Search NASA⌕ Search

SEARCH · Search NASA

Results for “DATA LOGGERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Flight Experience With Lightweight, Low-Power Miniaturized Instrumentation Systems

Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this paper is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. The paper will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. The paper also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. Finally, future plans for these systems will be discussed.

Flight Testing↗

Veggie Hardware Validation Test Preliminary Results and Lessons Learned

The Veggie hardware validation test, VEG-01, was conducted on the International Space Station during Expeditions 39 and 40 from May through June of 2014. The Veggie hardware and the VEG-01 experiment payload were launched to station aboard the SpaceX-3 resupply mission in April, 2014. Veggie was installed in an Expedite-the-Processing-of-Experiments-to-Space-Station (ExPRESS) rack in the Columbus module, and the VEG-01 validation test was initiated. Veggie installation was successful, and power was supplied to the unit. The hardware was programmed and the root mat reservoir and plant pillows were installed without issue. As expected, a small amount of growth media was observed in the sealed bags which enclosed the plant pillows when they were destowed. Astronaut Steve Swanson used the wet/dry vacuum to clean up the escaped particles. Water insertion or priming the first plant pillow was unsuccessful as an issue prevented water movement through the quick disconnect. All subsequent pillows were successfully primed, and the initial pillow was replaced with a backup pillow and successfully primed. Six pillows were primed, but only five pillows had plants which germinated. After about a week and a half it was observed that plants were not growing well and that pillow wicks were dry. This indicated that the reservoir was not supplying sufficient water to the pillows via wicking, and so the team reverted to an operational fix which added water directly to the plant pillows. Direct watering of the pillows led to a recovery in several of the stressed plants; a couple of which did not recover. An important lesson learned involved Veggie's bellows. The bellows tended to float and interfere with operations when opened, so Steve secured them to the baseplate during plant tending operations. Due to the perceived intensity of the LED lights, the crew found it challenging to both work under the lights and read crew procedures on their computer. Although the lights are not a safety hazard, for visual comfort crewmembers were advised to wear sunglasses when working with the plants and then they can lift glasses to read procedures. Steve Swanson had already trail-blazed this procedure when he initiated VEG-01. The temperature and humidity data logger was relocated mid-experiment to provide measurements on both sides of the unit. Images of the plants were downlinked weekly, and videos of installation and harvest were recorded. This imaging frequency was not sufficient to monitor and respond to changes in plant growth. Plants, samples, and data loggers will be returned on SpaceX-4, scheduled to return the fall of 2014. Lessons learned will be translated into hardware and operational modifications for future Veggie payloads.

International Space Station↗

MRE-Code-Hub/extract_loggernet

This script is used to read the infinitely growing data files created by a Campbell Data Logger to extract hourly data and write the content to hourly output files.

Sivaraman, Chitra↗

A network of soil moisture, soil temperature, air temperature, net radiation, ground heat flux and ground water for Chicago, Illinois

This dataset contains environmental monitoring data collected using solar-powered Multi-Function Research (MFR) Long Range Wide Area (LoRaWAN)-enabled nodes at 11 sites in Chicago, Illinois, as part of the DOE Urban Integrated Field Lab CROCUS project. The MFR node system consists of an Input/Output Digital Input Module (IB8) interface box (ICT International) providing wired connections for environmental sensors and an MFR-Node-L data logger that manages power, data processing, and LoRaWAN communication. The wireless data are ingested via Sage network (https://sagecontinuum.org/) nodes that contain LoRaWAN antennae. Measurements were collected from 11 MFR nodes deployed across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), West Woodlawn "Blacks in Green" (BIG), and Indian Boundary Prairies (IBP). Each MFR node supports a consistent suite of sensors measuring atmospheric, soil, and hydrological variables. Atmospheric measurements include 2m air temperature (°C), 2m vapor pressure deficit (kPa), and 2m shortwave/longwave radiation (incoming and outgoing, W/m²) measured using ATH-VPD and Apogee SN500 sensors. Soil measurements include volumetric water content (VWC, %) and temperature (°C) at four depths (15, 30, 45, and 60 cm below surface) using Meter Teros54 sensors, and heat flux (W/m²) at 10 cm depth using Huske HFP01-05 sensors. At selected locations, Meter Hydros21 sensors measure groundwater depth (mm), specific conductivity (dS/m), and temperature (°C). The dataset includes timestamps, site identifiers with location names, device IDs, Global Positioning System (GPS) coordinates, variable names with units, measurement depths, values, sensor names, and Sage node identifiers. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 6-bit binary system indicating physical range violations, step spikes, 24-hour flat-line conditions, 6-hour jitter, 7-day ultra-low variance, and persistent high offset. Data is provided in CSV and CF-compliant NetCDF formats. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Sap Flow Meter (SFM1x) sensors.

