Search NASA⌕ Search

SEARCH · Search NASA

Results for “Critical Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of Boiling-Induced Thermal Degradation Using Microporous Nickel Inverse Opals Structures

Engineered microporous structures have received much attention in high-heat-flux electronics cooling due to their high thermal conductivity and permeability, and large surface area for heat transfer, but are susceptible to boiling-induced thermal degradation. Here, this study investigates the efficacy of nickel inverse opals (NiIOs) in mitigating structural degradation caused by corrosion-assisted erosion during pool boiling with water as the working fluid. First, we compared the reliability of NiIOs to copper inverse opals (CuIOs) for a 3-day pool boiling test at constant heat flux. The NiIOs demonstrated superior resistance to thermal degradation due to their inherent corrosion resistance and mechanical strength. Subsequently, we conducted a more controlled experiment to show the effect of heat flux on the degradation of the NiIOs while excluding the effect of temperature variations. Pool boiling tests of 20-μm-thickness NiIOs covering an area of ∼11 × 11 mm 2 with a 2.5 × 2.5 mm 2 heater at the center were conducted at heat flux levels of 20%, 40%, and 60% of the critical heat flux (CHF) for 3 days. The NiIOs subjected to heat flux levels of 20% and 40% CHF showed minimal degradation, while the sample subjected to 60% CHF showed erosion on the top surface due to higher bubble formation and departure rate. These results show the potential of NiIOs as a promising solution for long-term thermal management in high-power electronic devices, although design considerations for maximum allowable heat flux are necessary for reliable operation.

36 MATERIALS SCIENCE↗

Mechanical and chemical properties of PVD and cold spray Cr-coatings on Zircaloy-4

In this paper, accident-tolerant fuel (ATF) cladding materials aim to improve fuel reliability and safety during accident scenarios in water-cooled reactors. These ATF cladding should also perform comparable or better than the current zirconium alloy cladding under reactor normal operating conditions. Surface-modified Zircaloy-4 was produced by depositing a protective coating of chromium by two different coating techniques, Physical Vapor Deposition (PVD) and Cold Spray (CS). The coating thickness, structure, composition, and mechanical properties of the coated Zircaloy were assessed with advanced materials characterization techniques. Results showed a strengthening effect of the Cr-coating, along with ~83% higher hardness compared to that of the Zircaloy-4 substrate. Surface topography and surface chemistry of the Cr-coated Zircaloy-4 were assessed with contact profilometry, atomic force microscopy, contact angle goniometry, and X-ray photoelectron spectroscopy. Deposited Cr-coating significantly improved surface wettability compared to the substrate Zircaloy-4. The formation of surface oxides on the coatings by prolonged exposure to ambient air showed a further increase in the hydrophobic behavior. Surface parameters and surface chemistry after flow boiling critical heat flux tests, conducted at atmospheric pressure, evidenced a slight increase in surface roughness with notable changes in wettability associated with the formation of surface oxides.

36 MATERIALS SCIENCE↗

Forced flow transient safety analysis of irradiation device with adjustable orifice for research reactor fuel assemblies

The Belgium Reactor 2 (BR2) of the Belgian Nuclear Research Centre (SCK CEN) has several irradiation devices or rigs that are dedicated to the fuel performance and qualification demonstration testing of research reactor fuels. In support of the U.S. High Performance Research Reactor (USHPRR) LEU conversion project, a new flexible irradiation apparatus, MUSTANG-R, has been constructed. SCK CEN has completed the design and safety study, in cooperation with Idaho National Laboratory (INL) and Argonne National Laboratory (ANL), to allow for the irradiation testing of a full-size fuel assembly in a 200 mm diameter channel in the BR2 reactor. The moveable valve is a key design feature of the device and acts like an adjustable orifice enhancing or restricting the flow through a coolant channel inlet located in the BR2 upper plenum. This moveable valve allows the flow through the device to be adjusted prior to each BR2 cycle to obtain the necessary conditions for the fuel qualification test. This ensures accurate and representative thermal-hydraulic conditions of the fuel design are achieved. The device was designed and qualified as passively safe, implying verification by a combination of mechanical and thermal-hydraulic analysis and testing. This includes characterization of the safety margin required for a scenario where the moveable valve is assumed to be erroneously closed during irradiation. A simplified and conservative method is proposed for analyzing the corresponding forced flow transient using a critical heat flux criterion. In conclusion, this allows the required minimum valve opening to be determined for the experiments' design and safety studies.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three‐Tier Hierarchical Structures for Extreme Pool Boiling Heat Transfer Performance

