Search NASA⌕ Search

SEARCH · Search NASA

Results for “Double shell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Direct-drive double-shell implosion: A platform for burning-plasma physics studies

Double-shell ignition designs have been investigated with the indirect-drive inertial confinement fusion (ICF) scheme in both simulations and experiments in which the inner-shell kinetic energy was limited to ~10 to 15 kJ, even driven by megajoule-class lasers such as the National Ignition Facility. Since direct-drive ICF can couple more energy to the imploding shells, we have performed a detailed study on direct-drive double-shell (D 3 S) implosions with state-of-the-art physics models implemented in radiation-hydrodynamic codes (LILAC and DRACO), including nonlocal thermal transport, cross-beam energy transfer (CBET), and first-principles-based material properties. To mitigate classical unstable interfaces, we have proposed the use of a tungsten/beryllium–mixed inner shell with gradient-density layers that can be made by magnetron sputtering. In our D 3 S designs, a 70-μm-thick beryllium outer shell is driven symmetrically by a high-adiabat (α ≥ 10), 1.9-MJ laser pulse to a peak velocity of ~240 km/s. Upon spherical impact, the outer shell transfers ~30 to 40 kJ of kinetic energy to the inner shell filled with deuterium–tritium gas or liquid, giving neutron-yield energies of ~6 MJ in 1-D simulations. Two-dimensional high-mode DRACO simulations indicated that such high-adiabat D 3 S implosions are not susceptible to laser imprint, but the long-wavelength perturbations from the laser port configuration along with CBET can be detrimental to the target performance. Yet, neutron yields of ~0.3- to 1.0-MJ energies can still be obtained from our high-mode DRACO simulations. The robust α-particle bootstrap is readily reached, which could provide a viable platform for burning-plasma physics studies. Once CBET mitigation and/or more laser energy becomes available, we believe that breakeven or moderate energy gain might be feasible with the proposed D 3 S scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hohlraum-Driven Mid-Z (SiO{sub 2}) Double-Shell Implosions on the Omega Laser Facility and Their Scaling to NIF

High-convergence, hohlraum-driven implosions of double-shell capsules using mid-Z (SiO{sub 2}) inner shells have been performed on the OMEGA laser facility [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)]. These experiments provide an essential extension of the results of previous low-Z (CH) double-shell implosions [P. A. Amendt et al., Phys. Rev. Lett. 94, 065004 (2005)] to materials of higher density and atomic number. Analytic modeling, supported by highly resolved 2D numerical simulations, is used to account for the yield degradation due to interfacial atomic mixing. This extended experimental database from OMEGA enables a validation of the mix model, and provides a means for quantitatively assessing the prospects for high-Z double-shell implosions on the National Ignition Facility [Paisner et al., Laser Focus World 30, 75 (1994)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CT analysis of double shell targets

We are more accurately determining the initial conditions of our double shell targets used for ICF: Fusion has the capability to provide clean, safe energy; We are studying double shell capsules to determine if ignition is possible; We have taken CT scans of the initial target and analyzed these scans for roundness; We are developing a method to analyze these scans.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hanford Double-Shell Tank Extent-of-Condition Construction Review

During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. The formal leak assessment, documented in RPP-ASMT-53793,Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure. To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records were performed for the first three DST tank farms constructed, which included tanks 241-AY-101, 241-AZ-101, 241-AZ-102, 241-SY-101, 241-SY-102, and 241-SY-103. The review for these six tanks involved research and review of dozens of boxes of historical project documentation. These reviews form a basis to better understand the current condition of the three oldest Hanford DST farms. They provide a basis for changes to the current tank inspection program and also provide valuable insight into future tank use decisions. If new tanks are constructed in the future, these reviews provide valuable "lessons-learned" information about expected difficulties as well as construction practices and techniques that are likely to be successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Double-Shell Tank Extent-of-Condition Review - 15498

During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. A formal leak assessment, documented in RPP-ASMT-53793, Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure.1 To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records was performed for Hanford’s remaining twenty-seven DSTs. Review involved research of 241 boxes of historical project documentation to better understand the condition of the Hanford DST farms, noting similarities in construction difficulties/issues to tank AY-102. Information gathered provides valuable insight regarding construction difficulties, future tank operations decisions, and guidance of the current tank inspection program. Should new waste storage tanks be constructed in the future, these reviews also provide valuable lessons-learned.

