At least 55 records · Page 3

Business Case Analysis for Digital Safety-Related Instrumentation & Control System Modernizations

This LWRS research seeks to assist in breaking the impasse which has precluded digital safety system upgrades by generating and demonstrating a process and related business case tool to enable a Business Case Analysis (BCA). The purpose of a BCA is to show such upgrades can be economically justified. This BCA methodology first systematically establishes a forecast of expected lifecycle costs for I&C identified for upgrade by: • Definitively bounding the scope of current I&C systems envisioned for upgrade. • Collecting historical labor and material usage data that bound cost contributors related to the systems to be upgraded. • Synthesizing and analyzing the data to establish lifecycle cost forecasts for the current systems. In collaboration with engineers familiar with the attributes of the digital equipment to be used in the upgrade and how it is envisioned to be applied, cost savings categories and expected savings in those categories are then identified and applied using the analysis tools developed for this purpose. The result is an estimate NPV of savings enabled by the upgrade. This includes both direct cost savings (e.g., surveillance labor costs) as well as cost avoidance items (e.g., inventory carrying costs). Finally, when utility-provided digital upgrade costs estimates are included, the resultant BCA provides an NPV for the upgrade project. Development of a useful BCA methodology requires a real-world basis. With the cooperation of Exelon Generation (“Owner”), an Exelon-owned 2-Unit BWR Station (“Station”) was used as the foundation for this research. Exelon is pursuing a digital upgrade of current, first-echelon, safety-related I&C systems at these units, including the following: • Reactor Protection System (RPS) • Nuclear Steam Supply Shutoff System (N4S) • Emergency Core Cooling Systems (ECCS) • Anticipated Transient Without Scram (ATWS) Mitigation System

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Achieving Verifiable and High Integrity Instrumentation and Control Systems through Complexity Awareness and Constrained Design. Final Report

While most process control industries have been able to embrace digital Instrumentation and Control (I&C) technology to improve performance, reliability, maintainability, and efficiency of production, the nuclear industry has been relatively slow to adopt digital I&C for safety critical plant functions. There are a variety of reasons for this, but in general the nuclear industry takes a conservative stance that new technologies must mature before adoption. A deeper underlying reason for not fully realizing digital I&C and automation in nuclear power is associated with the complexity that can manifest in software-based systems that is different in nature from the complexity of their analog predecessors. Accordingly, this research pursued the development of innovative architectures and methods to “constrain complexity” to enhance verifiability of digital I&C devices. These constraints can positively impact the reduction of Software Common Cause Failures (SCCF) and other systematic errors. The architectural concept developed in this research effort is called SymPLe. SymPLe is specifically aimed at safety critical functions within Nuclear Power Plants and other critical infrastructure where constraining device complexity to support verifiability and safety case arguments is important. The SymPLe architecture is designed to promote “accessible verification” between OEM/utility engineers and the regulatory agencies who review and license nuclear power plant I&C systems. The major contributions of this work to the nuclear industry are: Demonstration of SymPLe as a viable approach to “complexity aware” I&C systems and Embedded Digital Devices.Comprehensive use of model-based design and engineering to produce verifiable I&C systems for the nuclear industry with clear findings on the usability of model-based engineering. Employ comprehensive use of model-based engineering, testing, and verification in an IEC 61508 workflow in support of design assurance. Gathered evidence of “difficult to find” design flaws found using model-based design and testing methods. Detailed the nature of these SCCFs including where they were introduced, the triggers, and how they were found. Gathered evidence on the synergistic use of practical formal methods and testing and how these methods can be used to significantly increase assurance of reduction and avoidance of design flaws.

