Search NASA⌕ Search

SEARCH · Search NASA

Results for “EQUIPMENT INTERFACES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Deep Learning Potential For Investigation of Chemical Conversion of CO2 at Air-Reactive Deep Eutectic Solvent Interface

Capturing CO2 from air is urgent to battle against the climate change. Traditional CO2 capture by alkaline solution or aqueous amine has high regeneration cost, equipment corrosion, and amine leakage. Deep eutectic solvents (DESs) are promising alternatives with low corrosion, non-toxicity, and biodegradable nature. Functionalized DESs can capture and convert CO2 at low partial pressures. Developing reactive DESs for efficient CO2 capture needs a foundational understanding of the reaction-transport coupling of CO2 at the air-DES interface. In this study, we develop a deep learning potential (DLP) to investigate the absorption and reaction of CO2 at the air-DES interface (DES: 1-ethyl-3-methylimidazolium 2-cyanopyrrolide ([Emim][2-CNpyr]) and ethylene glycol (EG)). The DLP model allows us to simulate chemical reactions at a lower computational cost with ab initio accuracy. By analyzing reaction free energy surfaces, molecular interactions among CO2, DES components and reaction products, and transport of CO2 through the interface, we identify three main reaction pathways of CO2 at the interface: forming carboxylate with [Emim], carbamate with [2-CNpyr], and carbonate with EG. The mechanistic understanding of CO2 chemisorption at the interface will facilitate the development of novel direct air capture technology using DESs.

Nguyen, Manh Tien↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Controller Requirements for Managing Community Microgrids

Microgrid control systems are central to the functioning of a microgrid. They are responsible for managing distributed energy resources (DER) in both grid-connected and islanded modes of operation. Although microgrids are being developed and deployed by many utilities, several questions are being raised about the control system that manages them. This document provides the detailed list of requirements for a feeder-level microgrid controller to manage various islanded and grid-connected use cases. Functionally, the use cases include control scenarios that require the controller to maintain energy balance, prevent constraint violations, manage switching equipment, manage grid-forming (GFM) and grid-following (GFL) DER, manage critical/non-critical loads, and coordinate with peer systems to operate joined island areas. In addition to detailed requirements, the document includes interface and performance metrics for functional evaluation. These requirements can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; requirements also apply to third-party managed microgrid controllers that coordinate with the utility- and customer-owned equipment. The document can also be used by technology developers and project developers in industry to specify desired control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability Enhancement and Microstructural Modification of Ni-Rich Cathodes via Halide Doping

In this study, elemental doping is an effective strategy to modify surface and bulk chemistry in NMC cathode materials. By adding small amounts of lithium halide salts during the calcination process, the Ni-rich NMC811 cathode is doped with Br, Cl, or F halogens. The dopant type has a significant impact on the lithiation process and heavily influences the final cathode porosity and surface morphology. Utilizing a variety of electrochemical, surface, and bulk characterization techniques, it is demonstrated that an initial content of 5 mol % LiBr or LiCl in the lithium source is effective in improving capacity retention while also providing excellent rate performance. The improvements are attributed to a substantial increase in specific surface area, the formation of a stable cathode electrolyte interface (CEI) layer, and suppressed surface reconstruction. In addition, the particle microstructure is better equipped to handle cyclic volume changes with increased values of critical crack lengths. Overall, it is demonstrated that anion doping via the addition of lithium halide salts is a facile approach toward Ni-rich NMC modification for enhanced cathode performance.

25 ENERGY STORAGE↗

Feasibility Analysis of Converter-Interfaced Combined Heat and Power System

As a promising new design concept, the converter-interfaced combined heat and power (CHP) system is coupled to the bulk grid through a rectifier and a grid-ready tied inverter. Compared to the traditional directly-coupled CHP system, it removes the requirement for oversizing the CHP generator, limits the short-circuit contribution of the generator and simplifies the grid integration process of CHP system. This paper evaluates the economic benefits of this concept by calculating the annualized Return-on-Investment (ROI) and comparing it to the directly-coupled system. The economic analysis includes timeseries simulations to compute energy transactions with the bulk grid as well as sizing the equipment to calculate the capital and operational costs. Obtained results indicate that in majority of user cases evaluated, the converter-interfaced CHP systems can provide better ROI than directly-coupled systems. Given the additional technical benefits provided by inverter-based distributed energy resources (DERs), the proposed concept is proved to be technically viable and economically feasible.

