Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A new ion and electron detector for ion cyclotron resonance spectroscopy.

A new detector using an extremelly driven tuned circuit has been developed for use in ion cyclotron resonance spectroscopy experiments. Based on the Q-meter circuit, this detector will operate at frequencies greater than 1 MHz at rf levels less than 1 mV. Operation in the frequency range 1-15 MHz allows the use of higher magnetic fields for more efficient storage of low mass ions in the trapping mode of operation. In the frequency range 2-6 MHz electrons can be detected in the ion cyclotron resonance cell by their resonant motion in the trapping plane.

Huntress, W. T., Jr.↗

Radiation testing campaign results for understanding the suitability of FPGAs in detector electronics

SRAM based Field Programmable Gate Arrays (FPGAs) have been rarely used in High Energy Physics (HEP) due to their sensitivity to radiation. The last generation of commercial FPGAs based on 28 nm feature size and on Silicon On Insulator (SOI) technologies are more tolerant to radiation to the level that their use in front-end electronics is now feasible. FPGAs provide re-programmability, high-speed computation and fast data transmission through the embedded serial transceivers. They could replace custom application specific integrated circuits in front end electronics in locations with moderate radiation field. Finally, the use of a FPGA in HEP experiments is only limited by our ability to mitigate single event effects induced by the high energy hadrons present in the radiation field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

D-Zero detector electronics Run IIb upgrade project: VME LVDS SERDES buff (VLSB) module specification

The D0 VME64 LVDS SERDES Buffer (D0 VLSB) is a VME64 [Ref. ] single wide 6U module used for testing the Analog Front-End boards system [Ref. ]. The module is a custom LVDS SERDES Buffer with 4 LVDS inputs channels and can be operated stand-alone with minimal additional hardware. The current testing needs require only a 4 channel D0 VLSB module but the design allows system expansion to multiple modules. A D0 VLSB module can receive/generate trigger signals over two Lemo© [Ref. ] connectors on the module front panel. A normal test system configuration consist of a VME 64 subrack were slot 1 is occupied by a VME subrack controller and the D0 VLSB cards will occupy one or more of the remaining slots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higher-Sensitivity Ionization Trace-Species Detector

Electron source and electron optics of reversal electron-attachment detector modified to increase sensitivity. Original version described in "High-Sensitivity Ionization Trace-Species Detector" (NPO-17596). Used to detect molecules of particular chemical species of interest (e.g., narcotics, explosives, or organic wastes) present in air at low concentrations, and known to attach extremely low-energy electrons. Apparatus does this by ionizing molecules from sampled atmosphere, then detecting ions of species of interest. Detector features indirectly heated spherical cathode and redesigned electron optics, together, deliver more electrons at low kinetic energy to reversal plane, R. Greater electron current generates more ions for detection.

Boumsellek, Said↗

High-speed, multi-channel detector readout electronics for fast radiation detectors

In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps, MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC DSP has been booted with preliminary code. All new ICs and circuitry on the prototype are working properly, however some of the planned firmware and software functions have not yet been completely implemented and debugged. Overall, due to the unanticipated complexity of the PCI Express interface, some aspects of the project could not be completed with the time and funds available in Phase II. These aspects will be completed in self-funded Phase III.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trapped Electrons and Ions as Particle Detectors

Electrons and ions trapped with electromagnetic fields have long served as important high-precision metrological instruments, and more recently have also been proposed as a platform for quantum information processing. Here we point out that these systems can also be used as highly sensitive detectors of passing charged particles, due to the combination of their extreme charge-to-mass ratio and low-noise quantum readout and control. In particular, these systems can be used to detect energy depositions many orders of magnitude below typical ionization scales. As illustrations, we suggest some applications in particle physics. We outline a nondestructive time-of-flight measurement capable of sub-eV energy resolution for slowly moving, collimated particles. We also show that current devices can be used to provide competitive sensitivity to models where ambient dark matter particles carry small electric millicharges $\ll$e. Furthermore, our calculations may also be useful in the characterization of noise in quantum computers coming from backgrounds of charged particles.

