Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compressed air operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Status Report on FY2022 Model Development within the Integrated Energy Systems HYBRID Repository

This publication details newly created energy storage models developed within the HYBRID Modelica repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), liquid air energy storage (LAES), and compressed air energy storage (CAES) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ability of Particulate Matter Index to describe sooting tendency of various gasoline formulations in a stratified-charge spark-ignition engine

This study investigates the ability of Particulate Matter Index (PMI) to describe the sooting behavior of various gasoline formulations in a stratified-charge (SC) spark-ignition engine. Specifically, the engine was operated at 2000 rpm with an intake pressure of 130 kPa where soot formation is known to primarily occur in the bulk gases. Exhaust soot emissions were measured for nine test fuels at various exhaust gas recirculation levels. A comparison between measured soot levels and PMI shows that PMI is a relatively poor predictor of the sooting tendency of the tested fuels under lean SC combustion. Among the fuels, three fuels, namely the diisobutylene blend, High Olefin, and E30 fuels exhibit measured soot behavior opposite of that predicted by PMI. Optical diagnostics were utilized to further investigate the in-cylinder phenomena for these three fuels. Analysis of natural luminosity and diffused back-illumination extinction imaging suggests that fuel-induced differences in the amount of soot formed are responsible for a majority of the discrepancy in measured versus predicted sooting tendency. Fuel-induced differences in soot oxidation and spray development seem to play minor roles. Because the combustion and air-fuel mixing processes for lean SC combustion are different from conventional stoichiometric operation it is hypothesized that the PMI correlation needs to be modified to account for differences in stoichiometric air-fuel ratio and level of oxygenation between fuels. Furthermore, the role of fuel volatility in PMI possibly needs to be de-emphasized for SC operation with fuel injection into compression-heated gases.

42 ENGINEERING↗

THESEUS: A techno-economic design, integration and downselection framework for energy storage

Optimal selection of energy storage technologies is critical to ensure reliable integration of intermittent and often uncertain renewable energy in electricity grids. The consideration of a diverse set of energy storage technologies is required for a more sustainable deployment of energy storage. We present THESEUS (TecHno-Economic framework for Systematic Energy storage Utilization and downSelection), which is a comprehensive framework for the optimal selection, design and operation of energy storage systems. THESEUS includes rigorous models of major energy storage technologies at different maturity levels, such as thermal storage using phase-change materials or molten salt, cryogenic storage, mechanical storage in the form of compressed air and pumped hydro storage, chemical storage using hydrogen, and electrochemical storage in the form of lithium-ion, sodium sulfur and vanadium flow batteries. An illustrative case study on state-wide prospective energy storage shows that storage integration with fossil power plants could reduce the cost of meeting the grid energy demand by 20%, with mechanical storage as the best suited technology. Although high-temperature thermal storage has low storage efficiency, it is optimal for integration with renewable energy plants. In addition, Li-ion batteries are optimal for high ramping but low storage duration requirements. Furthermore, such insights can enable the deployment of both existing and emerging energy storage technologies to facilitate a smooth transition to a clean energy future.

25 ENERGY STORAGE↗

Material properties of aqueous potassium acetate solutions for use in liquid desiccant air conditioning

We present thermophysical properties of aqueous potassium acetate solutions relevant to their application as a liquid desiccant in air-conditioning systems. Liquid desiccant air conditioners could provide up to 80% energy savings compared to high-efficiency vapor compression air conditioners. However, the commonly used liquid desiccants, particularly chloride salt solutions, are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Potassium acetate has been identified as a less corrosive alternative, potentially enabling broader material compatibility in LDAC components. In this study we systematically measured and modelled key thermophysical properties of KAc solutions density, vapor pressure, viscosity, specific heat capacity, phase behavior, and diffusion coefficient across a range of concentrations (10 - 70wt%) and temperatures. For instance, KAc exhibits a vapor pressure of 3.1 kPa at 50wt% and 40degrees C, demonstrating dehumidification capability comparable to chloride salts. By providing an extended dataset and associated models, this work advances the understanding needed to design energy-efficient, corrosion mitigating LDAC system.

