the wall coolant to give an acceptable operating margin above fuel condensation conditions.

Kascak, A. F.↗

Experimental analysis of gas dynamics in the reactor cavity section of a High-Temperature Gas-Cooled Reactor during an accident scenario

Here, this study investigates the behavior of a High-Temperature Gas-Cooled Reactor (HTGR) during a break of the helium pressure boundary event. Understanding the gas dynamics that occur during a break could help develop safety systems that reduce the probability of air entering the reactor core. To achieve this objective, experimental studies were conducted in a scaled-down HTGR experimental facility to provide information on the air-helium gas mixture within the confinement building and the impact of the ventilation system on the helium/air gas concentration following the depressurization event. The study evaluated different configurations, including active ventilation time scales, break sizes, and locations. The analysis of the active ventilation time revealed that a ventilation time of 22 seconds produced positive results, and smaller break sizes resulted in longer depressurization times, which improved the ventilation process. The orientation and elevation of the breaks had little effect on the oxygen concentration in the cavity but did impact the gas velocities.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Electromagnetic plasma models for microwave plasma cavity reactors

A procedure used to design cavity applicators that efficiently produce cylindrical and disk microwave discharges is reviewed. In contrast to most microwave applicators these cavities utilize single mode excitation of the plasma. This method of excitation has the advantage of providing efficient coupling (zero reflected power) to the plasma over a wide range of discharge loading conditions while also allowing, if desired, electric feedback control of the heating process. The design procedure is generalized to any lossy dielectric. Experimental and theoretical research required to further understand microwave discharges is also discussed.

Frasch, L.↗

New Measurements and Calculations to Characterize the Caliban Pulsed Reactor Cavity Neutron Spectrum by the Foil Activation Method

Caliban is a cylindrical metallic core reactor mainly composed of uranium 235. It is operated by the Criticality and Neutron Science Research Laboratory located at the French Atomic Energy Commission research center in Valduc. As with other fast burst reactors, Caliban is used extensively for determining the responses of electronic parts or other objects and materials to neutron-induced displacements. Therefore, Caliban's irradiation characteristics, and especially its central cavity neutron spectrum, have to be very accurately evaluated. The foil activation method has been used in the past by the Criticality and Neutron Science Research Laboratory to evaluate the neutron spectrum of the different facilities it operated, and in particular to characterize the Caliban cavity spectrum. In order to strengthen and to improve our knowledge of the Caliban cavity neutron spectrum and to reduce the uncertainties associated with the available evaluations, new measurements have been performed on the reactor and interpreted by the foil activation method. A sensor set has been selected to sample adequately the studied spectrum. Experimental measured reaction rates have been compared to the results from UMG spectrum unfolding software and to values obtained with the activation code Fispact. Experimental and simulation results are overall in good agreement, although gaps exist for some sensors. UMG software has also been used to rebuild the Caliban cavity neutron spectrum from activation measurements. For this purpose, a default spectrum is needed, and one has been calculated with the Monte-Carlo transport code Tripoli 4 using the benchmarked Caliban description. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Beryllium reflected cavity reactor for UF6 critical experiments

Experiments and theoretical studies are being conducted for NASA on critical assemblies with one-meter diam by one-meter long low-density cores surrounded by a thick beryllium reflector. These assemblies make extensive use of existing nuclear propulsion reactor components, facilities, and instrumentation. Due to excessive porosity in the reflector, the initial critical mass was 19 kg U(93.2). Addition of a 17-cm-thick by 89-cm-diam beryllium flux trap in the cavity reduced the critical mass to 7 kg when all the uranium was in the zone just outside the flux trap. A mockup aluminum UF6 container was placed inside the flux trap and fueled with uranium-graphite elements. Fission distributions and reactivity worths of fuel and structural materials are available. These results will be used to guide the design of a prototype plasma core reactor which will test energy removal by optical radiation.

Jarvis, G. A.↗

Radiation Damage In Reactor Cavity Concrete

License renewal up to 60 years and the possibility of subsequent license renewal to 80 years has established a renewed focus on long-term aging of nuclear generating stations materials, and recently, on concrete. Large irreplaceable sections of most nuclear generating stations include concrete. The Expanded Materials Degradation Analysis (EMDA), jointly performed by the Department of Energy, the Nuclear Regulatory Commission and Industry, identified the urgent need to develop a consistent knowledge base on irradiation effects in concrete. Much of the historical mechanical performance data of irradiated concrete does not accurately reflect typical radiation conditions in NPPs or conditions out to 60 or 80 years of radiation exposure. To address these potential gaps in the knowledge base, The Electric Power Research Institute and Oak Ridge National Laboratory are working to disposition radiation damage as a degradation mechanism. This paper outlines the research program within this pathway including: (i) defining the upper bound of the neutron and gamma dose levels expected in the biological shield concrete for extended operation (80 years of operation and beyond), (ii) determining the effects of neutron and gamma irradiation as well as extended time at temperature on concrete, (iii) evaluating opportunities to irradiate prototypical concrete under accelerated neutron and gamma dose levels to establish a conservative bound and share data obtained from different flux, temperature, and fluence levels, (iv) evaluating opportunities to harvest and test irradiated concrete from international NPPs, (v) developing cooperative test programs to improve confidence in the results from the various concretes and research reactors, (vi) furthering the understanding of the effects of radiation on concrete (see companion paper) and (vii) establishing an international collaborative research and information exchange effort to leverage capabilities and knowledge.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectral Analysis of LDV Measurements inside of the TAMU Air-Cooled Reactor Cavity Cooling System - 18688

Spectral analysis was applied to the LDV measurements inside of the TAMU air-cooled RCCS facility at two different locations to both evaluate the feasibility of spectral methods for this experiment and gain a first insight into the flow behavior using a Fourier representation. Application of the wavelet transform showed that there are patterns in the flow signified by repeating frequencies and flow structures. Although the sampling rate of 7.92 Hz at the data point centered at the bottom center of riser 4 was lower than the higher frequency sampling rate of 57.92 Hz at the top data point of the upper plenum, the wavelet transforms of the higher frequency data point showed that the dominant frequencies were bounded within 4 Hz. Application of wavelet analysis is limited by the size of the interrogation window but may be modified according to the frequency range of interest by adjusting the size of the time width for the undilated Morlet mother wavelet. Spectral analysis can be applied to future experiments to understand uncharacterized flow behavior such as flow reversal inside of the upper plenum and for benchmarking future CFD simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