03 NATURAL GAS↗

Bipolar Membranes for Ion Management in (Photo)Electrochemical Energy Conversion

Conspectus (Photo)electrochemical energy conversion is important in the development of a carbon-neutral energy economy because it can provide a pathway for mitigating the intermittency of renewable energy sources such as wind and solar. In order to operate efficiently, these technologies, which include photoelectrochemical cells, water and CO 2 electrolyzers, fuel cells, and redox flow batteries, require fast charge transfer kinetics at the electrode/electrolyte interface as well as robust ion management in the electrolyte. In conventional electrolyzers and fuel cells, the electrolyte is strongly acidic or basic and ionic current is carried by H + or OH – ions. In contrast, photoelectrodes and electrocatalysts for water splitting are often studied in buffered solutions. The question of ion balance in these systems led us to analyze the polarization losses due to ion concentration gradients in cells that employed various buffer–membrane combinations. Continuously driving the buffer ions across an ionomer membrane not only lowers the buffer capacity of an aqueous electrolyte but also introduces pH gradients that result in significant energy losses. To address the problem, we and other groups have studied the use of reverse-biased bipolar membranes (BPMs) in (photo)electrolytic cells. BPMs consist of an anion exchange layer (AEL) laminated with a cation exchange layer (CEL) and are usually equipped with a catalytic layer in between to accelerate the water dissociation reaction. At the AEL/CEL interface, water dissociates into protons and hydroxide ions, which replenish those consumed at the cathode and anode. Compared to conventional water electrolyzers with proton/anion exchange membranes (PEM/AEM), BPM electrolyzers provide the unique advantage of continuously operating the cathode and anode under different pH conditions, which is desirable when the two electrode reactions have different pH requirements. BPMs also enable the use of buffered electrolytes at pH values that are optimized for electrode stability and product selectivity in applications such as CO 2 electrolysis. Product crossover losses and CO 2 pumping can be dramatically reduced in BPM-based CO 2 electrolyzers, relative to conventional alkaline membranes, by electrostatic repulsion (of anionic products) and electroosmotic drag (for neutral products). BPM-based gas fed CO 2 electrolyzers can achieve high current density, but they suffer from low Faradaic efficiency (FE) due to the acidic local environment of the CEL. This problem can be mitigated by adding an aqueous buffering layer or by creating a weak acid cation exchange film on the CEL face of the membrane. The use of BPMs in fuel cells and redox flow batteries offers some interesting advantages. Configurations with both reverse and forward bias have been studied, but forward bias has been favored due to material compatibility, reaction kinetics, and thermodynamic considerations. The net reaction at the AEL/CEL interface is the acid–base neutralization reaction, which has a high inherent reaction rate constant, but in the BPM is limited to a nanometric space-charge layer and requires efficient catalysis to achieve high current density. Understanding the mechanism of the acid–base neutralization and the opposite process, the water dissociation reaction, will be essential for improving the performance of forward-biased BPMs. In conclusion, this Account reviews our current understanding of the working mechanisms of BPMs and discusses how we can use them to effectively manage ions for various (photo)electrochemical applications.

Yan, Zhifei↗

ZPAL v.1.0.0

SAND2024-01003O ZPAL is a Python software development kit designed for use by network automation engineers. It is an application programming interface (API) wrapper that is compatible with ZPE System's Nodegrid API. ZPE produces networking equipment. ZPAL simplifies connections to the ZPE Nodegrid API and makes configuration changes on the associated networking equipment. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hill, Roscoe↗

DualSPHysics-INL

Funded by the DOE's Bioenergy Technology Office through the Feedstock-Conversion Interface Consortium, INL researchers developed this code to model biomass freestock flow in various handling equipment, such as hoppers and augers. Built on top of an existing open-source code DualSPHysics (https://dual.sphysics.org/) , the enrichment includes modification of the mass conservation equation that switching tracking density to void ratio, adding a hypoplastic constitutive law to better capture the flow physics of this type of material and implementing a novel boundary condition that can handle the dynamic contact between material and equipment. All implementation were realized via Nvidia CUDA, so GPU accelaration can be leveraged to signifiantly speed up the computational process.