Testing↗

Demonstration of the Human and Technology Integration Guidance for the Design of Plant-Specific Advanced Automation and Data Visualization Techniques

Nuclear power continues to be a safe, reliable, and carbon-free electricity generating source for the United States, though the cost of operating and maintaining the current United States nuclear power plant fleet has become uncompetitive with other sources. This gap is attributed to the advent of new digital instrumentation and control technologies that other electricity generating industries are currently leveraging to streamline work and greatly reduce operating, maintenance, and support costs. Digital instrumentation and control systems and control room modernization offers significant opportunities to reduce operating and maintenance costs to ensure the continued operation of the existing United States light-water reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Safety-Related Instrumentation and Control Pilot Upgrade: Initial Scoping Phase Implementation and Lessons Learned

In May 2016, the U.S. Nuclear Regulatory Commission (NRC) staff provided a digital instrumentation and control (I&C) regulatory infrastructure integrated action plan to the NRC for approval. One of the objectives of that plan was to establish a clear regulatory structure with reduced regulatory uncertainty to enable the expanded safe use of digital I&C in commercial nuclear reactors while continuing to ensure safety and security. To achieve this end, the NRC, with collaboration from industry, developed a streamlined License Amendment Request Alternate Review (AR) process for safety-related (SR) digital I&C upgrades. In spite of this effort, the industry has remained reluctant to perform such I&C upgrades because of perceived regulatory and financial risks associated with being the first or an early adopter of the AR process for SR I&C upgrades. The U.S. Department of Energy Light Water Reactor Sustainability Program at the Idaho National Laboratory performed Initial Scoping Phase research to help break this impasse by supporting a SR I&C Pilot Upgrade, working with MPR Associates, ScottMadden Inc., and Exelon Generation. Exelon’s Limerick Generating Station (LGS) was selected as the target for this research. This paper summarizes the Initial Scoping Phase engineering and operations, licensing, and project management activities necessary to bound the scope, schedule, and estimated cost of the project sufficiently to enable utility management authorization of Conceptual Design Phase activities. These efforts and associated products are intended to provide a template to support larger industry efforts to perform similar upgrades as a foundation stone for a digital transformation that will improve plant safety, reliability, and operational performance while lowering plant total cost of ownership. As a result of the combined effort of Exelon Generation and research participants, Conceptual Design Phase activities for the subject upgrade at LGS were approved by Exelon. Further, the U.S. Department of Energy also awarded a $50 million cost share award to Exelon in order to pave the way for SR I&C modernization and associated control room upgrades across the U.S. nuclear fleet. Additional research reports are planned for the Conceptual Design Phase, Detailed Design Phase, and the Implementation Phase of the LGS project to document the process followed and promulgate lessons learned to industry.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Business Case Analysis for Digital Safety-Related Instrumentation & Control System Modernizations

The commercial nuclear sector faces unprecedented financial challenges driven by low natural gas prices and subsidized renewables in a marketplace that does not reward carbon-free baseload capacity. These circumstances, along with increasingly antiquated labor-centric operating models and analog technology, have forced the premature closure of multiple nuclear facilities and placed a much larger population of nuclear power stations at risk. Nuclear plant economic survival in current and forecasted market conditions requires an efficient and technology-centric operating model that harvests the native efficiencies of advanced technology. This is analogous to transformations in nearly every other industry. In light of previous industry experience in modernizing safety Instrumentation and Controls (I&C) systems, nuclear utilities are reluctant to pursue these upgrades due to uncertainty in licensing and cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ergonomic Safety and Health Activities to Support Commercial Nuclear Power Plant Control Room Modernization in the United States

Affordable, abundant, and reliable electricity generation is essential to fueling a nation’s robust and globally competitive economy. In the United States (U.S.), commercial nuclear power plants (NPPs) account for approximately 19% of reliable and cost-competitive baseload electricity generation. Other technologies that reduce reliance on fossil fuels and provide baseload electricity cost-competitively at a national scale are still under development. Thus, without suitable replacements for nuclear power, the generating capacity of nuclear energy in the U.S. must be continued through the safe and efficient operation of commercial NPPs. The U.S. De-partment of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) research and development (R&D) program provides the technical bases for the long-term, safe, and economical operation of NPPs. One area in the LWRS program is the Plant Modernization pathway, which includes human factors R&D, human factors engineering (HFE), and ergonomics to enable the modernization of the instrumentation and control (I&C) technologies in NPP main control rooms (MCRs). DOE researchers, including ergonomics specialists at Idaho National Laboratory (INL) have collaborated with nu-merous commercial NPP utilities over the last few years on control room modernization. This paper summarizes recent ergonomics safety and health R&D and HFE performed in collaboration with a U.S. commercial utility to modernize their NPP MCRs.