Abstract Boiling is an effective energy‐transfer process with substantial utility in energy applications. Boiling performance is described mainly by the heat‐transfer coefficient (HTC) and critical heat flux (CHF). Recent efforts for the simultaneous enhancement of HTC and CHF have been limited by an intrinsic trade‐off between them—HTC enhancement requires high nucleation‐site density, which can increase bubble coalescence resulting in limited CHF enhancement. In this work, this trade‐off is overcome by designing three‐tier hierarchical structures. The bubble coalescence is minimized to enhance the CHF by defining nucleation sites with microcavities interspersed within hemi‐wicking structures. Meanwhile, the reduced nucleation‐site density is compensated for by incorporating nanostructures that promote evaporation for HTC enhancement. The hierarchical structures demonstrate the simultaneous enhancement of HTC and CHF up to 389% and 138%, respectively, compared to a smooth surface. This extreme boiling performance can lead to significant energy savings in a variety of boiling applications.

36 MATERIALS SCIENCE↗

Recent progresses on thermal–hydraulics evaluations of accident tolerant fuel cladding materials

Thermal–hydraulics (T-H) experiments have been on the progress to evaluate boiling heat transfer characteristics of accident tolerant fuel (ATF) candidates for further supporting the core-loading of these advanced ATF concepts in light water reactors (LWRs). Here this study covers recent experimental studies of ATF claddings and summarizes some significant results. Recent T-H experimental results of ATF cladding candidates demonstrated that the material thermal–physical properties have pronounced effects on critical heat flux (CHF). Such effects have not been well resolved in the current physics-governing models. These effects of cladding materials on CHF could be potentially rationalized by the material-conjugated boiling heat transfer, where the material-dominated heat conduction competes with the flow boiling-dominated heat convection. As progressively increasing the mass flux and/or liquid subcooling, CHF differences between different materials gradually decrease, which is in agreement with the recent T-H experimental results of ATF claddings. This is because the dominance of heat convection over heat conduction is primarily improved by liquid subcooling and/or mass flow rate. It is noteworthy that surface oxidization of claddings may have unknown impacts on T-H performances because the formation of oxide layers on cladding surfaces introduces variations of material thermal–physical properties and then changes the surface morphological features, which results in some difficulties in evaluating the thermal safety margins of ATF claddings.

36 MATERIALS SCIENCE↗

Evolution of Microstructure and Surface Characteristics of FeCrAl alloys when Subjected to Flow Boiling Testing

FeCrAl alloys are candidate materials for manufacturing accident-tolerant fuel (ATF) cladding intended for light water reactors to increase fuel reliability and safety during design-basis and beyond-design-basis accident scenarios. The evolution of the materials' surface characteristics, microstructure, and mechanical properties when exposed to the Critical Heat Flux (CHF) in flow boiling testing is crucial for safety analysis while providing insights into their thermal-hydraulic performance in nuclear reactors. After CHF, the surface chemistry of two FeCrAl alloys, APMT and C26M, was studied to understand their evolution at the early stage of high-temperature excursions in short time periods. The results indicated a thin layer composed of oxides and hydroxides of Al, Cr, and Fe with varying proportions at different depths in the layer, as indicated by X-ray photoelectron spectroscopy (XPS) and depth profiling. The cross-sections prepared by focused ion beam (FIB) revealed the growth of an oxide layer, in the range of 90-180 nm thick, on the alloys' surfaces. The evolution of the materials' surface chemistry also led to a noticeable post CHF excursion increase in their wettability, with a slight increase in roughness. Further, the investigation of the materials' mechanical properties indicated a modest increase in hardness by 10-15% as well as an increase in their yield strength, as evidenced by the microindentation and ring compression tests conducted before and after CHF testing. Scanning electron Microscopy (SEM) and X-ray diffraction (XRD) were used to investigate microstructural features of the materials and their changes after CHF treatment.