36 MATERIALS SCIENCE↗

LIQUID AIR COMBINED CYCLE

Hybrid integration of thermal energy storage with gas turbines can provide compact, cost-effective, long-duration energy storage while reducing the fuel consumption of dispatchable resources needed for the reliability of renewable dominant electric grids. The Liquid Air Combined Cycle™ (LACC) is a hybrid energy storage system using cryogenic liquid air as an energy storage medium and gas turbine exhaust heat to extract stored energy. The storage tank is charged using liquefaction processes employing electric motor-driven compressors to pressurize the air, heat exchangers to reject heat of compression, and expanders to reduce the temperature and liquefy the air. Proven cryogenic refrigeration processes can be selected based on capital cost (per kg/s of liquid air produced), efficiency (kJ per kg of air produced), and operating factors including startup speed and load following capability. This paper presents results of studies undertaken for the U.S. Department of Energy to evaluate cost and performance tradeoffs for charge and discharge cycle components, optimize charge and discharge cycles, and assess the techno-economic potential of LACC technology.

Conlon, William↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Follow-On Status Report on FY2022 Model Development within the Integrated Energy Systems Hybrid Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), compressed air energy storage (CAES), and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RODeO (Revenue Operation and Device Optimization Model) [SWR 20-67]

The Revenue, Operation, and Device Optimization (RODeO) model explores optimal system design and operation considering different levels of grid integration, equipment cost, operating limitations, financing, and credits and incentives. RODeO is a price-taker model formulated as a mixed-integer linear programming (MILP) model in the GAMS modeling platform. The objective is to maximizes the net revenue for a collection of equipment at a given site. The equipment includes generators (e.g., gas turbine, steam turbine, solar, wind, hydro, fuel cells, etc.), storage systems (batteries, pumped hydro, gas-fired compressed air energy storage, long-duration systems, hydrogen), and flexible loads (e.g., electric vehicles, electrolyzers, flexible building loads). The input data required by RODeO can be classified into three bins: 1) utility service data, which refers to retail utility rate information (meter cost, energy and demand charges), 2) electricity market data, which include energy and reserve prices, 3) other inputs, which refer to additional electrical demand, product output demand, technological assumptions, financial properties, and operational parameters.

Guerra Fernandez, Omar Jose↗

Corrosion of Metal Alloys in Potassium Acetate Solutions for Liquid Desiccant Dehumidification and Air Conditioning

For commercial buildings, liquid desiccant air conditioners (LDACs) could provide up to 80% energy savings compared to high-efficiency vapor compression AC, but commonly utilized liquid desiccants are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Less corrosive alternatives are sought. Here, potassium acetate solutions are investigated as less-corrosive alternatives to the chloride salt solutions that are typically used in LDAC systems. Corrosion evaluations for a Cu alloy (C12200) and two Al alloys (Al3003 and Al1100) in both potassium acetate and chloride salt solutions are presented. We show that yearly corrosion rates are lower in potassium acetate solutions by up to three orders of magnitude. Active corrosion behavior is largely absent in potassium acetate solutions but is present in chloride salt solutions. Furthermore, solid corrosion products are observed in chloride salt solutions. Thus, we conclude that potassium acetate is a promising candidate as a less corrosive alternative liquid desiccant for LDAC systems with metallic components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical study of advanced compression ignition and combustion in a gasoline direct injection engine

Multi-mode combustion strategies may provide a considerable thermal efficiency improvement targeted at part-load operating conditions for light-duty spark-ignition (SI) engines. The extension from boosted SI mode at high loads to advanced compression ignition (ACI) mode at low loads can be achieved by increasing compression ratio and utilizing intake air heating. In order to enable an accurate control of intake charge condition for ACI control and rapid mode-switches, it is essential to gain fundamental insight into the autoignition process with regard to thermal and fuel-air mixture stratification in the combustion chamber. In this work, a computational fluid dynamics (CFD) study is carried out to reveal some degrees of correlation between the mixture and thermal stratifications induced by the cylinder wall temperature and combustion-phasing across varying engine load conditions. The computational analysis begins with a calibrated simulation setup best matching the engine experiments, and subsequently evaluates the baseline setup for an extended range of engine load conditions for two excess-air ratio cases. The present study emphasizes the dominance of thermal stratifications for autoignition process due to wall temperature effects depending on the engine load conditions of interest. In addition, this study also aims to provide insight into the impact of mixture stratification on cyclic variability, especially at colder wall engine conditions (e.g., cold start). Observations herein provide highlight of the propensity of autoignition in correlation with mixture reactivity space.