99 GENERAL AND MISCELLANEOUS↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NRC technical basis for evaluation of its position on protection against common cause failure in digital systems used in nuclear power plants - 378

Digital technology has advantages over analog systems, including automated monitoring and alerts for standby safety functions, and predictive algorithms to maintain critical safety systems. Additionally, digital technology generally has higher reliability and can be designed to reduce single point vulnerabilities. For these reasons many nuclear plants have applied digital technology to safety and non-safety related applications, including reactor protection system, feedwater and turbine controls, etc. with a corresponding significant improvement in trip reduction. Nonetheless, digital instrumentation and control (I and C) systems also present potential new vulnerabilities that need to be assessed, including potential failures due to increased complexity of digital systems, the introduction of unique failure modes due to software (including software common cause failure (CCF)), and limited operating history of digital systems in nuclear safety related applications compared to analog systems. The fact that software is intangible means that common methods, such as analysis or testing, used for detecting CCF may not be effective when applied to software. Consequently, digital technology is perceived to pose a potential risk from the introduction of undetected systematic faults that could result in CCF. Despite the I and C system upgrades and modifications performed to date, the U.S. Nuclear Regulatory Commission (NRC) and industry stakeholders have identified the need to modernize the regulatory infrastructure to efficiently address risks associated with the use of digital technology for nuclear safety applications and address regulatory uncertainties. The NRC's current position on CCF is guided by the staff requirements memorandum (SRM) on SECY 93-087. The SRM provides specific acceptance criteria for the evaluation of CCF, which the staff implemented in the Branch Technical Position (BTP) 7-19. However, industry stakeholders have proposed using methods to characterize the likelihood of software CCF and eliminate it from further consideration in a defense-in-depth and diversity analysis. The NRC's current position does not consider these alternatives, and thus corresponding acceptance criteria is not currently available. The work discussed in this paper assesses the underlying technical basis associated with CCF, provides technical support for updating the NRC position and considers proposed methods for addressing potential CCF in digital systems while enhancing efficiency, clarity, and confidence. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Graded approach for assessing digital system failure susceptibilities - 305

Owner/operators of nuclear plants must be able to identify and assess susceptibilities to digital system failures and unintended behaviors that could lead to plant system malfunctions, including common-cause failures (CCFs) of multiple controlled components that may impact overall plant safety. Nuclear plant designers and regulators often assess and manage potential failure modes by assuming the failure occurs and showing by analysis that the results are acceptable. In 2016 EPRI published a guideline on Methods for Assuring Safety and Dependability when Applying Digital Instrumentation and Control Systems (EPRI 3002005326), which takes a more holistic approach that considers digital system failure modes from the perspective of their impact on plant risk and includes a graded approach based on safety significance. This paper describes that graded approach. The methodology in EPRI 3002005326 systematically identifies potential I and C vulnerabilities that could lead to significant malfunctions of controlled components and systems, including common-cause failures (CCF), and discusses in detail methods to protect against them. It considers both preventive measures that reduce the likelihood of failures, and plant systems and features that mitigate the effects of component failures and misbehaviors. Coping analysis is then performed as appropriate to provide additional assurance of protection. The safety significance based graded approach is an important feature in that it can help users focus attention on overall plant safety, including potentially risk-significant scenarios that might not be considered in traditional safety analyses. The purpose is to help the user ensure that modifications to the I and C that could potentially be safety significant are treated appropriately and at the same time not waste valuable resources on excessive protection against changes that have little or no impact on safety. The graded approach allows the design engineer to tailor the rigor of the preventive, limiting, and mitigative measures commensurately with the effects the I and C modification has on overall plant safety. The graded approach focuses on safety significance impact, which is effectively a qualitative measure of the potential change in safety (or risk) caused by a proposed I and C modification, as compared to the I and C that is being replaced. Safety significance impact should not be confused with importance to safety or risk significance. It is possible that an upgrade to safety-related and/or risk-significant I and C systems may have little or no safety significant impact and vice versa. The approach considers three factors that influence the impact on safety significance of a proposed I and C modification: context, likelihood of failure, and consequences of failure. The most significant of the three factors is context - what the I and C is connected to, both directly and indirectly, including its potential effects on plant systems that respond to transients or accidents. The graded approach is particularly helpful in assessing potential CCFs resulting from digital I and C failures, and shows why the most problematic CCFs will be those that can affect multiple plant systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Migration to a fully-integrated control room - 349