Johnson, J. M.↗

Hanford double-shell tank extent-of-condition construction review - 15498

During routine visual inspections of Hanford double-shell waste tank 241-AY-102 (AY-102), anomalies were identified on the annulus floor which resulted in further evaluations. Following a formal leak assessment in October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of AY-102 was leaking. A formal leak assessment, documented in RPP-ASMT-53793, Tank 241-AY-102 Leak Assessment Report, identified first-of-a-kind construction difficulties and trial-and-error repairs as major contributing factors to tank failure. To determine if improvements in double-shell tank (DST) construction occurred after construction of tank AY-102, a detailed review and evaluation of historical construction records was performed for Hanford's remaining twenty-seven DSTs. Review involved research of 241 boxes of historical project documentation to better understand the condition of the Hanford DST farms, noting similarities in construction difficulties/issues to tank AY-102. Information gathered provides valuable insight regarding construction difficulties, future tank operations decisions, and guidance of the current tank inspection program. Should new waste storage tanks be constructed in the future, these reviews also provide valuable lessons-learned.(authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining Drying Conditions to Mitigate Hanford Double Shell Storage Tank Underside Corrosion — Phase 1

The Hanford Site in Washington State has legacy radiological waste that is being retrieved from single shell tanks (SSTs) and transferred to newer, double shell tanks (DSTs) for eventual closure of the SSTs. The waste is maintained in the DSTs until eventual immobilization can be performed at the Waste Treatment and Immobilization Plant (WTP), currently under construction. Until full immobilization is complete, extended service of the DSTs must be ensured by mitigating corrosion of the steel tank walls and buried steel pipelines. A Pit Air Supply System has been developed to mitigate corrosion of the leak detection pits connected to the concrete foundations of the DSTs. The objectives for the present study are: (i) to corrode steel specimens in an electrolytic simulant to form artificial pits with specific pit depths, and (ii) to determine the temperature and humidity levels that will mitigate further pit growth. Experimental work and results will be presented to evaluate conditions associated with the PASS system and predict corrosion rates when the PASS is operating.

Atmospheric Corrosion↗

Postshot report for double shell 2-axis keyhole NIF experiment N210224-001 [Slides]

The goal of this experiment is to measure preheat and shock symmetry in a double shell capsule. The campaign objective is to assess preheat and shock symmetry in high-Z double shells, and the shot objective is to measure preheat motion to ~0.2 km/s and shock breakout symmetry to ~100 ps.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Double-shell FY2022, Q4 L2 milestone on low-to-mid mode inner shell shape (MRT 7472)

This report summarizes an extensive series of numerical simulations, which have been performed to assess the performance sensitivity of double shell implosions to low (1-4) and midmode (16-200) perturbations on all interfaces of the double shell capsule. This work was performed to satisfy the L2 milestone, the text and completion criteria of which are summarized in Sections 2 and 3 of this report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

P-n heterostructured TiO2/NiO double-shelled hollow spheres for the photocatalytic degradation of papermaking wastewater

Highlights: • P-n heterostructured TiO{sub 2}/NiO double-shelled hollow spheres were prepared. • A cubic-structured NiO layer is grown on surface of anatase TiO{sub 2} hollow sphere. • TiO{sub 2}/NiO show high photocatalytic activity for papermaking wastewater degradation. • The COD{sub Cr} removal rate of wastewater reaches 98.1% after 6 h of photodegradation. - Abstract: P-n heterostructured TiO{sub 2}/NiO double-shelled hollow spheres were prepared through sol–gel and hydrothermal processes. TiO{sub 2}/NiO nanomaterials were comprehensively characterized, and the results reveal that a cubic-structured NiO layer is successfully grown on the surface of the anatase TiO{sub 2} hollow sphere to achieve a p-n heterostructure. The thickness of TiO{sub 2} shell is ∼20 nm, and that of NiO shell is 10–25 nm. Compared with the pure TiO{sub 2} hollow spheres, the prepared p-n heterostructures display a considerably higher photocatalytic activity for papermaking wastewater degradation under UV light irradiation. The chemical oxygen demand removal rate of papermaking wastewater reaches 98.1% after 6 h of photodegradation with DSTN2 as the photocatalyst. The enhanced photocatalytic activity is due to the synergetic effects of p-n heterostructures and the large specific surface area of the catalyst; these effects may promote the separation of photogenerated electron–hole pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inspection Technology Advancements for Hanford Double Shell Tank Integrity Verification - 16150

