Search NASA⌕ Search

SEARCH · Search NASA

Results for “Contact time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of Peracetic Acid in Poultry Processing: Effects of Treatment Dynamics and Emerging Risk of Resistance Development in Salmonella spp.

Nontyphoidal Salmonella is a leading cause of foodborne illness, with poultry representing a major source. Peracetic acid (PAA), a widely adopted antimicrobial in poultry processing, offers advantages over traditional disinfectants but has sparked interest in its combined use with other antimicrobials and potential resistance. This review evaluates the efficacy of PAA in mitigating Salmonella in combination with other food-grade antimicrobials, explores possible synergism, efficacy under varying treatment parameters, resistance development against PAA, and its role in resistance evolution. While PAA demonstrates broad-spectrum efficacy, its performance varies with environmental parameters; higher temperatures generally enhance antimicrobial action but also accelerate PAA degradation. Organic matter diminishes PAA efficacy by reactive quenching. Variability in concentration and contact time further influences outcomes. Despite its oxidative mode of action and presumed low risk for resistance, emerging studies indicate that Salmonella can develop adaptive tolerance and potential cross/coresistance following repeated or sublethal exposure to PAA. These adaptations may involve genetic upregulation of oxidative stress response pathways, efflux systems, and modifications in cell membrane integrity, raising concerns about the long-term sustainability of PAA use. Additionally, combinatorial treatments (e.g., PAA with UV-C, enzymes, or organic acids) show promise in enhancing efficacy while mitigating resistance risks. Despite recognition of PAA's safety and effectiveness, knowledge gaps remain regarding standardized resistance definitions, serotype-specific tolerance, and optimal intervention strategies in commercial settings. Therefore, there is a need for standardized testing protocols, robust studies on potential resistance, and further exploration of synergistic PAA applications to ensure sustained poultry product safety and public health protection.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from SY-101 Tank Waste Using Crystalline Silicotitanate

The newly operational Tank Side Cesium Removal (TSCR) system removes radioactive cesium-137 ( 137 Cs) and solids from tank waste supernate in the 200 east area of the Hanford site. Efforts to expand the removal capabilities to the 200 west area are underway by a system anticipated to be called the West Area Risk Management (WARM) system. Laboratory-scale ion exchange processing using expected WARM unit operations were conducted to contribute toward Washington River Protection Solutions (WRPS) establishing accurate process flowsheets for the individual feed campaigns planned for the west area supernate pretreatment. This report describes the small-scale ion exchange testing with 8.0 L of filtered supernate from tank 241-SY-101 (referred to as SY-101) at 16 °C (62 °F) to demonstrate processing conditions that would be prototypic of what the WARM system may experience. One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the SY-101 tank waste to meet this criterion, only 0.44% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 227. Testing with SY-101 matched current TSCR prototypic operations where a lead-lag configuration is used until the lag column reached the WAC limit. Neither the lead nor lag columns reached the WAC, so a polish column was never utilized during this test. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitate (CST) bed, matched the current flowrate at TSCR (an expected flowrate to be used at WARM). The lead column only reached 0.09% Cs breakthrough after processing ~1363 BVs of feed. Cesium breakthrough from the lag column was not observed during the entire processing. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics. Table S.1 and Figure S.1 also summarize the measured SY-101 Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Isolated Single Metal Atoms Supported on Silica for One Step Non-Oxidative Methane Upgrading to Hydrogen and Value-Added Hydrocarbons

Natural gas in the United States offers substantial economic opportunities due to its abundance but its transportation is challenging because its primary component, methane (CH 4 ), does not liquefy at ambient temperature and typical pressures. As a result, a significant portion of natural gas is either used for heat, flared in remote locations, or remains unutilized, presenting a lost economic opportunity and an environmental harm. Converting natural gas to larger hydrocarbons in an economically competitive manner would enable transportation of products and further boost the economy and reduce environmental footprint. Our research goal is to enable efficient non-oxidative methane conversion (NMC) via catalyst innovation to convert CH 4 in one-step to olefins and aromatics and hydrogen (H 2 ) co-product. The catalysts are made of supported single metal atoms and operated at medium-high temperatures. The single metal atoms achieve methane activation by heterogeneous surface dehydrogenation to generate a hydrocarbon pool and importantly limit coke formation. The integration of novel single atom catalysts in a short contact time microreactor enable unprecedented NMC performance that could lead to economically-feasible, distributed natural gas upgrading by advanced manufacturing and process intensification. Our innovated catalyst and reactor technology promise to tap into previously uneconomic natural gas resources, such as stranded, vented, and flared methane.