The nuclear industry is faced with a pressing need to reduce operating costs in order to remain competitive with other forms of electric generation. While current industry initiatives are focused on incremental gains by streamlining work processes and reducing worker burdens, very few, if any, involve significant reductions in the base workload of a nuclear plant. Migration to a fully-integrated control room affords just such an opportunity. This report describes an NPP digital instrumentation and control (I and C) system design, along with its corresponding human systems interface (HSI) design, which achieves high plant availability, while selectively applying digital equipment redundancy and integrating traditional I and C system partitions, to minimize the digital equipment needed, and thereby minimize initial installation costs and ongoing operations and maintenance (O and M) costs. An additional key component of digital equipment minimization is optimization of the digital interface to conventional plant sensors and controlled plant devices (e.g., pumps, valves), which requires no disturbance to plant cables and results in eliminating thousands of electro-mechanical relay control components. The design is rooted in the highly integrated digital technology applied to the most recent advanced light water reactors under United States (U.S.) Nuclear Regulatory Commission (NRC) design certification review and approval. While this design employs technology from new plants, that technology has been adapted to the modernization of current operating NPPs. Hence, the highly integrated digital I and C and HSI design is referred to as the compact control room digital modernization (CDM). Along with minimal digital equipment, the corresponding HSI design employs compact operator workstations with visual display units (VDU) and soft controls for both the main control room (MCR) and remote shutdown room (RSR), to immediately improve human performance and ultimately facilitate operating staff reduction. Some advanced light water reactors have demonstrated this staff reduction through full scope simulator testing of normal and abnormal plant conditions, with U.S. licensed operating crews from currently-operating U.S. plants. Digital equipment minimization, compact operator workstations, and optimized plant component interfaces that require no disturbance to field cables, also facilitate implementation of the CDM over multiple phases, most of which can be conducted during normal refueling shutdown windows. This phased implementation method includes a novel transition of the I and C, MCR and RSR with an operations centered focus. This paper presents the CDM design, along with qualitative cost/benefit comparisons to currently operating plants with conventional analog I and C and HSI technology; this generation of I and C/HSI is referred to as a conventional control room (CCR). A CCR also includes NPPs that have been upgraded with digital systems, but retain the current partitions between plant I and C systems (i.e., no I and C integration) and retain the current plant system to control board configuration of current NPP control rooms. Even though these comparisons are qualitative, a compelling case is presented for the CDM. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

BWR modernization project: installation of a new digital feedwater control system - 295

A European BWR plant carried out a relevant and pioneering modernization project regarding the Feedwater and Feed Pump Turbine Control System, replacing the legacy analogic control with the new General Electric MarkVIe digital system. This digital instrumentation and control modernization, motivated by obsolescence, had a great impact on the main control room and on the plant operation. Tecnatom collaborated with the nuclear power plant in the project performing the following activities: early installation of the system in the full scope and classroom simulators, Human Factors Engineering (HFE) Verification and Validation (V and V), Simulation Assisted Engineering (SAE), design and implementation of cyber secure communication with the Plant Process Computer (PPC), operating procedures modification and plant operators training. Those activities contributed to the success of the project that was completed during the refueling outage as planned. Scheduling HFE verification before the design freeze allowed the plant to modify the Human Machine Interface (HMI) to comply with the standards and increase safety without overcharging the project. SAE resulted in the reduction of costs and time during the system commissioning through the detection of discrepancies and improvements in the control, covering different plant scenarios. All the activities carried out in the simulators before the implementation of the system in the plant contributed to validate it and to build confidence in the new control among the plant personnel. New digital system communication interfaces with the PPC saved cable laying works and allowed future expansions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Technical Specification Surveillance Interval Extension Using Self-Diagnostics