Jin, Wencheng [Idaho National Laboratory (INL), Id↗

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Grassroots Network and Community Roadmap for Interconnected Autonomous Science Laboratories for Accelerated Discovery

Scientific discovery is being revolutionized by AI and autonomous systems, yet current autonomous laboratories remain isolated islands unable to collaborate across institutions. We present the Autonomous Interconnected Science Lab Ecosystem (AISLE), a grassroots network transforming fragmented capabilities into a unified system that shorten the path from ideation to innovation to impact and accelerates discovery from decades to months. AISLE addresses five critical dimensions: (1) cross-institutional equipment orchestration, (2) intelligent data management with FAIR compliance, (3) AI-agent driven orchestration grounded in scientific principles, (4) interoperable agent communication interfaces, and (5) AI/ML-integrated scientific education. By connecting autonomous agents across institutional boundaries, autonomous science can unlock research spaces inaccessible to traditional approaches while democratizing cutting-edge technologies. This paradigm shift toward collaborative autonomous science promises breakthroughs in sustainable energy, materials development, and public health.

Ferreira da Silva, Rafael [Oak Ridge National Labo↗

All‐Solid‐State Lithium–Sulfur Batteries of High Cycling Stability and Rate Capability Enabled by a Self‐Lithiated Sn‐C Interlayer

Abstract All‐solid‐state lithium–sulfur batteries (ASSLSBs) have attracted intense interest due to their high theoretical energy density and intrinsic safety. However, constructing durable lithium (Li) metal anodes with high cycling efficiency in ASSLSBs remains challenging due to poor interface stability. Here, a compositionally stable, self‐lithiated tin (Sn)‐carbon (C) composite interlayer (LSCI) between Li anode and solid‐state electrolyte (SSE), capable of homogenizing Li‐ion transport across the interlayer, mitigating decomposition of SSE, and enhancing electrochemical/structural stability of interface, is developed for ASSLSBs. The LSCI‐mediated Li metal anode enables stable Li plating/stripping over 7000 h without Li dendrite penetration. The ASSLSBs equipped with LSCI thus exhibit excellent cycling stability of over 300 cycles (capacity retention of ≈80%) under low applied pressure (<8 MPa) and demonstrate improved rate capability even at 3C. The enhanced electrochemical performance and corresponding insights of the designed LSCI broaden the spectrum of advanced interlayers for interface manipulation, advancing the practical application of ASSLSBs.

Ye, Lei↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

From Obsolete to Optimal (ATR Demineralized Water System)

My project was migrating a Human-Machine Interface (HMI) and Programmable Logic Controller (PLC) program from legacy software to a modern platform, enhancing operational efficiency and eliminating unsupported, obsolete equipment. Initially, I used a migration tool to transfer the programs to the new software, then manually updated variables to align with the new PLC. I optimized the PLC code by leveraging new scaling features in the I/O cards, removing over 45 obsolete rungs, and enhancing clarity with functional tag aliases. Next, I modernized the HMI's visuals with an updated color scheme and 3D buttons. I developed multiple interface versions iteratively refining them based on operator feedback. I also designed and created a dedicated "Rounds" screen incorporating insights from a previous intern’s project to streamline daily rounds. To improve clarity, consistency, and efficiency I redesigned the entire interface. Adding visual indicators to enhance operational awareness: red is used for values outside normal specifications, green for normal operating modes, yellow for manual mode, and grey for offline units. Additionally, I added a dynamic visual representation of tank levels, creating PLC logic to show the level in inches as well as inches and feet. I then incorporated a navigation sidebar to facilitate efficient screen transitions. Risk of human error was mitigated by defining narrow input ranges for tank level shutoff and password protecting setpoint changes. I also fixed issues with datatypes that caused inaccuracies in the original code. Overall, this comprehensive upgrade significantly enhanced the HMI's functionality, user experience, and operational reliability.

47 - OTHER INSTRUMENTATION↗

Coordination-Dependent Chemical Reactivity of TFSI Anions at a Mg Metal Interface

Charge transfer across the electrode–electrolyte interface is a highly complex and convoluted process involving diverse solvated species with varying structures and compositions. Despite recent advances in in situ and operando interfacial analysis, molecular specific reactivity of solvated species is inaccessible due to a lack of precise control over the interfacial constituents and/or an unclear understanding of their spectroscopic fingerprints. However, such molecular-specific understanding is critical to the rational design of energy-efficient solid–electrolyte interphase layers. We have employed ion soft landing, a versatile and highly controlled method, to prepare well-defined interfaces assembled with selected ions, either as solvated species or as bare ions, with distinguishing molecular precision. Equipped with precise control over interfacial composition, we employed in situ multimodal spectroscopic characterization to unravel the molecular specific reactivity of Mg solvated species comprising (i.e., bis(trifluoromethanesulfonyl)imide, TFSI – ) anions and solvent molecules (i.e., dimethoxyethane, DME/G1) on a Mg metal surface relevant to multivalent Mg batteries. In situ multimodal spectroscopic characterization revealed higher reactivity of the undercoordinated solvated species [Mg-TFSI-G1] + compared to the fully coordinated [Mg-TFSI-(G1) 2 ] + species or even the bare TFSI – . These results were corroborated by the computed reaction pathways and energy barriers for decomposition of the TFSI – within Mg solvated species relative to bare TFSI – . Finally, we evaluated the TFSI reactivity under electrochemical conditions using Mg(TFSI) 2 –DME-based phase-separated electrolytes representing different solvated constituents. Based on our multimodal study, we report a detailed understanding of TFSI – decomposition processes as part of coordinated solvated species at a Mg-metal anode that will aid the rational design of improved sustainable electrochemical energy technologies.