Chicago↗

Description and evaluation of the Acoustic Profiling of Ocean Currents (APOC) system used on R. V. Oceanus cruise 96 on 11-22 May 1981

The underway current profiling system which consists of a microprocessor controlled data logger that collects and formats data from a four beam Ametek-Straza 300 kHz acoustic Doppler current profiler, heading from the ship's gyrocompass, and navigation information from a Loran-C receiver and a satellite navigation unit is discussed. Data are recorded on magnetic tape and real time is calculated. Time averaging is required to remove effects of ship motion. An intercomparison is made with a moored vector measuring current meter (VMCM). The mean difference in hourly averaged APOC and VMCM currents over the four hour intercomparison is a few mm s minus including: two Gulf Stream crossings, a warm core ring survey, and shallow water in a frontal zone to the east of Nantucket Shoals.

Joyce, T. M.↗

Long term measurement network for FIFE

The objectives were: to obtain selected instruments which were not standard equipment on the Portable Automated Mesometeorological (PAM) and Data Control Platform (DCP) stations; to assist in incorporation of these instruments onto the PAM and DCP stations; to help provide routine maintenance of the instruments; to conduct periodic instrument calibrations; and to repair or replace malfunctioning instruments when possible. All of the objectives were or will be met soon. All instruments and the necessary instrument stands were purchased or made and were available for inclusion on the PAM and DCP stations before the beginning of the IFC-1. Due to problems beyond control, the DCP stations experienced considerable difficulty in becoming operational. To fill some of the gaps caused by the DCP problems, Campbell CR21-X data loggers were installed and the data collected on cassette tapes. Periodic checks of all instruments were made, to maintain data quality, to make necessary adjustments in certain instruments, to replace malfunctioning instruments, and to provide instrument calibration. All instruments will be calibrated before the beginning of the 1988 growing season as soon as the weather permits access to all stations and provides conditions that are not too harsh to work in for extended periods of time.

Blad, Blaine L.↗

Seismic Survey 2016 Data at Crescent Valley, Nevada

In September 2016, 989 vertical-component seismic instruments were deployed for 75 hours at the Crescent Valley greenfield geothermal play area in Nevada. Data were recorded 12/9/16 - 12/15/16. Data are stored in individual files in one-minute increments in SEGD formats. See the metadata in Crescent Valley Station Locations.sp1, Crescent Valley Observer Logs.xls, and the attached Metadata link for details about the seismic station locations, seismic data logger specifications, instrumentation specifications, descriptions of data, a fracture finding summary, and the final report for the 2016 seismic survey done in Crescent Valley, Nevada. Note that no discrete events were identified, and a 1750m x 2250m x 300m PSET volume of acoustic energy was delivered.

15 GEOTHERMAL ENERGY↗

Spatio-Temporal Denoising Graph Autoencoders with Data Augmentation for Missing Photovoltaic Data Imputation

The integration of the global Photovoltaic (PV) market with real time data-loggers has enabled large scale PV data analytical pipelines for power forecasting and long-term reliability assessment of PV fleets. Nevertheless, the performance of PV data analysis heavily depends on the quality of PV timeseries data. This paper proposes a novel Spatio-Temporal Denoising Graph Autoencoder (STD-GAE) framework to impute missing PV Power Data. STDGAE exploits temporal correlation, spatial coherence, and value dependencies from domain knowledge to recover missing data. It is empowered by two modules. (1) To cope with sparse yet various scenarios of missing data, STD-GAE incorporates a domain-knowledge aware data augmentation module that creates plausible variations of missing data patterns. This generalizes STD-GAE to robust imputation over different seasons and environment. (2) STD-GAE nontrivially integrates spatiotemporal graph convolution layers (to recover local missing data by observed “neighboring” PV plants) and denoising autoencoder (to recover corrupted data from augmented counterpart) to improve the accuracy of imputation accuracy at PV fleet level. We have evaluated our proposed model on two realworld PV datasets. Experimental results show that STD-GAE can achieve a gain of 43.14% in imputation accuracy and remains less sensitive to missing rate, different seasons, and missing scenarios, compared with state-of-the-art data imputation methods such as MIDA and LRTC-TNN.

