Search NASA⌕ Search

SEARCH · Search NASA

Results for “DARHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability eXpansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. The Department of Energy/National Nuclear Security Administration (DOE/ NNSA) Stockpile Stewardship Management Plan (SSMP) identifies DARHT as a weapons mission critical facility along with the need to modernize DARHT to support weapons modernization efforts. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75 th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. The 2018 Nuclear Posture Review (NPR) states that the nuclear weapons infrastructure has suffered the effects of age and underfunding with no margin for further delay in recapitalizing the physical infrastructure. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability eXpansion (DCX) Strategy

This document details the strategy proposed to meet the National Nuclear Security Administration (NNSA) requirement for the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility Sustainment and Modernization projects identified in multiple NNSA Stockpile Stewardship and Management Plan (SSMP) reports to Congress [NNSA, 2020; 2021; 2022; 2023; 2024]. DARHT has become indispensable for the certification of the primaries of U.S. nuclear weapons since the current U.S. moratorium halted underground nuclear testing more than 30 years ago. However, aging facilities, evolving technology, and other issues are limiting or threatening the capability of DARHT to meet NNSA’s expanding mission needs now and into the future. This DARHT Capability eXpansion (DCX) strategy was developed to address NNSA needs by extending DARHT’s reliability and resilience, increasing the quality and quantity of DARHT data, and enabling hydrodynamic measurements in complex environments. The strategy can be implemented through integration of line-item projects, acquisition of major items of equipment, and other actions coordinated with the execution of the SSMP. This strategy document is intended for U.S. Government officials, particularly authorizers, appropriators, and program leaders. It may also be furnished to DARHT users, customers, collaborators, stakeholders, and visitors as needed

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Dual-Axis Radiographic Hydrodynamic Test Facility Capability Expansion (DCX) Strategy

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is a vital and important part of the Nation’s nuclear security enterprise. With more than two decades of operations, DARHT has a storied history. Conceived in the 1970s, constructed in the 1990s, and operational since 2000, DARHT has advanced from open-air hydrodynamic experiments (hydros) to foam-confined hydros, to vessel-confined hydros, and in 2022, the 75th hydro was successfully completed. Radiography has advanced from a single-axis, single-pulse system to a dual-axis, multi-pulse capability to variable fields of view (VFV) on both accelerators. The culmination of these experiences, accomplishments, and advancements has brought us to a very important question: What do the next two decades at DARHT look like? The world is not the same place it was in the 1990s when construction at DARHT was in progress. Evolving threats, an expanding mission, and technology changes necessitate adaptation. To adapt, the aging facility, accelerators, vessels, and detector systems require improvements to ensure DARHT remains the Nation’s hydrodynamic data foundation for stockpile certification, safety, surety, and global security threats.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Unwrapping Radiograph Target Disassembly Using Adaptive Machine Learning [Slides]

Advanced analysis methods were developed to determine the electron temperature and density evolution of targets disassembly by intense electron beams at DARHT based on shearing interferometer and shadowgraph measurements. New methods have been developed to spatially and temporally resolve electron velocity and temperature, expanding on recently published first results of Aluminum target disassembly. A surrogate model has been created for use in developing Adaptive Machine Learning analysis techniques. The results will also be used to guide the development of the system and experimental approach to future measurements on DARHT Axis-I and a new system to be deployed on DARHT Axis-II.

43 PARTICLE ACCELERATORS↗

Acceptance Testing of the Scorpius Sweep Magnet

A beam-dump magnet for Scorpius has been defined by LANL and designed and built by Radiabeam Technologies. Initial verification of the Radiabeam design used a magnetic field model provided by Radiabeam and analyzed by LANL tools during September 2021. Simulations indicated that the design was sufficient to meet deflection requirements to protect sensitive equipment in the case of a failed target. In January 2022, the magnet was fabricated and Radiabeam conducted measurements of the magnetic field as a function of position. The measurements deviate somewhat from the simulation. In particular, the peak magnetic field is 10-15% smaller in magnitude than expected from simulation. This note compares the magnetic field measurements to simulation and to measurements of the existing DARHT magnet, which was designed for the same purpose. We show a comparison of the measured beam deflection performance between Scorpius and DARHT and show updated results of LANL’s electron beam tracking code using the Scorpius measurements. Using field measurements we find that the DARHT magnet will deflect a 19.6 MeV electron beam by 46.6° and the Scorpius magnet will deflect by 44.6°. These results show that the as-built Scorpius magnet has met design requirements for beam deflection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resilient GaN-based Power Module with Improved Diagnostic for Future Accelerator

Los Alamos Neutron Science Center (LANSCE) and Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) play a pivotal role in advancing scientific research and national security initiatives. As a premier facility for neutron science, LANSCE and DARHT provide invaluable insights into fundamental research, materials science, nuclear physics, high-energy physics, material science, and medical imaging. Existing (DC) power supply and pulse modulation technologies used in LANSCE and DARHT face limitations in terms of reliability, maintainability, and diagnostics which hinder the progress of these cutting-edge facilities. By proposing improvements to LANL accelerator facilities’ performance and addressing component failure, we aim to enhance scientific outcomes and minimize disruptions, allowing for more efficient and productive research activities while ensuring the continuity of valuable contributions to the user community. This proposal aims to revolutionize (DC) power supply and pulse power systems for future particle accelerators via the development of a resilient GaN-based power module with improved diagnostic and redundant submodules.

43 PARTICLE ACCELERATORS↗

Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the electron beam energy. Axis-1 of DARHT produces a 20 MeV, 2 kA, 80-ns-FWHM electron beam. Electronic measurement with cell-voltage monitors which consists of a 75 ohm load resistor and a current viewing resistor (CVR) that are coupled together and injector capacitive monitors (EVACSUM) are summed to give the total beam energy at the output of the accelerator. Calibration of these monitors was last done in 1999 and is needed. Using the Compact electron Permanent Magnet Spectrometer (CePMSpec), we have developed a technique for measuring and adjusting the calibration of the accelerator cell load resistor/CVR by using the total energy of the beam. Each pair of cells is driven by pulsed power Blumleins, and each Blumlein is charged by a Blumlein Charge Unit (BCU). There are 64 cells and 32 Blumleins and BCUs. This technique is applied to all 32 BCUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scorpius and The Integrated Test Stand [Slides]

Scorpius will provide (DARHT scale) flash-radiography of dynamic nuclear material. DARHT radiographs non-nuclear (surrogate) materials at a cadence of 8 to 10 hydrodynamic shots per year. Scorpius will radiograph nuclear material at an initial cadence of about 2 to 3 subcritical shots per year in a more challenging environment. Both machines are Linear Induction Accelerators (LIAs) and generate X-rays with high-current, relativistic electron beams. Their use is termed Flash-Radiography.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