Search NASA⌕ Search

SEARCH · Search NASA

Results for “Droop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Framework for Supporting Adaptive Droop Based Power Electronic Systems

The electric grid is evolving into an electrical network composed of power electronic converters interconnected with renewable and energy storage technologies. This requires the adoption of more advanced control such as volt/var regulation, fast frequency control, and active power frequency response. This work presents a communication and control framework to support dynamically changing droop control segments that can be used for different optimization schemes. Results are presented to work in a controller hardware in the loop testbed.

Starke, Michael↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗

Optimal Droop Setting for Congestion Reduction in a 100% Grid-Forming Inverter-based Power System

he high penetration of inverter-based resources (IBRs) introduces new challenges to power systems due to the complex inverter control. However, IBRs can be configured to maximize their benefits to improve system resilience and reliability. This paper proposes a steady-state optimization model that aims to mitigate transmission congestion in a 100% grid- forming (GFM) IBR-based power system. This goal is achieved by determining the optimal droop settings for the GFM IBRs under different congestion conditions due to renewable energy and load variations. The numerical solution is rigorously verified by a high-fidelity model of the IEEE 39-bus test system with detailed GFM IBR control in the time-domain electromagnetic transient (EMT) simulation tool PSCAD. The numerical solution and simulation results show a significant congestion reduction while meeting all other operating requirements. It is also observed that the numerical solving time is substantially less compared to the EMT simulation time.

Nguyen, Quan H.↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

Generator Frequency Response Droop Monitoring Tool

Monitoring and analyzing the frequency response performance of power generation units is essential for maintaining reliable and secure power system operation. To address this need, an automation tool has been developed to provide a pipeline for processing historical power plant generation data, including large-scale SCADA archives. The tool performs end-to-end processing, including event detection, frequency response (FR) analysis in accordance with NERC standards, and estimation of speed governor droop characteristics. The tool is designed with a modular architecture, allowing individual components of the workflow to be extended, customized, or deployed independently. In addition, the tool provides an API that enables seamless integration with other production systems and operational analytics platforms.

Etingov, PavelV [Pacific Northwest National Labora↗

Model Specification of Droop-Controlled, Grid-Forming Inverters (REGFM_A1)

This document describes a positive-sequence model of droop-controlled, grid-forming (GFM) inverter-based resources (IBRs). It can be considered as an initial model for evaluating the impacts of GFM IBRs on the transients and dynamics of transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Disturbance Propagation Stability in Droop-Controlled Microgrids

The disturbance response of the angle dynamics for a droop-controlled islanded microgrid is characterized. Specifically, a notion of propagation stability is defined, which is concerned with spatial attenuation vs amplification of input- output responses in the network in a H8 or H2 sense. Criteria for propagation stability are developed, phrased in terms of the microgrid’s inverter control parameters. The input frequency range over which the network is susceptible to amplification is also characterized, in the case that the criteria are not met. Based on the formal analysis, a the design of resilient controls that trade off coherence and disturbance propagation goals is briefly conceptualized. Finally, the propagation stability analysis is illustrate using a 15-bus example microgrid network.

Roy, Sandip↗

Large-Scale Adoption of Self Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This poster presents the results of using the self-synchronized universal droop controller to enable solar power to provide ancillary services so that the use of solar power can be increased. A 300-node system using the IEEE 123 bus test feeder are modeled on a real time power system simulator with the results presented.

Arce, Laura↗

Improved Transient Stability Analysis of Multi-loop Droop-Controlled Grid Forming Inverters with Current Reference Limiter

Grid-forming control is regarded as a promising technology for achieving high levels of renewable energy integration in future power grids. To fulfill this role, grid-forming devices is expected to possess fault ride through capability. This paper focuses on the transient stability of a droop control-based grid-forming inverter that utilizes current reference saturation as a current limiting strategy. The objective of this work is to investigate the fault recovery process of the grid-forming inverter and analyze the criterion for transitioning the inverter out of the current limiting mode. The theoretical analysis in this study is validated through time-domain simulations, which compare the results obtained using the circuit current limiting method and the d-axis priority-based current limiting method. Various operational conditions are considered to comprehensively evaluate the performance of the grid-forming inverter during a three-phase short circuit scenario. The simulation results confirm the effectiveness of the proposed theoretical approach.

Lyu, Xue↗