03 NATURAL GAS↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disulfonamide Ligands as f-Element Extractants from Alkaline High-Level Waste

Almost 100 million gallons of high level waste (HLW) has been generated from defense reprocessing programs to support nuclear weapons production. HLW is currently stored at the Hanford and Savannah River Sites (SRS) [1]. It contains radioactive components, such as {sup 137}Cs, {sup 99}Tc and {sup 90}Sr, as well as large amounts of non-radioactive species, including solvated cations and insoluble metal hydroxides. HLW has high concentration of soluble hydroxides ([OH{sup -}] = 2 M at SRS [2]), complexing inorganic anions ([NO{sub 3}{sup -}] ∼ 0.65 - 3.7 M at SRS [2]) and a high ionic strength. Even though the majority of actinide component in alkaline HLW is precipitated, studies of An(III) and Ln(III) complexation in highly alkaline solutions in the presence of high nitrate concentrations have showed that soluble nitrate complexes can be formed [3]. The current treatment of HLW at SRS currently consists of two processes: The Actinide Removal Process (ARP) and the Next-Generation Caustic-Side Solvent Extraction process (NG-CSSX). Strontium and actinides are removed by sorption on monosodium titanate through the Actinide Removal Process (ARP) commonly referred to as the alpha-strike step [4]. Then, cesium is selectively extracted from the alkaline media via the Caustic-Side Solvent Extraction (CSSX) process [5]. The CSSX solvent consists of a calix[4]arene-crown-6 extractant dissolved in an inert hydrocarbon matrix containing i) a solvent modifier (alkylphenoxy alcohol) which increases extractant solubility and prevents third phase formation, and ii) a suppressor (trioctylamine or guanidine) - that mitigates surfactant effects. The CSSX process removes {sup 137}Cs selectively and rapidly, yet the post- CSSX aqueous stream may still contain high amounts of An, thus requiring a second ARP treatment (referred to as 'alpha-finishing') for some tanks. Despite the success of the ARP process in removing Sr and An, it often represents the kinetic bottleneck of integrated processing, as it is slower than solvent extraction. Understanding the complexation of actinides by organic ligands that are compatible with the CSSX process could eventually lead to a combined caustic-side Cs/Sr/actinide extraction process with better economics due to a reduced amount of monosodium titanate and/or a shorter required contact time with titanate during ARP. This would ensure a low-activity waste (LAW) stream with no actinides without additional ARP processing post-CSSX. Disulfonamides were studied for extraction of Sm(III) from alkaline aqueous media of pH 10-14 into dichloromethane. Up to 82% of Sm(III) was extracted from solutions of pH 12.5 -13.5 and up to 84% from solutions of pH 10.5 - 11.5. These results show some resemblance with Am extraction results by calixarene ligands previously reported [10]. Kinetic studies demonstrated that even 5 min is enough to complete stripping, whereas extraction is time-limiting process and requires up to 20 h for efficient removal of Sm(III) from alkaline aqueous media. Determination of composition of complexes in solution after extraction by the equilibrium shift method showed a 1:1 Sm(III):dsa-2 complexation ratio for the extracted species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel technology of non-contact real-time radiation damage sensors for high power targets.

This report summarizes the contributions of an intern participating in the Community College Internship (CCI) program at Fermilab, focusing on the development of a novel, non-contact, real-time radiation damage sensor technology. The core objective is to create a reliable sensor capable of measuring radiation-induced degradation on high-power targets without physical contact. The experiment involves using a Class 3B supercontinuum laser directed toward a single material sample placed within a vacuum test chamber. The laser beam reflects off the sample's surface, with changes in reflectivity, indicative of radiation damage, measured by a spectrometer positioned at the chamber’s output port. The intern’s primary responsibilities included designing an interlock system to ensure laser operational safety, developing a camera-based monitoring system using Raspberry Pi devices, and creating structural supports using 3D modeling and printing techniques. Components for the interlock and camera systems were successfully designed and ordered, with preliminary 3D models printed and refined through iterative testing. Challenges encountered in the 3D printing process, such as fragile initial prototypes and difficult support removal, were overcome by adjusting printer settings and incorporating design enhancements like chamfered edges. Future activities, pending component delivery, involve installing and configuring the interlock and camera systems, as well as further improving the structural supports. Overall, the internship significantly enhanced the intern’s technical proficiency in hardware design, software integration, and advanced 3D printing, contributing directly to Fermilab’s operational safety standards and experimental effectiveness in high-energy physics research.

Pumarino Meza, Rafael [Unlisted; Fermilab]↗

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Workshop on Using a Git-based Repository for ASTM Committee Technical Knowledge Capture [Slides]

Consensus technical standards maintained by ASTM International rely on individual contributors to act as technical contacts, effectively stewards, for a particular standard. As a particular standard’s technical content evolves over time, the contact must update relevant tables, graphics, and supporting discussion. However, the details of the data sources and/or processes used to perform such updates may be separate enough from the standard such that expert knowledge is required to perform these updates. As a result of this need for expert knowledge, and the desire to capture that knowledge, subcommittee E10.05 (Nuclear Radiation Metrology) has experimented with using a git-based repository to capture data and processes to reproduce figures needed by E10.05 to maintain the ASTM standards under their jurisdiction. This workshop will provide an overview of the git-based repository site’s organization, operation, and outputs. It will then lead interested workshop participants through adding content, not yet already included in the repository to the site.