As part of the Light Water Reactor Sustainability program, an ongoing research effort is being conducted on technical specifications surveillance interval extension of digital equipment in nuclear power plants. The research team is led by Idaho National Laboratory and includes Pacific Northwest National Laboratory, Technology Resources, and Oak Ridge National Laboratory. This research focuses on developing methods for applying the U.S. Nuclear Regulatory Commission (NRC)–approved guidance to implement a licensee-controlled, risk-informed surveillance frequency change program in digital instrumentation and control (I&C) systems that include self-diagnostics and online monitoring (OLM) capabilities. Although approved methods exist for extending technical specifications (TS) surveillance test intervals (STIs) for general equipment, including analog I&C equipment, gaps remain in technology and guidance on crediting newer digital equipment’s internal self-diagnostics and OLM characteristics. Previous research described a general methodology for crediting internal self-diagnostics for extending surveillance test intervals. The methodology used self-diagnostics to detect—and credited recovery from—failure. Self-diagnostics were also applied for performance monitoring during the extended surveillance interval. This report discusses the status of recent activities to evaluate the previously developed methodology using a pilot study. Although both a utility partner for a pilot study and a specific digital asset were identified in FY2020, delays in obtaining proprietary information resulted in a limited ability to fully evaluate the methodology, and further interactions were complicated by the COVID pandemic. Therefore, at that time, the use of public-domain information—along with current processes for surveillance interval extension through a surveillance frequency control program—identified the need to fully assess diagnostic coverage as part of the pilot study. Furthermore, self-diagnostics were also identified as a potential option to replace the drift analyses conducted as part of current STI extension procedures. In FY2022, the project was reconstituted with the industry partner, and information and data were made available by the industry partner to the research team for review. The shared information included failure event descriptions and data for a digital I&C system since its implementation, as well as recent STI extension interval reports developed by the utility partner on that digital I&C system. This report presents an evaluation of this information and data and describes an application of the proposed methodology cited above. The methodology seeks to take advantage of the self-diagnostics and OLM capabilities to reduce risk or reduce the level of qualitative monitoring assessment needed to perform a risk-informed STI extension using existing NRC approved guidance or both. Addressing these issues of STI extension by crediting self-diagnostics is likely to result in benefits for current and future nuclear power plant (NPP) operations, including lowering the barriers to adoption of digital I&C systems and increasing cost savings by deferring or eliminating unneeded preventive maintenance (tasks or checks or activities). Specifically, self-diagnostic and OLM capabilities of newer digital equipment being installed in non-safety and safety applications are designed to detect failures, provide early warning of potential failures, and notify plant operators to take appropriate action to reduce out of service (OOS) time thus protecting safety margins. Moreover, the equipment is expected to provide information that time-related operational degradation is identified early to ensure timely and planned corrective actions instead of a reactive and unplanned approach ahead of an extended-surveillance interval.

42 ENGINEERING↗

Preliminary Cyber-Informed Dynamic Branch Conditions for Analysis with the Dynamic Simplified Cyber MELCOR Model