36 MATERIALS SCIENCE↗

Results of the CHF-SERTTA In-Pile Transient Boiling Experiments at TREAT

To advance the current understanding of heat transfer between nuclear fuel rod cladding and the surrounding coolant under transient scenarios involving critical heat flux (CHF), the CHF-Static Environment Rodlet Transient Test Apparatus (CHFSERTTA), an in-pile experiment, was developed for and irradiated in the Transient Reactor Test (TREAT) facility at Idaho National Laboratory. The CHF-SERTTA experiment consists of a hollow, borated stainless steel rod submerged in a static water pool. The rod, heated via the (n, a) reaction in boron-10, was designed for investigating in-pile transient heat transfer between the rod surface and the coolant, avoiding the complexity of including the heat transfer between the fuel, gas gap, and cladding in typical light-water reactor (LWR) fuel rods. The instrumentation package for CHF-SERTTA focused on capturing those data that best describe the heat transfer behaviour between the rod and coolant. This paper outlines the CHFSERTTA experiment design and presents the initial results of the experiment campaign.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Alteration of pool boiling heat transfer on metallic surfaces by in situ oxidation

The critical heat flux during pool boiling has been investigated for a range of applications including electrical power generation and thermal management. Reported experimental CHF values during pool boiling of water on flat metallic surfaces, however, show a large discrepancy across studies. Here, we address this discrepancy in CHF values by accounting for oxidation of metallic surfaces during boiling. We studied the effect of in situ oxidation on flat Cu and Ni surfaces by changing the duration that samples were held in saturated water before conducting boiling experiments. The morphology and chemical composition of surfaces after the boiling experiments were analyzed by atomic force microscopy and X-ray photoelectron spectroscopy, respectively. Cu surfaces showed gradually increasing CHF values as the duration in saturated water increased, which could be attributed to the increase in roughness due to the formation of Cu 2 O nanostructures. Conversely, Ni surfaces showed relatively stable CHF and morphology as a nearly flat layer of NiO formed, with one exception: formation of a highly wetting hydroxide, Ni(OH) 2 , on a Ni coupon held in saturated water for 24 h resulted in a uniquely high CHF value, signifying the importance of surface chemistry in addition to morphology. Finally, the fundamental mechanisms resulting in the wide spread of CHF values on metallic surfaces elucidated in this work will lead to more accurate estimation of CHF as well as a deeper mechanistic understanding of CHF values on engineered surfaces.

42 ENGINEERING↗

Data efficiency assessment of generative adversarial networks in energy applications

This study investigates the data requirements of generative artificial intelligence (AI), particularly generative adversarial networks (GANs), for reliable data augmentation in energy applications. Generative AI, though seen as a solution to data limitations, requires substantial data to learn meaningful distributions—a challenge often overlooked. This study addresses the challenge through synthetic data generation for critical heat flux (CHF) and power grid demand, focusing on renewable and nuclear energy. Two variants of GAN employed are conditional GAN (cGAN) and Wasserstein GAN (wGAN). Our findings include the strong dependency of GAN on data size, with performance declining on smaller datasets and varying performance when generalizing to unseen experiments. Mass flux and heated length significantly influence CHF predictions. wGAN is more robust to feature exclusion, making it suitable for constrained synthetic data generation. In energy demand forecasting, wGAN performed well for solar, wind, and load predictions. Longer lookback hours and larger datasets improved predictions, especially for load power. Seasonal variations posed challenges, with wGAN achieving a relatively high error of Root Mean Squared Error (RMSE) of 0.32 for load power prediction, compared to RMSE of 0.07 under same-season conditions. Feature exclusions impacted cGAN the most, while wGAN showed greater robustness. This study concludes that, while generative AI is effective for data augmentation, it requires substantial data and careful training to generate realistic synthetic data and generalize to new experiments in engineering applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A non-fueled nuclear-heated rod for in-pile transient boiling studies