Advanced Compression Ignition (ACI) engine↗

MEASUR - Manufacturing Energy Assessment Software for Utility Reduction

MEASUR your energy savings with the free DOE MEASUR software The Department of Energy (DOE), with Oak Ridge National Laboratory (ORNL), released version 1.0 of their energy efficiency software tool MEASUR (Manufacturing Energy Assessment Software for Utility Reduction). MEASUR has been available for several years as a beta version, being tested by industry experts and real users, and will continue to be updated and improved in the coming years. It is an integrated suite of tools to aid manufacturers in improving the efficiency of energy systems and equipment within a plant, including motors, pumps, fans, process heating, steam, and compressed air. Additionally, there are modules for wastewater energy analysis and to help perform energy treasure hunts. Several calculators are also included, allowing users to independently perform smaller calculations and analyses (such as estimating pump head, performing a fan traverse analysis, estimating waste heat recovery potential, and cataloging compressed air leaks). The MEASUR modules are based on previous DOE software tools that have been used by industry since the early 2000s (such as MotorMaster, AirMaster+, PSAT, PHAST, and FSAT). The original tools only ran on Windows operating systems, and by Windows 10, most of them were inoperable. DOE started their energy efficiency software tool revitalization effort in 2016, first with PSAT (for pumps), then began to integrate the other tools and expand their functionality and utility. The new MEASUR suite provides an extensively more user-friendly, modern, and versatile set of tools. All the assessment modules and most of the calculators have several visual components and graphs and detailed help text for every user input. To help reach international users, the tool utilizes Google translate and users can easily change unit systems, even converting existing user inputs if desired. The assessment files can be organized within the internal file system and easily shared to other users, regardless of their operating system. The entire suite is free, open-source, and can be downloaded on Windows, Mac, or Linux operating systems.

Accawi, Gina [Oak Ridge National Lab. (ORNL), Oak ↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras: Preprint

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Testing of Crystalline Silicotitanate to Support Tank-Side Cesium Removal System Operations - 20458

The direct feed of waste from the Hanford tank farms to the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant requires an intermediate treatment step that prepares the waste for vitrification. Washington River Protection Solutions (WRPS) selected a near-tank treatment system known as the Tank-Side Cesium Removal (TSCR) system to perform the required intermediate treatment functions. The approach in the TSCR system is to filter waste supernatant with a sintered metal dead-end filter and then use a series of ion exchange columns to remove cesium; this system has several similarities to the Tank Closure Cesium Removal system that has been deployed on the Savannah River Site. The ion exchange media proposed for use is crystalline silicotitanate (CST), which is a non-elutable media with a high affinity for cesium. Because the media is non-elutable, loaded columns will be blown down with compressed air, moved into interim storage, and replaced with new columns when cesium capacity is reached. The assumed extent and rate of drying that could be achieved in the TSCR column geometry lacked confirmation by experimental data. In addition, once the columns are loaded with cesium, they generate flammable gases (primarily hydrogen) via radiolysis acting on any resident liquids, i.e., moisture, remaining in the media bed. An assessment of available information on CST concluded that gas generation data that bounds expected operational conditions were needed to support the TSCR system safety basis and planned operations. Working with WRPS, Pacific Northwest National Laboratory (PNNL) designed and conducted testing with CST media to address the need for (a) representative in-column drying data, and (b) bounding flammable gas generation data. Drying testing was performed using a full-height column with a diameter of approximately 2 inches with injected air at temperatures of 18 deg. C and 30 deg. C. Gas generation testing was conducted in an engineered bunker that allowed simultaneous irradiation of up to eight samples at a time. These two experimental approaches used at PNNL for the CST testing are summarized and the major outcomes are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-GWP Refrigerants Status and Outlook