25 ENERGY STORAGE↗

Design of the Electromagnetic Particle Injector (EPI) for Tokamak Deployment

Both predicting and controlling disruptions are critical and urgent issues for ITER as some disruptions with a short warning time may be unavoidable. For these cases, a rapid response disruption mitigation system (DMS) referred to as the electromagnetic particle injector (EPI) is being developed. The primary advantages of the EPI are its fast response time and high velocity, which have been demonstrated in offline experiments (Raman et al., 2021). The EPI is capable of accelerating a metallic sabot electromagnetically using a rail gun to the required velocities ( > 2 km/s) within 2 ms. Two high-field racetrack magnets able to generate fields over 2 T are positioned above and below the rails to permit high velocity at low rail currents, a requirement to minimize electrode erosion. At the end of the acceleration phase, a sabot capture mechanism retains the spent sabot inside the vacuum chamber that houses the EPI. At this point, it releases well-defined microspheres, or a shell pellet, of a radiative payload into the disrupting plasma. A remotely operated sabot loading system positioned behind the injector contains several pre-equipped sabots that can be loaded by an operator from the tokamak control room. The injector is interfaced to the tokamak through a guide tube attached to the front of the EPI vacuum chamber. Finally, the advantages of the EPI system over other DMSs under consideration are described in conjunction with the details of an EPI system designed for near-term test on an existing large tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interfaces in all solid state Li-metal batteries: A review on instabilities, stabilization strategies, and scalability

With technological advancements in electrochemical energy storage systems increasing at a spectacular rate, batteries equipped with a lithium anode hold the key towards unlocking high energy densities. While lithium-ion batteries with layered anodes (e.g. graphite) and liquid organic electrolytes have been ubiquitous in portable electronics, electric vehicles, and grid applications, all solid-state batteries that use the combination of a lithium anode and a solid-state electrolyte (SSE) will further advance the present technology. The underlying challenge that limits the successful development of all solid-state batteries (ASSBs) is dictated largely by the highly reactive interfaces at the anode/SSE and the cathode/SSE interface. In this comprehensive review, we present an overview of the following: (i) characterization of the electrode/SSE interface via multimodal characterization, which include X-ray-, electron-, neutron-, optical-, and computation-based methods: (ii) parasitic reactions that occur from chemical, mechanical or electrochemical instabilities and interfacial engineering strategies for improving the stability of these interfaces classified by the class of inorganic SSEs (sulfide-, NASICON-, and garnet-type SSEs); (iii) laboratory-to-industry scale processing perspectives of SSEs; (iv) scalability and manufacturing aspects of current interfacial strategies; and (v) the prospects of all ASSBs within the context of extreme fast charging capability. Here, this review seeks to highlight key efforts in the field of ASSBs, by focusing particularly on stabilizing the electrode/SSE interfaces, which will help to bridge fundamental studies to technological relevance.

25 ENERGY STORAGE↗

EVSE DERMS Controls [SWR-26-010]

An MQTT (Message Queuing Telemetry Transport) and OCPP (Open Charge Point Protocol) based remote smart charging controller framework for AC Electric Vehicle Supply Equipments (EVSEs). The code in this repo allows for the National Laboratory of the Rockies (NLR) controls to interface with the real Distributed Energy Resource Management System (DERMS) and EVSEs in NLR's ESIF Optimization and Control Laboratory (OCL). Different charge management algorithms can be tested to determine which power allocation method is most effective with the overall goal of demonstrating clear and well documented test results as well as providing functional control algorithms which could be utilized to provide effective smart charge management (SCM) at EV charging stations. Different power allocation methods are programmed in lab_demo_controller.py and include allocation based on first come first served, equal sharing, state of charge (SOC), priority factors, and behind the meter control methods.

Panossian, Nadia [National Laboratory of the Rocki↗