The Hanford double-shell tanks (DSTs) were constructed in southeastern Washington State between 1968 and 1986 to store nuclear waste. Most of the tank waste came from the Hanford nuclear weapons program, which has been stopped for more than 25 years. The tanks will be needed for many years to come until suitable vitrification and permanent storage solutions are developed. These tanks are nominally 45 ft. deep from the dome peak to the floor. The inner tank is nominally 75 ft. dia. and the outer tank is nominally 80 ft. dia., leaving a 2.5 ft. annulus between the two side tank walls. The waste management program (under direction of Washington River Protection Solutions, WRPS) manages inspections of these DSTs from the annulus to justify their continued safe service and to avoid the high cost of new replacement tanks. Over time, the Hanford Tank Farm contractors, currently WRPS, have increased their ultrasound inspections of these tanks. Pacific Northwest National Laboratory has worked with the Hanford Tank Farm contractors for more than 15 years to advance applicable tank nondestructive inspection technology for improved performance and cost reduction. Past, present, and planned technology advancements are addressed in this paper, including tank wall ultrasonic testing examination, extreme value statistical analysis, phased array for the tank wall, transmit/receive tandem synthetic aperture focusing technique knuckle examination, and electromagnetic acoustic transducer screening of the tank wall including mill-scale compensation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single and Double Shell Ignition Targets for the National Ignition Facility at 527 nm

Converting and using the National Ignition Facility (NIF) to deliver 527 nm light instead of its current 351 nm would allow the laser to deliver more energy and power to ignition targets. We update previous 527 nm target design work to reflect more contemporary target designs using high-density carbon capsules and low density helium gas filled Hohlraums. We extend single shell capsule designs based on current experimental results to higher energy and power and also explore double shell capsules, both driven by green light. These studies were completed using detailed pulse shapes found for targets that converged with acceptable 2D implosion symmetries and then used the Lava Lamp II code to confirm their feasibility at NIF. A 1.2× dimensional scaleup of one tuned NIF target at the limit of its current 351 nm capabilities and shot 170827 uses 3.3 MJ, at the limit of the current NIF's 527 nm capability. With the less-structured pulse of a double shell target, 3.7 MJ could be delivered by the laser. Our LPI calculations do not preclude operation at 527 nm, particularly for low fill Hohlraums, and suggest that the stimulated Raman backscatter may be no worse than the small quantities seen in 170827; stimulated forward Raman scattering may be present. If Stimulated Brillouin Scattering is too great, the much greater laser bandwidth available at 527 nm could be used to decrease backscatter. These larger targets with higher energy and power may offer a better chance of achieving ignition with only modest changes to the NIF laser.

43 PARTICLE ACCELERATORS↗

A comparison of past and present computational methods for shape analysis of double-shell x-ray radiographs

Implosion symmetry is a key requirement in achieving a robust burning plasma in inertial confinement fusion experiments. In double-shell capsule implosions, we are interested in the shape of the inner shell as it pushes on the fuel. Shape analysis is a popular technique for studying said symmetry during implosion. Combinations of filtering and contour-finding algorithms are studied for their promise in reliably recovering Legendre shape coefficients from synthetic radiographs of double-shell capsules with applied levels of noise. A radial lineout max(slope) method when used on an image pre-filtered with non-local means and a variant of the marching squares algorithm are able to recover p 0 , p 2 , and p 4 maxslope Legendre shape coefficients with mean pixel discrepancy errors of 2.81 and 3.06, respectively, for the noisy synthetic radiographs we consider. Here, this improves upon prior radial lineout methods paired with Gaussian filtering, which we show to be unreliable and whose performance is dependent on input parameters that are difficult to estimate.