Instrumentation and control of nuclear power is transforming from analog to modern digital assets. These control systems perform key safety and security functions. This transformation is occurring in new plant designs as well as in the existing fleet of plants as the operation of those plants is extended to 60 years. This transformation introduces new and unknown exploits involving both digital asset induced safety issues and security exploits. Traditional the open literature of nuclear power risk assessment tools and cyber security assessment methods have not been modified or developed to address the unique nature of cyber failure modes and of cyber security threats. Starting in 2015, Sandia National Laboratories (SNL) embarked on a two year dynamic cyber-risk informed project to facilitate the analysis of unique cyber failure modes and the time sequencing of cyber faults, both malicious and non-malicious, and impose those cyber exploits and cyber faults onto a nuclear power plant accident sequence simulator code to assess how cyber exploits and cyber faults could interact with a plant's digital instrumentation and control (DI and C) system in the absence of digital controls. This will be achieved by coupling SNL's existing dynamic scheduler code (ADAPT), nuclear accident simulator code (MELCOR), and cyber Emulytics code (SCEPTRE) to demonstrate real-time simulation of cyber exploits and their impact on automatic DI and C responses. Studying such potential time-sequenced cyber-attacks and their risks (i.e., the associated impact and the associated degree of difficulty to achieve the attack vector) as they pertain to accident management will provide a risk informed basis for developing effective cyber security controls for nuclear power. This paper will discuss the rationale behind the proposed generic cyber exploits for an abstracted Pressurized Water Reactor that has adopted a unified DI and C System. Other papers related to this project submitted to this conference discuss: - The MELCOR model for this abstracted reactor, called the Dynamic Simplified Cyber (DSC) model, - Modifications to ADAPT to: Extend the framework for multiple simulators, Incorporation of importance measures into dynamic event tree analysis, Sort and reduce the dynamic event tree based upon inputs to or outputs from the tree, and - A feasibility study for using density based clustering methods with dynamic time wrapping to cluster and prune dynamic event trees. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cybersecurity Vulnerability Assessment Methodologies for Nuclear Power Plants

As any mechanical system ages, broken or outdated parts must be replaced; nuclear power plants (NPPs) are no different. The average age of a NPP in the United States' aging fleet of commercial reactors is 35 years, with many of these plants operating under extensions of their original licenses. These plants, originally designed in the 1960's and 1970's, are controlled by analog instrumentation and control (I and C) systems, and have since been upgraded (to varying degrees) to hybrid analog-digital systems. As these NPPs are upgraded to continue operating and to meet more stringent safety requirements imposed by the Nuclear Regulatory Commission (NRC), the implementation of digital systems to monitor and run the power plant introduces new vulnerabilities that must be addressed. The main objectives of a vulnerability assessment (VA) are to identify, quantify, and prioritize all of the susceptibilities inherent in a system. This allows for all weaknesses to be analyzed, and for the most serious concerns to be addressed first. Traditional VA methodologies deal with the analysis of physical systems associated with the NPP; with the introduction of digital control systems and computer networks, these methodologies must be expanded to include these fundamentally different systems and vulnerability concerns. Digital systems have been used in NPPs since the 1980's, but only for non-safety control systems; attacks on these systems were not deemed consequential, and no dedicated VA methodology was required. However, 'all new NPPs are being designed with integrated digital instrumentation and control systems as the backbone of protection, controls, alarms, and display and monitoring'. This gives rise to new vulnerabilities such as disrupted data displays, the suppression of critical alarms, or unauthorized access to secure systems from connected networks. The NRC released formal cybersecurity regulations in March 2009 (10 CFR 73.54), as well as a guide for the program in January 2010 (RG 5.71). However, the regulations and guide provide limited insight on how to identify these vulnerabilities; the focus is on remediating them once found. Hence, there is a need for a comprehensive, systematic methodology to conduct a VA on digital computer and communications and network systems. In this paper, we review traditional VA methodologies and discuss relevant cases. Then we discuss challenges to vulnerabilities within the context of modernization of the fleet and what needs to be done to address this issue.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Integrated Hazard Analysis for Digital Reactor Trip Systems

