Experimental study of SubMM wave superconducting hot-electron direct detectors
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Direct-write printing techniques will enable new detector assemblies that were not previously possible with traditional assembly processes. Detector concepts were manufactured using this technology to validate repeatability. Additional detector applications and printed wires on a 3-dimensional magnetometer bobbin will be designed for print. This effort focuses on evaluating performance for direct-write manufacturing techniques on 3-dimensional surfaces. Direct-write manufacturing has the potential to reduce mass and volume for fabrication and assembly of advanced detector concepts by reducing trace widths down to 10 microns, printing on complex geometries, allowing new electronic concept production, and reduced production times of complex those electronics.
Direct-write printing techniques will enable new detector assemblies that were not previously possible with traditional assembly processes. Detector concepts were manufactured using this technology to validate repeatability. Additional detector applications and printed wires on a 3-dimensional magnetometer bobbin will be designed for print. This effort focuses on evaluating performance for direct-write manufacturing techniques on 3-dimensional surfaces. Direct-write manufacturing has the potential to reduce mass and volume for fabrication and assembly of advanced detector concepts by reducing trace widths down to 10 microns, printing on complex geometries, allowing new electronic concept production, and reduced production times of complex those electronics.
Because the liquid hydrogen which NASA stores for the space shuttle engines is easily ignited, a hand held ultraviolet fire detector was developed by detector electronics under NASA contract. The system was commercialized by Detector Electronics for use in other hydrogen handling facilities. The detector sensors spot a hydrogen flame at 100 feet, show radiation levels and provide an aural fire alert.
A new, pulsed, high-current, in-line reversal electron attachment ionizer/detector is described. The ionizer is capable of delivering a beam of electrons into an electrostatic mirror field to form a planar wall of electrons having zero kinetic energy. Electron attachment to a molecular target at the reversal point produces either parent or fragment negative ions through a zero-energy (s-wave) state. The atomic or molecular ion is pulsed out of the attachment region approximately 2 microsec after the electrons are pulsed off, and focused onto the entrance plane of a quadrupole mass analyzer. The sensitivity of the apparatus is preliminarily assessed, and its higher-energy behavior with regard to molecular attachment and ionization is described.
An introduction to the major issues encountered in the readout of imaging detector arrays in the infrared are presented. These include circuit issues such as multiplexing, buffering, and noise, as well as materials issues. Future directions in infrared readout electronics will also be discussed. These include on-chip signal processing and advanced hybridization schemes. Finally, recent work at Columbia on 2DEG-charge coupled devices for IR detector multiplexing are described.
Si transmission semiconductor detectors response function for various monoenergetic electrons, estimating detector efficiency
Explore the source record for details and available documents.
A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.
A new approach is proposed to improve the sensitivity of direct-detection bolometers. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or superconductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as 7(exp 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10 - 100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant approx. 10(exp -3) to 10(exp -5) S at T approx. = 0.1 - 0.3 K will exhibit photon-noise limited performance in millimeter and subn-millimeter range. The bolometer will have a figure-of-merit NEk square root of tau approx. = 10(exp -22) 10(exp -21) W/Hz at 100 mK which is 10(exp 3) times smaller than that of a state-of-the-art bolometer. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity This research was performed by the Center for Space Microelectronics Technology, JPL, California Institute of Technology, under the contract for NASA.
The design and testing of ultraheavy-nucleus pulse detectors based on pyroelectric materials are reported, extending the preliminary findings of Tuzzolino (1983) and Simpson and Tuzzolino (1983). Uranium-ion beams of about 240 MeV/u are detected by a 39.5-micron-thick Si detector, degraded to about 175 MeV/u by Al absorbers, and then strike 700-micron-thick polyvinylidene fluoride or 1000-micron-thick LiTaO3 pyroelectric samples. Both detector systems are connected to a coincidence circuit via charge-sensitive preamplifiers, shaping amplifiers with 30-microsec effective time constants, and electronic discriminators. Sample spectra are shown, and the pulse heights measured are found to agree with theoretical calculations to within a factor of about 2. The response of the pyroelectric materials is found to be unaffected by exposure to about 10 Mrad of 2-7-MeV/u heavy ion radiation. With further study and improvement of the detection sensitivity, devices of this type could be applied to large-area space measurements of low ultraheavy-ion fluxes.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A major challenge in advancing nuclear materials for next-generation fission and proposed fusion reactors is to comprehensively understand the formation of irradiation-induced defects. Here it is essential to correlate the evolution of irradiation-induced defects and the degradation of mechanical properties, as they collectively dictate the material's lifespan and ensure nuclear safety. Scanning transmission electron microscopy (STEM) based techniques have emerged as indispensable tools for irradiation-induced defect characterization, offering high spatial resolution imaging and chemical analysis, such as electron energy loss spectroscopy (EELS) and energy dispersive X-ray spectroscopy (EDXS). These techniques have been effectively used to obtain an atomic-scale view of the defect structure. Recent advances in electron microscopy, particularly in 4D-STEM, offer detailed insight into microstructural evolution by capturing full 2D diffraction patterns at every pixel position. Using high-speed direct electron detectors, this technology generates a four-dimensional dataset, overcoming the limitations of traditional STEM imaging.
High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.
Direct electron detectors in scanning transmission electron microscopy give unprecedented possibilities for structure analysis at the nanoscale. In electronic and quantum materials, this new capability gives access to, for example, emergent chiral structures and symmetry-breaking distortions that underpin functional properties. Quantifying nanoscale structural features with statistical significance, however, is complicated by the subtleties of dynamic diffraction and coexisting contrast mechanisms, which often results in a low signal-to-noise ratio and the superposition of multiple signals that are challenging to deconvolute. Here we apply scanning electron diffraction to explore local polar distortions in the uniaxial ferroelectric Er(Mn,Ti)O 3 . Using a custom-designed convolutional autoencoder with bespoke regularization, we demonstrate that subtle variations in the scattering signatures of ferroelectric domains, domain walls, and vortex textures can readily be disentangled with statistical significance and separated from extrinsic contributions due to, e.g., variations in specimen thickness or bending. The work demonstrates a pathway to quantitatively measure symmetry-breaking distortions across large areas, mapping structural changes at interfaces and topological structures with nanoscale spatial resolution.
The Cell G neutron assay system within 7930 provides an important function in the production of Californium-252 in the quantitative determination of the amount of Cf-252 present in a sample. The assay system consists of a Uranium-238 fission chamber coupled to the necessary counting electronics including preamplifier, amplifier, discriminator and counter/timer. The original electronics date back to the 1970s but were replaced back in 2011 with little documentation detailing the testing and replacement efforts. This work focused on procuring a new spare set of electronics, their subsequent testing as a backup in case any of the currently in use electronics were to fail and documentation of the existing and new setups.