47 OTHER INSTRUMENTATION↗

Advanced detector signal acquisition and electron beam scanning for high resolution SEM imaging

We report the advancement of materials science at the mesoscale requires improvements in both sampling volumes/areas and spatial resolution in order to make statistically significant measurements of microstructures that influence higher-order material properties, such as fatigue and fracture. Therefore, SEM-based techniques have become desirable due to improvements in imaging resolution, large sample handling capability, and flexibility for in-situ instrumentation. By using fast sampling of SEM electron detector signals, intrinsic beam scanning defects have been identified that are related to the response time of the SEM electron beam deflectors and electron detectors. Mitigation of these beam scanning defects using detector sampling approaches and an adaptive model for settling time is shown to produce higher resolution SEM images, at faster image acquisition times, with a means to quantify the different response functions for various beam deflectors and detectors including those for electrons and ions.

47 OTHER INSTRUMENTATION↗

White Rabbit Time Synchronization for Radiation Detector Readout Electronics

As radiation detector arrays in nuclear physics applications become larger and physically more separated, the time synchronization and trigger distribution between many channels of detector readout electronics become more challenging. Clocks and triggers are traditionally distributed through dedicated cabling, but newer methods such as the IEEE 1588 Precision Time Protocol and White Rabbit allow clock synchronization through the exchange of timing messages over Ethernet. Consequently, we report here the use of White Rabbit in a new detector readout module, the Pixie-Net XL. Herein, the White Rabbit core, data capture from multiple digitizing channels, and subsequent pulse processing for pulse height and constant fraction timing are implemented in a Kintex 7 FPGA. The detector data records include White Rabbit time stamps and are transmitted to storage through the White Rabbit core's gigabit Ethernet data path or a slower diagnostic/control link using an embedded Zynq processor. The performance is characterized by time-of-flight style measurements and by time correlation of high energy background events from cosmic showers in detectors separated by longer distances. Software for the Zynq processor can implement "software triggering", for example to limit recording of data to events where a minimum number of channels from multiple modules detect radiation at the same time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Effect On Gas Electron Multiplier Detector Performance

Gas Electron Multiplier (GEM) detector is a gas device with high gain and high efficiency. These detectors use chemically perforated 65 {mu}m thick copper clad Kapton polyimide foils. Given its potential for detecting X-rays and other radiations, GEM detectors may be used in an environment with high radioactivity. The Kapton foils manufacturer, Du Pont Inc., claims that the foils are radioactive resistant. To verify whether the GEM detector performance is affected by the exposure to radiation, several GEM foils were irradiated to a {sup 60}Co source at the gamma-ray irradiation facility at Sterigenics, Tustin, CA. Four sets of GEM foils were exposed to the level of 10 kGy, 100 kGy, 1,000 kGy and 10,000 kGy. The output signal from the GEM detectors with irradiated GEM foils were measured and compared to the detector with no irradiation. We observed that the shapes of the peaks from 5.9 KeV {sup 55}Fe X-ray were distorted and that the detector gain increased compared to that of the un-irradiated detector. In particular, the detector with 10,000 kGy irradiation appeared to have the biggest peak distortion and increased gain. It was also found from that additional electrons from radiation-induced free radicals in the Kapton film contribute to output signal of the irradiated GEM detectors. Further studies are needed to explain the mechanism of these detector performance changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modular focusing ring imaging Cherenkov detector for electron–ion collider experiments

A powerful new electron-ion collider (EIC) has been recommended in the 2015 Long Range Plan for Nuclear Science for probing the partonic structure inside nucleons and nuclei with unprecedented precision and versatility [1]. EIC detectors are currently under development [2], all of which require hadron identification over a broad kinematic range. A prototype ring imaging Cherenkov detector has been developed for hadron identification in the momentum range from 3 GeV/c to 10 GeV/c. The key feature of this new detector is a compact and modular design, achieved by using aerogel as radiator and a Fresnel lens for ring focusing. In this paper, the results from a beam test of a prototype device at Fermilab are reported.

aerogel↗