Digital instrumentation and control (I&C) upgrades are a vital research area for nuclear industry. Despite their performance benefits, deployment of digital I&C in nuclear power plants (NPPs) has been limited. Digital I&C systems exhibit complex failure modes including common cause failures (CCFs) which can be difficult to identify. This paper describes the development of a redundancy-guided application of the Systems-Theoretic Process Analysis (STPA) and Fault Tree Analysis (FTA) for the hazard analysis of digital I&C in advanced NPPs. The resulting Redundancy-guided System-theoretic Hazard Analysis (RESHA) is applied for the case study of a representative state-of-the-art digital reactor trip system. The analysis qualitatively and systematically identifies the most critical CCFs and other hazards of digital I&C systems. Ultimately, RESHA can help researchers make informed decisions for how, and to what degree, defensive measures such as redundancy, diversity, and defense-in-depth can be used to mitigate or eliminate the potential hazards of digital I&C systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Model Agnostic Reliability Evaluation of Machine-Learning Models Integrated in Instrumentation & Control Systems

In recent years, the field of machine learning (ML), specifically neural networks, has grown significantly and has spurred research in its applicability to digital instrumentation and control systems (DI&C). While ML models have shown promise in operational contexts, the trustworthiness of using such algorithms has not been adequately assessed. Failures of ML integrated systems are not well understood, and the lack of comprehensive risk modeling can degrade the trustworthiness in these systems. In recent reports by the National Institute for Standards and Technology (NIST) [1] and the Nuclear Regulatory Commission (NRC) [2], they indicate that trustworthiness in ML is a critical barrier and will play a vital role in the safe, accountable, and secure operation of intelligent systems. Thus, in this work, we demonstrate a dynamic model-agnostic method to quantify the relative reliability of AI/ML predictions by incorporating out-of-distribution (OOD) detection on the training dataset. It is well documented that most ML algorithms excel at interpolation (or near-interpolation) tasks but experience significant performance degradation at extrapolation. The method, referenced as the Laplacian distributed decay for reliability (LADDR), determines the difference between the operational and training datasets which can used to the relative reliability of AI/ML predictions. LADDR is then demonstrated on a feedforward neural network based digital twin used for the prediction of safety significant factors during a loss-of-flow transient. LADDR is used to demonstrate how training data can be used as evidence to support the relative reliability of ML/AI predictions enhancing the overall trustworthiness of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview and Recommendations for Cyber Risk Assessment in Nuclear Power Plants

Digital instrumentation and control (I&C) systems are being deployed in nuclear power plants (NPPs) for both existing and advanced reactor designs. As I&C systems become more digitized to allow features like near autonomous control and remote operation, they introduce greater cyber risk to NPPs. Cyberattacks targeting industrial control systems (ICSs) are growing in both qualities and capabilities, which indicates that cybersecurity needs to be an integral part of risk assessment in the industry. Although there are some risk assessment methods in traditional information technology (IT) cybersecurity, the differences between IT and ICS cybersecurity make it infeasible to apply these risk assessment methods directly to ICSs. Some research has focused on risk assessment methods for ICSs, but few studies focus on applications to NPPs. Ideal risk frameworks for the nuclear industry are dynamic and account for system dependencies; this survey review focuses on such risk assessment methods both in and outside the nuclear field. In this article, the major challenges in cybersecurity risk assessment research are pointed out, and further research suggestions and considerations for cyber risk assessment in I&C systems are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Statistical Testing Approach for Quantifying Software Reliability; Application to an Example System

The U.S. Nuclear Regulatory Commission (NRC) encourages the use of probabilistic risk assessment (PRA) technology in all regulatory matters, to the extent supported by the state-of-the-art in PRA methods and data. Although much has been accomplished in the area of risk-informed regulation, risk assessment for digital systems has not been fully developed. The NRC established a plan for research on digital systems to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems in the PRAs of nuclear power plants (NPPs), and (2) incorporating digital systems in the NRC's risk-informed licensing and oversight activities. Under NRC's sponsorship, Brookhaven National Laboratory (BNL) explored approaches for addressing the failures of digital instrumentation and control (I and C) systems in the current NPP PRA framework. Specific areas investigated included PRA modeling digital hardware, development of a philosophical basis for defining software failure, and identification of desirable attributes of quantitative software reliability methods. Based on the earlier research, statistical testing is considered a promising method for quantifying software reliability. This paper describes a statistical software testing approach for quantifying software reliability and applies it to the loop-operating control system (LOCS) of an experimental loop of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