Separate-effects boiling experiments have recently been conducted in the Transient Reactor Test Facility at Idaho National Laboratory to investigate transient heating and irradiation effects on cladding-to-coolant heat transfer. Specifically, transient critical heat flux (CHF) remains an important area of research, and better understanding of this phenomenon has potential for improving predictive models related to operational and safety limits. Consequently, this knowledge is expected to improve efficiency of light-water reactor operations. A novel borated nuclear-heated rodlet (BNHR) was designed to enable observation of transient cladding-to-coolant heat transfer phenomena. The final BNHR design takes a surrogate approach, wherein nuclear heating is induced by 10 B(n, α) reactions rather than derived from fissions in a fueled specimen. The structure of the BNHR consists of a hollowed out borated (B nat ~ 2.05 wt %) stainless steel tube with an hourglass-shaped outer surface, capped at both ends with non-borated stainless steel. This geometry allows for inner-rodlet instrumentation and generation of the highest nuclear heating rates near the center of the rodlet to ensure onset of boiling near instrumentation for real-time observation. A novel approach to measuring the nuclear energy deposition rate in the BNHR separate and apart from the influence of the coolant, termed the n-a thermometer, is also detailed in this paper. This device has demonstrated excellent repeatability, and measurements indicate predictive modeling results for energy deposition in the BNHR rod agree within a 10% margin of the experiment measurements. In conclusion, these results give confidence that the BNHR design has successfully met experiment objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine Learning-based Prediction of Departure from Nucleate Boiling Power for the PSBT Benchmark

Machine Learning (ML) has seen an exponential growth in its applications due to its advanced data driven prediction capabilities. The study presents a data-driven approach as a preliminary attempt to predict the power at which departure from nucleate boiling (DNB) occurs in pressurized water reactors (PWRs) by constructing an advanced ML algorithm that takes outlet pressure, inlet temperature and inlet mass flux as the input features. DNB is a critical heat flux (CHF) phenomenon seen in PWRs. The experimental data from the PWR subchannel and bundle tests (PSBT) benchmark is first used to train an artificial neural network (ANN) to predict the DNB power, which produces a root mean square error (RMSE) of 6.89 kW/m when tested on a blind subset of the PSBT data. Since the PSBT dataset is relatively small to train an accurate ANN, a data augmentation methodology based on generative adversarial networks (GANs) is used to expand the training dataset. By assuming that the real data follows a certain distribution, GANs try to learn that underlying distribution to generate similar synthetic data to augment the database and to improve the predictive capabilities of the ANN. The data generated from GANs are validated using 1-nearest neighbor and kernel maximum mean discrepancy. To further ensure data from GAN is similar to PSBT, the data is tested and filtered out using the sub-channel thermal-hydraulic code CTF. The results indicate that with the addition of 120 data points from GAN the RMSE reduces to 4.84 kW/m showing promising results for future developments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HFIR LEU High Density Silicide Dispersion Optimized Design Steady-State Heat Transfer Analyses