Refrigeration - including air conditioning (AC) – contributes substantially to the modern life of the 21st century and its economy. The food cold chain, air conditioning, healthcare and energy are examples of sectors for which refrigeration is indispensable. About 5 billion refrigeration systems – of different types and sizes– operate worldwide in different applications [1]. The dominant share of equipment providing refrigeration operate on the vapor-compression-cycle principle and use fluorocarbon refrigerants. Concerns about the environmental safety have become the driving force for refrigerant changes within the last 35 years. The phased-out schedule of stratospheric-ozone-depleting fluids was first formulated by the Montreal Protocol (MP) in 1987 and was made more stringent during the follow-up international meetings [2]. The affected chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigerants were largely replaced by hydrofluorocarbons (HFCs).The 2016 Kigali Amendment to the MP [3] responses to the concerns about the Earth climate change. The refrigeration and AC sectors are attributed with about 7.8 % of global greenhouse gas emissions [4]. This contribution comes in the form of direct effect, which is related to refrigerant emissions from refrigeration systems (37 %), and in the form of indirect effect, which is related to CO2 emissions from fossil fuel power plants producing electricity to power refrigeration systems (63 %) [4]. The Kigali Amendment aims at reducing the direct effect. The effect a given molecule has on the climate change is quantified in a simplified manner by its Global Warming Potential (GWP), a relative index referencing the effect produced to that of the same mass of carbon dioxide released to the atmosphere. By definition, GWP of carbon dioxide is equal to one.While HFC refrigerants have on average a lower GWP than the CFCs and HCFCs they replaced, they are still potent greenhouse gases (GHGs). The Kigali Amendment phases down the use of HFCs by imposing a schedule for reducing a weighted GWP value to be implemented by a country through the year 2047 (Figure 1). It provides four paths depending on the country location and category assigned in the MP, and also prescribes a method for establishing the baseline consumption used for calculating GWP reductions. For developing countries, it is expected to bring the weighed GWP across all refrigeration applications down to about 300 from the baseline value of about 2000. The implementation of Kigali Amendment aims at reducing the future warming due to HFCs from the range of 0.3 °C to 0.5 °C to less than 0.1 °C [5]. While this reduction may seem to be small, it must be viewed in the context of the 2015 Paris Agreement [6], which calls for holding global warming to well below 2 °C and pursuing to limit global warming to 1.5 °C relative to pre-industrial levels [6]. Considering that average global temperatures reached 1 °C above pre-industrial levels for the first time in 2015 [7], the Earth is already within 1 °C of the “2 °C limit”.The low-GWP requirement narrows the pool of fluids that can be considered for application as a refrigerant [8]. This Informatory Note discusses low-GWP refrigerant options for major applications and presents their selection merits.

Yana Motta, Samuel↗

A Review of the Research and Development of Brayton Cycle Technology in Nuclear Power Applications with a Focus on Compressor Technology

This study reviews the integration of Brayton Cycle (BC) systems in nuclear power generation, emphasizing their potential to enhance thermal efficiency and operational flexibility over traditional Rankine Cycle (RC) systems. Key working fluids, such as helium (He), supercritical carbon dioxide (sCO 2 ), nitrogen (N 2 ), and air, are evaluated for their performance, efficiency, and compatibility with nuclear systems. He is recognized for its high thermal conductivity and inertness at elevated temperatures, while sCO 2 demonstrates advantages in compactness and efficiency in midrange temperatures. This article also highlights the importance of compressor designs in optimizing BC performance and reviews, available compressor technologies. Axial and centrifugal compressor designs enable efficient gas compression while managing the thermal and mechanical stresses associated with high-pressure operations in nuclear systems. Combined with variable geometry components and advanced materials, these technologies address the challenges posed by varying load conditions. Despite the promising features of BC systems, several challenges persist, including high leakage rates and material degradation under extreme conditions, which necessitate robust sealing technologies and thorough testing. The insights gained from operational experiences at facilities, such as the Oberhausen II plant and the High-Temperature He Test Facility (HHV), underscore the complexities involved in designing high-temperature gas turbines for nuclear applications. This review concludes that as the nuclear industry evolves, BC systems hold significant promise for contributing to a sustainable energy future, particularly in the context of small modular reactors (SMRs) and microreactors. Further exploration of combined cycle configurations that combine BCs with RCs may enhance overall efficiency and flexibility in power generation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