42 ENGINEERING↗

UO 2 solubility and chemical interactions in molten LiCl-Li 2 O

Here, this study investigated the solubility of UO 2 in LiCl-2 wt% Li 2 O at 650 °C with O 2 partial pressures up to 114 torr. Experiments were run in which UO 2 powder was contacted with the molten salt for up to 120 h. Salt samples were taken and analyzed for U and corrosion product concentration using inductively coupled plasma mass spectrometry and for Li 2 O concentration using titration. The highest measured U concentration in the salt was 0.06 wt%, and O 2 partial pressure was observed to have little to no effect on the solubility. Increasing O 2 partial pressure did increase the concentration of corrosion products in the salt. The concentration of Li 2 O in the molten salt progressively decreased with time in contact with UO 2 . This can be explained by the formation of Li 2 UO 4 via reaction of UO 2 with Li 2 O.

36 MATERIALS SCIENCE↗

Corrosion of Commercial Mg–Al Alloys: AZ31B, AM60, and AZ91D

Aqueous corrosion, atmospheric corrosion, and ionic liquid dissolution studies were performed on commercial alloys AZ31B, AM60, and AZ91D and compared with previously reported results for single-phase binary Mg–Al alloys containing similar Al concentrations (αMg-2 at% Al, αMg-5 at% Al, and Mg-8 at% Al). Polarization studies in 0.6 M NaCl were used to characterize the aqueous free corrosion behavior during 20-h free immersion. Accelerated corrosion testing was performed using a rotating-disk electrode which revealed the evolution of an Al-rich mud-cracking and platelet morphology. Atmospheric droplet testing showed rapid pH increases that depended on the Al concentration in the alloy. Time-dependent contact angle measurements showed that the degree of droplet wetting increased during free corrosion by ~50° over 20 h in 0.6 M NaCl. Ionic liquid dissolution studies in 1:2 M choline chloride:urea deep eutectic solvent were performed in order to examine the current-voltage behavior of these alloys in the absence of water and hydrogen reduction. The results of these studies revealed the formation of nanowire corrosion morphologies within a honeycomb lattice structure which we attribute to selective dissolution of Mg via a two-dimensional stepflow process

25 ENERGY STORAGE↗

Data and scripts associated with “Non-random processes impacting organic matter chemistry are maximized in mid-order streams”

NOTE: The manuscript associated with this data package is currently in review. The data may be revised based on reviewer feedback. Upon manuscript acceptance, this data package will be updated with the final dataset and additional metadata. This data package is associated with the publication “Non-random processes impacting organic matter chemistry are maximized in mid-order streams” submitted to Limnology and Oceanography (L&O) by Danczak et al. (in review). This package contains data and scripts used to investigate dissolved organic matter (DOM) molecular chemistry and diversification processes across 47 surface-water sampling sites in the Yakima River Basin, Washington, USA, during an August 2021 sampling campaign. The package contains analyses of ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), geochemical measurements, geospatial attributes, molecular diversity, and meta-metabolome ecological null models needed to reproduce the main manuscript results. The underlying field data were pulled from exising data packages at https://doi.org/10.15485/1892052 (Fulton et al., 2022) and https://doi.org/10.15485/1898914 (Grieger et al., 2022). For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. We thank the following organizations for providing access to field locations for sample collection: the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, the Confederated Tribes and Bands of the Yakama Nation, and the Cowiche Canyon Conservatory. Research was conducted under Washington State Parks and Recreation Commission Scientific Research Permit #210901. We are grateful to the Yakama Nation Tribal Council and Yakama Nation Fisheries for their collaboration in facilitating sample collection and ensuring data usage aligns with their values and worldview. This data package contains an R-Markdown file for analyses and five folders: (1) Data, (2) Geospatial Data, (3) Supplemental_Files, (5) Figures_pdf, (4) and src. The Data folder contains tabular inputs and derived files used in the manuscript analysis. The Geospatial Data folder contains climate and water-balance, hydrologic, land-cover, population/regional water-use, stream, topographic, and stream-order attribute CSV files. The src folder contains scripts used to process data, run analyses, and generate figures. The Figures_pdf folder contains manuscript figure outputs. The Supplemental_Files folder contains supplemental analysis products. All files are .csv, .pdf, .html, .png, .R, .Rmd, .svg, or .tre. This data package is associated with the rcfsa-RC2-SPS_Null_Modeling repository found at https://github.com/river-corridors-sfa/rcfsa-RC2-SPS_Null_Modeling.

54 ENVIRONMENTAL SCIENCES↗

Toward Wireless Smart Grid Communications: An Evaluation of Protocol Latencies in an Open-Source 5G Testbed

Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.

42 ENGINEERING↗