Steady-state heat transfer simulations of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) with the low-enriched uranium (LEU) high-density silicide dispersion Optimized fuel design were performed to support comprehensive performance and safety metric studies concerning this design. The LEU Optimized design operates at 95 MW to maintain HFIR’s current highly enriched uranium (HEU) core performance level at 85 MW. Full cycle Mode 1 full flow Case 1 (inlet temperature), Case 2 (flux-to-flow), and Case 3 (inlet pressure) safety limit analyses were performed to assess the margins to critical heat flux. Under the prescribed conditions, this LEU design meets the safety limit and limiting control setting requirements outlined in HFIR’s documented safety analysis; however, the safety margins are less than those for the 85 MW HEU core, and several assumptions were made where fuel fabrication and qualification data are currently lacking for the silicide fuel design. Effects of changes to pertinent fuel fabrication assumptions and uncertainty factors on thermal safety margins were also evaluated, showing that the margins are sensitive to many of these parameters. Power and pressure perturbations were also performed, indicating that significant steady-state thermal margins could be gained by increasing the coolant inlet pressure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and Validation of a Two-Phase Thermal-Hydraulic CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance Computational Fluid Dynamics (CFD) code NEK5000. The goal of this work is to verify and validate the two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) previously developed at Argonne but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2020. This report focuses on verification and validation of the water-steam boiling model NEK-2P Two-Phase, CFD code. The NEK-2P was validated with Nuclear Power Engineering Corporation (NUPEC) Pressurized Water Reactor (PWR) Sub-channel and Bundle Test (PSBT) void distribution benchmark. Three different simulations were performed and analyzed for various operating conditions such as wall-heat flux and sub-cooled inlet temperatures. Reasonably good agreement with measured data was obtained in predicting the measured void distributions. Simulations were performed for Virginia Tech. (VT) 3x3 rod bundle geometry with and without spacers. The preliminary results were presented for Simplified Spacer Grid (SSG). In addition, the implementation of interface reconstruction model was tested with one of the Becker benchmark Critical Heat Flux (CHF) experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pool Fire Analysis Methodology for Assessing Damage to Waste Containers

This document provides guidelines, whereby the physical parameters associated with postulated flammable/combustible liquid pool fires are determined (thermal analysis) in order to estimate the number of waste containers impacted. Pool fire damage to waste containers may occur due to a container being fully engulfed (within the periphery of the pool), partially engulfed, or within the critical heat flux distance. The methodology described here for estimating the size of the pool fire is developed using spill characteristics outlined in Chapter 65 of the SFPE Handbook (Ref. 7) and testing done by Hansen (Ref. 25). For exposures, the critical flux height is determined using the detailed method of Shokri and Beyler (Ref. 8) from the flame height, calculated as described by Heskestad (Ref. 7) and the average black body emissive power, determined using the method of Shokri and Beyler (Ref. 8). Three types of liquid pool fires should be considered; unconfined crash/instantaneous spill fires, unconfined continuously flowing (also called metered leak) spill fires, and confined spill fires. All fuel sources should be considered consistent with the facility Fire Hazard Analysis (FHA). However, the most likely liquid fuel sources present in TRU waste facilities are those present on TRU waste handling vehicles (forklifts, pallet movers, transport trucks, etc.). This method can also be used for assessing damage to items other than waste containers or other methods of analysis may be used with appropriate justification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Effect of PVD-coated chromium on the subcooled flow boiling performance of nuclear reactor cladding materials

Here we elucidate the separate effect of a thin Cr coating deposited by physical vapor deposition (PVD) on the subcooled flow boiling performance of zircaloy-4. First, we run flow boiling experiments on prototypical zircaloy-4 surfaces mimicking the scratch pattern and surface roughness of nuclear reactor claddings. Then, we PVD-coat a 0.3 µm thick chromium layer on the same exact surface and repeat the same flow boiling investigations. All experiments are run using deionized water at atmospheric pressure, flowing on a 1 × 3 cm 2 rectangular cross section channel at a rate of 1000 kg/m 2 /s and a subcooling of 10 K. We measure the average temperature of the boiling surface at increasing surface heat fluxes, covering a wide range of heat transfer regimes, from single-phase forced convection to the boiling crisis. We also record high-speed videos of the boiling process, which we postprocess to measure bubble nucleation site density, growth time, departure diameter and frequency. The surface analysis reveals that, while the chromium coating does not seem change the surface roughness and morphology, it improves surface wettability. However, it decreases the critical heat flux. The chromium coating causes an increase of nucleation temperature, bubble departure diameter and growth time, and a reduction of the nucleation site density. The concurrence of these observations indicates that a size reduction of the nucleation sites, conformally covered by the chromium coating, may be the cause of the boiling performance deterioration. We confirm this hypothesis repeating the same analysis on a FeCrAl sample prepared and tested using the same protocol as the zircaloy-4 sample, but with a different initial surface texture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