Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dehumidification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Internally cooled membrane-based absorber for dehumidification and water heating: Validated model and simulation study

This report presents a comprehensive model for advanced membrane-based absorber components accounting for three separate fluid streams, one of them providing internal cooling, with complex flow patterns. The model was implemented with various liquid desiccants and their properties (including LiCl, CaCl 2 , and [emim][OMS] ionic liquid [IL]). The model has been validated using data from two laboratory prototype absorbers, one with CaCl 2 as the working fluid and one with an IL as the working fluid. Entropy analysis was further carried out to verify the model and understand effect of internal cooling on the entropy variation of three fluid streams. The developed model and codes are expected to enable detailed configuration optimization and provide in-depth understanding of three-fluid heat and mass exchanger (HMX) performance. The paper also describes parametric studies of the HMX components in utilizing the latent heat removed in space cooling to heat water and numerically explores the unique benefit of its application in a semi-open absorption heat pump water heater. The results show that a single three-fluid HMX has the potential to achieve simultaneous dehumidification and water heating efficiently at cost effectiveness, particularly in hot and humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat pipes for terrestrial applications in dehumidification systems

A novel application of heat pipes which greatly enhances dehumidification performance of air-conditioning systems is presented. When an air-to-air heat pipe heat exchanger is placed between the warm return air and cold supply air streams of an air conditioner, heat is efficiently transferred from the return air to the supply air. As the warm return air precools during this process, it moves closer to its dew-point temperature. Therefore, the cooling system works less to remove moisture. This paper discusses the concept, its benefits, the challenges of incorporating heat pipes in an air-conditioning system, and the preliminary results from a field demonstration of an industrial application.

Khattar, Mukesh K.↗

Evaporative Cooling and Dehumidification Garment for Portable Life Support Systems

This paper describes the design and development of an innovative thermal and humidity control system for future space suits. The system comprises an evaporation cooling and dehumidification garment (ECDG) and a lithium chloride absorber radiator (LCAR). The ECDG absorbs heat and water vapor from inside the suit pressure garment, while the LCAR rejects heat to space without venting water vapor. The ECDG is built from thin, flexible patches with coversheets made of non-porous, water-permeable membranes that -enclose arrays of vapor flow passages. Water vapor from inside the spacesuit diffuses across the water permeable membranes, enters the vapor flow channels, and then flows to the LCAR, thus dehumidifying the internal volume of the space suit pressure garment. Additional water evaporation inside the ECDG provides cooling for sensible heat loads. -The heat released from condensation and absorption in the LCAR is rejected to the environment by thermal radiation. We have assembled lightweight and flexible ECDG pouches from prototypical materials and measured their performance in a series of separate effects tests under well-controlled, prototypical conditions. Sweating hot plate tests at typical space suit pressures show that ECDG pouches can absorb over 60 W/ft of latent heat and 20 W/ft of sensible heat from the pressure garment environment. These results are in good agreement with the predictions of our analysis models.

Izenson, Michael↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling systems utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling system utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Engineered Polymer Architectures for Thermo–Responsive Desiccants in Dehumidification Applications

Humidity control is relevant to many processes in buildings and manufacturing and is responsible for over 600 million tons of CO 2 annually. As such, desiccants that can efficiently remove moisture from air can greatly reduce emissions. A new class of desiccant materials, thermo–responsive desiccants, has been of increased interest in the literature. These materials are generally based on thermo–responsive polymers and exhibit a temperature–dependent isotherm, an attribute that is small in traditional desiccants. In this work, seven key parameters needed to create an effective thermo–responsive polymer desiccant are identified using a combination of modeling and experimental data. Further, it is found that more thermo–responsiveness is not necessarily better for energy efficiency, and that an optimal, “medium” value is desired. Additionally, polymer composition and architecture play key roles in adjusting the seven key parameters. Finally, based on findings from both modeling and experimental work, guidelines on synthesizing future thermo–responsive polymer desiccants are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Corrosion of Metal Alloys in Potassium Acetate Solutions for Liquid Desiccant Dehumidification and Air Conditioning

For commercial buildings, liquid desiccant air conditioners (LDACs) could provide up to 80% energy savings compared to high-efficiency vapor compression AC, but commonly utilized liquid desiccants are highly corrosive. This precludes the use of metallic components, necessitating specialized plastics and thereby driving up cost, weight, and limiting operational temperature and pressure ranges. Less corrosive alternatives are sought. Here, potassium acetate solutions are investigated as less-corrosive alternatives to the chloride salt solutions that are typically used in LDAC systems. Corrosion evaluations for a Cu alloy (C12200) and two Al alloys (Al3003 and Al1100) in both potassium acetate and chloride salt solutions are presented. We show that yearly corrosion rates are lower in potassium acetate solutions by up to three orders of magnitude. Active corrosion behavior is largely absent in potassium acetate solutions but is present in chloride salt solutions. Furthermore, solid corrosion products are observed in chloride salt solutions. Thus, we conclude that potassium acetate is a promising candidate as a less corrosive alternative liquid desiccant for LDAC systems with metallic components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MODELING OF ENHANCED AIR DEHUMIDIFICATION THROUGH ELECTRICALLY CHARGED VAPOR CAPTURING ELECTROSTATIC DROPLETS

This paper investigated the potential of a new electrostatic-based water vapor separation system for humidity control in buildings. The Electrospray Vortical Flow eXchanger (EVFX) consists of small electrically charged water droplets released inside air vortexes to attract water vapor molecules, effectively wiping out the humidity from the air. Larger droplets are then removed at the outer wall of the vortex. If a water molecule is placed in a gradient electric field, such a polar molecule experiences a dielectrophoresis force, which moves the molecules and produces a vapor concentration gradient. When the vapor density exceeds the saturation level, nucleation occurs. A thermodynamic model that captures this phenomenon was described in this paper. Electrosprayed droplets were initially charged close to their maximum electrical charge dictated by the Rayleigh limit; these droplets were used as nucleation centers. The high electric charge decreased the pressure of the vapor, which was in equilibrium with the droplets. This enhanced the charged droplets' nucleation and growth that depleted the vapor phase near the droplets, which was compensated for by the dielectrophoresis flow and diffusion. Significant water vapor condensation was predicted for small droplets at a high electrical charge. Beyond a specific droplet size, while the condensation of water vapor was still theoretically possible, it was somewhat limited because the further growth of the large charged droplets was inhibited due to their high inherent water vapor pressure near the surface. A case study illustrated the potentials and limitation of the EVFX for droplets charged to the Rayleigh limit, for which the effective range of diameters resulted between 10 nm up to few micron.

Morcelli, Stefano↗

Electrostatic Dehumidification

This project undertook an effort to experimentally demonstrate the ability to change the water content of an air volume through electrostatic, non-condensing means. Humid air is primarily a mixture of nitrogen, oxygen, argon, carbon dioxide and water vapor. Water is unique in this mixture because it possesses a relatively strong natural dipole moment. The physics of electrophoresis offers promise that electrostatic forces could be used to compel movement of water molecules, while leaving the other air components un-affected, which could be exploited to cause a concentration gradient of water within an air-stream.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of the application of solar chemical dehumidification system to wind tunnel facilities of NASA Lewis Research Center at Cleveland, Ohio

Energy utilization and cost payback analyses were prepared for proposed modifications. A 50,000 CFM standard compact packaged solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing solar energy and is stored in a storage tank. A steam boiler is provided as a back-up for the solar system. A 50,000 CFM standard compact package solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing a steam boiler and a heat exchanger and is stored in a storage tank.

Source record↗