Fan, Yangxin↗

WHOLESCALE: Seismic Survey Metadata from San Emidio Nevada 2021

This is a collection of metadata from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 deg N, 119.409019 deg W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The raw and processed data are in an associated GDR submission, linked below. The metadata here includes files containing experiment details, station locations, seismic data logger specifications, instrumentation specifications, and descriptions of data. Also included are data and metadata from a 2016 seismic survey at the same site.

15 GEOTHERMAL ENERGY↗

Application of a dedicated micro-processor for automatic data acquisition of load strain and acoustic-emission data

This paper describes an automatic system for acquisition, logging and analysis of stress, strain and acoustic emission data. The complete system is a combination of several standard items of equipment and a newly developed intelligent data logger which has the capability to send data directly to a large scale computer for reduction and plotting. The data logging and all interfacing with peripheral equipment are accomplished using digital electronics. The heart of the system is a four-bit microprocessor and digital cassette tape unit. The system, which is controlled by instructions from a cathode ray tube terminal, has the capability to transmit data from the cassette unit to a large computer via a time sharing option. Typical results are presented for acoustic emission count rate and total count curves superimposed on stress-strain diagrams for boron/epoxy advanced composites.

Wilson, G. H.↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: METSAT Phase Locked Oscillator Assembly, P/N 1334360-1, S/N's F03 and F04

Two Flight Model AMSU-A Phase Locked Oscillators (P/N 1348360-1, S/Ns F03 and F04) have been tested per AES Test Procedure AE-26758. The tests included vibration testing, thermal cycle testing, AM/FM Noise testing, and full functional testing. EMI/REO 2 Testing was not performed. (See test data for S/N F01). Both AMSU-A Phase Locked Oscillators satisfactorily passed all performance requirements of the AE-26633 Product specification. During thermal cycling of PLO serial number F03, the oven and data logger momentarily lost power, including a loss of data. The unit did not experience any thermal stress. TAR 003134 describes the corrective action. Prior to testing PLO serial number FO4, power was applied to the unit. (+15v,-15v) the unit did not display the proper phase lock. Upon test equipment check out a connector was found to be defective. TAR 003133 describes the corrective action. After completion of testing of PLO serial number F04 was installed into Receiver Assembly F02. Upon testing F02 Receiver Assembly the unit was found not to phase lock at ambient temperature. Removal of PLO Assembly F04 was required. R2 was the real issue. Solithane was secondary. Troubleshooting revealed excessive solithane on inner PLL Assembly cover inhibiting optimum grounding. Also, R2 was reselected which increased the lock range from -30 C to +60 C. TAR 002737 describes the corrective action.

Pines, D.↗

FSA field test

The 12 continental remote sites were decommissioned. Testing was consolidated into a five-site network consisting of the four Southern California sites and a new Florida site. 16 kW of new state-of-the-art modules were deployed at the five sites. Testing of the old modules continued at the Goldstone site but as a low-priority item. Array testing of modules is considered. Additional new testing capabilities were added. A battery-powered array data logger is discussed. A final set of failure and degradation data was obtained from the modules.

Jaffe, P.↗

CT and Geophysical Data of Clinton Sandstone Cores from Ohio

Collection of computed tomography and multi-sensor core logger data of 12 wells in Ohio that intersect the Clinton Sandstone formation. This data is described along with well information in a technical report series document: Paronish, T.; Holleran, A.; Pohl, M.; Crandall, D.; Jarvis, K.; Workman, S.; Drosche, J.; McKisic, T.; Collins, C.; Thomas, M.; McDonald, J. Computed Tomography Scanning and Geophysical Measurements of the Clinton Sandstone in Ohio; DOE.NETL-2025.4949; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory, Morgantown, WV, 2025; p 68. https://doi.org/10.2172/2589262

AS↗

Real-Time Monitoring of Fracture Dynamics with a Contrast Agent-Assisted Electromagnetic Method