47 OTHER INSTRUMENTATION↗

Progress Report on the Investigation of Separable Floating Layers in Hanford Double-Shell Tank Supernates

A review of studies performed the last four years at 222-S Laboratory on separable floating solids including demonstration of the formation of a floating layer in the organic-bound simulated solids and investigation of floating solids found in AN-101 and AW-104 as well as carbonate precipitation floating on the surface of AN-107 grab samples. Demonstrated that semivolatile organic analysis can detect separable organics including tributyl phosphate, degradation products of Quintolubric hydraulic fluid, and hydrocarbon as tentatively identified compounds. In addition, an evaluation of the relationship of small organic acids to the total organic carbon is discussed in selected double-shell tank supernate. A systematic approach is presented to monitor separable organics and insoluble particulates in the double-shell tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Discovery of the First Leaking Double-Shell Tank - Hanford Tank 241-AY-102

A routine video inspection of the annulus space between the primary tank and secondary liner of double-shell tank 241-AY-102 was performed in August 2012. During the inspection, unexpected material was discovered. A subsequent video inspection revealed additional unexpected material on the opposite side of the tank, none of which had been observed during inspections performed in December 2006 and January 2007. A formal leak assessment team was established to review the tank's construction and operating histories, and preparations for sampling and analysis began to determine the material's origin. A new sampling device was required to collect material from locations that were inaccessible to the available sampler. Following its design and fabrication, a mock-up test was performed for the new sampling tool to ensure its functionality and capability of performing the required tasks. Within three months of the discovery of the unexpected material, sampling tools were deployed, material was collected, and analyses were performed. Results indicated that some of the unknown material was indicative of soil, whereas the remainder was consistent with tank waste. This, along with the analyses performed by the leak assessment team on the tank's construction history, lead to the conclusion that the primary tank was leaking into the annulus. Several issues were encountered during the deployment of the samplers into the annulus. As this was the first time samples had been required from the annulus of a double-shell tank, a formal lessons learned was created concerning designing equipment for unique purposes under time constraints.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reaction-in-flight neutrons as a diagnostic for hydrodynamical mixing in double shell inertial confinement fusion capsules

We examine reaction-in-flight (RIF) neutrons as diagnostics for hydrodynamical mixing of high-Z shell material into the hotspot of double shell capsules that are designed for the National Ignition Facility. In particular, we consider the effects of different levels of mixing of tungsten shell material into the DT gas on RIF spectra. Using a set of 1D simulations from the radiation hydrodynamic code xRAGE to determine the temperature and density profiles of the mixed W-DT gas, we find that increasing the mass of mix systematically reduces the ratio of RIF neutrons to primary 14 MeV neutrons. The shape of the RIF spectrum also changes with mix, with the predicted spectrum softening in energy with increasing mix.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technology Development for Under Tank Inspection of Double-Shell Tanks - 20045

The Department of Energy (DOE) Office of River Protection (DOE-ORP) is responsible for management and cleanup of the tank farms located at the Hanford Site. Nuclear waste at Hanford is stored in 149 single-shell tanks (SSTs) and 27 double-shell tanks (DSTs). The vast majority of the liquid radioactive waste is stored in the DSTs. The 27 DSTs, located in six tank farms, were constructed from 1967 to 1986 and, compared to the SSTs, provide greatly improved protection from leakage and better accessibility for inspection. The DSTs and ancillary equipment are expected to exceed their design life before their waste is removed and sent to the Waste Treatment and Immobilization Plant. The DST Integrity Project (DSTIP) must ensure that the DST system can meet the River Protection Project mission goals. This paper provides a programmatic overview of the DSTIP with a focus on development of under-tank inspection technologies. Currently, two categories of nondestructive examination (NDE) techniques for DSTs are implemented on the Hanford site: (1) surface (SNDE) and (2) volumetric (VNDE). Further discussion on current inspection techniques is provided in this paper. The technology development approach for advanced VNDE techniques will also be generally discussed as a precursor for another more detailed WM2020 paper and presentation by PNNL. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Riser Difference Evaluation from Ultrasonic Wall Thickness Inspection of Thirteen Double-Shell Tanks

PNNL has performed an analysis of ultrasonic thickness measurements taken on Hanford's double-shell tanks (DSTs) approximately eight years apart. The analysis was performed to determine whether significant differences exist between ultrasonic thickness measurements made in two opposite risers in Hanford DSTs that have been examined twice.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