In collaboration with the Advanced Energy Consortium, our team has previously demonstrated that the placement of electrically active proppants (EAPs) in a hydraulic fracture surveyed by electromagnetic (EM) methods can enhance the imaging of the stimulated reservoir volumes during hydraulic fracturing. That work culminated in constructing a well-characterized EAP-filled fracture anomaly at the Devine field pilot site (DFPS). In subsequent laboratory studies, we observed that the electrical conductivity of our EAP correlates with changes in pressure, salinity, and flow. Thus, we postulated that the EAP could be used as an in-situ sensor for the remote monitoring of these changes in previously EAP-filled fractures. This paper presents our latest field data from the DFPS to demonstrate such correlations at an intermediate pilot scale. We conducted surface-based EM surveys during freshwater (200 ppm) and saltwater (2,500 ppm) slug injections while running surfaced-based EM surveys. Simultaneously, we measured the following: 1) bottomhole pressure and salinity in five monitoring wells; 2) injection rate using high-precision data loggers; 3) distributed acoustic sensors in four monitoring wells; and 4) tiltmeter data on the survey area. We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, by comparing the electrical field traces with the bottomhole pressure, flow rate, and salinity, we concluded that the observed electric field in our study is influenced by fracture dilation and flow rate. Salinity effect was observed when saltwater was injected. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce all of the measured electric field magnitudes. Preliminary estimates showed that including streaming potential in our geophysical model may be needed to reduce the simulation mismatch. The methods developed and demonstrated during this study will lead to a better understanding of the extent of fracture networks, formation stress states, fluid leakoff and invasion, characterizations of engineered fracture systems, and other applications where monitoring subsurface flow tracking is deemed important.

02 PETROLEUM↗

A microprocessor controlled pressure scanning system

A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.

Anderson, R. C.↗

A microprocessor controlled pressure scanning system

A microprocessor-based controller and data logger for pressure scanning systems is described. The microcomputer positions and manages data from as many as four 48-port electro-mechanical pressure scanners. The maximum scanning rate is 80 pressure measurements per second (20 ports per second on each of four scanners). The system features on-line calibration, position-directed data storage, and once-per-scan display in engineering units of data from a selected port. The system is designed to be interfaced to a facility computer through a shared memory. System hardware and software are described. Factors affecting measurement error in this type of system are also discussed.

Anderson, R. C.↗

BOREAS RSS-17 Stem, Soil, and Air Temperature Data

The BOREAS RSS-17 team collected several data sets in support of its research in monitoring and analyzing environmental and phenological states using radar data. This data set consists of tree bole and soil temperature measurements from various BOREAS flux tower sites. Temperatures were measured with thermistors implanted in the hydroconductive tissue of the trunks of several trees at each site and at various depths in the soil. Data were stored on a data logger at intervals of either 1 or 2 hours. The majority of the data were acquired between early 1994 and early 1995. The primary product of this data set is the diurnal stem temperature measurements acquired for selected trees at five BOREAS tower sites. The data are provided in tabular ASCII format. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Zimmerman, Reiner↗

Exposure of Plant Seeds to the Space Environment Outside the International Space Station

Crop seeds may prove to be a vital component of future long-term spaceflight missions, and the impacts of extended exposure on seed degradation is not well understood. The MISSE-Seed project was designed to investigate the effects of space exposure on seed quality and storage. The project also served as a test of biological materials aboard the Materials International Space Station Experiment (MISSE) platform, and evaluated the capability of a newly designed passive sample containment vessel for the provision of acceptable storage conditions for seed and other biological samples to be preserved upon exposure to the space environment outside the ISS. MISSE-Seed was launched to the ISS on NG-15 in July of 2021 and returned to Earth aboard SpX-24 after approximately 8 months of exposure to the space environment. The specimens consisted of eleven seed varieties (Lettuce, Scarlet Frills, Amara, Garnet Giant, Pac Choi, Radish, Mizuna, Tomato, Cauliflower, Pepper, and Arabidopsis). Data-loggers and thermoluminescent dosimeters (TLDs) were included in each container to record environmental data. Temperature profiles and radiation/UV exposure data were also provided by Aegis Aerospace, the MISSE Implementation Partner. Hardware and experimental design, environmental profiles, and post-flight germination and growth results will be presented.

Alexander D Meyers↗